Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Spectral Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85Linked to original sources

Infrared spectral analysis of extractables from poly(etherurethane urea) (PEUU) elastomers.

Poly(etherurethane urea) (PEUU) elastomers when employed as biomedical devices may be susceptible to extraction upon implantation. Four PEUU elastomers containing a single PEUU formulation, but varying in terms of their additives, were subjected to an in vitro extraction procedure. The additives in the PEUUs were Methacrol 2138 F at 5 wt% and Santowhite powder at 1 wt% levels. Only 1-2 wt% of the PEUUs was extractable with methanol. Fourier transform infrared spectroscopy (FT-IR) furnished qualitative and quantitative information on the extractables. The extractables consisted of a PEUU component that on the average was richer in soft segment than the bulk PEUU, and the two additives, Methacrol 2138 F and Santowhite powder.

Biocompatible Materials↗

Inappropriate sympathetic activation at onset of septic shock: a spectral analysis approach.

The autonomic cardiovascular control was investigated in 10 patients with septic shock, 10 patients with sepsis syndrome, and six tilted healthy subjects. Overall variability, high- and low-frequency components (AUC, HF, and LF, beats/min(2)/Hz or mm Hg(2)/Hz) from heart rate (HR), systolic (SBP) and diastolic (DBP) blood pressures spectra were obtained from 5-min recordings. LF(HR)/HF(HR) and the square root of LF(SBP)/LF(HR) (alpha) were used as indices of sympathovagal interaction and baroreflex control of the heart, respectively. Compared with tilted control subjects and patients with sepsis syndrome, septic shock is characterized by reduction in: (1) HR variability, i.e., decreased AUC(HR) (p = 0.007), LF(HR) (p = 0.002), and LF(HR)/HF(HR) (p = 0.0002); (2) DBP variability, i.e., decreased AUC(DBP) (p = 0.003) and LF(DBP) (p = 0.001), (3) alpha (p = 0.003). In septic shock, LF(HR)/HF(HR), alpha, and LF(DBP) correlated with mean blood pressure (r = 0.67, p = 0.04, r = 0.64, p = 0.03, and r = 0.88, p = 0.0008, respectively), and with plasma norepinephrine levels (r = -0.65, p = 0.03, r = -0.79, p = 0.006, and r = -0.69, p = 0.03, respectively). In conclusion, onset of septic shock is characterized by high concentrations of circulating catecholamines but impaired sympathetic modulation on heart and vessels, suggesting that central autonomic regulatory impairment contributes to circulatory failure.

Adult↗

Power spectral analysis of heart rate in elderly hypertensive subjects with or without silent coronary disease.

Much evidence indicates an involvement of the sympathetic nervous system in the genesis of silent myocardial ischemia. The authors assessed autonomic system activity by power spectrum analysis of heart rate variability in 21 elderly hypertensive men with and without angiographically confirmed coronary artery disease and compared the results with those from an age-matched control group. In the analysis an autoregressive algorithm was used to determine the power spectrum from an electrocardiographic recording of 512 consecutive RR intervals. The autonomic nervous system induces two distinct sinusoids: a low-frequency signal attributable to sympathetic activity and a high-frequency vagal response. In the hypertensive patients with coronary disease the authors also evaluated sympathetic activation after double-blind, placebo-controlled administration of metoprolol (100 mg/day), followed by amlodipine (10 mg/day), quinapril (20 mg/day), and amlodipine (5 mg/day) plus quinapril (10 mg/day).

Aged↗

Changes in cardiac autonomic activities in patients with syndrome X. A study of spectral analysis of heart rate variability.

The present study was designed to assess cardiac autonomic activities, coronary microvascular function, and their relationship in patients with syndrome X. Control of coronary blood flow is complex, and impaired coronary flow reserve has been attributed as the cause of myocardial ischemia in patients with syndrome X. It is unknown whether cardiac autonomic activities are altered in the presence of coronary microvascular dysfunction in patients with syndrome X. Eighteen patients with syndrome X were studied. Great cardiac vein flow was measured by the thermodilution method and the coronary flow reserve was determined by intravenous dipyridamole (0.56 mg/kg) infusion. Twenty-four-hour ambulatory electrocardiograms were obtained in a drug-free state. Another 14 age- and sex-matched normal subjects served as a control group. The amplitude (in ms) of ultralow (ULF), very-low (VLF), low (LF), and high (HF) frequency bands and total spectra of heart rate variability were measured for twenty-four-hour and every four-hour interval of the day.

Adult↗

Power spectral analysis of temporomandibular joint sounds in asymptomatic subjects.

