Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Colloids”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85Linked to original sources

Lowered serum cholesterol following the ingestion of a hydrophilic colloid.

An attempt was made to test the possible clinical application of the cholesterol-lowering effect of hydrophilic colloids. 10 patients with high mean serum cholesterol levels during a 3-week control period and 9 with normal mean levels were each fed 11.5 g daily of undiluted hydrophilic colloid for 5 weeks. Serum cholesterol decreased significantly in 8 of the 10 (80%) patients with control-period hypercholesteremia and 6 of the 9 (66 2/3%) with control-period normal levels. These findings tend to confirm the observation that a simple and commonly used type of medication for chronic constipation, particularly in the elderly, may be a useful adjunct in the management of hypercholesterolemia.

Administration, Oral↗

Visualization of silver-enhanced reaction products from protein-and immuno-colloidal gold probes by laser scanning confocal microscopy in reflection mode.

We have employed a laser scanning confocal microscope in reflection mode to directly and indirectly visualize sites of deposition of silver-enhanced reaction products from colloidal gold probes. A direct approach was used for the localization of alpha-fetoprotein receptors in human myoblasts by incubating primary cultures with an alpha-fetoprotein-gold conjugate. For an indirect approach, cultured CEM cells, derived from a human T-lymphoma cell line, were incubated with a mouse monoclonal antibody to mature T-cells, followed by a gold-labelled antibody to mouse immunoglobulins. Multiple optical sections of each sample were collected by reflection laser scanning confocal microscopy and combined into three-dimensional renderings. A (non-confocal) transmission image was generated of each field for comparative purposes. The increasing use of reflection laser scanning confocal microscopy combined with colloidal gold conjugates as biological markers will probably be of considerable advantage in cytochemical analysis.

Antigens, CD↗

Measurement of colloidal iron binding at low pH in cartilage using the proton microprobe.

Quantitative micro-PIXE analysis was performed on mouse embryo epiphyseal cartilage and on the rib cartilage of mature animals after incubation of sections with colloidal iron at pH 1.8. The iron content as well as that of sulphur and phosphorus and Fe/S, Fe/P ratios were determined. It was found that colloidal iron content was higher in the cartilage than in other tissues. The cartilage also displayed the highest content of sulphur. The Fe/S ratio was however not constant, being highest in the degeneration zone close to the mineralization front, where the binding of iron was strongest while the amount of sulphur decreased. This indicates that factors other than number of sulphate groups influence the binding of positively charged molecules to glycosaminoglycans. This is confirmed by differences in the results obtained for embryonic and mature rib cartilage.

Aging↗

Estimation of the hepatic blood flow in the dog with the Xe133 and hydrogen wash-out Au190 -colloid uptake techniques and with the electromagnetic flowmeter.

In dogs anaesthetized with pentobarbital hepatic blood flow measured with electromagnetic flowmeters placed on the hepatic artery and the portal vein was 142 +/- 10.2 ml.min(-1).100 g(-1). The flow estimated with the hydrogen clearance technique was 64 +/- 4.4 per cent, with the Xe133 wash-out technique 78 +/- 7.4 per cent and by the uptake of colloidal radiogold 96.5 +/- 5.0 per cent of the direct measurement. In the flow range between 50 and 344 ml.min-1. 100 g-1 the respective correlation coefficient between HBF measured with the hydrogen clearance technique and with the flowmeter was 0.733, between Xe133-HBF and flowmeter HBF 0.785 and between Au198-colloid HBF and the directly measured HBF was 0.815.

Animals↗

Electron-probe x-ray analysis of granules and particles found in aurosomes produced by colloidal gold.

Aurosomes produced in the rabbit synovial membrane after intraarticular injection of colloidal gold were found to contain large spherical electron-dense granules and fine electron-dense particles. Electron-probe x-ray analysis demonstrated the presence of gold in the granules and iron in the particles. Sulphur and phosphorus were not detected in these aurosomes produced by colloidal gold. This is in contrast to the aurosomes produced by the soluble gold salt sodium aurothiomalate where besides gold, sulphur and phosphorus are easily detected.

Animals↗

Sentinel lymph node biopsy using tin colloid RI and blue dye method.

