Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Densitometry”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85Linked to original sources

Improved quantitation of minimal residual disease in multiple myeloma using real-time polymerase chain reaction and plasmid-DNA complementarity determining region III standards.

The complementarity determining region III of the rearranged immunoglobulin heavy chain gene has been the target for tumor-specific PCR assays for the detection and follow-up of B-cell malignancies. Previously, these assays have relied on gel-based end point data collection methods (i.e., band densitometry) and, thus, have provided at best a semiquantitative assessment of tumor levels. We show the development of a novel, real-time TaqMan PCR assay to quantitate residual multiple myeloma cells in clinical samples after high-dose chemotherapy and autologous stem cell transplantation. We provide evidence that real-time PCR is reproducible, sensitive, and quantitative. In a 40-replicate PCR experiment targeting the beta-actin gene, the coefficient of variation for threshold cycle data was 1.6%, whereas it increased to 13.6% and 31%, respectively, for end point fluorescence and gel densitometry. Moreover, in an experiment directly comparing standard curves obtained from band densitometry and threshold cycle data, the standard curve constructed from threshold cycle data had a multiple R2 value of 1.00 and demonstrated a dynamic range >4 logs, compared with the 2-log linear range of gel densitometry. Finally, we show that when a complementarity determining region III-specific PCR primer is used in conjunction with a consensus primer for the immunoglobulin heavy chain joining gene, plasmid DNA can be used as a readily available and effective substitute for clonal plasma-cell genomic DNA when preparing standards. By applying real-time PCR to the analysis of clinical samples, we are able to quantitate levels of tumor involvement with unparalleled reproducibility and statistical confidence. Real-time PCR technology may well provide the accuracy and reliability necessary for minimal residual disease detection to have real prognostic significance.

Base Sequence↗

Purification of commercial coomassie brilliant blue R-250 and characterization of the chromogenic fractions.

Coomassie brilliant blue R-250 (CBB) is a popular and widely used dye for detection of proteins by gel electrophoresis. However, commercially available CBBs are complex mixtures of numerous chromogenic compounds that vary from lot to lot, thereby giving an undesirable level of variation in reproducibility, precision, and specificity in staining gels. We have developed a silica gel column chromatographic method for purification of commercial CBBs in high yield and have standardized each lot to perform equivalently in staining proteins as determined by sodium dodecyl sulfate-polyacrylamide gel electrophoresis and quantitative scanning densitometry. This is a major improvement in protein purity determinations by quantitative scanning densitometry. A thinlayer chromatographic method for quality control testing of the purified CBB lots was also developed. Plasma desorption mass spectrometry was used to identify components of silica gel column fractions. Scanning densitometry was the technology used to establish performance equivalency between different CBB preparations. The less polar chromogenic compounds are nonblue and/or fluorescent in color, contain mono- or unsulfonated structures, and lack significant protein binding capacity. The more polar chromogenic compounds are green and blue-green in color, contain tri- and tetrasulfonated moieties, compared to the disulfonated structure of CBB, and bind to protein at least 40 times more effectively than pure CBB. The concentrations of these highly polar chromogens differ from lot to lot and act as "inhibitors" in protein staining, thereby causing variability in protein staining.

Chromatography, Thin Layer↗

The tale of the T-score: review and perspective.

The T-score is well known to anyone working in the field of bone densitometry. It is the primary output from a bone densitometry system and is most often used for diagnosis of osteoporosis and for making treatment decisions. Despite widespread acceptance of the T-score, most clinicians are unfamiliar with the historical evolution of the T-score as a clinical measure. Furthermore, evidence is mounting that the T-score is not the optimal diagnostic parameter for clinical decision making. Many additional risk factors have been reported which can be combined with bone density results to assess absolute fracture risk. This editorial provides an historical review of the T-score, followed by summary of the status of the T-score, and concludes with suggestions for the future use of the T-score in bone densitometry.

Bone Density↗

Reliability of an electrophoretic and image processing analysis of human skeletal muscle taken from m. vastus lateralis.

