Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Pulsatile Flow”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85Linked to original sources

Phantom testing of peripheral artery. Absolute blood flow measurement with digital arteriography.

A technique to measure absolute arterial blood flow in ml/min has been developed utilizing software programs with high-speed digital recording for the off-line analysis of intra-arterial injections of contrast medium. Measurements of pulsatile flow in a phantom for a physical flow model showed that calculations with the final upgrades were within 10% of known flow, using a recording rate of 30 frames/s, a diameter tubing of 5 mm, and flow rates of 300 to 400 ml/min. Quantitative absolute flow of a peripheral artery such as the internal carotid artery may be obtained during routine cerebral arteriography for comparison with anatomic data.

Angiography↗

Pulsed-injection method for blood flow velocity measurement in intraarterial digital subtraction angiography.

The pulsed-injection method for measuring the velocity of blood flow in intraarterial digital subtraction angiography is described. With this technique, contrast material is injected at a pulsing frequency as high as 15 Hz, so that two or more boluses can be imaged simultaneously. The velocity of flow is determined by measuring the spacing between the boluses and multiplying it by the pulsing frequency. Results of tests with phantoms correlate well with flow measurements obtained with a graduated cylinder for velocities ranging from 8 to 60 cm/sec. The potential of the method for time-dependent velocity measurement has been demonstrated with simulated pulsatile flows.

Angiography↗

Regional vascular influences of vasoactive intestinal polypeptide.

Vasoactive intestinal polypeptide (VIP) has powerful vasodilating effects, shown by a striking conductance increase especially in the vertebral artery (+100%), the left descending coronary artery (+200%), the left gastric artery (+550%), the superior pancreaticoduodenal artery (+200%), and the gastroduodenal artery (+220%). The conductance increase was also significant in the common and the proper hepatic artery (+60% and 50%, respectively). Total peripheral conductance was progressively increased by 45%; arterial pressure was reduced by 20%. Blood flow was assessed with non-cannulating electromagnetic flow sensors in anesthetized dogs. VIP was injected in a brachial vein at intervals of 1 min in amounts of 1-1024 ng X kg-1, following a logarithmic scale. The pulsatile flow and pressure signals were analog-digital-converted and processed simultaneously by a computer program to obtain mean flow (ml X min-1) and mean pressure (mmHg) values for every 3 sec. The hemodynamic data were presented as conductances. No response was observed in the inferior mesenteric artery, the renal artery, or the femoral artery. Major vasoactivity thus occurred in cerebral, cardiac, gastric, hepatic, and pancreatic regions.

Animals↗

Changes in umbilical artery, middle cerebral artery, and aorta blood flow Doppler waveform pulsatility indices after funisocentesis.

This study evaluates the effect of funisocentesis on umbilical artery, fetal cerebral artery, and aortic circulation. The pulsatility index in the umbilical artery, fetal middle cerebral artery, and descending aorta was measured by pulsed Doppler ultrasonography before and after 41 diagnostic funisocenteses. Percutaneous umbilical artery blood sampling was associated with a significant decrease in umbilical artery pulsatility index (mean -0.132, standard deviation 0.259, P = 0.002) and in middle cerebral artery pulsatility index (mean -0.143, standard deviation 0.260, P = 0.001). The decline in resistance to flow of the umbilical artery (r = 0.340, P = 0.029) and middle cerebral artery (r = 0.457, P = 0.002) was correlated with gestational age at sampling. These findings suggest that alterations in the waveforms from both the umbilical and the fetal cerebral circulations can be induced by fetal blood sampling.

Aorta, Thoracic↗

A comparison between laser interferometric measurement of fundus pulsation and pneumotonometric measurement of pulsatile ocular blood flow. 1. Baseline considerations.

PURPOSE: Several methods have been proposed for the investigation of the human choroidal circulation. The aim of the present study was to compare laser interferometric measurements of cardiac synchronous fundus pulsations with pneumotonometric measurements of intraocular pressure pulse and pulsatile ocular blood flow in humans. METHODS: The association between fundus pulsation amplitude as assessed with laser interferometry and pulse amplitude (PA) and pulsatile ocular blood flow (POBF) as assessed with pneumotonometry was investigated in 28 healthy subjects. Additionally, we investigated the distribution of fundus pulsation amplitude (FPA) in a region of -15 degrees to +15 degrees around the macula (n = 18) and the influence of accommodation paralysis with cyclopentolate on FPA (n = 10). RESULTS: There was a high association between FPA and PA (r = 0.86, p < 0.001) and FPA and POBF (r = 0.70, p < 0.001). Fundus pulsations in the macula were significantly smaller than in the optic disc, but significantly larger than those in peripheral regions of the retina. Administration of cyclopentolate did not influence FPA. CONCLUSIONS: On the basis of the strong correlation between laser interferometric measurements of FPA and pneumotonometric measurements of PA and POBF, we conclude that the FPA is a valid index of pulsatile choroidal perfusion in humans.

