Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Models, Anatomic”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85Linked to original sources

The intrinsic and extrinsic arterial supply to the proximal phalanx of the hallux.

The hallux is subject to numerous surgical procedures and very little is known about its blood supply. Arteriographic studies were performed in six cadaver specimens to identify the major arterial supply to the hallux. Discrepancies with now known anatomical models were discovered. In this study, the major arterial supply to the hallux appeared to originate from the lateral digital artery. In addition, two transverse digital arteries were noted to emit the nutrient arteries of the phalanges. Examination of other arteriographic studies sustained our results.

Angiography↗

Vascular anatomy of the fifth metatarsal.

The extraosseous and intraosseous vascular anatomy to the fifth metatarsal as visualized in a group of below-the-knee amputation specimens has been described. The extrinsic circulation to the area is provided by the dorsal metatarsal artery, the plantar metatarsal arteries, and the fibular plantar marginal artery. These three source arteries supply branches to the metatarsal and adjacent joints. The intraosseous vascularity consists of a periosteal plexus, a nutrient artery, and a system of metaphyseal and capital vessels.

Arteries↗

Photogrammetric analysis of the articular surface of the distal radius.

Three-dimensional measurements made using photogrammetry have recently gained popularity with the development of real-time detection facilities and up-to-date equipment. The modelling of human bones presents a particular challenge as the measurements required are difficult to obtain, especially from uneven surfaces. In this study, the articular surfaces of 12 radius bones were evaluated using photogrammetry to obtain three-dimensional coordinates of certain points. Morphometric characteristics of the digital topography of the articular surface were analysed using three-dimensional data from more than 200 points for each specimen. The coronal plane curve, from the tip of the styloid process to the centre of the distal radioulnar articular notch, was found to be similar to the fourth degree polynomial function. A mathematical expression representing the sagittal curve passing through scapholunate border could not be found. Close-range photogrammetry is a safe and precise technique that can provide reliable, reproducible and accurate data for evaluating complex morphological surfaces.

Anthropometry↗

Novel advances in drug delivery to brain cancer.

The therapy of brain tumors has been limited by a lack of effective methods of drug delivery to the brain. Systemic administration is often associated with toxic side effects and ultimately fails to achieve therapeutic concentrations within a tumor. An attractive strategy that has gained importance in brain tumor therapy has relied on local and controlled delivery of chemotherapeutic agents by biodegradable polymers. This technique allows direct exposure of tumor cells to a therapeutic agent for a prolonged period of time and has been shown to prolong the survival of patients with malignant brain tumors. The use of polymers for local drug delivery greatly expands the spectrum of drugs available for the treatment of malignant brain tumors. This review discusses the rationale for local drug delivery, describes the development of currently available polymer-based therapeutic agents, and highlights examples of promising non-polymer based drug delivery methods for use in the treatment of malignant brain tumors.

Animals↗

Peripheral signals conveying metabolic information to the brain: short-term and long-term regulation of food intake and energy homeostasis.

Numerous peripheral signals contribute to the regulation of food intake and energy homeostasis. Mechano- and chemoreceptors signaling the presence and energy density of food in the gastrointestinal (GI) tract contribute to satiety in the immediate postprandial period. Changes in circulating glucose concentrations appear to elicit meal initiation and termination by regulating activity of specific hypothalamic neurons that respond to glucose. Other nutrients (e.g., amino acids and fatty acids) and GI peptide hormones, most notably cholecystokinin, are also involved in short-term regulation of food intake. However, the energy density of food and short-term hormonal signals by themselves are insufficient to produce sustained changes in energy balance and body adiposity. Rather, these signals interact with long-term regulators (i.e., insulin, leptin, and possibly the orexigenic gastric peptide, ghrelin) to maintain energy homeostasis. Insulin and leptin are transported into the brain where they modulate expression of hypothalamic neuropeptides known to regulate feeding behavior and body weight. Circulating insulin and leptin concentrations are proportional to body fat content; however, their secretion and circulating levels are also influenced by recent energy intake and dietary macronutrient content. Insulin and leptin concentrations decrease during fasting and energy-restricted diets, independent of body fat changes, ensuring that feeding is triggered before body energy stores become depleted. Dietary fat and fructose do not stimulate insulin secretion and leptin production. Therefore, attenuated production of insulin and leptin could lead to increased energy intake and contribute to weight gain and obesity during long-term consumption of diets high in fat and/or fructose. Transcription of the leptin gene and leptin secretion are regulated by insulin-mediated increases of glucose utilization and appear to require aerobic metabolism of glucose beyond pyruvate. Other adipocyte-derived hormones and proteins that regulate adipocyte metabolism, including acylation stimulating protein, adiponectin, diacylglycerol acyltransferase, and perilipin, are likely to have significant roles in energy homeostasis.

