Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Reference Standards”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85Linked to original sources

Determination of iodine in seafood by inductively coupled plasma/mass spectrometry.

A method was developed for determination of total iodine content in different standard reference materials (SRMs) and seafood products by inductively coupled plasma/mass spectrometry (ICP/MS). If iodine is present as iodide and nitric acid is used in the wet digestion system, the observed signal is not stable when iodine is measured by ICP/MS at m/z 127. To stabilize the iodine signal, 3% ammonia solution (1 + 1, v/v) was added to the digest. The limit of quantitation of the method, defined as 6 times the standard deviation in the blank solution (n = 20) was estimated to be 15 mg/kg (using 0.2 g dry mass and a dilution factor of 50). The precision, expressed as repeatability of the iodine concentration, varied between 3.2 and 12% in SRMs, with concentrations of 4.70-0.17 mg/kg dry matter. The described method was compared with a method using tetramethylammonium hydroxide extraction. Both methods showed good precision and trueness by analyses of SRMs. The 2 methods were used to determine iodine in seafood from the Barents Sea, the Norwegian Sea, and the North Sea. The results showed great variation between different fish species as well as between individuals within a species. The lowest values of iodine were recorded in muscle of ling (Molva molva) with a mean of 0.07 mg/kg fresh weight and a variation between 0.03 and 0.11 mg/kg fresh weight. The highest values were found in cod (Gadus morhua) from the Barents Sea, with a mean of 2.5 mg/kg and a variation between 0.7 and 12.7 mg/kg fresh weight.

Ammonia↗

Atmospheric pressure ionization time-of-flight mass spectrometry coupled with fast liquid chromatography for quantitation and accurate mass measurement of five pharmaceutical drugs in human plasma.

The quantitative determination and accurate mass measurement of five tricyclic amine pharmaceutical drugs (doxepin, desipramine, imipramine, amitriptyline and trimipramine) fortified in human plasma within a per sample run time of 18 s was accomplished by atmospheric pressure ionization (API) time-of-flight (TOF) mass spectrometry using a turboIonspray liquid chromatography/mass spectrometry (LC/MS) interface coupled with high-performance liquid chromatography (HPLC). The relatively short HPLC separation (18 s) was achieved using a short C18 column (15 x 2.1 mm i.d.) with a high aqueous mobile phase maintained at a flow-rate of 1.4 ml min(-1). An acquisition speed of 0.2 s per spectrum accommodates these fast separation conditions. This method employs a one-step liquid-liquid extraction procedure to isolate the five tricyclic amines from biological matrix components The overall extraction recovery was 75% for desipramine and >90% for the other four tricyclic amines. The lower level of quantitation was 1-2 ng ml(-1) for each compound. The calibration curve was linear from 2 to 100 ng ml(-1) for desipramine and from 1 to 50 ng ml(-1) for the other four tricyclic amines. A deuterated internal standard, imipramine-d3, was used for all five tricyclic amines. Acceptable intra- and inter-assay precision (1.0-17.7%) and accuracy (0.2-14.5%) were obtained. The linear dynamic range was extended to 200 based on a software upgrade for correcting ion current detection saturation. The accurate masses of the five tricyclic amines were determined by on-line LC/TOFMS analyses of biological extracts using two-point internal mass calibration. This was done by infusing a reference standard, Jeffamine D230, post-column into the HPLC effluent. All results showed a mass error not greater than 9 ppm for all the target compounds. These results were obtained from both synthetic mixtures when as little as 100 pg were injected or extracts of spiked human plasma samples with analytical concentration as low as 5 ng ml(-1). The factors influencing accurate mass measurements are discussed.

Antidepressive Agents, Tricyclic↗

Chemical synthesis of 7- and 8-dehydro derivatives of pregnane-3,17alpha,20-triols, potential steroid metabolites in Smith-Lemli-Opitz syndrome.

