Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “STEAM”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85Linked to original sources

Moisture transfer from stopper to product and resulting stability implications.

Since the stability of a freeze-dried product is often sensitive to the level of moisture, control of residual moisture by attention to the secondary drying phase of the freeze-drying process is of considerable importance. However, several reports in the literature as well as our own experience suggest that low residual moisture immediately after manufacture does not ensure low moisture throughout the shelf life of the product. Equilibration of the product with moisture in the stopper can lead to significant increases in product water content. This research is a study of the kinetic and equilibrium aspects of moisture transfer from stopper to product at 5 degrees C, 25 degrees C, and 40 degrees C for two amorphous materials: vancomycin (highly hygroscopic) and lactose (moderately hygroscopic). Stoppers are 13 mm butyl rubber (#1816, West Co.) slotted freeze-drying stoppers which were studied: (a) "U"-with no treatment; (b) "SV1"-steam-sterilized followed by 1 hr vacuum drying; and (c) "SV8"-steam sterilized followed by 8 hrs vacuum drying. No evidence was found for moisture transmission through the stopper. Rather, the product moisture content increases with time and reaches an apparent equilibrium value characteristic of the product, amount of product, and stopper treatment method ("SV1" much greater than "U" greater than "SV1"). As a first approximation, the rate of approach to "equilibrium" depends only on temperature (t1/2 approximately 10 months at 5 degrees C to approximately 4 days at 40 degrees C) with the "equilibrium" water content being independent of temperature. The "equilibrium" moisture content increases as the dose decreases and is larger for vancomycin than for lactose. The "equilibrium" moisture contents range from 5.0% (25 mg vancomycin, "SV1" stoppers) to 0.68% (100 mg lactose, "SV8" stoppers).

Biological Products↗

Assessment of the effectiveness of dental sterilizers using biological monitors.

This study was undertaken to evaluate the effectiveness of steam, chemical vapor, and dry heat sterilizers, over a three-year period, in dental operatories subscribing to the University of British Columbia's sterilization monitoring service. A total of 4,579 sterilizer loads were tested. The results demonstrated an overall failure rate of 4.4 per cent. Individual failure rates for each type of sterilizer were: chemiclaves, 4.9 per cent; steam autoclaves, 2.3 per cent; and dry heat ovens, 7.9 per cent. In 38 per cent of these cases, the reasons for failure could be attributed to a definite cause.

Bacillus subtilis↗

Effects of packaging, equipment, and storage time on energy used for reheating beef stew.

Energy used to reheat 3 kg of a standard beef stew to 74 degrees C was measured to determine (a) the benefits of a retort pouch packaging processing system that keeps food microbially safe at room temperature compared with a system that packages food in a plastic bag that requires refrigerated storage; (b) the most economical form for reheating (in bulk in bags, in bulk out of bags, or in portions); (c) the most economical equipment for reheating (convection oven, infrared oven, microwave oven, compartment steamer, or steam-jacketed kettle); and (d) the influence of storage time (7, 28, or 85 days). Energy used for reheating the retort product was 18,883.7 British thermal units (BTU) compared with 31,035.6 BTU for the plastic bag product. Reheating in portions used 6,857 BTU; reheating in bulk out of bag used 23,419 BTU; and reheating in bulk in bag used 64,247 BTU. The order of least to greatest energy use for equipment was microwave oven, 324 BTU; infrared oven, 5,406 BTU; convection oven, 11,399 BTU; steam-jacketed kettle, 30,713 BTU; and steamer, 51,412 BTU. Storage time in the plastic bag significantly (P less than .05) affected initial product temperature and the energy required for reheating; this was not true for the retort product. Our findings indicate that microwave heating, heating in portions rather than in larger quantities, refrigerated storage of 7 days instead of 28 days, and use of retort pouch products achieve the least energy cost in reheating a product such as beef stew.

Cooking↗

[Study on extraction methods of volatile oil from Mosla soochowensis].

OBJECTIVE: To study the different extraction methods of the volatile oil from Mosla soochowensis Matsuda and to determine the optimum extraction method. METHODS: The yields and the chemical constituents of volatile oil were used to compare the different extraction methods including SFE-CO2, steam distillation and organic solvent (petroleum ether) extraction. RESULTS: The yield of volatile oil by means of SFE-CO2 was 3.46%, which was higher than others. The quality of the oil by means of SFE-CO2 and steam distillation was better. Based on the result of GC-MS, the constituents of volatile oil were similar. It was mainly the methyleugenol, accounted for about 42%. The second was monocyclic terpene, such as bornene, dihydrocarvon, carvacrol, accounted for about 27%. The third was sesqutierpenoids, such as nerolidene etc, accounted for about 19%. CONCLUSION: SFEE-CO2 is the optimum extraction method of the volatile oil from Mosla soochowensis Matsuda.