Adipocytes↗

Accuracy of a system for creating 3D computer models of dental arches.

Three-dimensional imaging of dental tissues will have a major impact in dentistry if the images are accurate. The purpose of this study was to measure the accuracy and precision of a system for creating three-dimensional images of dental arches. Using vinyl polysiloxane impression materials and improved dental stone, we made 10 stone casts of a "dental" standard with known dimensions. The impressions and casts were scanned by means of a Comet 100 optical scanner. Custom software created three-dimensional images (computer models) from the scanned data. Accuracy was defined as the average of the absolute differences between the computer models and the standard. Precision was the standard deviation of accuracy over 10 repeated measures. Software processing improved the accuracy of the scanner data. Accuracy +/- precision for the casts and impressions was 0.024 +/- 0.002 mm and 0.013 +/- 0.003 mm, respectively. The system produced computer models with sufficient accuracy for clinical application.

Algorithms↗

Prediction of mechanical properties of the cancellous bone of the mandibular condyle.

The mechanical properties of cancellous bone depend on the bone structure. The present study examined the extent to which the apparent stiffness of the cancellous bone of the human mandibular condyle can be predicted from its structure. Two models were compared. The first, a structure model, used structural parameters such as bone volume fraction and anisotropy to estimate the apparent stiffness. The second was a finite element model (FEM) of the cancellous bone. The bone structure was characterized by micro-computed tomography. The calculated stiffnesses of 24 bone samples were compared with measured stiffnesses. Both models could predict 89% of the variation in the measured stiffnesses. From the stiffness approximated by FEM in combination with the measured stiffness, the stiffness of the bone tissue was estimated to be 11.1 +/- 3.2 GPa. It was concluded that both models could predict the stiffness of cancellous bone with adequate accuracy.

Aged↗

Model analysis of coil embolization of cerebral aneurysms: prediction of thrombus formation in aneurysms based on the coil embolization rate.

OBJECTIVES: Intra-aneurysmal coil embolization has been established as a common method for the intravascular treatment of cerebral aneurysms, but few studies have evaluated its long-term results. Because there is no sufficient objective landmark of complete embolization, determination of its application depends on a surgeon's experience. METHODS: A glass cerebral aneurysm model was produced, and the changes in intra-aneurysmal hemodynamics were examined. Nylon thread with a diameter of 0.33 mm, resembling the coils clinically used for embolization, was used to fill in the model. After perfusion of glycerin solution to represent human blood, the half life of a dye injected into the aneurysm was optically measured, and the relationship between the half life and the volume embolization rate (VER) of nylon thread in the aneurysm was examined. RESULTS: The maximal VER obtained by filling nylon thread in the aneurysm was 41.7+/- 2.9%. The half life of the dye increased with the VER and was significantly increased at VER>30%. DISCUSSION: The half life of the dye in the aneurysm reflected stagnation of intra-aneurysmal hemodynamics, suggesting that the prolongation of the half life enhances thrombus formation. The results of this study suggested that VER>30% is sufficient for effective coil embolization.

Carotid Artery Thrombosis↗

The Virtual Insect Brain protocol: creating and comparing standardized neuroanatomy.