Pregnane-3,17 alpha,20-triols bearing unsaturation at delta(7), delta(8), delta(5,7), or delta(5,8) have been tentatively identified as steroid metabolites in Smith-Lemli-Opitz syndrome (SLOS). Starting with 17 alpha-hydroxypregnenolone diacetate, we have synthesized 13 unsaturated C(21) triols by four different routes in one to four steps. These multifunctional steroids were prepared by a series of regio- and stereoselective transformations chosen to minimize facile olefin isomerization and 17-deoxygenation. The results include a study of stereoselectivity in the reduction of 17 alpha-hydroxy-20-ketosteroids, an alternative method for reducing diethyl azodicarboxylate adducts of delta(5,7) steroids, and an efficient oxidation-isomerization of a delta(5,7) steroid using cholesterol oxidase. The 13 triols and their synthetic precursors were fully characterized by 1H and 13C nuclear magnetic resonance (NMR) spectroscopy. The NMR data, together with molecular modeling, indicated unanticipated conformational heterogeneity for two synthetic intermediates, 17 alpha-hydroxypregna-4,7-diene-3,20-dione and 17 alpha-hydroxy-5 beta-pregn-7-ene-3,20-dione. The unsaturated C(21) triols are useful as reference standards to study adrenal steroid production in SLOS and to develop methods for pre- and postnatal diagnosis of this congenital disorder.

Magnetic Resonance Spectroscopy↗

Monitoring of ventilation during exercise by a portable respiratory inductive plethysmograph.

OBJECTIVES: To evaluate the accuracy of a portable respiratory inductive plethysmograph that allows the monitoring of ventilation without airway instrumentation during exercise in unrestrained subjects. DESIGN: Validation of a novel technique by comparison to a reference standard. PARTICIPANTS: Thirty-one subjects, including 20 healthy volunteers, 6 patients with COPD, and 5 patients with congestive heart failure. INTERVENTIONS: Participants performed progressive treadmill exercise to exhaustion. Ventilation was monitored by a novel battery-powered, miniaturized, and calibrated respiratory inductive plethysmograph. Inductance sensors encircling the rib cage and abdomen were built into an elastic body garment. A pneumotachograph attached to a mouthpiece served as the reference method. MEASUREMENTS AND RESULTS: Breath-by-breath comparisons between the inductance plethysmograph and pneumotachograph over the course of progressive exercise to exhaustion revealed no significant bias of respiratory cycle time, tidal volume (Vt), and minute ventilation. The corresponding limits of agreement (bias +/- 2 SDs) were +/- 6%, +/-17%, and +/- 17%, respectively, for 2,480 breaths. Comparisons of mean values averaged over 20 breaths revealed improved limits of agreement of +/- 1% for cycle time, and +/- 7% for tidal volume and minute ventilation, respectively, for 124 comparisons. Agreement between methods was similar for patients and healthy subjects. Among the patients, maximal minute ventilation was lower, and breathing was more rapid and shallow than in healthy subjects. Obstructive lung disease was associated with a shorter duty cycle than heart failure. CONCLUSIONS: The portable respiratory inductive plethysmograph accurately estimates ventilation during treadmill exercise, and identifies differences in breathing patterns among patients with pulmonary or cardiac diseases and healthy subjects. This unobtrusive monitoring technique is promising for application in ambulatory patients.

Adult↗

Optimization of storage conditions for diluted working solutions of porcine factor VIII and performance of the Bethesda assay for the determination of antiporcine FVIII inhibitor titres.

The use of porcine factor VIII (FVIII) (Hyate:C, Ipsen) has proven to be very successful in treating patients with FVIII inhibitors. The best way to predict the usefulness of porcine FVIII therapy, and/or to estimate the appropriate treatment dose in a given patient, is to measure the patient inhibitor titre against porcine FVIII with the Bethesda assay, using porcine FVIII as the source of FVIII in the assay. The goals of the present study were to (1) find the optimal storage temperature, diluent and concentration for a working solution of porcine FVIII to be used as the source of FVIII for the porcine Bethesda assay, (2) assess the reliability of the labelled FVIII units in the preparation of such working solutions of porcine FVIII and (3) compare the inhibitor titres determined by the Bethesda assay using both porcine and human standard reference curves for measuring residual FVIII. The results of the present study demonstrate that a ready-to-use working solution of 1 U mL(-1) of Hyate:C diluted in human FVIII deficient plasma, either containing or deficient in von Willebrand factor antigen, is stable for up to 12 months, at -20 degrees C. The preparation of the 1 U mL(-1) working solution could be reliably calculated based on the units indicated on the vial label. Finally, using the human standard curve yields similar results to using the porcine standard curve for measuring any titre of allo- or auto-antibody against FVIII in the Bethesda assay, using Hyate:C as the source of FVIII. These findings are of practical value when performing a porcine FVIII-based Bethesda assay.