Very little has been done to quantify temporomandibular joint (TMJ) sound amplitudes and background noise and to determine the spectrum from healthy TMJs. Thus, the aim of this study was to record acoustically the sounds emitted by healthy TMJs with and without mandibular movements, for determination of baseline spectra. TMJ sounds were recorded bilaterally from 40 subjects with healthy joints by means of a self-developed recording system using miniature capacitor microphones inserted into the earpieces of a medical stethoscope placed in the meatus of the auditory canal. The recordings were performed without mandibular movements and during three consecutive opening and closing movements. The signals were high-pass-filtered at 50 Hz, low-pass-filtered at 2 kHz, and analyzed by fast Fourier transform computation on a 1024-point window (fs = 5 kHz). The linearly weighted average baseline spectrum recorded without motion showed maximum values of 31 dBSPL (sound pressure level) with a standard error of +2 to -3 dB. The linearly weighted average movement spectrum had a peak of 66 dBSPL at 156 Hz and decreased almost linearly by about 40 dB/decade to 25 dBSPL at 2000 Hz with a standard error of +/- 2 dB. Thus, the TMJ sound spectrum of mandibular movements in asymptomatic subjects differed at low frequencies by up to 35 dB from the baseline spectrum in absence of motion.

Adolescent↗

Spectral analysis of demodulated ultrasound returns: detection of scatterer periodicity and application to tissue classification.

Ultrasound returns from tissue display variations in amplitude on several spatial scales. Although large-scale variations result from factors such as attenuation, variations on smaller scales are caused by tissue characteristics such as variations in scatterer spacing and reflectance. These small scale variations cause a corresponding variation in the amplitude of the ultrasound return. A simple and direct method for detecting and quantifying periodicity in these variations in the presence of attenuation is described. The radiofrequency ultrasound return is first demodulated by full-wave rectification. The normalized power spectrum of the demodulated return then yields an index that we call the relative Fourier energy. Both computer simulations and in vitro experiments were performed in order to study how relative Fourier energy performed in discriminating between periodic and random scatterer distributions. Computer simulations demonstrated significant differences between the returns from periodic and random scatterer distributions. Ultrasound returns from aortic tissue yielded a relative Fourier energy index that was significantly different between normal vs. atherosclerotic tissue (normal: 0.868 +/- 0.076, mean +/- s.d., fibrofatty plaque: 0.705 +/- 0.109, p < 0.01 vs. normal, calcified plaque: 0.753 +/- 0.078, p < 0.01 vs. normal). In contrast, no difference was found in comparisons of overall reflectance.

Aorta, Thoracic↗

Intraocular pressure variability in the anesthetized rat: a spectral analysis.

PURPOSE: Intraocular pressure (IOP) is a measure of the balance between the inflow and outflow of the aqueous humor, being in close relationship with the venous ocular blood flow. But the influence of the autonomic nervous system upon this variable is not well understood. One of the most frequently used mathematical tools for the evaluation of the autonomic nervous system in the frequency domain is the fast Fourier algorithm (FFT) applied to the analysis of heart rate (HR) and arterial blood pressure (BP). For these variables, a power spectrum has been built showing the major bands: very low frequency, lower frequency, and higher frequency (HF). The range of these bands depends on the animal species. In this study, the authors used FFT to analyze the variability of IOP in anesthetized rats. METHODS: BP and electrocardiogram were acquired at 2 KHz in all animals before and following muscle blockade and artificial ventilation at the same frequency as the spontaneous ventilation. Also, in this last condition, IOP was recorded before and after the application of atropine in the eye. RESULTS: Results show three bands in the IOP spectrum, a similar profile to those observed in the HR and BP spectra, with HF band modified after atropine application DISCUSSION: The discussion calls attention to the influence of the autonomic nervous system on IOP and suggests the possibility of clinical application of this methodology on diagnosis and therapeutic efficacy.

Animals↗

Developmental studies on EEG spectral analysis in mentally retarded children.

The EEG developmental characteristics of 36 mentally retarded infants were investigated by auto-power spectrum analysis. A significant positive correlation with age was found in the dominant frequency in all of the three regions, occipital, central, and frontal. A tendency for the generalized component to increase was found in 3- to 5-year-old subjects as compared with those aged 6 months to 1 year and 7 months. Developmental coherence characteristics could not be found. The peak components tended to show higher coherence values in the frontal-central relation than in the central-occipital and occipital-frontal ones.

Cerebral Cortex↗

Spectral analysis of wakefulness and REM sleep EEG in patients with sleep apnoea syndrome.

