Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “VENTILATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85Linked to original sources

Predicting eventual success or failure to wean in patients receiving long-term mechanical ventilation.

PURPOSE: To determine if the ultimate ability of a long-term ventilated patient to wean can be predicted at the time of his or her admission to a long-term ventilator unit. DESIGN: Two-phased prospective study. SETTING: Long-term ventilator facility, university-affiliated. SUBJECTS: Adults ventilated for an average of 3 weeks, who did not have sepsis and who did not have chest tubes or progressive neurologic impairment. INTERVENTIONS: On admission to the long-term ventilator unit, historic factors, ventilator history, and the following laboratory and metabolic tests were obtained: electrolytes, serum calcium, magnesium, and phosphorus, WBC, hemoglobin, albumin, total protein, transferrin, oxygen consumption, carbon dioxide production, respiratory quotient, and dead space/tidal volume. The patients were then placed in a weaning protocol utilizing increasing duration of pressure support ventilation during the day with complete rest at night. Forty-two days after enrollment in the study, representing three times the duration of the weaning protocol, the patients who successfully weaned were compared to those who remained ventilator dependent (n = 20). Patients who died or were transferred to another institution were excluded from this phase of the study, because we were trying to develop parameters that would be predictive of successful weaning. A parameter was considered to be predictive, and retained for the scoring system, if it produced at most 15% false-positives and false-negatives. A score of 0 was then assigned to the threshold value that produced no false-positives; 2 to the threshold value that produced no false-negatives and 1 to the intermediate values. The scoring system was then applied to a new prospective group of patients (n = 72). MEASUREMENTS AND MAIN RESULTS: Of all the parameters evaluated, only the following satisfied the false-positive and false-negative requirements; static compliance, airway resistance, dead space to tidal volume ratio, PaCO2, and frequency/tidal volume. Applying these, in the scoring system, to the initial group of patients, demonstrated that a score greater than 3 was associated with failure to wean; a score less than 3 was associated with successful weaning, and a score of 3 was not predictive. Using these thresholds, the data were applied to the new prospective group of patients, which again demonstrated that a score of greater than 3 was associated with failure to wean in all cases. A score less than 3 was again associated with successful weaning but there were two false-positives. The sensitivity, specificity, and positive predictive and negative predictive values for the scoring system were 1.0, 0.91, 0.83, and 1.0, respectively. None of the individual parameters included in the scoring system demonstrated equivalent statistical results. All but two of the patients who died prior to finishing the weaning period had weaning scores, which suggested that they would not be successfully weaned. CONCLUSIONS: Parameters that are generally available, when combined into a scoring system, can predict at the time of admission to a long-term ventilator unit, in most cases, whether a patient will eventually wean. The scoring system resulted in no false-negatives and an acceptable number of false-positives. None of the individual parameters were as reliable as the scoring system as a whole.

Aged↗

Intrahospital transport of critically ill patients using ventilator with patient-triggering function.

OBJECTIVE: To compare a new transport ventilator to manual ventilation in terms of maintaining the respiratory and hemodynamic levels of critically ill patients. DESIGN: Prospective, randomized, single-center study. SETTING: ICU in a university hospital. PATIENTS: A total of 16 patients (22 transports) who were spontaneously breathing and required ventilatory assistance on excursions from the ICU. METHODS: For each transport, the patient was randomly assigned to receive either manual ventilation (group M) or mechanical ventilation (group V). For transports in group V, the ventilators were set the same as in the ICU. Respiratory and hemodynamic variables were measured 30 min before transport (T(0)), on arrival at the site of procedure (T(1)), on return to the ICU (T(2)), and 30 min after return the ICU (T(3)). RESULTS: After transport, five patients in group M showed a significant deterioration in PaO(2)/fraction of inspired oxygen ratio, while one patient in group V showed deterioration (p = 0.056). The mean (+/- SD) respiratory rate in group M at T(2) (32 +/- 9 breaths/min) was significantly higher (p < 0.001) than at T(0) (19 +/- 6 breaths/min) and also was higher (p < 0.01) than in group V at T(2) (19 +/- 6 breaths/min). The mean tidal volume and positive end-expiratory pressure in group M at T(2) showed significantly larger variation (p < 0.05 and p < 0.001, respectively) than in group V. CONCLUSIONS: The transport ventilator that was recently approved by the US Food and Drug Administration reliably provides more stable ventilatory support than does manual ventilation. Generally, the use of this transport ventilator for intrahospital transport is preferable to manual ventilation.