Carbon Dioxide↗

[Extraction and determination of volatile constituents in leaves of Eucalyptus citriodora].

The volatile constituents in leaves of Eucalyptus citriodora, including oil fraction and water-soluble fraction, were extracted and determined. Oil fraction of volatile components was obtained through steam distillation. Ether was used as the solvent to extract the water-soluble fraction of volatile compounds from the liquid left after steam distillation in order to know the quantity and constituents of volatile compounds dissolved in the water phase. The oil yield in the oil fraction was 1.36%, and the oil yield in the water-soluble fraction was 0.48% (both on fresh weight basis). Both oil fraction and water-soluble fraction were analyzed by gas chromatography-mass spectrometry (GC-MS) method. The results showed that 37 compounds (97.36%) in the oil fraction and 10 compounds (82.05%) in the water-soluble fraction were identified. There were 12 hydrocarbon compounds and 25 oxygenated compounds identified in oil fraction. The major constituents in oil fraction were citronellal (57.00%), followed by citronellol (15.89%) and citronellyl acetate (15.33%). Alcohols dominated the compounds in water-soluble fraction. cis-p-Menthane-3, 8-diol (53.43%) and trans-p-menthane-3, 8-diol (16. 48%) were found to be the major compounds, which have the activity to repel insects. It is concluded that the comprehensive utilization value of leaves of Eucalyptus citriodora was enhanced owing to the extraction of water-soluble volatile components.

Acyclic Monoterpenes↗

[GC-MS analysis of volatile oil from the ear of Schizonepeta tenifolia Briq].

Volatile oil was extracted from the ear of Schizonepeta tenifollia Briq. by supercritical carbon dioxide extraction and steam distillation, then GC-MS was used to analyse their components and determine the content. There were 41 components identified from products of supercritical carbon dioxide extraction, while 32 from those of steam distillation. The content of the main component, pulegone, was also different in the two extracts. It showed that the two extractions have differences in component and content to a certain extent.

Chromatography, Supercritical Fluid↗

Radiation protection performance indicators at the Nuclear Power Plant Krsko.

Nuclear power plant safety performance indicators are developed "by nuclear operating organisations to monitor their own performance and progress, to set their own challenging goals for improvement, and to gain additional perspective on performance relative to that of other plants". In addition, performance indicators are widely used by regulatory authorities although the use is not harmonised. Two basic performance indicators related to good radiation protection practice are collective radiation exposure and volume of low-level radioactive waste. In 2000, Nuclear Power Plant Krsko, a Westinghouse pressurised water reactor with electrical output 700 MW, finished an extensive modernisation including the replacement of both steam generators. While the annual volume of low-level radioactive waste does not show a specific trend related to modernisation, the annual collective dose reached maximum, i.e. 2.60 man Sv, and dropped to 1.13 man Sv in 2001. During the replacement of the steam generators in 2000, the dose associated with this activity was 1.48 man Sv. The annual doses in 2002 and 2003 were 0.53 and 0.80 man Sv, respectively, nearing thus the goal set by the US Institute of Nuclear Power Operators, which is 0.65 man Sv. Therefore, inasmuch as collective dose as the radiation protection performance indicator are concerned, the modernisation of the Krsko nuclear power plant was a success.

Humans↗

Monitoring aldehyde production during frying by reversed-phase liquid chromatography.

Acrolein (2-propenal) and other low molecular weight aldehydes (LMWAs) formed by degradation of the frying medium (triglycerides) were monitored by liquid chromatography (LC) during preparation of fried items. LMWA contents of coatings from codfish and of doughnuts and their volatiles that codistill with steam are monitored by trapping the vapors and distillate from the food matrix in a 2,4-dinitrophenylhydrazine solution. The resulting hydrazones are partitioned from the aqueous phase, first into isooctane and then into acetonitrile for LC analysis. The hydrazones are separated and quantified on a C18 reversed-phase column with acetonitrile-water as the mobile phase. LMWAs are confirmed by gas chromatography/mass spectrometry. No difference was found in LMWA content in coatings from fish fillets fried at 182 or 204 degrees C. Cake doughnuts were higher in acrolein content than yeast-raised doughnuts prepared under similar conditions. Freshness of the frying medium, frying time, and batch size did not seem to influence LMWA production from doughnuts. Results indicated that most of the LMWAs formed codistilled with steam during frying rather than remaining with the food item.