BACKGROUND: In the fly Drosophila melanogaster, new genetic, physiological, molecular and behavioral techniques for the functional analysis of the brain are rapidly accumulating. These diverse investigations on the function of the insect brain use gene expression patterns that can be visualized and provide the means for manipulating groups of neurons as a common ground. To take advantage of these patterns one needs to know their typical anatomy. RESULTS: This paper describes the Virtual Insect Brain (VIB) protocol, a script suite for the quantitative assessment, comparison, and presentation of neuroanatomical data. It is based on the 3D-reconstruction and visualization software Amira, version 3.x (Mercury Inc.) 1. Besides its backbone, a standardization procedure which aligns individual 3D images (series of virtual sections obtained by confocal microscopy) to a common coordinate system and computes average intensities for each voxel (volume pixel) the VIB protocol provides an elaborate data management system for data administration. The VIB protocol facilitates direct comparison of gene expression patterns and describes their interindividual variability. It provides volumetry of brain regions and helps to characterize the phenotypes of brain structure mutants. Using the VIB protocol does not require any programming skills since all operations are carried out at an intuitively usable graphical user interface. Although the VIB protocol has been developed for the standardization of Drosophila neuroanatomy, the program structure can be used for the standardization of other 3D structures as well. CONCLUSION: Standardizing brains and gene expression patterns is a new approach to biological shape and its variability. The VIB protocol provides a first set of tools supporting this endeavor in Drosophila. The script suite is freely available at http://www.neurofly.de2.

Animals↗

Shooting darts: co-evolution and counter-adaptation in hermaphroditic snails.

BACKGROUND: Evolutionary conflicts of interest between the sexes often lead to co-evolutionary arms races consisting of repeated arisal of traits advantageous for one sex but harmful to the other sex, and counter-adaptations by the latter. In hermaphrodites, these antagonistic interactions are at least an equally important driving force. Here, we investigate the evolution of one of the most striking examples of sexual conflict in hermaphrodites, the so-called shooting of love-darts in land snails. Stabbing this calcareous dart through the partner's skin ultimately increases paternity. This trait is obviously beneficial for the shooter, but it manipulates sperm storage in the receiver. Hence, an arms race between the love-dart and the spermatophore receiving organs may be expected. RESULTS: We performed a detailed phylogenetic analysis of 28S ribosomal RNA gene sequences from dart-possessing land snail species. Both the Shimodaira-Hasegawa test and Bayesian posterior probabilities rejected a monophyletic origin of most reproductive structures, including the love-dart, indicating that most traits arose repeatedly. Based on the inferred phylogenetic trees, we calculated phylogenetically independent contrasts for the different reproductive traits. Subsequent principal component and correlation analyses demonstrated that these contrasts covary, meaning that correlated evolution of these traits occurred. CONCLUSION: Our study represents the first comprehensive comparative analysis of reproductive organ characteristics in simultaneous hermaphrodites. Moreover, it strongly suggests that co-evolutionary arms races can result from sexual conflict in these organisms and play a key role in the evolution of hermaphroditic mating systems.

Adaptation, Biological↗

Mating-induced reduction in accessory reproductive organ size in the stalk-eyed fly Cyrtodiopsis dalmanni.

BACKGROUND: Internal reproductive organ size is an important determinant of male reproductive success. While the response of testis length to variation in the intensity of sperm competition is well documented across many taxa, few studies address the importance of testis size in determining other components of male reproductive success (such as mating frequency) or the significance of size variation in accessory reproductive organs. Accessory gland length, but not testis length, is both phenotypically and genetically correlated with male mating frequency in the stalk-eyed fly Cyrtodiopsis dalmanni. Here we directly manipulate male mating status to investigate the effect of copulation on the size of both the testes and the accessory glands of C. dalmanni. RESULTS: Accessory gland length was positively correlated with male mating frequency. Copulation induced a significant decrease in accessory gland size. The size of the accessory glands then recovered slowly over the next 8-48 hours. Neither testis length nor testis area was altered by copulation. CONCLUSION: These results reveal that the time course of accessory gland recovery corresponds to field observations of mating behaviour and suggest that accessory gland size may limit male mating frequency in C. dalmanni.