Critical Illness↗

Reduced inspiratory muscle endurance following successful weaning from prolonged mechanical ventilation.

STUDY OBJECTIVES: Respiratory muscle weakness and decreased endurance have been demonstrated following mechanical ventilation. However, its relationship to the duration of mechanical ventilation is not known. The aim of this study was to assess respiratory muscle endurance and its relationship to the duration of mechanical ventilation. DESIGN: Prospective study. SETTING: Tertiary teaching hospital ICU. PATIENTS: Twenty subjects were recruited for the study who had received mechanical ventilation for > or = 48 h and had been discharged from the ICU. MEASUREMENTS: FEV1, FVC, and maximal inspiratory pressure (P(I(max)) at functional residual capacity were recorded. The P(I(max)) attained following resisted inspiration at 30% of the initial P(I(max)) for 2 min was recorded, and the fatigue resistance index (FRI) [P(I(max)) final/P(I(max))initial] was calculated. The duration of ICU length of stay (ICULOS), duration of mechanical ventilation (MVD), duration of weaning (WD), and Charlson comorbidities score (CCS) were also recorded. Relationships between fatigue and other parameters were analyzed using the Spearman correlations (rho). RESULTS: Subjects were admitted to the ICU for a mean duration of 7.7 days (SD, 3.7 days) and required mechanical ventilation for a mean duration of 4.6 days (SD, 2.5 days). The mean FRI was 0.88 (SD, 0.13), indicating a 12% fall in P(I(max)), and was negatively correlated with MVD (r = -0.65; p = 0.007). No correlations were found between the FRI and FEV1, FVC, ICULOS, WD, or CCS. CONCLUSIONS: Patients who had received mechanical ventilation for > 48 h have reduced inspiratory muscle endurance that worsens with the duration of mechanical ventilation and is present following successful weaning. These data suggest that patients needing prolonged mechanical ventilation are at risk of respiratory muscle fatigue and may benefit from respiratory muscle training.

Adult↗

A ventilator generating a positive or negative internal compliance.

This paper describes technical details of a ventilator for altering the resistive and elastic load placed on respiratory muscles during spontaneous breathing in intubated infants. Positive or negative values for ventilator resistance and/or ventilator compliance can be chosen by superimposing the weighted sum of the flow and/or the volume signal over the input to a pressure controller within the pressure feedback control system of the ventilator. The aim of the study was to compare values of the ventilator's compliance (Cv), as measured with a ventilation mechanics calculator, with those Cv values set by the ventilator's Cv control knob on the front panel. Another aim was to compare measured values of total compliance of a combined ventilator-lung model system (Ct) with the values expected according to theory where 1/Ct = 1/Cv + 1/C1m (Eq. alpha; C1m is the lung model's compliance). The Cv values set on the front panel were nearly identical to those measured (Cvm = 0.97 * Cvs + 0.54) over the whole tested range from -20 to +20 ml/kPa. Similarly, the measured Ct values were almost equal to those expected according to Eq. alpha; the standard deviation of the relative residuals was 2.7% for elastic loading and 12.4% for elastic unloading. We conclude that the ventilator described in this study can effectively provide both elastic loading and elastic unloading of spontaneous breathing, as expected according to theory.

Biomedical Engineering↗

Gastric intramural pH as a predictor of success or failure in weaning patients from mechanical ventilation.