Acrolein↗

In vitro periodontal ligament fibroblast attachment to plasma-cleaned titanium surfaces.

The objective of this research was to characterize the in vitro cellular behavior of fibroblast-like cells derived from rat periodontal ligament on commercially pure titanium surfaces which were sterilized by a variety of treatments. Following standard surface preparation protocols, the Ti specimens were sterilized by either steam autoclaving, exposure to ethylene oxide gas, exposure to ultraviolet light, or plasma-cleaning in argon for either one min or five min. Fibroblast-like cells in serum-supplemented media were incubated on the various Ti specimens for up to two h. In general, the levels of cell attachment for plasma-cleaned surfaces were significantly higher than those for steam-sterilized surfaces, but were significantly lower than the attachment levels for both the ultraviolet-treated surfaces and the tissue culture plastic control. The duration of plasma cleaning itself did not have a significant effect on the percentage of cell attachment at any time period. SEM evaluations indicated that by two h, the cellular morphology was different on the variously treated specimens. These studies indicate that the method of sterilization following implant surface preparation can affect the initial in vitro biological events of cell attachment and spreading.

Animals↗

Sterilization beneath rings on dental instruments.

This study determined the effectiveness of standard methods of instrument sterilization beneath instrument rings. Sets of three types of dental instruments were contaminated with known amounts of bacterial spores (Bacillus stearothermophilus or Bacillus subtilis). Instrument rings were placed over the contamination and the instruments processed through standard cycles in a steam autoclave, an unsaturated chemical vapor sterilizer, a standard dry heat sterilizer, an ethylene oxide gas sterilizer or a 2.0% alkaline glutaraldehyde solution. Controls consisted of spore-contaminated instruments without rings that were not processed through any sterilizing method and that were processed through each sterilizing method. All instruments and their associated rings were cultured for the presence of live spores. The results indicate that the reliability of sterilization beneath the instrument rings used is greatest if the ringed instruments are processed through a steam autoclave or an unsaturated chemical vapor sterilizer.

Bacillus subtilis↗

[Occupational injuries caused by breakages of hoses].

During the period 1.1.1984-31.12.1986, 77 accidents caused by breakages of hoses or connections in connection with snap-couplings were notified to the Danish Directorate of National Labour Inspection. These consisted of 33 (42.9%) accidents in connection with employment pressurized air hoses, 25 (32.5%) accidents in connection with employment of steam hoses or hoses with warm water and 19 (24.7%) accidents while employing hoses with chemicals. Accidents with pressurized air resulted in bruising on the neck, head, eyes and upper limbs. Accidents with steam hoses caused scalds scattered over the entire body. Accidents with hoses containing chemicals were mainly responsible for corrosive injuries to the eyes. Prophylactic measures which would probably have prevented approximately 85% of the abovementioned injuries are suggested.

Accidents, Occupational↗

[Frequency of food intake of dentulous and complete denture wearers].

The study was carried out on 1466 subjects, whose ages ranged from 20 to 80 years of age, of whom 1181 were dentulous and 285 were complete dentures. We studied the frequency with which the 1466 cases partook of food. The results were as follows: 1) Ingested foods were classified into 10 groups along with the frequency with which they were ingested on a yearly seasonal basis. Food groups were classified as follows: vegetables, grain, sea food, beans, meat, seaweed, potatoes, fruits, etc. 2) The Ingested foods of the dentulous group were similar to those of the complete denture wearers. 3) In all age groups the foods most ingested were: steamed rice, wakame, tofu, bread, scallions, Japanese omelette, and tomatoes. 4) The younger subjects (20 to 39 years) statistically ate significantly lower amounts of steamed rice than did the older age groups. 5) The younger generation ate more meat, while the older groups ate more sea food.

Adolescent↗

[Thermodynamic principles and physiologic criteria for the use of heat engines to drive the ventricles of an artificial heart].