Axillary dissection has been considered essential for breast cancer staging because nodal metastasis is the most powerful predictive factor for recurrence. On the other hand, morbidity, such as lymphedema and shoulder dysfunction, may occur. Sentinel node biopsy is a good way to avoid unnecessary axillary dissection. We used tin colloid as a carrier of Tc99m tracer together with the blue dye method. The detection rate of the sentinel node was 27 cases out of 29 (90%) for the blue dye method, 10 cases out of 19 (53%) for the RI method, and 27 out of 33 (82%) for the combined method. The detection rate of the RI method was improved after adding the subcutaneous injection over the tumor from 45% before adding the subcutaneous injection to 82% after adding it. The false negative rate was 11% for the blue dye method, 0% for the RI method, and 10% for the combined method. This yields a sensitivity of 89% for the blue dye method, 100% for the RI method, and 90% for the combined method. Specificity was 100% for all three methods. Accuracy was 96% for the blue dye method, 100% for the RI method, and 96% for the combined method. There were two false negative cases. The average number of sentinel lymph nodes was 2.12 for the dye method, 1.66 for the RI method, and 1.95 for the combined method. There were three of 49 cases with identified parasternal lymph nodes by RI imaging. Lymphatic mapping using tin colloid may be useful for detecting sentinel nodes.

Adult↗

Colloid droplet accumulation precedes the enhancement of 6-keto-PGF 1 alpha release from the thyrotropin-stimulated thyroid gland.

Influence of thyrotropin (TSH) on colloid droplet formation in thyroid follicular cells and on release of a stable prostacyclin metabolite, 6-keto-prostaglandin 1 alpha (6-keto-PGF 1 alpha) from the thyroid has been studied in rats. Maximal accumulation of colloid droplets preceded the enhancement of the 6-keto-PGF 1 alpha release. Such a time sequence speaks against the possibility of prostacyclin involvement in the thyroid secretory response to TSH.

6-Ketoprostaglandin F1 alpha↗

Colloidal drug carriers: achievements and perspectives.

Colloidal drug carriers such as liposomes and nanoparticles are able to modify the distribution of an associated substance. They can therefore be used to improve the therapeutic index of drugs by increasing their efficacy and/or reducing their toxicity. If these delivery systems are carefully designed with respect to the target and route of administration, they may provide one solution to some of the delivery problems posed by new classes of active molecules such as peptides, proteins, genes, and oligonucleotides. They may also extend the therapeutic potential of established drugs such as doxorubicin and amphotericin B. This article discusses the use of colloidal, particulate carrier systems (25 nm to 1 microm in diameter) in such applications. In particular, systems which show diminished uptake by mononuclear phagocytes are described. Specific targeting of carriers to particular tissues or cells is also considered.

Amphotericin B↗

Electron transfer of hemoglobin at electrodes modified with colloidal clay nanoparticles.

Nanostructured sodium montmorillonite was prepared via a colloidal chemical approach and deposited onto glassy carbon electrodes (GCE). Subsequently, hemoglobin was spontaneously adsorbed onto the clay membrane-modified electrode. The colloidal clay nanoparticles and the adsorbed protein were characterized by scanning electron microscopy (SEM) and atomic force microscopy (AFM). The electrochemical impedance behavior of the system was studied using a microlithographically fabricated interdigitated microsensor electrode (IME). The interaction of the clay nanoparticles with hemoglobin was investigated by UV-VIS spectroscopy and electrochemical methods. The heme protein adsorbed in this way displayed a well-defined electrode process and the electron transfer was confirmed to originate from its heme site. Furthermore, nitric oxide affects the hemoglobin electrochemistry.

Adsorption↗

Electrochemical characteristics of a platinum electrode modified with a matrix of polyvinyl butyral and colloidal Ag containing immobilized horseradish peroxidase.

A new hydrogen peroxide biosensor was constructed, which consisted of a platinum electrode modified by a matrix of polyvinyl butyral (PVB) and nanometer-sized Ag colloid containing immobilized horseradish peroxidase (HRP), and using Co(bpy)3(3+) as mediator in the hydrogen peroxide solution. The electrochemical characteristics of the biosensor were studied by cyclic voltammetry and chronoamperometry. The modified process was characterized by electrochemical impedance spectroscopy and cyclic voltammetry. The HRP immobilized on colloidal Ag was stable and retained its biological activity. The sensor displays excellent electrocatalytic response to the reduction of H2O2. Analytical parameters such as pH and temperature were also studied. Linear calibration for H2O2 was obtained in the range of 1x10(-5) to 1x10(-2) M under optimized conditions. The sensor was highly sensitive to H2O2, with a detection limit of 2x10(-6) M, and the sensor achieved 95% of steady-state current within 10 s. The sensor exhibited high sensitivity, selectivity and stability.