OBJECTIVE: To determine whether gastric intramural pH (pHi), an indirect measure of gastric mucosal ischemia, can be used to predict the success of weaning from mechanical ventilation. Gastric mucosal ischemia (and, therefore, acidosis) may develop in patients during unsuccessful attempts to wean them from mechanical ventilation because blood flow from nonvital areas (for example, splanchnic bed) is diverted to meet the increased demands of respiratory muscles. DESIGN: Cohort study. SETTING: Intensive care unit. PATIENTS: Twenty-nine patients receiving assisted mechanical ventilation for respiratory failure who were thought by their physicians to be weanable from mechanical ventilation. MEASUREMENTS: Simultaneous samples of arterial blood and gastric juice were obtained from patients during assisted mechanical ventilation, as well as during weaning trials. The predictor variable, pHi, was calculated using the following equation: 6.1 + log HCO3/(gastric PCO2 x 0.0307). The outcome was success or failure of weaning, decided by physicians blinded to the study. RESULTS: Patients who could not be weaned from mechanical ventilation had a substantially reduced gastric pHi (7.36 during mechanical ventilation compared with 7.09 during weaning [difference, 0.27; 95% Cl, 0.12 to 0.42; P < 0.01]). Patients who were successfully weaned from mechanical ventilation showed no change in pHi (7.45 during mechanical ventilation compared with 7.46 during weaning [difference, 0.01; Cl, -0.01 to 0.03; P = 0.29]). The sensitivity and specificity of pHi in predicting weaning success or failure were both 100% (Cl, 81 to 100 and 72 to 100, respectively). CONCLUSION: Gastrointestinal acidosis may be an early sign of weaning failure. Measurement of pHi, which is simple and rapid, may be of practical value in predicting the likelihood of weaning success or failure during weaning trials.

Acidosis↗

Laboratory and clinical evaluation of the MAX transport ventilator.

UNLABELLED: Transport of critically ill, mechanically ventilated patients from intensive care units for diagnostic and therapeutic procedures has become common in the last decade. Maintenance of adequate oxygenation and ventilation during transport is mandatory. We evaluated the Hamilton MAX transport ventilator in the laboratory and in the clinical arena to determine its usefulness during in-hospital transport. METHODS: In the laboratory, we determined the MAX's ability to assure tidal volume (VT) delivery in the face of decreasing compliance of a test lung, and we tested the alarm system. Using a two-compartment lung model modified to simulate spontaneous breathing, we also evaluated the responsiveness of the demand valve. The clinical evaluation was accomplished by comparing arterial blood gases and ventilator settings in the intensive care unit to those during transport. RESULTS: As lung compliance was reduced from 0.1 to 0.02 L/cm H2O [1.0 to 0.20 L/kPa], delivered VT fell significantly at each set VT. The alarm systems performed according to manufacturer's specifications. The demand valve triggered appropriately without positive end-expiratory pressure (PEEP), but as PEEP was increased, triggering became more difficult. The demand valve is referenced to ambient pressure and cannot compensate for elevated end-expiratory pressures. During patient transport, arterial blood gases were comparable to those achieved in the ICU. Because an inspired oxygen concentration of 1.0 was used during transport, arterial oxygenation (PaO2) was significantly greater (123 +/- 75 vs 402 +/- 85 torr [16.4 +/- 10 vs 53.6 +/- 11 kPa]). A higher ventilator rate was required during transport to prevent tachypnea (7 +/- 3 vs 12 +/- 6 breaths/min), and peak inspiratory pressure (PIP) was higher during transport (40 +/- 8 vs 52 +/- 11 cm H2O [3.9 +/- 0.8 vs 5.1 +/- 1.1 kPa]). CONCLUSIONS: The MAX is a reliable transport ventilator, capable of maintaining adequate ventilation and oxygenation in a majority of mechanically ventilated patients. Care should be taken to assure adequate VT delivery at high PIP, and ventilator rate may require adjustment to prevent tachypnea associated with triggering the non-PEEP-compensated demand valve when PEEP greater than 8 cm H2O [0.8 kPa] is used.

Adult↗

Laboratory and clinical evaluation of the impact Uni-Vent 750 portable ventilator.