Neuropsychological investigations of patients with obstructive sleep apnoea syndrome (OSAS) have shown impairments in such basic functions as memory, attention and executive control. Since executive functions are known to be dependent on the integrity of the frontal lobe, it was hypothesized that OSAS may be associated with hypoxaemic frontal lobe dysfunction. To test this hypothesis, 21 apnoeic patients and 10 normal controls were studied with quantitative electroencephalographic (EEG) methods during rapid eye movement (REM) sleep, when most apnoeic events occur and during wakefulness. In apnoeic patients, EEG slowing in REM sleep was observed over frontal, central and parietal regions, while EEG slowing during wakefulness was observed over all cortical regions examined. A positive correlation was found between EEG slowing during wakefulness and oxygen desaturation during the night. Contrary to the hypothesis, these electroencephalographic changes were not localized only to the frontal region. This result may explain the wide range of neuropsychological deficits noted in patients with obstructive sleep apnoea syndrome, in addition to their poor performance in tasks of executive functioning.

Adult↗

EEG spectral analysis in schizophrenia.

Four channels of EEG (T4-T6, P4-02, T3-T5, P3-01) were recorded from several groups of control subjects and schizophrenia patients on analogue tape. They were later digitized and analysed by computer; power spectra were computed for 30 second epochs of EEG per channel; eyes closed, eyes open. No difference between normal controls and neurotic in-patients was apparent. An acute schizophrenic group had less alpha power, this change being confined largely to the temporal areas. A chronic outpatient sample showed less alpha and beta power, while chronic long-stay schizophrenic patients had an excess of delta power. The changes in both chronic patient groups were diffuse rather than local.

Acute Disease↗

Development and maturation of the autonomic nervous system in premature and full-term infants using spectral analysis of heart rate fluctuations.

The changes in the power spectra of heart rate (HR) fluctuations, in particular the total power (within 0.02-2.0 Hz) and the power in the low- (0.02-0.2 Hz) and high- (0.2-2.0 Hz) frequency ranges, were computed from the ECG and respiratory signals of 59 premature and full-term infants. The objective of the study was to investigate the development and maturation of the autonomic nervous system from the first day of extrauterine life to several weeks of postnatal age. The study population was divided into four age groups. Group A: seven 1-d-old premature infants with gestational age of 34-35 wk. Group B: 28 premature infants 7-49 d old with a conceptional age of 34-35 wk. Group C: seven 1-d-old full-term infants of 39-41 wk gestation. Group D: six premature infants 35-97 d old with a conceptional age of 39-40 wk. Mean HR (+/- SEM) of groups C and D combined, i.e. 135 +/- 2 bpm, was significantly lower compared with groups A and B, i.e. 152 +/- 2 (p < 0.01). The mean (+/- SEM) of the low- to high-frequency power ratio obtained from the HR power spectrum decreased progressively from 71 +/- 31 in group A to 34 +/- 8 in group B, 16 +/- 3 in group C, and 17 +/- 2 in group D. The mean low to high ratio for the combined groups C and D, 17 +/- 1, was significantly lower compared with the combined group A and B, i.e. 44 +/- 9 (p < 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)

Autonomic Nervous System↗

PERIODIC AIR-BREATHING BEHAVIOUR IN A PRIMITIVE FISH REVEALED BY SPECTRAL ANALYSIS

The ventilatory patterns of air-breathing fish are commonly described as 'arrhythmic' or 'irregular' because the variable periods of breath-holding are punctuated by seemingly unpredictable air-breathing events (see Shelton et al. 1986). This apparent arrhythmicity contrasts with the perceived periodism or regularity in the gill ventilation patterns of some fish and with lung ventilation in birds and mammals. In this sense, periodism refers to behaviour that occurs with a definite, recurring interval (Bendat and Piersol, 1986). The characterisation of aerial ventilation patterns in fish as 'aperiodic' has been generally accepted on the basis of qualitative examination and it remains to be validated with rigorous testing. The bowfin, Amia calva (L.), is a primitive air-breathing fish that makes intermittent excursions to the air&shy;water interface to gulp air, which is transferred to its well-vascularized gas bladder. Its phylogenetic position as the only extant member of the sister lineage of modern teleosts affords a unique opportunity to examine the evolution of aerial ventilation and provides a model for the examination of ventilatory patterns in primitive fishes. To establish whether Amia calva exhibit a particular pattern of air-breathing, we examined time series records of aerial ventilations from undisturbed fish over long periods (8 h). These records were the same as those used to calculate average ventilation intervals under a variety of experimental conditions (Hedrick and Jones, 1993). Their study also reported the occurrence of two distinct breath types. Type I breaths were characterised by an exhalation followed by an inhalation, whereas type II breaths were characterised by inhalation only. It was also hypothesized that the type I breaths were employed to meet oxygen demands, whereas the type II breaths were used to regulate gas bladder volume. However, they did not investigate the potential presence of a periodic ventilatory pattern. We now report the results of just such an analysis of ventilatory pattern that demonstrates a clear periodism to air-breathing in a primitive fish.

Journal Article↗