Adult↗

Influence of arterial pulse and reflected waves on blood pressure and cardiac function.

An integrated view of the role of arterial blood pressure in cardiovascular physiology should consider both the steady (mean blood pressure) and pulsatile (systolic, diastolic, and pulse pressures) components. This brief overview describes the important factors influencing these components, with emphasis on the consequences of arterial stiffening. In addition to their conduit function, arteries also perform a cushioning function that transforms the pulsatile flow generated by contraction of the left ventricle into steady flow at the periphery. Arterial compliance is a principal determinant of arterial blood pressure and is both pressure dependent and affected by vascular biomechanics. Other important factors that affect the steady and pulsatile components of blood pressure include ventricle performance, peripheral resistance, pulse wave velocity, and the timing of pulse wave reflections. Ageing and hypertension are important factors that contribute to reductions in arterial compliance. Important functional effects of this are that both the amplitude of the arterial pulse wave and pulse wave velocity increase, causing an early return of reflected waves from the periphery to the aorta. This may boost aortic and left ventricular pressures during systole at the expense of diastolic pressure, which is reduced. Studies have shown that stiffening of arteries and the associated increase in systolic and pulse pressures are important cardiovascular risk factors. Patients with an increased risk of cardiovascular events associated with such changes should be identified and receive appropriate therapeutic interventions.

Arteries↗

Increased intraarticular pressure reduces blood flow to the femoral head.

Hemarthrosis leading to increased intracapsular pressure after an undisplaced femoral neck fracture is suspected to impair blood flow to the femoral head and may lead to osteonecrosis. We hypothesized that an increase of intraarticular pressure would reversibly decrease the blood flow to the femoral head. Eleven patients having surgical dislocations for treatment of femoroacetabular impingement were included in this study. Saline was injected into the intact intracapsular space while the blood flow to the femoral head was recorded using laser Doppler flowmetry. Injection of saline resulted in an increase in the intracapsular pressure. The injected volume of normal saline until disappearance of the pulsatile signal was on average 20 mL (range, 10-35 mL) with an average intraarticular pressure of 58 mm Hg (range, 25-88 mm Hg). Aspiration of the joint resulted in a return of the pulsatile flow. Hemarthrosis after undisplaced intracapsular fractures of the femoral neck are likely to cause an increase in intracapsular pressure. Decompression of the hematoma to reduce the intracapsular pressure is strongly advocated to optimize blood flow to the femoral head in acute fractures.

Femur Head↗

Quantitative measurement of normal and hydrocephalic cerebrospinal fluid flow using phase contrast cine MR imaging.

Measurements of the cerebrospinal fluid (CSF) flow using phase contrast cine magnetic resonance (MR) imaging were performed on a phantom, 12 normal subjects and 20 patients with normal pressure hydrocephalus (NPH). The phantom study demonstrated the applicability of phase contrast in quantitative measurement of the slow flow. The CSF flows of the normal subjects showed a consistent pattern with a to-and-fro movement of the flow in the anterior subarachnoid space at the C2/3 level, and they were dependent on the cardiac cycle in all subjects. However, the patients with NPH showed variable patterns of the CSF pulsatile flow and these patterns could be divided into four types according to velocity and amplitude. The amplitudes of each type were as follows: type 0 (n = 1), 87.6mm; type I (n = 2), 58.2mm (mean); type II (n = 6), 48.0 +/- 5.0mm (mean +/- SEM); and type III (n = 11), 19.9 +/- 1.8mm (mean +/- SEM). The decrease of the amplitudes correlated to a worsening of the clinical symptoms. After the shunting operation, the amplitude of to-and-fro movement of the CSF increased again in the patients with NPH who improved clinically. Some of the type III cases were reclassified type II, I and 0 and also one of the type II cases changed type I after the shunting operation. We conclude that the phase contrast cine MR imaging is a practically and clinically applicable technique for the quantitative measurement of the CSF flow.