BACKGROUND: Transportation of critically ill, mechanically ventilated patients from intensive care units for diagnostic and therapeutic procedures has become common in the last decade. Maintenance of adequate oxygenation and ventilation during transport is essential. We evaluated the Impact Uni-Vent 750 portable ventilator in the laboratory and in the clinical arena to determine its usefulness during inhospital transport. MATERIALS & METHODS: In the laboratory, we determined the Uni-Vent 750's ability to assure tidal volume (VT) delivery in the face of decreasing compliance of a test lung and tested the alarm systems. Using a two-compartment lung model modified to simulate spontaneous breathing, we also evaluated the responsiveness of the demand valve. The clinical evaluation was accomplished by comparing arterial blood gas values and ventilator settings in the intensive care unit before transport to those during transport. RESULTS: As lung compliance was reduced from 0.1 to 0.02 mL/cm H2O [1.0 to 0.20 L/kPa], a slight, statistically insignificant decrease in delivered tidal volume was observed. All alarm systems operated according to manufacturer's specifications. The demand valve triggered appropriately with PEEP from 0 to 20 cm H2O [0 to 1.96 kPa]. Sensitivity settings less than -6 cm H2O [-0.59 kPa] sometimes resulted in inability to trigger the demand valve. During patient transport, arterial blood gas values and ventilator settings were comparable to those observed in the ICU. Because an FIO2 of 1.0 was used during transport, mean (SD) PaO2 was significantly greater 89 (26) vs 341 (78) [11.8 (3.5) vs 45.3 (10.4) kPa]. CONCLUSIONS: The Uni-Vent 750 is a reliable transport ventilator, capable of maintaining adequate oxygenation and ventilation in a majority of mechanically ventilated patients. The Uni-Vent 750's ability to (1) provide CMV, AMV, and SIMV; (2) provide low and high pressure alarms; and (3) provide PEEP compensation is unique among portable ventilators.

Adult↗

[Regional assessment of treatment in lung cancer using lung perfusion and ventilation images].

In 30 patients with lung cancer undergoing non-surgical treatment, we performed perfusion lung imaging using 99mTc-MAA and inhalation lung studies using Technegas before and after treatment and evaluated regional perfusion and ventilation status in the lung regions where bronchogenic carcinoma was located. Regional ventilation status was preserved rather than perfusion counterpart (V > P) in 18 patients (18/30 = 60.0%) before treatment, while the former was better than the latter in 27 patients (27/30 = 90.0%) after treatment, indicating that regional ventilation status improved more significantly than regional perfusion counterpart after treatment (p = 0.005). We also classified the therapeutic effect for regional perfusion and ventilation status as improved, unchanged, or worsened, respectively; improvement in regional perfusion status was observed in 17 patients (56.7%) and that in regional ventilation status in 24 patients (80.0%). There was a statistically significant correlation between improved regional perfusion and ventilation status (p = 0.0018) when therapeutic effect was recognized. The patients who showed improvement in regional perfusion status after treatment always showed improved regional ventilation status, but 7 patients showed either unchanged or worsened regional perfusion status after treatment, although regional ventilation status was improved. In conclusion the pulmonary vascular beds seem more vulnerable to bronchogenic carcinoma and improvement in regional perfusion status was revealed to be more difficult than that in regional ventilation status after treatment.

Adult↗

Ventilator-associated pneumonia with circuit changes every 2 days versus every week.

BACKGROUND: Frequent ventilator circuit changes are expensive and sometimes unnecessary. Following the worldwide trend to lengthen the intervals for ventilator circuit change from 2 days to 1 week, this study aims to assure that low rate of ventilator-associated pneumonia (VAP) can be maintained with cost containment. METHODS: Ventilator circuits were routinely changed every 7 days in the study period for 2 years and every 2 days during the historical control period of another 2 years. Pediatric patients (age less than 15 years) were not included. Nosocomial pneumonia was diagnosed by the criteria of the Centers of Disease Control and Prevention (CDC) of the United States (US). VAP was identified by combining and comparing 2 databases from the Respiratory Therapy Department and the Infection Control Unit of our hospital. RESULTS: In the study group, 225 episodes of pneumonias were observed in 7,068 patients and 87,338 ventilator days. The rate of VAP was 2.58 per 1,000 ventilator days. There were 174 episodes of pneumonia in 6,213 patients and 65,467 ventilator days of the control group. The rate of VAP was 2.66 per 1,000 ventilator days. The difference between both groups was not significant (p = 0.803). Yet, the cost curbed was around 80,000 US dollars per year. CONCLUSIONS: Extending ventilator circuit change interval from 2 days to 7 days do not increase the risk for VAP, but the cost savings for labor and supply are substantial.