Animals↗

Chance mechanisms affecting the burden of metastases.

BACKGROUND: The burden of cancer metastases within an individual is commonly used to clinically characterize a tumor's biological behavior. Assessments like these implicitly assume that spurious effects can be discounted. Here the influence of chance on the burden of metastasis is studied to determine whether or not this assumption is valid. METHODS: Monte Carlo simulations were performed to estimate tumor burdens sustained by individuals with cancer, based upon empirically derived and validated models for the number and size distributions of metastases. Factors related to the intrinsic metastatic potential of tumors and their host microenvironments were kept constant, to more clearly demonstrate the contribution from chance. RESULTS: Under otherwise identical conditions, both the simulated numbers and the sizes of metastases were highly variable. Comparable individuals could sustain anywhere from no metastases to scores of metastases, and the sizes of the metastases ranged from microscopic to macroscopic. Despite the marked variability in the number and sizes of the metastases, their respective growth times were rather more narrowly distributed. In such situations multiple occult metastases could develop into fully overt lesions within a comparatively short time period. CONCLUSION: Chance can have a major effect on the burden of metastases. Random variability can be so great as to make individual assessments of tumor biology unreliable, yet constrained enough to lead to the apparently simultaneous appearance of multiple overt metastases.

Animals↗

Fluid structure interaction of patient specific abdominal aortic aneurysms: a comparison with solid stress models.

BACKGROUND: Abdominal aortic aneurysm (AAA) is a dilatation of the aortic wall, which can rupture, if left untreated. Previous work has shown that, maximum diameter is not a reliable determinant of AAA rupture. However, it is currently the most widely accepted indicator. Wall stress may be a better indicator and promising patient specific results from structural models using static pressure, have been published. Since flow and pressure inside AAA are non-uniform, the dynamic interaction between the pulsatile flow and wall may influence the predicted wall stress. The purpose of the present study was to compare static and dynamic wall stress analysis of patient specific AAAs. METHOD: Patient-specific AAA models were created from CT scans of three patients. Two simulations were performed on each lumen model, fluid structure interaction (FSI) model and static structural (SS) model. The AAA wall was created by dilating the lumen with a uniform 1.5 mm thickness, and was modeled as a non-linear hyperelastic material. Commercial finite element code Adina 8.2 was used for all simulations. The results were compared between the FSI and SS simulations. RESULTS: Results are presented for the wall stress patterns, wall shear stress patterns, pressure, and velocity fields within the lumen. It is demonstrated that including fluid flow can change local wall stresses slightly. However, as far as the peak wall stress is concerned, this effect is negligible as the difference between SS and FSI models is less than 1%. CONCLUSION: The results suggest that fully coupled FSI simulation, which requires considerable computational power to run, adds little to rupture risk prediction. This justifies the use of SS models in previous studies.

Aged↗

Transient integral boundary layer method to calculate the translesional pressure drop and the fractional flow reserve in myocardial bridges.