The relative content of myosin heavy chain (MHC) isoforms IIb, IIa and I in human skeletal muscle taken from the m. vastus lateralis of 30 healthy male subjects was analysed using mini-gel electrophoresis. Repeated electrophoretic gels utilizing the same methods were produced for all subjects and the determination of MHC protein bands was performed using a digital scanner and National Institutes of Health (NIH) Image software and laser densitometry. A comparison between the NIH Image processing technique and laser densitometry revealed differences of 6.47%, 6.35% and 6.84% between these measurement techniques for MHC-IIb, -IIa and -I isoforms, respectively. The percentage technical error of measurement (TEM%) between electrophoretic gels was shown to be 19.1%, 17.8% and 14.2%, with regard to percentage of occurrence of MHC-IIb, -IIa and -I isoforms respectively. The variation in electrophoretic gel analyses was shown to be 5.7%, 7.3% and 5.5%, with regard to the percentage of MHC-IIb, -IIa and -I isoforms respectively. Intra-class correlations comparing NIH Image and laser densitometry produced r values in the range 0.38-0.63. Comparisons between and within gel analyses produced r values in the range 0.59-0.94 and 0.93-0.98, respectively. Analyses of variance revealed no significant differences (P < 0.05) between analysis techniques, between gels or within gels for the measurement of MHC-IIb, -IIa and -I isoforms. The inter-gel error between fibre subgroups was moderate for the two type-II MHC populations and less for type-I MHC; the intra-individual error in the measuring technique used for classifying the MHC-IIb, -IIa and -I protein bands was small. The results obtained in this investigation showed consistent trends which may reflect a false classification of the type-II MHC populations for the inter-gel and intra-individual analyses. The NIH Image software and digitizing process was shown to be a valid and reliable method for distinguishing between MHC protein bands of human skeletal tissue as separated by mini-gel electrophoretic techniques.

Adult↗

Quantitation of IgE and carcinoembryonic antigen (CEA) by optical beam deflection (OBD) measurement of dot-immunobinding assay patterns visualized by an ELISA technique.

Dot-immunobinding assays of IgE and CEA were performed by a conventional dot-ELISA technique with diaminobenzidine staining, and the quantitative results were compared by densitometry and a new, spectroscopic, optical beam deflection (OBD) method using the same membrane. It was possible with the OBD method to detect quantities of these substances at least ten times smaller than with densitometry. Better intra-assay reproducibility for IgE and CEA measurements was obtained by the OBD method. The measurable ranges of the OBD method was broader than that of densitometry, because dark bands caused OBD in proportion to their color densities. When the dot-immunobinding assay with OBD measurement for CEA was also compared with a microtube ELISA using biotin-avidin conjugates, the sensitivities and reproducibilities of the two methods were found to be similar, with a correlation coefficient of 0.991.

Carcinoembryonic Antigen↗

Use of densitometric analysis for interpreting HSV serologies based on Western blot.

Western blot assays have been described for detecting antibodies to herpes simplex virus (HSV). A predominance of antibody binding to either the HSV-1 or the HSV-2-containing blot has been reported to indicate infection with HSV-1 or HSV-2, respectively. By densitometry, differential binding of total antibody on HSV-1 versus HSV-2 strips can be expressed as a ratio. To determine the clinical correlation of these ratios, sera from 81 patients with culture-proven oral or genital herpes were tested by Western blot (WB) and densitometry. Binding ratios accurately identified patients with primary HSV-2 infections. However, ratios on sera with HSV-1 antibody or dual antibody status showed considerable overlap. Densitometry was shown to amplify and clarify the band corresponding to the HSV-2 specific glycoprotein gG-2 and was useful, in this respect, for detecting HSV-2 antibody in the presence of HSV-1 antibody. Sera from 52 patients with asymptomatic HSV-1, HSV-2 or dual infection were also tested by WB. Typing results were confirmed by cross-adsorption of sera ("adsorption blot assay"). Ratios of HSV-2 to HSV-1 binding were higher in asymptomatic versus symptomatic patients with dual antibody (P less than 0.01). Ratios for those with HSV-1 or HSV-2 antibody types were not affected by disease expression.

Antibodies, Viral↗

Improvement of chemical analysis of antibiotics. VII. Comparison of analytical methods for determination of impurities in tetracycline pharmaceutical preparations.