Animals↗

AUDILAB: a knowledge-based quality audit simulator for testing laboratories.

In order to obtain an accreditation, a laboratory must be prepared to provide a point-by-point check of various activities against the chosen reference standard, both from a general point of view and in relation to details of application. This paper describes AUDILAB, a computerized simulator accessible by network, able to provide testing laboratories with realistic quality audits performed in a customized way. AUDILAB establishes a detailed list of strengths (compliance with corresponding requirements of established standards) and weaknesses (improvements needed for laboratory's accreditation). The standard used by AUDILAB is the EN 45001 "General criteria for the operation of testing laboratories". A preliminary validation has already been completed. AUDILAB became operational in September 1993.

Artificial Intelligence↗

Analytical profile of 4-methylthioamphetamine (4-MTA), a new street drug.

The analytical properties for a new street drug, 4-methylthioamphetamine (4-MTA), are presented. This new compound was found in tablets sold on the illicit market in the Netherlands and Switzerland in 1997 and 1998. The intermediate 1-(4-methylthiophenyl)-2-nitropropene was also found in a clandestine laboratory in the Netherlands in January 1997. In this study, reference standards were prepared and characterized. The ultraviolet, infrared and nuclear magnetic resonance spectral properties as well as the chromatographic and mass spectrometric (MS) data are reported.

Amphetamines↗

qNMR--a versatile concept for the validation of natural product reference compounds.

The validation of reference compounds for natural products is a domain of the same physico-chemical methods that are used for their isolation, especially those techniques involving coupled high-resolution chromatography. Acknowledging the great problem of co-eluting impurities contained in the 'biogenetic cocktail' of a plant extract, there is a strong demand for non-chromatographic alternatives in the quality assessment of reference compounds. Because of this, the concept of qNMR is introduced as a versatile tool based on qualitative and quantitative 1H-NMR allowing the precise and simultaneous determination of both the compound content as well as the amount and nature of the impurities. As opposed to measuring carbons, 1H-NMR benefits from much higher sensitivity and is far more versatile for routine analysis with respect to time and cost. Since quantification of impurities is reliant upon their identification and, therefore, limited by knowledge about their structure, the concept emphasizes the high demand for qualitative reference dossiers including quality NMR data for profiling potential impurities which may be analogues, isomers, or degradation or oxidation products of the reference compounds. The qNMR concept is developed with focus on its potential in the certification and quality control of reference compounds. Taking into account published work in the field of quantitative NMR, selected natural products are analysed in order to elaborate suitable experimental parameters and to obtain preliminary validation data. The method is discussed with respect to sensitivity, precision and selectivity. Typical relative errors are found to be below 2% for the quantification of both the major analyte and the minor impurities even when the latter are contained at the 1% level only. Documentation of the conformity of signal integration and precision is based on measurements of a certified reference standard. Determination of the natural 13C isotope is suggested as an elegant method of validation because the content values could be reproduced with errors below 1%. The qNMR concept offers a rapid and efficient way to assess the purity of natural products in a single analytical step without the need of performing multiple analyses, while still offering the option to retain the substance. Thus, qNMR pays tribute to the increasing demands in reference compound certification, but also holds out the prospect of easy access to the valid characterisation of natural products tested in vitro or in vivo for their biological and pharmacological effects.

Biological Factors↗

Amnesic shellfish poisoning toxins in shellfish: estimation of uncertainty of measurement for a liquid chromatography/tandem mass spectrometry method.

A liquid chromatography/mass spectrometry (LC/MS) method for amnesic shellfish poisoning toxins in shellfish was developed and validated. Tissue homogenate (4 g) was extracted with 16 mL methanol-water (1 + 1, v/v). Dilution into acetonitrile-water (1 + 9, v/v) was followed by C18 solid-phase extraction cleanup. Domoic acid (DA) and epi-domoic acid were determined by LC/MS/MS with electrospray ionization and multiple reaction monitoring. External calibration was performed with dilutions of a certified reference standard. Advantages of this method include speed, lower detection limits, and a very high degree of specificity. The LC/MS response was highly linear, and there were no significant interferences to the determination of DA. Formal method validation was performed on 4 shellfish species. Fortification studies gave recoveries (mean +/- SD; n = 24) of 93 +/- 14% at 1 mg/kg, and 93.3 +/- 7.6% at 20 mg/kg over all the species. Analysis of a mussel certified reference material showed the bias as < 5%. The limits of detection and quantitation were 0.15 and 0.5 mg/kg, respectively. Routine application of the method over 4 months gave a recovery for the QC sample (1 mg/kg fortified blank mussel homogenate) run with each batch of 88.9 +/- 5.5% (mean +/- SD; n = 37). The total uncertainty of measurement results were estimated as 0.12 (12%) at 0.25-5 mg/kg and 0.079 (7.9%) at 5-50 mg/kg. The major contribution to the uncertainty was the repeatability of the LC/MS determination, probably arising from subtle matrix effects.