Adult↗

Removal of CO2, moisture and heat from ventilated suit under different pressures.

The relative equation among CO2 partial pressure in a helmet, ventilating flow, pressure and CO2 output, the relative equation among ventilating flow, pressure, humidity and rate of moisture removal, and the relative equation among ventilating flow, pressure, humidity and rate of heat removal were derived and analyzed. Its demonstrated that: ventilating mass flow for a constant CO2 partial pressure in the helmet decreases linearly as the pressure drops; the ventilating mass flow for removing a constant quantity of moisture decreases as pressure drops; the efficiency of heat removal increases as pressure drops due to the increase of moisture removal. The equations can be used for estimating ventilating flow in a ventilated suit and ventilating flow entering the helmet, and also for calculating automatically the quantities of moisture and heat removal by ventilation.

Carbon Dioxide↗

The impact of closed endotracheal suctioning systems on mechanical ventilator performance.

BACKGROUND: Closed endotracheal suctioning during mechanical ventilation is increasingly used, but its impact on ventilator function has not been fully studied. METHODS: We evaluated the impact of closed suctioning with 11 critical-care ventilators, during assisted ventilation in pressure-support mode, pressure-assist/control mode, volume-assist/control mode, and during continuous positive airway pressure, with 2 suctioning pressures (-120 mm Hg and approximately -200 mm Hg), and with 2 tidal volumes (450 mL and 900 mL). We continuously measured airway pressure, flow at the airway, and pressure distal to the catheter tip, before, during, and after a single 15-second period of continuous suctioning. RESULTS: No ventilator malfunctioned as a result of the closed suctioning. During suctioning, end-expiratory pressure markedly decreased in all modes, and peak flow increased in all modes except volume-assist/control (p < 0.001). Respiratory rate increased during suctioning in pressure- and volume-assist/control (p < 0.001) but not during pressure support or continuous positive airway pressure. Gas delivery was most altered during volume-assist/control with the smaller tidal volume (p < 0.05) and least altered during pressure-assist/control with the larger tidal volume. CONCLUSION: There are large differences between the ventilators evaluated (p < 0.001). Closed suctioning does not cause mechanical ventilator malfunction. Upon removal of the suction catheter, these ventilators resumed their pre-suctioning-procedure gas delivery within 2 breaths, and, during all the tested modes, all the ventilators maintained gas delivery. However, closed suctioning can decrease end-expiratory pressure during suctioning.

Equipment Design↗

[Exhaled tidal volume is overestimated due to cardiogenic oscillation: effects of ventilator and mode].

BACKGROUND: We investigated effects of cardiogenic oscillation on overestimation of tidal volume using a lung model, with three ventilators and two ventilatory modes. METHODS: We simulated cardiogenic oscillation at a rate of 90 breaths x min(-1) by ventilating one bellow of a two-bellow-type lung model. The magnitude of cardiogenic oscillation was defined as peak expiratory flow fluctuation when the airway was opened to the atmosphere. The lung model was mechanically ventilated with three ventilators (Bird 8400 STi, Servo-300, and Nellcor Puritan-Bennett 840), two ventilatory modes (volume- and pressure-controlled ventilation), and two respiratory rates (5 and 10 breaths x min(-1)) in random order. We recorded tidal volume on a ventilator monitor and calculated the discrepancy from the set tidal volume. RESULTS: With Bird 8400 STi, monitored tidal volume exceeded set tidal volume, regardless of volume- or pressure-controlled ventilation. The overestimation in tidal volume was larger with smaller respiratory rate and with larger cardiogenic oscillation. In contrast, with the other ventilators, the discrepancy was small. CONCLUSIONS: Exhaled tidal volume is overestimated during mechanical ventilation when cardiogenic oscillation is large.

Models, Biological↗

Quantitative assessment of regional alveolar ventilation and gas volume using 13N-N2 washout and PET.