Adolescent↗

Noninvasive hemodynamic evaluation in selection of amputation level.

Various noninvasive techniques of hemodynamic evaluation have been used to determine the optimal level of amputation. Noninvasively obtained measurements of pressure and blood flow in the lower extremity have been found to be reliable in predicting the probable healing of an amputation. In patients with severely calcified noncompressible arteries, noninvasive electromagnetic flowmeter measurements of peak pulsatile flow provide a more accurate indication of the vascular status of the patient than do blood pressure measurements which, in such patients, frequently exceed 300 millimeters of mercury. Skin thermistor thermometry does not appear to be applicable in patients with extensive severe ischemia of the leg. The need for a reliable method of determining the lowest possible level of amputation is well recognized. Such factors as wound edge bleeding and clinical judgment too often lead to above the knee amputation when, frequently, a more distal amputation could have been possible. Our experience has shown that noninvasive techniques for hemodynamic evaluation are a valuable aid to clinical judgment in determining accurately the lowest level for successful limb amputation.

Amputation, Surgical↗

Effects of drugs on the negative (backflow) component of velocity patterns in the dog aorta.

Using an accurately calibrated flowmeter in the descending thoracic aorta of the dog, a study was made of alterations in aortic flow patterns following intravenous and intra-arterial injections of vasoactive drugs. When injected distal to the flowmeter, vasopressors caused marked backflow while vasodilators raised the level of the lowest portion of the pulsatile flow curve. When injected into the brachiocephalic artery, vasopressors prevented the development of a significant negative component whereas vasodilators caused the appearance of backflow, or augmented that which was already present. All acute elevations or decreases in peripheral resistance due to drugs were accompanied by increases in the negative or "backward" phase of flow in diastole. A significant negative flow component was noted only during these acute adjustments. A temporary differential in resistances of the upper and lower portions of the arterial circulation protected cerebral and coronary blood flow during acute haemodynamic adjustments.

Animals↗

Radial artery wall shear stress evaluation in patients with arteriovenous fistula for hemodialysis access.

It has been extensively documented that changes in blood flow induce vascular remodeling and this phenomenon seems to be correlated to the shear forces imposed on the vessel wall by motion of blood. Wall shear stress, the tractive force that acts on the endothelium, has been shown to influence endothelial cell function. To study changes in wall shear stress that develop on the vessel wall upon changes of blood flow, we set up a technique that allows estimation of shear stress in the radial artery of patients on chronic hemodialysis therapy. The technique is based on color-flow Doppler examination of the radial artery before and after surgical creation of radiocephalic fistula for hemodialysis. Calculation of time function wall shear stress and blood flow rate in the radial artery is performed on the basis of arterial diameter, center-line velocity waveform and blood viscosity, using a numerical method developed according to Womersley's theory for pulsatile flow in tubes. The results presented confirm that the model developed is suitable for calculation of the wall shear stress that develops in the radial artery of patients before and after surgical creation of an arteriovenous fistula for hemodialysis. This methodology was developed for characterization of wall shear stress in the radial artery but may be well applied to other vessels that can be examined by echo-Doppler technique.

Arteriovenous Shunt, Surgical↗

Viable extracardiac total right heart bypass: technical considerations and mid-term results.

BACKGROUND: Direct connection of both caval veins to the pulmonary arterial system would be the ideal right heart bypass by virtue of elimination of prosthetic material and extensive atrial suture lines. However, it can be applied only to selected patients with peculiar anatomical arrangements. We decided to perform total extracardiac right heart bypass using pedicled in situ pericardium in situations when a direct connection was not possible. METHODS: A cohort of five patients, aged 3.5, 4, 10, 10 and 31 years, respectively, with complex cyanotic congenital heart diseases were candidated to extracardiac total cavopulmonary connection using viable in situ pericardium. Aortic cross-clamp was completely avoided in all patients. RESULTS: There was no early or late death. Postoperatively, all patients are in functional class I and in normal sinus rhythm at a mean follow-up of 30 months (S.D.=+/-19 months). Postoperative serial echocardiograms revealed wide, unrestricted anastomoses, unobstructed venous flow to both pulmonary arteries with cardiac pulsations and respiratory variations in the pulmonary arteries due to compressible lateral tunnel. Cavopulmonary angiograms (n=5) in late postoperative period have demonstrated a smooth, nonturbulent, somewhat pulsatile flow without pressure gradient. CONCLUSIONS: The technical advantages and haemodynamic benefits of this operation are encouraging. A longer follow-up is needed to confirm the early results, especially late atrial dysrrhythmias, pulmonary venous obstruction, thromboembolic complications and growth of the conduit.