In order to examine the suitability of our four established methods for the analysis of tetracyclines (high-performance liquid chromatography, reversed-phase thin-layer chromatographic densitometry, reversed-phase thin-layer chromatographic spray reagents and silica gel high-performance thin-layer chromatographic densitometry) for the determination of impurities in tetracycline pharmaceutical preparations, sixteen samples available on the Japanese market were analysed. Because these methods did not always give satisfactory results, their analytical conditions were modified. The comparative studies indicated these methods were accurate and reliable. Therefore, we recommend a combination of these methods for the analysis of impurities, in which the spray reagents are used first as a screening method, and then if the results exceed the limits, a precise determination is carried out using either high-performance liquid chromatography or reversed-phase thin-layer chromatographic densitometry.

Anti-Bacterial Agents↗

Update on bone density measurement.

Bone densitometry is a clinically accepted technique for assessing fracture risk and evaluating skeletal change. The proper clinical use of densitometry requires an understanding of the available techniques, their appropriate application, and the potential sources of measurement error. Recent clinical guidelines recommend that all women over the age of 65 years and all postmenopausal women with risk factors should have their bone density assessed. With the advent of smaller portable devices, bone density measurements are now widely available. In particular, ultrasound techniques, which do not use radiation, have particular promise for widespread screening applications. Peripheral densitometry alone cannot adequately address all clinical questions, particularly the question of monitoring subtle changes in bone density. For this purpose, central densitometers are still preferred. For any bone density measurement to be clinically useful, it must be performed with careful attention to detail, particularly with regard to instrument calibration, patient positioning, measurement analysis, and interpretation.

Absorptiometry, Photon↗

Quantitative assessment of gray-level perception: observers' accuracy is dependent on density differences.

Sonographic image density represents tissue echogenicity, or the acoustic nature of scanned tissue. It has the potential to distinguish normal from abnormal tissue. Humans are poor assessors of tissue echogenicity, yet their abilities have not been quantitatively compared to more objective methods. We compared the accuracy of image density differentiation by the human eye and by densitometry in the fetal liver model. A group of 60 observers was asked to compare the echogenicity of three pairs of images of a fetal liver. Twenty-three repeated the comparison several weeks later. Image density was measured by electro-optical densitometry. The two-tailed signed rank test was used to compare the observer's perceptions with the density values and the repeated observations with the original responses. The density of each fetal liver image in pair A was the same. Image B1 had a 12.3% lower density than image B2, and image C1 had a 6.3% greater density than image C2. Observers were accurate more often when comparing images with large density differences (pair B) than they were when comparing images with the same density (pair A) or with small density differences (pair C). Accuracy was not related to being medically qualified or from an obstetric or gynecological department. Intraobserver variation was not significant. We conclude that the human eye is extremely inaccurate at discerning differences in echogenicity when images have small or no differences in optical density. Densitometry is, therefore, indispensable for accurate image density assessment.

Densitometry↗

Measuring the body composition of elderly subjects: a comparison of methods.

There is a paucity of data on differences between methods for the assessment of body composition in elderly subjects. Studies on younger adults suggest that such differences are of some practical significance at the individual level. In the present study the following methods of estimating percentage body fatness (BF%) were compared in healthy elderly men and women (mean age 70 (SD 6) years: densitometry; skinfold thickness; total body water; bioelectrical impedance (BIA) using an age-specific predictive equation and the manufacturers' equation; body mass index (BMI). Though BF% estimates from the various methods tended to be highly correlated with those from densitometry and with each other, differences between methods at the individual level were marked. In particular, the age-specific equations based on BMI and BIA systematically overestimated BF% relative to the other methods. Biases between BF% estimates derived from densitometry, skinfolds, BIA (manufacturers' equation) and total body water were less marked, indicating little evidence of systematic differences between these methods in elderly subjects. Individual differences between methods were slightly greater than those reported in some studies of younger adults, but this may be of little practical significance, and may be considered inevitable in view of variability between and within subjects in the extent to which the underlying assumptions of these two-component methods are met in elderly subjects.

Aged↗

The optical density of erythrolabe determined by a new method.

1. A new method is described for the determination of optical density by retinal densitometry based on an analysis of stray light.2. The basic assumption used is that the stray light present in retinal densitometry is independent of wave-length. The justification for this assumption is considered.3. The stray light and hence the optical density was determined by a method of successive approximations using a Linc 8 computer.4. The optical density of erythrolabe for the direction of maximum Stiles-Crawford efficiency was determined for five subjects, two deuteranopes, two deuteranomalous and one red-rich normal subject. The mean values for three of the subjects were close to the grand mean value of 0.42, but the other two subjects had considerably higher and lower values respectively.5. The results are in satisfactory agreement with optical density values determined by the self-screening method using retinal densitometry, and also with determinations using microspectrophotometry and psychophysics.6. The relevance of dielectric wave-guide modes in the outer segments is considered.