BACKGROUND: The pressure drop-flow relations in myocardial bridges and the assessment of vascular heart disease via fractional flow reserve (FFR) have motivated many researchers the last decades. The aim of this study is to simulate several clinical conditions present in myocardial bridges to determine the flow reserve and consequently the clinical relevance of the disease. From a fluid mechanical point of view the pathophysiological situation in myocardial bridges involves fluid flow in a time dependent flow geometry, caused by contracting cardiac muscles overlying an intramural segment of the coronary artery. These flows mostly involve flow separation and secondary motions, which are difficult to calculate and analyse. METHODS: Because a three dimensional simulation of the haemodynamic conditions in myocardial bridges in a network of coronary arteries is time-consuming, we present a boundary layer model for the calculation of the pressure drop and flow separation. The approach is based on the assumption that the flow can be sufficiently well described by the interaction of an inviscid core and a viscous boundary layer. Under the assumption that the idealised flow through a constriction is given by near-equilibrium velocity profiles of the Falkner-Skan-Cooke (FSC) family, the evolution of the boundary layer is obtained by the simultaneous solution of the Falkner-Skan equation and the transient von-Kármán integral momentum equation. RESULTS: The model was used to investigate the relative importance of several physical parameters present in myocardial bridges. Results have been obtained for steady and unsteady flow through vessels with 0 - 85% diameter stenosis. We compare two clinical relevant cases of a myocardial bridge in the middle segment of the left anterior descending coronary artery (LAD). The pressure derived FFR of fixed and dynamic lesions has shown that the flow is less affected in the dynamic case, because the distal pressure partially recovers during re-opening of the vessel in diastole. We have further calculated the wall shear stress (WSS) distributions in addition to the location and length of the flow reversal zones in dependence on the severity of the disease. CONCLUSION: The described boundary layer method can be used to simulate frictional forces and wall shear stresses in the entrance region of vessels. Earlier models are supplemented by the viscous effects in a quasi three-dimensional vessel geometry with a prescribed wall motion. The results indicate that the translesional pressure drop and the mean FFR compares favourably to clinical findings in the literature. We have further shown that the mean FFR under the assumption of Hagen-Poiseuille flow is overestimated in developing flow conditions.

Animals↗

3D geometric reconstruction of thoracic aortic aneurysms.

BACKGROUND: The thoracic aortic aneurysm (TAA) is a pathology that involves an expansion of the aortic diameter in the thoracic aorta, leading to risk of rupture. Recent studies have suggested that internal wall stress, which is affected by TAA geometry and the presence or absence of thrombus, is a more reliable predictor of rupture than the maximum diameter, the current clinical criterion. Accurate reconstruction of TAA geometry is a crucial step in patient-specific stress calculations. METHODS: In this work, a novel methodology was developed, which combines data from several sets of magnetic resonance (MR) images with different levels of detail and different resolutions. Two sets of images were employed to create the final model, which has the highest level of detail for each component of the aneurysm (lumen, thrombus, and wall). A reference model was built by using a single set of images for comparison. This approach was applied to two patient-specific TAAs in the descending thoracic aorta. RESULTS: The results of finite element simulations showed differences in stress pattern between the coarse and fine models: higher stress values were found with the coarse model and the differences in predicted maximum wall stress were 30% for patient A and 11% for patient B. CONCLUSION: This paper presents a new approach to the reconstruction of an aneurysm model based on the use of several sets of MR images. This enables more accurate representation of not only the lumen but also the wall surface of a TAA taking account of intraluminal thrombus.

Aortic Aneurysm, Thoracic↗

A convenient scheme for coupling a finite element curvilinear mesh to a finite element voxel mesh: application to the heart.

BACKGROUND: In some cases, it may be necessary to combine distinct finite element meshes into a single system. The present work describes a scheme for coupling a finite element mesh, which may have curvilinear elements, to a voxel based finite element mesh. METHODS: The method is described with reference to a sample problem that involves combining a heart, which is defined by a curvilinear mesh, with a voxel based torso mesh. The method involves the creation of a temporary (scaffolding) mesh that couples the outer surface of the heart mesh to a voxel based torso mesh. The inner surface of the scaffolding mesh is the outer heart surface, and the outer surface of the scaffolding mesh is defined by the nodes in the torso mesh that are nearest (but outside of) the heart. The finite element stiffness matrix for the scaffolding mesh is then computed. This stiffness matrix includes extraneous nodes that are then removed, leaving a coupling matrix that couples the original outer heart surface nodes to adjacent nodes in the torso voxel mesh. Finally, a complete system matrix is assembled from the pre-existing heart stiffness matrix, the heart/torso coupling matrix, and the torso stiffness matrix. RESULTS: Realistic body surface electrocardiograms were generated. In a test involving a dipole embedded in a spherical shell, relative error of the scheme rapidly converged to slightly over 4%, although convergence thereafter was relatively slow. CONCLUSION: The described method produces reasonably accurate results and may be best suited for problems where computational speed and convenience have a higher priority than very high levels of accuracy.

Algorithms↗