Catalysis↗

Combined LIBD and XAFS investigation of the formation and structure of Zr(IV) colloids.

The solubility of Zr(OH)4(am)--in other words hydrated Zr(IV) oxyhydroxide--is determined by means of coulometric titration (CT), and colloids are detected by laser-induced breakdown when the solubility limit is exceeded. Our results at pH 3-8 demonstrate that the solubility of Zr(OH)4(am) is several orders of magnitude higher than reported classical solubility data for acidic solutions, determined from undersaturation with a less soluble microcrystalline Zr(IV) oxide precipitate. Analysis of extended X-ray absorption fine structure (EXAFS) data shows that the microcrystalline colloids in a 0.1 mol l(-1) Zr aqueous solution at pH 0.2 contain tetrameric units, similar to those present in the structure of ZrOCl2.8H2O. Characterization of the CT solutions by means of EXAFS shows that oligomeric species form as the solubility limit is approached. The current lack of data on equilibrium constants for polynuclear hydroxide complexes prohibits the use of a realistic speciation model to describe the solubility of pH-dependent Zr(OH)4(am). However, the solubility curve is obtained using the mononuclear hydrolysis constants estimated in the present paper, along with the solubility constant (log K'sp=-49.9+/-0.5 in 0.5 mol l(-1) NaCl; log K degrees(sp)=-53.1+/-0.5 at I=0).

Absorptiometry, Photon↗

Determination of proteins at nanogram levels by their quenching effect on large particle scattering of colloidal silver chloride.

A novel quantitative method for the determination of proteins in aqueous solutions has been based on the quenching of the resonance scattering light of colloidal silver chloride in the presence of proteins. The detection limits for eight kinds of proteins (BSA, HSA, egg albumin, human gamma-IgG,alpha-chymotrypsin, E. Coli. alpsase, myoglobin, alpha-casein) were at about 8 ng/mL; the linear ranges of the calibration curves were 10-400 ng/mL under optimal conditions,except for human gamma-IgG (20-400 ng/mL), myoglobin (10-300 ng/mL), and alpha-casein (10-300 ng/mL). Three wavelengths (398 nm, 475 nm, 499 nm) were all suitable for the determination and any acidity from pH 3.0 to pH 9.0 could be chosen. A few non-protein substances at high concentration levels interfered with this method, but this problem could simply be overcome by diluting the samples before the assay. Mechanism studies showed that the quenching effect of proteins on the scattering light of colloidal silver chloride was mainly due to the coagulation of AgCl particles retarded by protein. The method was employed for the determination of total protein in human serum with satisfactory results.

Animals↗

Study of an Au colloid self-assembled electrode and its application to the determination of carbon monoxide.

A novel electrochemical sensor has been developed for the detection of carbon monoxide. The chemically modified electrode, prepared by reaction of cysteine and then an Au colloid of size approximately 15 nm with a platinum microelectrode, has excellent catalytic activity toward carbon monoxide, with an oxidation potential of +600 mV relative to the Ag/AgCl electrode. The CO gas sensor is based on an Au colloid self-assembled modified electrode as working electrode, an Ag/AgCl electrode as reference electrode, a Pt electrode as counter electrode, and a porous film which is in direct contact with the gas-containing atmosphere. The effects on the determination of CO of different internal electrolyte solutions of perchloric acid, hydrochloric acid, sulfuric acid, nitric acid, and phosphate buffer of different concentrations were also studied. The sensor is characterized by a short response time and highly reproducible detection of CO. This sensor can be used in the field of environmental monitoring and control.

Calibration↗

Changing characteristics of a colloid cyst of the third ventricle.

We describe extremely unusual radiological characteristics in a colloid cyst of the third ventricle, where the cyst became dense and its size decreased following a cerebrospinal fluid diversion procedure. Such a course of events has been reported in colloid cysts only twice in the literature.

Adolescent↗

Sentinel lymph node detection with large human serum albumin colloid particles in breast cancer.