Journal Article↗

[Noninvasive measurement of cardiac output using two-dimensional Doppler echocardiography and analysis of sources of error].

The purpose of this study was (1) to analyze the factors responsible for errors in the two-dimensional Doppler echographic measurements of cardiac output (C.O.) and (2) to establish a noninvasive method for measuring C.O. The subjects were 50 cardiac patients who had neither aortic valve disease nor intracardiac shunts. The C.O. was calculated using the following formula: C.O. (l/min) = mean flow velocity (cm/sec) x pi(aortic ring diameter/2)2 (cm2) x 60/10(3) Left ventricular ejection flow velocity was recorded in the center of the aortic ring from the apical approach. Mean velocity was calculated by integration of instantaneous mean velocity in the ejection phase divided by the cardiac cycle length, and was corrected by the Doppler incident angle. The inner diameter of the aortic ring was measured in the parasternal long-axis view at the time of the maximum ejection flow velocity. The following results were obtained: 1. Sources of error in the measurement of cardiac output. 1) Accuracy of instantaneous mean velocity calculating circuit: This calculating circuit was accurate in model experiments using pulsatile flow. 2) Effect of high-pass filter: In model circuits, application of high-pass filter overestimated flow velocity. The higher the cut-off frequency of the high-pass filter, the larger the overestimation. This was probably due to the parabolic flow velocity profile in the circuit. 3) Flow velocity profile in the aortic ring: The flow velocity profile seemed to be flat in the aortic ring except near the anterior aortic wall. Therefore, the effect of the high-pass filter was considered to be negligible in case of clinical application. 4) The effects of shift and size of sample volume: The location of sample volume relative to the aortic valve ring shifted about 7 mm during systole. However, the shift and size of sample volume seemed to have little effect on the measured C.O., because the flow velocity profile was nearly flat in the aortic ring. 5) Ultrasound beam incident angle: From a practical viewpoint, it was necessary to set an incident angle of less than 50 degrees for minimizing the error. We were able to set the angle within 50 degrees in all but one of patients. 6) Diameter of the aortic ring: Two-dimensional echographic measurement of the aortic ring diameter was not so accurate; it seemed to become a major source of error in the calculation of C.O.(ABSTRACT TRUNCATED AT 400 WORDS)

Adult↗

Optimization of hepatocyte spheroid formation for hepatic tissue engineering on three-dimensional biodegradable polymer within a flow bioreactor prior to implantation.

We hypothesize that in vitro conditioning of hepatocytes within biodegradable poly-L-lactic acid (PLLA) polymer matrices prior to implantation may increase hepatocyte survival and function after transplantation. The purpose of this study was to optimize the culture conditions of hepatocytes in a pulsatile flow bioreactor. PLLA discs were seeded with rat hepatocytes in a concentration of 2.5, 5, 10, 20 and 40 x 10(6) cells/ml. Seeded discs were exposed to recirculated perpendicular flow of 0, 7, 15, 24, 32, 52 ml/min of supplemented Williams' Medium E and harvested after 6 days in flow culture. Only under flow conditions the hepatocytes formed spheroidal aggregates (SphA) of 50-260 microm in diameter with a liver-like morphology and active metabolic function. The number of SphA was examined by phase contrast microscopy and the reductive enzyme function of the hepatocytes was tested using MTT. Hematoxylin and eosin histology showed vital hepatocytes within the SphA less than 200 microm in diameter but central necrosis in the SphA exceeding this size. Immunohistochemical staining confirmed albumin production of hepatocytes within the SphA. The optimal cell seeding concentration was 10 x 10(6) cells/ml with a flow speed of 24 ml/min. SphA of hepatocytes cultured with this flow bioreactor method may prove useful as a functional unit for tissue engineering of an in vivo liver substitute.

Albumins↗

In vitro study of FFR, QCA, and IVUS for the assessment of optimal stent deployment.