Amnesia↗

Purity profiles of pteroylglutamate reference substances by high-performance liquid chromatography.

High-performance liquid chromatography (HPLC) in the reversed-phase mode was used for the purity analysis of three pteroylglutamic acid-type reference substances (folic acid, leucovorin calcium, and methotrexate). The influence of the pH of the mobile phase on the separation of an artificial mixture of six pteroylglutamic acid derivatives and three potential impurities was studied. Results of purity analysis of current lots of USP reference standards are reported. A better separation of methotrexate from its major impurities was achieved by using a standard buffer, rather than an ion-pairing mobile phase. A separation of methotrexate and its biologically inactive 7-isomer is reported.

Chromatography, High Pressure Liquid↗

[Inter-institute variations in International Normalized Ratio and thrombotest].

Oral anticoagulant therapy is effective for reducing the risk of thromboembolic events in patients with atrial fibrillation or other heart diseases. However, the intensity of oral anticoagulation therapy required in high risk patients, especially in Japanese patients, to achieve the best balance between the prevention of thromboembolic events and bleeding complications remains unclear. The multicenter study of Toyama Warfarin Rational Dosage (TOWARD) was started in 1996 to determine the optimal level of anticoagulant therapy. This study investigated the relationship between values of thrombotest (TT) and International Normalized Ratio (INR) measured from the same samples to clarify inter-institute variations. The relationship between TT and INR was not linear but hyperbolic. Changes of INR to TT are relatively small in the TT range of more than 20% as compared with the range of 20% or less. There were considerable inter-institute variations of TT, and the coefficient of variation (CV) was 0.16 and 0.24 in the low level and high level anticoagulation samples, respectively. However, the variations became significantly small when the same reference was used. The CV of INR was 0.12 and 0.08 in the high level and low level anticoagulation samples, respectively, and very similar with the control samples without anticoagulation (0.11). The variation was small when INR was obtained from the international sensitivity index (ISI) of thromboplastin less than 1.5. TT is widely used for monitoring oral anticoagulant therapy in Japan, and is an excellent system with little inter-institute variation when a standard reference is offered. Since INR has been established as an international monitoring system, the use of INR measured with thromboplastin of small ISI is recommended for monitoring.

Anticoagulants↗

The importance of the quality of water in Limulus Amebocyte Lysate tests.

Commercial pharmaceutical waters were evaluated regarding their interference in the chromogenic Limulus Amebocyte Lysate (LAL) test. Two of the four tested waters strongly inhibited the U.S. Reference Standard Endotoxin, while a Control Standard Endotoxin was less affected. The inhibitory effect could be mimiced by adding trace amounts of certain metal ions to a non-interfering water. In conclusion, the water used in the LAL test must be chosen with great care.

Endotoxins↗

Additives to biological substances. IV--Lyophilization conditions in the preparation of international standards: an analysis by high-performance liquid chromatography of the effects of secondary desiccation.

Many International Standards, Reference Preparations and Reference Reagents are routinely prepared by lyophilization in the presence of 'inert' carriers followed by an extensive period of secondary desiccation. In this study we have used high-performance liquid chromatography (HPLC) to analyse the effects of lyophilization and secondary desiccation on initial degradation and subsequent stability of a model protein, insulin. Secondary desiccation was found to promote a reaction of the insulin with a carrier consisting of non-volatile buffer salts and a sugar. Secondary desiccation did not improve the stability of the insulin as determined by accelerated thermal degradation and analysis using the Arrhenius equation. We conclude that careful consideration needs to be given, on a case-by-case basis, to the selection of the procedures for the preparation of International Standards, particularly those ampouled in the absence of carrier proteins and intended for physicochemical analysis such as HPLC.