Color Vision Defects↗

Study of nuclear cataract progression using the National Eye Institute Scheimpflug system.

AIMS: A study was conducted to determine the capability of the recently developed National Eye Institute (NEI) Scheimpflug cataract imaging system in detecting changes in the nuclear region of the lens over a 1 year period. METHODS: Twenty five eyes with pure nuclear cataracts with mean nuclear densities < or = 0.30 optical density units (ODU) as well as 30 normal control eyes were each examined at baseline and 12 months later. Computerised densitometry using the NEI Scheimpflug cataract imaging system was performed. Clinical grading of the lenses was also done using the Lens Opacities Classification System II (LOCS II). For densitometry, a change of plus or minus 0.023 ODU (the 99% range) in mean density in the nuclear area was considered a progression or regression at 1 year. RESULTS: Using the Scheimpflug densitometry, 14 of the 25 cataractous eyes showed significant progression at 1 year. In the normal control group, only three of the 30 eyes showed significant progression. In contrast, using the LOCS II clinical grading, only two of the 25 cataractous eyes showed a one step increase, two of the 30 controls progressed at 1 year, and none regressed. There was no significant difference in visual acuity. CONCLUSION: This study suggests the value of the NEI Scheimpflug cataract imaging system in detecting nuclear change within 1 year. However, clinically significant changes may require longer follow up periods. These data will be useful in planning future longitudinal studies of nuclear cataracts, such as for clinical trials of anticataract drugs.

Adult↗

A Comparison between Composition and Density of the Fat-Free Mass of Young Adult Singaporean Chinese and Dutch Caucasians.

BACKGROUND: The body composition was measured in 30 female Singapore Chinese and 34 female Dutch Caucasians aged (mean +/- SD) 22.7 +/- 3.6 years and in 39 male Singapore Chinese and 39 male Dutch Caucasians aged 23.3 +/- 3.2 years. METHODS: The body fat percentage (BF%) was measured using densitometry and deuterium oxide dilution as well as a chemical four-compartment model, including fat mass, water, mineral, and protein. The chemical composition of the fat-free mass (FFM) and its density were calculated. RESULTS: Mean body mass index (kg/m(2)) and BF% based on the four-compartment model in the four subgroups were 20.3 +/- 1.5 and 29.7 +/- 5.3 for the Singapore Chinese females, 22.1 +/- 1.2 and 28.9 +/- 5.2 for the Dutch females, 21.5 +/- 2.5 and 19.4 +/- 6.1 for the Singapore males, and 22.2 +/- 1.8 and 15.8 +/- 4.9 for the Dutch males. The contributions to the FFM of water, protein, and mineral were, respectively, 72.8 +/- 1.5, 19.2 +/- 1.8, and 7.9 +/- 0.8% for the Singaporean females and 74.2 +/- 1.4, 18.3 +/- 1.5, and 7.6 +/- 0.5% for the Dutch females. In males these figures were 73.2 +/- 1.7, 19.6 +/- 1.7, and 7.3 +/- 0.5% for the Singaporeans and 72.9 +/- 1.4, 20.5 +/- 1.4, and 6.6 +/- 0.5% for the Dutch. In females, these figures were for all components significantly different between the ethnic groups; in males the differences were significant for protein and mineral only. The calculated densities (kg/l) of the FFM were 1.1074 +/- 0.0057, 1.1012 +/- 0.0051, 1.1027 +/- 0.0065, and 1.1004 +/- 0.0055 for the Chinese females, Caucasian females, Chinese males, and Caucasian males, respectively. CONCLUSIONS: Although it cannot be excluded that the differences in density and composition of the FFM are due to methodological differences between the study sites, the findings may have consequences for the validity of single (reference) methods due to violation of normally used assumptions. The findings explain the observed underestimation of BF% from density using Siri's formula in the Chinese subjects, especially in females. The use of deuterium oxide as a single method to determine the BF% resulted in a smaller bias than densitometry (overall 1.6 +/- 2.0% for densitometry, 0.3 +/- 1.7% for deuterium dilution), suggesting that the deuterium oxide method may be more suitable as a single method in comparative body composition studies.