We tested whether fractional flow reserve (FFR) discriminates between suboptimally and optimally deployed stents. Latex tubes (diameter solidus in circle = 4 mm) with diameter stenosis 40% (n = 3), 50% (n = 3) and 60% (n = 3) were tested in a pulsatile flow system, using water. Measurements were done at baseline (n = 9; FFR/QCA) and after suboptimal (SOD; 3-mm balloon at 8 atm) and optimal (OD; 4 mm balloon at 16 atm) deployment of a 35-mm stent (n = 6; FFR/QCA/IVUS). Varying Q from 150 to 50 ml/min increased FFR by 2-7%. Conversely, at 100 ml/min, FFR increased by only 0.8% from SOD to OD (P < 0.05). Extrapolating data to blood flow, the gain in FFR from SOD to OD is less than 5% for Q = 100 ml/min, while FFR may increase by 15-20% by changes in blood flow from 50 to 150 ml/min. We conclude that IVUS and QCA are more appropriate for the assessment of optimal stent deployment.

Blood Flow Velocity↗

Improved accuracy and consistency in T1 measurement of flowing blood by using inversion recovery GE-EPI.

Problems associated with techniques currently used to measure the T1 of flowing blood are evaluated and a method to improve the consistency and repeatability of measurements is presented. Similar to some currently used techniques, the pulse sequence employs a nonselective adiabatic inversion pulse followed by a series of ECG-gated gradient echo EPI (echo planar imaging) images to obtain images where the blood (fluid) signal exhibits a T1-dependent inversion recovery signal from which the spin lattice relaxation constant (T1) of the flowing fluid can be measured. The new method combines curve fitting with a measure of the curve null point to acquire more accurate and consistent T1 values. Simulation and experimental results show that this combined fitting-nulling method is more stable and consistent in measuring the T1 of flowing fluid. The feasibility of temperature measurement of a flowing fluid based on the temperature dependence of the T1 of water protons is shown in this paper. ECG gating is used to reduce the effects of cyclic intensity changes for measurement of T1 in pulsatile flowing blood.

Blood Flow Velocity↗

Local haemodynamics of arterial bypass graft anastomoses.

One of the main causes of failure of expanded polytetrafluoroethylene (PTFE) bypass grafts used in the lower limbs is the development of myointimal hyperplasia (MIH). Clinical studies show that higher patency rates can be obtained with the use of an autologous vein cuff (the Miller cuff) interposed between the graft and artery. The reasons for the improved performance are still unclear, but preliminary studies suggest that the change in local haemodynamics due to the cuff geometry may be the significant factor rather than the presence of autologous material. If this is the case, then PTFE grafts can be produced with an integral cuff, i.e. a precuffed graft, with similar haemodynamic patterns to that of the Miller cuff. In this paper, two different types of precuffed graft are presented and their flow patterns are compared with those recorded in the Miller cuff and the conventional end-to-side anastomosis. The haemodynamic studies were carried out using optically clear silicone rubber models under simulated in vivo pulsatile flow conditions. Flow structures similar to those observed in the Miller cuff were seen in the precuffed grafts.

Anastomosis, Surgical↗

Doppler-derived percentage systolic window and the quantitation of arterial stenosis.

Peak systolic frequency (PSF) and percentage systolic window (%SW) are spectral parameters used to characterize poststenotic flow velocity patterns. The PSF, obtained using a continuous-wave (CW) Doppler velocimeter, has been used more frequently, however, in the quantitation of carotid occlusive disease. The authors have employed a microprocessor-driven pulsatile flow model to evaluate more completely the relationship between stenosis and the %SW. Using an 8 MHz CW Doppler probe, the Doppler-shifted frequencies were recorded at 1, 2, 3, 4, and 5 diameters distal to a variable, nonaxisymmetric stenosis, which reduced the cross-sectional area (CSA) 25, 40, 50, 60, 70, 85, and 97 per cent. Four sets of observations were made and the %SW derived using a spectrum analyzer. At one diameter from the stenosis, the relationship between the %SW (Y) and the reduction in CSA (X) is best described by two first-order regressions (Y = MX + B). The slope of the relationship from 0 to 60 per cent reduction in CSA is nearly flat, -0.052, while there is a significant (P less than 0.05) decrease in the slope, -1.538, when the CSA is further reduced from 60 to 97 per cent. Beyond 1 diameter, the relationship is best described by a single linear regression, the gradual slope of which does not permit clinically useful comparisons. These data explain the lack of strong correlation between CSA and %SW when the data are evaluated over the entire range of stenoses. However, they do indicate that the %SW may be a useful correlate if it is obtained within one diameter of the stenosis.

Arterial Occlusive Diseases↗