UNLABELLED: Measurement of alveolar volume (Va) and regional ventilation (a) is crucial to understanding the pathophysiology of acute lung injury and ventilator-induced lung injury. PET has previously been used as a noninvasive, quantitative method to assess a, but formal validation of this technique in experimental lung injury is lacking. This study aims to validate Va and a regional assessment with PET, using inhaled (13)N-N(2) in pigs. METHODS: Two normal and 2 oleic acid-injured pigs were tracheotomized, mechanically ventilated, and studied in 5 different levels of ventilation by changing respiratory rate. In each experimental condition, lungs were washed-in and then washed-out with (13)N-N(2) through an open circuit in the ventilator. Using this method, multiframe images were acquired with a dedicated PET camera. Regions of interest (ROIs) were drawn on each lung. Regional time-activity curves during washout were generated for each ROI and fitted to a mono- and a bicompartmental model. Validation of this method was performed in 2 ways. First, regional values of predicted Va (Va(emission)) were compared with regional volume obtained independently from density analysis on a transmission scan (Va(trans)). Second, regional values of predicted a were summed in each animal during each experimental condition and compared with minute-ventilation values set on the ventilator. RESULTS: The bicompartmental model best fitted the experimental values in normal (94.7% [62.2%-100.0%] (median [interquartile range]) of the ROIs) as well as in injured animals (90.7% [81.6%-97.4%] of the ROIs) (P = 0.49). Va(emission) significantly correlated with Va(trans) (R(2) = 0.89, P < 0.001) but exceeded Va(trans) by 10%. Finally, a strongly and positively correlated with minute-ventilation in both normal (R(2) = 0.96, P < 0.001) and injured (R(2) = 0.96, P < 0.001) animals. CONCLUSION: Measurement of (13)N-N(2) washout using PET is accurate to assess regional alveolar volume and ventilation during experimental acute lung injury.

Administration, Inhalation↗

Effects of serum of the rats ventilated with high tidal volume on endothelial cell permeability and therapeutic effects of ulinastatin.

BACKGROUND: With the widespread use of ventilators in treating critically ill patients, the morbidity of ventilator-induced lung injury (VILI) is increasing accordingly. VILI is characterized by a considerable increase in microvascular leakiness and activation of inflammatory processes. In this study we investigated the effects of inflammatory mediators in VILI rat serum on endothelial cytoskeleton and monolayer cellular permeability, as well as the therapeutic effect of ulinastatin, to explore the pathogenesis and the relationship between biotrauma and lung oedema induced by VILI. METHODS: Thirty healthy male Sprague-Dawley rats were randomly divided into three groups: group A (normal tidal volume ventilation), group B (high tidal volume ventilation) and group C (high tidal volume ventilation plus ulinastatin). The serum of each rat after ventilation was added to endothelial cell line ECV-304 medium for two hours to observe the effects of serum and/or ulinastatin on endothelial fibrous actin and permeability. RESULTS: Compared to rats ventilated with normal tidal volume, serum of rats ventilated with high tidal volume caused a striking reorganization of actin cytoskeleton with a weakening of fluorescent intensity at the peripheral filament bands and formation of the long and thick stress fibres in the centre resulting in endothelial contraction and higher permeability. Prior treatment with ulinastatin lessened the above changes significantly. The changes of permeability coefficient of endothelial permeability after group A, B or C rats serum stimulation were (6.95 +/- 1.66)%, (27.50 +/- 7.77)% and (17.71 +/- 4.66)% respectively with statistically significant differences (P < 0.05) among the three groups. CONCLUSIONS: The proinflammatory mediators in the serum of the rats given high tidal volume ventilation increases endothelial permeability by reorganizing actin cytoskeleton, and pretreatment with ulinastatin lessens the permeability by inhibiting of proinflammatory mediators.

Actins↗

Effects of PEEP on respiratory mechanics in patients with COPD on mechanical ventilation.

We studied the effects of positive end-expiratory pressure (PEEP) applied by the ventilator on respiratory mechanics in ventilated patients with chronic obstructive pulmonary disease (COPD). Airway pressures, relaxed expiratory flow-volume curves and end-expiratory volumes (EEV) were measured. In all patients investigated without PEEP applied by the ventilator, an intrinsic PEEP level (PEEPi) and a concavity in the flow-volume curve was present. Ventilator-PEEP caused a significant decrease in PEEPi in all patients (p less than 0.01). In patients in whom ventilator-PEEP exceeded PEEPi, significant increases occurred in airway pressures and EEV (p less than 0.05) and moreover the shape of the flow-volume curve was changing. In patients in whom the level of ventilator-PEEP was below the PEEPi level, no significant changes in airway pressures, EEV or flow-volume curves were found. We conclude: 1) PEEP applied by the ventilator can reduce PEEPi in ventilated patients with COPD without significant changes in airway pressures, EEV or flow-volume curves. 2) Expiratory flow-volume curves can be used to estimate the effects of ventilator-PEEP on EEV.