Detection of metastatic involvement of lymph nodes is essential for management and prognostic evaluation in breast cancer patients. The success of lymphatic mapping depends on identifying the sentinel lymph node(s) draining the primary tumour. However, when mapping is performed with a radiocolloidal agent, the number of hot lymph nodes varies with the agent and its size, among other factors. In this study, we evaluated prospectively the detection rate of sentinel lymph nodes in breast cancer when injecting large particles (100-600 nm) of human serum albumin colloids (Senti-Scint). In 128 consecutive breast cancer patients without palpable lymph nodes, pre-operative static lymphoscintigraphic mapping of the breast was performed after subcutaneous injection of 15 MBq of the radiocolloid. Lymphoscintigrahic results were compared with intra-operative surgical gamma detection probe and blue dye mapping data. Pre-operative lymphoscintigraphy and surgical gamma detection probe both correctly detected 203 sentinel lymph nodes in 122/128 patients (95%), while blue dye mapping showed only 183 sentinel lymph nodes in 82% of the patients. Only one or two sentinel lymph nodes were identified in each patient, which allowed the surgeon easily to find the sentinel lymph node(s) intra-operatively. In conclusion, lymphoscintigraphy with large particles of human serum albumin colloids is a helpful and reliable procedure for the surgical management of breast cancer.

Adult↗

Sentinel node localization in cutaneous melanoma: lymphoscintigraphy with colloids and antibody fragments versus blue dye mapping.

In stage I cutaneous melanoma, biopsy of the first tumour-draining lymph node (sentinel node, SN) may replace routine elective lymph node dissection (ELND). The patent blue dye (PBD) technique has been shown to be an original method for the localization of the SN, but its sensitivity is sometimes unsatisfactory, depending on the basin where the SN is located. We compared three methods to locate the SN: intraoperative PBD mapping, lymphoscintigraphy (LS) with an aspecific tracer (colloid) and LS with a specific tracer (monoclonal antibody, MoAb). Fifty patients with cutaneous melanoma were enrolled in this study. The day before surgery LS was performed following an intradermal injection of 55 MBq technetium-99m-labelled HSA colloidal particles (25 patients: group A) or 220 MBq of 99mTc-F(ab')2 MoAb 225.28 S (25 patients: group B) around the site of the primary lesion. In group B an equal amount of tracer was injected, as a control, in the contralateral site. Early and delayed images were acquired with a gamma camera and SN(s) marked on the skin. In all 50 patients the PBD technique was also performed immediately before surgery. When a blue node was identified intraoperatively, its radioactivity level was measured with a gamma probe. In the absence of blue coloration, the probe alone was used to detect the SN. Lymphoscintigraphic visualization of SNs was possible in 50/50 patients (100%), a total of 73 SNs (38 in group A and 35 in group B) were found, distributed in 55 basins. Gamma probe detection (GPD) allowed the identification of SNs in 49/50 patients (98%), and 72 SNs in 54 basins were localized. By contrast, using PBD, SNs were stained only in 40/50 patients (50 SNs in 40 basins). A tumour-positive SN was histologically proven in 13 patients (26%). In group B, no increase uptake was observed in the seven positive SNs (6/25 patients) compared with the contralateral uninvolved nodes. In conclusion this study demonstrates that LS combined with GPD is a safe method for detecting SNs and is more sensitive than the PBD technique. The use of MoAb fragments did not show any advantage over the non-specific tracer.

Adolescent↗

A phase I study of 9-aminocamptothecin as a colloidal dispersion formulation given as a fortnightly 72-h infusion.

PURPOSE: A phase I pharmacologic study was undertaken to determine the maximum tolerated dose (MTD), to characterize the pharmacokinetic profile, and to evaluate all toxicities of the aqueous colloidal dispersion formulation of 9-aminocampothecin (9-AC). METHODS: 9-AC was administered as a constant 72-h i.v. infusion every 2 weeks to adult cancer patients at dose rates ranging from 25 to 59 microg/m2 per hour. RESULTS: Twenty patients with refractory solid tumors received a total of 86 courses of 9-AC at four dose levels. Myelosuppression, particularly granulocytopenia, was the most common toxicity. Two of six assessable patients entered at 59 microg/m2 per hour had dose-limiting toxicity (grade 3 diarrhea or need for a 2-week treatment delay to permit granulocyte recovery), whereas lower doses were well tolerated. At the recommended dose, 47 microg/m2 per hour, the average steady-state plasma levels (Cpss) and area under the curve (AUC) of 9-AC lactone and total drug were 15 and 75 nM, and 1034 and 4220 nM.h, respectively. A moderate correlation was seen between 9-AC lactone AUC and the percentage decrease in granulocytes. CONCLUSIONS: The recommended phase II dose of 9-AC colloidal dispersion as a 72-h infusion every 14 days is 47 microg/m2 per hour (1.13 mg/m2 per day). The Cpss of 9-AC lactone at this dose exceeded the 10 nM threshold level for preclinical activity.

Acetamides↗