Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PLASMA SUBSTITUTES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85Linked to original sources

Liquid storage of miniature boar semen.

The effects of liquid storage at 15 degrees C on the fertilizing ability of miniature pig semen were investigated. Characterization of ejaculated semen from 3 miniature boars was carried out. Semen volume and pH were similar among these boars. In one of the boars, sperm motility was slightly low, and sperm concentration and total number of sperm were significantly lower than in the others (P < 0.01). Seminal plasma of the semen was substituted with various extenders (Kiev, Androhep, BTS and Modena) by centrifugation and semen was stored for 7 days at 15 degrees C. Sperm motility was estimated daily at 37 degrees C. For complete substitution of seminal plasma, Modena was significantly more efficient than the other extenders (P < 0.001) in retaining sperm motility. Semen from each of the 3 miniature boars that had been stored for 5 to 7 days at 15 degrees C in Modena was used for artificial insemination of 15 miniature sows. The farrowing rates were 100, 100 and 60%, and litter sizes were 6.4 +/- 1.5, 5.8 +/- 0.8 and 5.0 +/- 1.0 for each boar semen, respectively. The boar that sired the smallest farrowing rate was the same one that showed lower seminal quality with respect to sperm motility, sperm concentration and total number of sperm. These results suggest that miniature boar semen can be stored for at least 5 days at 15 degrees C by the substitution of seminal plasma with Modena extender.

Animals↗

Capillary electrophoresis for monitoring the effects of plasmapheresis: a feasibility study.

Plasmapheresis is an established method to treat patients with large monoclonal gammopathies (M-components) that increases the blood viscosity. During plasmapheresis the patient plasma is substituted with a mixture of saline, albumin and normal plasma. The treatment results in a reduction of the M-component in the circulation. Plasmapheresis causes changes in several proteins, which makes monitoring by nephelometric or turbidimetric analysis of specific proteins less suitable. Quantification of paraproteins by nephelometric assays are also known to be associated with technical problems. An alternative could be agarose gel electrophoresis but this method is too slow to permit monitoring during the plasmapheresis. Capillary electrophoresis of plasma proteins can be performed in less than 10 min. We have used the CAPILLARYS capillary electrophoresis system (Sebia, Paris, France) to monitor the effect of plasmapheresis treatment on 22 occasions. The mean reduction in M-component size was 51%, range 33-61%. Capillary electrophoresis is a rapid and inexpensive method that could be used to monitor the effect of plasmapheresis during the actual treatment.

Blood Protein Electrophoresis↗

Association between atrial natriuretic peptide and cyclic GMP in hypertension and in chronic renal failure.

This study has examined the association between circulating atrial natriuretic peptide (ANP), plasma cyclic GMP and urinary cyclic GMP in relation to hypertension and reduced renal function in 30 normotensives, in 30 patients with essential hypertension and in 22 patients with stable dialysis-independent chronic renal failure (CRF). Plasma ANP was significantly raised (about two-three-fold) in the CRF group compared with the hypertensive and normal groups; plasma cyclic GMP was also significantly raised in the CRF group (median group values: 4.6, 5.8 and 11.0 pmol/ml, respectively, for the normal, hypertensive and CRF groups). There were no significant differences in urinary cyclic GMP between the normotensives and hypertensives but urinary cyclic GMP was significantly reduced in the patients with CRF (median group values: 407.1, 450.9 and 247.8 pmol/min for the normal, hypertensive and CRF groups, respectively, P < 0.001). In the subjects with CRF, the clearance of cyclic GMP was reduced in proportion to the clearance of creatinine, but there was no significant difference in the fractional excretion of cyclic GMP (median group values: 78.1% in the normal group, 78.9% in the hypertensive group and 70.2% in the CRF group). In all groups, there was no association between circulating ANP and urinary cyclic GMP: By contrast, there was a positive association between plasma ANP and plasma cyclic GMP (r = 0.39 P < 0.001) that was independent of blood pressure or renal function. These results demonstrate that while a substantial amount of urinary cyclic GMP originates from the glomerular filtrate, to some extent, raised plasma ANP also contributes to the circulating levels of cyclic GMP. However, plasma cyclic GMP cannot be taken as a direct substitute for plasma ANP.

Adult↗

Use of plasma protein fractions as serum substitutes for in vitro cell culture.

Fractions produced during routine production of human plasma protein concentrates using cold ethanol precipitation have been tested for their ability to support animal cell growth in vitro. A mouse-mouse hybridoma cell line, ES-6, which secretes a monoclonal antibody (mab) to human group A red blood cell antigen, has been used as a model. Fraction 4-1 protein has been found to be effective at 0.5-1.0 g/l in RPMI 1640 and has supported growth of ES-6 for 18 months, both growth and mab. production being comparable with that achieved in 10% foetal calf serum. Fraction 4-1 protein has been shown to contain albumin, transferrin, alpha-1 antitrypsin and immunoglobulin. It is reported to be a source of somatomedin C. The immunoglobulin content can be reduced. Other mouse and rat hybridomas, human mab. producing lymphoblastoid cells, Namalva and HEP-2 cells have grown well in medium supplemented with Fraction 4-1 protein.

Animals↗

[Effect of plasmapheresis with substitution by dextran solutions on hemostatic parameters in patients with ischemic heart disease].

Plasmapheresis on a continuous blood flow fractionator to remove 1,200-2,000 ml plasma and substitute for the same values of dextran solutions was employed in the multi-modality treatment of 25 patients with Functional Classes II-IV exertional angina and myocardial infarction. Plasma and thrombocyte hemostatic parameters were examined just before and 24 and 48 hours after plasmapheresis. The analysis of the baseline data revealed that hemostatic changes were directly related to the severity of a disease in the patients and there was a correlation between the increased platelet aggregability and the elevated levels of fibrin-monomeric complexes. Plasmapheresis along with substitution of removed plasma for dextran solutions was accompanied by a profound hypocoagulative effect, as evidenced by plasma and thrombocyte hemostatic parameters. In addition, in patients with baseline high values of platelet aggregability plasmapheresis resulted in its decrease, whereas in those with baseline low values, it led to its increase.

Adult↗

Peritoneal accumulation of infused stroma-free hemoglobin. Potential toxicity of an oxygen-carrying substitute.

The efficacy of stroma-free hemoglobin (SFH) as an oxygen-carrying red blood cell substitute in shock and trauma remains inconclusive. A major problem is the retention of sufficient intravascular persistence. The sites and mechanisms for clearance of SFH or its chemically modified variants are not well characterized. Capillary leakage has been reported. Any significant leak into the peritoneal cavity may be toxic, especially if bacteria are present. The present study quantitates peritoneal accumulation of SFH and chemically modified adenosine triphosphate (ATP)-SFH following a 50% exchange transfusion in rats. m-Dansyl cadaverine, an endocytotic blocking agent, was studied for its ability to alter accumulation of hemoglobin in the peritoneum. Differences in renal clearance corresponded to differences in vascular halflife of SFH (90 minutes) and ATP-SFH (210 minutes). Peritoneal leakage was not related to vascular persistence. We found that MDC significantly decreases the peritoneal accumulation of ATP-SFH but not that of SFH. We also noted that MDC neither inhibits nor alters renal clearance of either hemoglobin variant. Total peritoneal leakage is, at most, 4% of infused SFH at four hours. Molecular size and charge might be factors important in hemoglobin transport from the vasculature to the peritoneum.

Adenosine Triphosphate↗