Aged↗

Hemodynamic effects of high-frequency jet ventilation.

The hemodynamic effects of high-frequency jet ventilation (HFJV) and conventional ventilation were compared in normovolemic and functionally hypovolemic dogs. In normovolemic animals, no differences in hemodynamic function were found among spontaneous ventilation, conventional ventilation, and HFJV. When venous return was impaired by 15 cm H2O PEEP, cardiac index and stroke index were 25% higher with HFJV than with conventional ventilation (P less than 0.05). In another study with PEEP, conventional ventilation was compared to spontaneous ventilation, HFJV synchronized to five different parts of the cardiac cycle, and asynchronous HFJV. Heart rate was 15% lower and mean arterial pressure was 26% lower with conventional ventilation than with HFJV modes (P less than 0.05). There were no differences between synchronous and asynchronous HFJV. These results indicate that hemodynamic dysfunction may be less likely with HFJV than conventional ventilation. No advantage of synchronizing jet pulsations to a specific part of the cardiac cycle could be demonstrated.

Airway Resistance↗

Monitoring ventilator function.

Maintenance of the patient-ventilator system is the primary role of the respiratory care practitioner in the intensive care unit. Patient-ventilator system checks should include monitoring the patient's response to ventilation, evaluating function of the ventilator, maintaining ventilator settings according to physician orders, setting appropriate alarms, maintaining the integrity of the ventilator circuit and humidifier, and documenting all of the above. The concept of ventilator checks should be expanded and thus, the name changed to patient-ventilator system check to emphasize the importance of evaluating the patient. This article reviews the rationale for performing patient-ventilator system checks and measurements.

Equipment Design↗

Evaluation of a modification of the Hudson demand valve in ventilated and spontaneously breathing horses.

Hypoxaemia commonly develops during general anaesthesia and in the recovery period in horses. The Hudson demand valve has been used to increase arterial PO2, but it has been found to increase airway resistance considerably when used during spontaneous ventilation. This paper evaluates a modification of the valve designed to reduce this resistance. The effects of the valve and its modification on arterial oxygen (PaO2), and carbon dioxide (PaCO2) tensions were evaluated in four ponies anaesthetised by a total intravenous technique. The valve increased PaO2 from 8.3 +/- 1.1 to 32.7 +/- 7.6 kPa during spontaneous ventilation and to 44.2 +/- 7.4 kPa during intermittent positive pressure ventilation. With the modification, the PaCO2 was increased to 9.0 +/- 2.5 kPa during spontaneous ventilation PaO2 was unchanged by the valve (7.2 +/- 0.4 kPa to 7.1 +/- 0.7 kPa) but it was reduced to 6.4 +/- 0.9 kPa with the modification. The valve was also evaluated in 20 clinical cases during their recovery from halothane anaesthesia. It increased PaO2 from 7.4 +/- 2.1 kPa to 17 +/- 18.3 kPa during spontaneous ventilation and from 8.0 +/- 1.8 kPa to 23.4 +/- 22.2 kPa during positive pressure ventilation. With the modification, PaO2 was increased from 7.8 +/- 1.4 kPa to 10.4 +/- 3.8 kPa during spontaneous ventilation and from 7.6 +/- 1.5 kPa to 14.8 +/- 8.4 kPa during positive pressure ventilation. During spontaneous ventilation PaCO2 was increased from 5.9 +/- 0.4 kPa to 6.2 +/- 0.6 kPa with the unmodified valve and from 6.3 +/- 0.5 kPa to 6.6 +/- 0.5 kPa with the modification.(ABSTRACT TRUNCATED AT 250 WORDS)

Anesthesia, General↗