Adipose Tissue↗

Comparative effect of soy protein, soy isoflavones, and 17beta-estradiol on bone metabolism in adult ovariectomized rats.

UNLABELLED: This study provided a comprehensive investigation on the effect of soy protein and soy isoflavones on both calcium and bone metabolism in virgin adult rats. The measurements included bone histology, calcium kinetic modeling, calcium balance, bone densitometry, and whole body densitometry. Results confirmed the bone-preserving effect of estrogen but did not support a bone-sparing role of soy isoflavones. INTRODUCTION: Several animal and short-term human studies have indicated that soy protein isolate enriched with isoflavones may be used as an alternative therapy to estrogen replacement therapy. However, none of the previous studies have investigated this estrogenic effect on both calcium and bone metabolism in animals or humans, which is essential in ascertaining the mode of action of isoflavones. MATERIALS AND METHODS: This study was designed to determine the effects of soy protein versus isoflavones on calcium and bone metabolism in an ovariectomized rat model. Unmated 6-month-old ovariectomized and sham-operated female Sprague-Dawley rats were randomly assigned to nine groups (16 rats/group) and pair-fed soy- or casein-based diets with or without isoflavones for 8 weeks. A reference group was administered estrogen through subcutaneous implants (20-35 pg/liter plasma). Bone densitometry, histomorphometry, and mechanical testing were used to study bone metabolism and quality. Calcium metabolism was studied using calcium tracer balance and kinetics. RESULTS: After ovariectomy, estrogen prevented bone loss in trabecular bone and suppressed formation on both trabecular and cortical bone surfaces. Isoflavones given as enriched soy protein isolate or supplements did not prevent trabecular bone loss. Combining isoflavones with estrogen had no additional benefits over estrogen alone. There were no differences in response to isoflavones caused by protein source. None of the treatments significantly affected either total Ca balance or (45)Ca absorption. However, soy protein showed significant effects on reducing urinary loss of Ca in animals, irrespective of isoflavone level, perhaps because of the lower amount of sulfur-containing amino acids in soy protein. CONCLUSION: Estrogen, but not isoflavones at the levels tested, suppressed bone remodeling in both trabecular and cortical bone after ovariectomy.

Absorption↗

Does the combination of two BMD measurements improve fracture discrimination?

UNLABELLED: Combining information from different types of BMD measurement should improve the evaluation of patients' risk of fracture. This study used a bivariate gaussian model to examine the effect of combining two different BMD measurements. The results show that, in practice, there is little benefit unless the measurements are completely unrelated. INTRODUCTION: Intuitively, the combination of information from two or more different types of bone densitometry investigation should improve our ability to identify patients at high risk of fracture. However, the best way to combine measurements and the resulting gain in fracture discrimination are not known. MATERIALS AND METHODS: In this study, we used a bivariate gaussian model to investigate the effect of combining two different types of bone densitometry measurements. The measurements had individual relative risk values RR1 and RR2 and a correlation coefficient r between their Z-scores. Different approaches to the combination of the two measurements were compared by calculating the area under the curve (AUC) for the receiver operating characteristic (ROC) curve, which was obtained by plotting the percentage of fracture patients against the percentage of the whole population with a Z-score below some chosen threshold. ROC curves were calculated for three cases: (1) one type of measurement only; (2) two different types of measurements combined using their mean Z-score weighted according to the theoretical optimum weighting factors predicted by the bivariate gaussian model; and (3) two different types of measurements combined using the conventional World Health Organization (WHO) approach, where one or other measurement is below a set threshold. The theoretical model was tested using measurements of speed of sound (SOS) in the radius, phalanx, and metatarsal in patients with vertebral and Colles' fractures. RESULTS: Results were calculated for RR values of 1.5, 2.0, and 2.5 and r = 0, 0.5, and 0.7. Although a significant improvement in fracture discrimination was obtained when r = 0 and RR1 = RR2, the improvements obtained when r > or = 0.5 or RR1 double dagger RR2 were relatively modest. Slightly better fracture discrimination was obtained using the weighted mean Z-score approach compared with the WHO approach, although the differences were small. The results of the in vivo study in Colles' and vertebral fracture patients showed close agreement with the predictions of the bivariate gaussian model. CONCLUSION: In practice, from a theoretical point of view, there is unlikely to be any benefit from combining information from different types of bone densitometry measurements unless they are completely unrelated.