The authors review the thermodynamic bases and physiological limitations of the applicability of thermal engines for driving artificial heart ventricles. Show that the thermodynamic characteristics of Stirling and Brighton cycles do not make it possible to effectively use cycle-based engines in the artificial heart. A steam engine operating in accordance with the Rankine cycle may be regarded as an optimum type engine for that purpose. Demonstrate that according to the rules of physiology, use should be made of a separate driving of artificial heart ventricles by two independently operating steam engines. Provide the characteristics of the Soviet artificial heart "MIKRON" acceptable for implantation into the orthotopic position.

Equipment Design↗

Effect of inhaling heated vapor on symptoms of the common cold.

A double-blind, randomized study tested the efficacy of steam (technically, heated, humidified air) inhalation in the treatment of common cold symptoms. Two 20-minute treatments spaced 60 to 90 minutes apart were given at the time of enrollment. The active device (Rhinotherm, Netzer-Sereni, Beer Yaacov, Israel) delivered 40 L/min of saturated air at 40 degrees C to 42 degrees C, while the identical-appearing placebo delivered 2 L/min of ambient air at 20 degrees C to 24 degrees C. There were 34 patients in the placebo group and 32 in the active group. Significant improvements in the placebo-treated group were obtained on subjective symptom scores for nasal congestion, nasal drainage, and sneezing on isolated days during the treatment period (40%, vs 25% on day 3, 71% vs 60% on day 6, and 100% vs 67% on day 7). Improvement in nasal resistance as measured by rhinomanography was better in the placebo group than in the active group on day 7 (11% vs -6%). Our study demonstrated no beneficial effects of steam inhalation on common cold symptoms.

Adolescent↗

[Physical and biophysical aspects of high-energy intracardiac electric discharges. I. The discharge bubble].

Endocavitary discharge produces an electrical spark at the end of the probe. This in turn produces a plume of steam which lasts for about ten milliseconds and which subsequently acts like a cavitation bubble. This phenomenon is well known in the branch of physics dealing with dynamics and fluids, and should be subjected to rapid kinetic recording. It may make it possible to explain various barotraumas which are observed during the discharge. However, the plumes of steam produced by the discharge have some highly specific features which are due to the fact that the discharge is usually produced using a monopole in an electrolyte. In addition, the shape of the electrode also affects the formation of the bubble. This results in a description of the cavitation bubble produced by the discharge as the "discharge bubble".

Biophysical Phenomena↗

[Effect of various environmental illumination modalities on the muricidal behavior of male Wistar rats].

The aim of this research is to study the effects of different modalities of environment lighting on the appearance of the muricide behaviour in the Wistar male Rat. Indeed it is known that the exposition of Rats in environment to continuous light determine a reduction of the cerebral content of serotonin, which is known to unchain the muricide behaviour in naturally not muricide Rats. The animals are kept in different situations of environment lighting: 1) L/D = the natural light of the day alternated with the dark of the night; 2) L/L sodium = continuous light emitted by a sodium steam lamp; 3) L/L neon = continuous light issued from fluorescent neon tubes. The muricide behaviour is studied by comparison Rat-Mouse. The results obtained show that the continuous sodium steam light (L/L, sodium) remarkably increase the percentage of the animals which become muricide compared to the control animals bred in natural environment with a normal succession day-night (L/D). On the contrary the percentage is remarkably reduced compared to the control animals in Rats of the same group when these animals are exposed to continuous light issued from fluorescent neon tubes (L/L, neon).

Aggression↗

[The determination of ammonia in rumen fluid].

The following 3 methods of NH3 determination were compared to each other for accuracy, on the basis of their results: microdiffusion acidimetric NH3 analysis, photometric NH3 analysis, using bivalent potassium tetra-iodomercurate, and steam distillation/acidimetric NH3 analysis. The results obtained from steam distillation at pH 7.6 were found to agree with those recorded from microdiffusion. However, photometric NH3 determination, using Nessler reagent, yielded overestimated values due to interference by other rumen juice substances.

Ammonia↗

[Influence of flaking of wheat on the intestinal flow of nitrogen in the cow].

Six Friesian heifers fed a 75% wheat diet were used in a 6 x 2 x 2 cross-over design. Rolled and steam-flaked wheat were compared. Starch gelatinization failed to increase the DM intestinal flow. Decreased N solubility produced by steam-flaking was associated with an increase in non-NH3-N flow (+/- 12%; P less than 0.05).

Animal Feed↗