Chromatography, High Pressure Liquid↗

Biological assay for tissue kallikrein: comparison with the synthetic substrate S2266.

A highly sensitive biological assay for tissue kallikrein is described, using human kininogen as substrate; and quantitation, by radioimmunoassay, of generated kinins. Using purified human urinary kallikrein as a reference standard we have correlated the kininogenase activity of kallikrein with amidase activity as measured by cleavage of the synthetic substrate S2266.

Animals↗

Improved high-performance liquid chromatographic method for the combined analysis of phospholipase, lipoxygenase and cyclooxygenase activities.

We report herein an improved method for the high-performance liquid chromatographic separation and analysis of eicosanoids formed during the stimulation of human platelets in vitro with collagen. Since the products of interest, excepting arachidonic acid, contain hydroxyl groups (one to several), our method involves the conversion of the hydroxyl groups into acetates (pyridine/acetic anhydride) after derivatization with anthryl diazomethane (ADAM) rendering the compounds with much decreased polarity for separation on a reversed-phase column. This procedure is superior to that involving ADAM esters only, i.e. with free hydroxyl groups, as it leads to the excellent separation of the desired compounds from each other and from extraneous peaks observed due to the ADAM reagent and sharpens the peak of thromboxane. We have successfully applied the method to investigate the formation of thromboxane B2 and 12-hydroxyheptadecatrienoic acid (HHT) (products of cyclooxygenase and thromboxane A2 synthase), 12-hydroxyeicosatetraenoic acid (12-HETE, a 12-lipoxygenase product) and arachidonic acid (AA, product of phospholipase A2) formed during the in vitro aggregation of human platelets induced by collagen. A correlation between the inhibition of aggregation by aspirin and thromboxane/HHT formation was observed. All four compounds can be chromatographed in a single run. We employed prostaglandin B1 (PGB1) as internal reference standard to quantify the products. The method is useful to investigate selectivity of drugs which may affect either or all of these enzyme pathways at the same time.

Blood Platelets↗

Synthesis of 3-(2-pyridyl)-2-substituted-quinazolin-4(3H)-ones as new analgesic and anti-inflammatory agents.

A new series of 3-(2-pyridyl)-2-substituted-quinazolin-4(3H)-ones were synthesized by reacting the amino group of 2-hydrazino-3-(2-pyridyl)-quinazolin-4(3H)-one with a variety of aldehydes and ketones. The starting material 2-hydrazino-3-(2-pyridyl)-quinazolin-4(3H)-one was synthesized from 2-aminopyridine. The title compounds were investigated for analgesic, anti-inflammatory and ulcerogenic index activities. While the test compounds exhibited significant activity, compound 2-(1-ethylpropylidene)-hydrazino-3-(2-pyridyl)-quinazolin-4(3H)-one (AS2) showed moderate analgesic activity and compound 2-(1-methylbutylidene)-hydrazino-3-(2-pyridyl)-quinazolin-4(3H)-one (AS3) showed realistic anti-inflammatory activity when compared to the reference standard diclofenac sodium. Interestingly the test compounds showed only mild ulcerogenic side effect when compared to aspirin.

Analgesics↗

Screening for basic drugs in equine urine using direct-injection differential-gradient LC-LC coupled to hybrid tandem MS/MS.

A rapid, selective and robust direct-injection LC/hybrid tandem MS method has been developed for simultaneous screening of more than 250 basic drugs in the supernatant of enzyme hydrolysed equine urine. Analytes, trapped using a short HLB extraction column, are refocused and separated on a Sunfire C(18) analytical column using a controlled differential gradient generated by proportional dilution of the first column's eluent with water. Independent data acquisition (IDA) was configured to trigger a sensitive enhanced product ion (EPI) scan when a multiple reaction monitoring (MRM) survey scan signal exceeded the defined criteria. The decision on whether or not to report a sample as a positive result was based upon both the presence of a MRM response within the correct retention time range and a qualitative match between the EPI spectrum obtained and the corresponding reference standard. Ninety seven percent of the drugs targeted by this method met our detection criteria when spiked into urine at 100 ng/ml; 199 were found at 10 ng/ml, 83 at 1 ng/ml and 4 at 0.1 ng/ml.

Animals↗