Bone Density↗

Declining bone mass in men with chronic pulmonary disease: contribution of glucocorticoid treatment, body mass index, and gonadal function.

BACKGROUND: Men with chronic lung disease (CLD) are at risk for osteoporosis, but the relative contributions of their chronic pulmonary disease, glucocorticoid therapy, and other factors toward loss of bone has not been established. Understanding the relative importance of these factors would assist in selecting patients for bone densitometry screening and in policy decisions regarding Medicare reimbursement. OBJECTIVE: To identify patients with CLD who are most likely to benefit from bone densitometry screening based on clinical and biochemical measures. DESIGN: Cross-sectional medical survey. PATIENTS: Patients with CLD who were treated with either oral, inhaled, or no glucocorticoid therapy. A control group without lung disease was recruited from the same clinic population. MEASUREMENTS: Dual-energy X-ray absorptiometry was obtained for each group, and the association between bone mass and clinical variables, glucocorticoid use, gonadal hormones, and biochemical markers of bone metabolism was determined. RESULTS: Osteoporosis (a T score < -2.5 at the hip or spine) was five times as likely in patients with CLD as in control subjects. Although the prevalence of osteoporosis was higher (ninefold) after chronic glucocorticoid therapy, patients with CLD who had never been treated with glucocorticoids had a substantial (fourfold) risk of osteoporosis. Chronic inhaled glucocorticoid therapy offered no protection from bone loss compared to treatment with oral glucocorticoids. Of the clinical and biochemical measures that were obtained, bone mass was weakly correlated with body mass index (BMI), serum estradiol-17beta, and N-telopeptide, but not with testosterone, alkaline phosphatase, bone-specific alkaline phosphatase, or osteocalcin. CONCLUSION: Patients with CLD should be considered for bone densitometry screening regardless of glucocorticoid use. Those patients with a low BMI and/or decreased serum estradiol-17beta comprise a subgroup with increased risk for osteoporosis.

Adult↗

What is the role of serial bone mineral density measurements in patient management?

The ability of dual X-ray absorptiometry (DXA) to monitor bone mineral density (BMD) has been well documented in epidemiologic and pharmaceutical trials. However, its application to monitoring of patients in clinical practice has been subject to recent controversies. Despite these controversies, most clinical centers rely on DXA for monitoring of patients, and therefore guidance is needed. In this article, we report the positions developed by an expert panel of the International Society for Clinical Densitometry on the use of densitometry for the serial measurement of bone mass for monitoring change in BMD. The panel found DXA to be a precise method of measuring change in BMD if used with an appropriate level of least significant change (LSC), at anatomic sites with good precision and response to therapy, and at 1- to 2-yr time intervals. Monitoring is acceptable for determining when therapy is indicated, and if an agent is not therapeutically effective (i.e., when bone loss occurs despite treatment). Each densitometry center should perform an in vivo precision study on individuals similar to the patient population at the center and determine LSC at a 95% confidence level. If such a precision study cannot be performed, benchmark precision might be used, although there was no agreement on what values should be used. The PA spine is the preferred anatomic site for monitoring. The total hip can be used when the spine study is technically invalid. We conclude with recommendations for further research.

Absorptiometry, Photon↗

Comparison of methodologies for thalassemia screening by Hb A2 quantitation.

An efficient, reliable, inexpensive screening test for beta-thalassemia triat is required before the National Cooley's Anemia Control Act can be carried out. Densitometry of hemoglobin samples separated by cellulose acetate has become a routine procedure to quantitate Hb A2 and thereby indicate beta-thalassemia trait carriers. To determine the utility of densitometry in quantitation of Hb A2, we evaluated three densitometers marketed in the United States. Individuals with genetically proved beta-thalassemia trait and normal Hb AA controls were studied. Two analytic procedures (elution and column chromatography) for Hb A2 quantitation were used as reference methods. Densitometry was shown to be unsatisfactory for detecting beta-thalassemia-trait carriers. We recommend that a unified approach to the detection of anemia, which would include thalassemia trait, be developed in the United States rather than free-standing thalassemia screening centers and clinics.

Chromatography, Gel↗