Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ARTIFICIAL LIMBS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85Linked to original sources

Using practice led design research to develop an articulated mechanical analogy of the human hand.

Contemporary prostheses have developed from small iterations on moderately successful archetypes. This has resulted in modern designs that can either be termed cosmetic or functional, with neither attribute being fully satisfied. A new strategy is needed to develop a generation of upper-limb prostheses that will integrate both cosmetic and functional requirements in a single device. It is hypothesized that design principles applicable to a new generation of prostheses will result from exploring close analogies to the human upper limb. A method of practice led design research has been adopted to explore appropriate analogies, using the production of physical models to elucidate the design problem to the design team and other interested parties. This method uses a consciously iterative approach whereby criticisms and lessons learnt in the development of early models are embodied in subsequent models. This paper describes the first iterative cycle. It includes a critical review of the devices currently available and a study of mechanical analogies to original anatomy which form two of the inputs to the development of a skeletal model hand. It details the lessons learnt from this study and concludes on the wider application of practice led design research in medical engineering.

Artificial Limbs↗

A multifunctional prosthesis control system based on time series identification of EMG signals using microprocessors.

This paper describes a real-time system for separation among several limb functions, in order to provide multifunctional control of an upper-limb prosthesis for above-elbow amputees. The system employs microprocessor hardware and is based on identification of voluntary myoelectric signals resulting from isometric contractions of the musculature of the residual limb, and on subsequent discrimination of these signals for control of the several degrees of motion of the prosthesis. The system requires only one to two electrode sites. (Contrary to the usual placement of electrode pairs directly over specific muscle bellies, to eliminate crosstalk, we prefer to place our electrode pair between muscles so as to acquire the different weakly-correlated signals associated with each of several different voluntary functions). The system satisfies the various practical constraints of weight, volume, and speed, as arise in practical prostheses. Preliminary amputee tests on the system have resulted in an 85 percent success rate using 8-bit double-precision micro-computer hardware.

Adult↗

Interface load analysis for computer-aided design of below-knee prosthetic sockets.

A finite-element analysis is made for the compression of soft tissues of the residual lower limb contained in a prosthetic socket. The analysis is relevant to static loading during stance in a patellar-tendon-bearing, below-knee design of socket. Values of Young's modulus are obtained experimentally for use in the model. One of the main objectives is to study the sensitivity of the loading to these values and also to other assumed conditions. Using direct pressure at the limb/socket interface and vertical stiffness as indicators, changes in material properties, socket alignment and socket rectification are investigated; assumptions about the frictional characteristic at the interface are seen to be critical in determination of load distribution. This type of analysis may provide the next stage of refinement for computer-aided socket design systems.

Artificial Limbs↗

Adaptive prosthetics for the lower extremity.

The potential for lifestyle recovery is tremendous for most lower extremity amputees. The amazing and ever-expanding array of adaptive prosthetics can help make the devastating loss of amputation more bearable for patients, their families, and their health care team. The new amputee, in a state of shock and grief, does not know what his or her prosthetic options are. It is crucial that the surgeon is knowledgeable about what the patient can have and what the patient needs to ask for. Dana Bowman stated: Ideally, the new amputee should say to their doctor, "I'd like my leg to be lightweight, flexible, durable, comfortable. I want to do sports or I want to ride bikes with my kids." Whatever it is they like to do. I was told I would never be able to wear two dynamic feet and that my sky diving days were over. I said, "Well how do you know? Can't I try?" It took years to find out what I could have and then to find people to help me get it. The prosthetic prescription the physician writes is the patient's gateway to the kind of prosthetics that will enable him or her to pursue the activities of their life. Often, new amputees end up with the bare minimum prosthesis, which can cause problems with comfort and mobility. A poorly designed or badly fitting prosthesis is as disabling as the actual amputation. When the surgeon can help the amputee and his or her family understand what kind of prosthetic choices are available, it establishes an optimistic outlook that is highly beneficial to the entire recovery process physically and mentally. "When I lost my leg, if someone would have told me that I could at least try to run again, that would have meant a lot," said Brian Frasure. "Getting that positive mental attitude is every bit as important as having good medical and prosthetic care." By asking probing questions about the patient's preamputation lifestyle and postamputation goals, the physician can write a prescription for truly adaptive prosthetics. The surgeon should consider the economic benefits of asking for a waterproof leg for an older adult that he or she can use for more stability in the shower and that can go a long way toward preventing fracture and other injuries. There are economic considerations for a younger amputee, asking for an energy-storing foot or an adjustable ankle so that he or she can be more active and independent and probably avoid the health risks associated with depression, inactivity, or obesity. If all patients received a contoured, flexible, dynamic socket from the beginning, years of medical problems and treatment for injury to the residual limb could be avoided. The initial prosthetic prescription is probably the best opportunity the patient ever will have to get the adaptive prosthetics that can meet his or her needs best. It also establishes a precedent with the payer for quality prosthetic care and begins educating all payers about what prosthetic patients can and should have. Insurance companies may resist the idea of a second prosthesis or of specialized components that increase the cost of the initial prosthesis. Physicians, patients, and the multidisciplinary team can work together, however, to pursue the most complete prosthetic coverage possible. For the prosthetic user, it is the difference between being restored to a full and active life or sitting back and becoming a spectator.

Adult↗

A robust, real-time control scheme for multifunction myoelectric control.

This paper represents an ongoing investigation of dexterous and natural control of upper extremity prostheses using the myoelectric signal (MES). The scheme described within uses pattern recognition to process four channels of MES, with the task of discriminating multiple classes of limb movement. The method does not require segmentation of the MES data, allowing a continuous stream of class decisions to be delivered to a prosthetic device. It is shown in this paper that, by exploiting the processing power inherent in current computing systems, substantial gains in classifier accuracy and response time are possible. Other important characteristics for prosthetic control systems are met as well. Due to the fact that the classifier learns the muscle activation patterns for each desired class for each individual, a natural control actuation results. The continuous decision stream allows complex sequences of manipulation involving multiple joints to be performed without interruption. Finally, minimal storage capacity is required, which is an important factor in embedded control systems.

Action Potentials↗

Control of the residual tibia in transtibial amputation.

Eight transtibial amputees had localized unremitting discomfort and pain in the distal anterior residual limb during prosthetic wear while weightbearing. Modification of the prosthetic socket did not change this pain. It was not consistent with "phantom limb" or causalgia/reflex sympathetic dystrophy-type etiologies. Thirteen randomly selected, pain-free, transtibial amputees were selected for comparison. The subjects in both groups used similar total-contact, "patellar tendon-bearing" prosthetic sockets fabricated and aligned with similar technique. The angles formed between the femur and tibia, femur and prosthetic socket, and tibia and socket were measured. Significant differences were found at each angle measurement between those patients who experienced pain and those who did not. The variable of tibia length had no effect. We conclude that bone alignment within the transtibial total-contact prosthetic socket may be partially dependent on surgical technique and not solely on prosthetic socket configuration.

Amputation, Surgical↗

Computer-aided design and computer-aided manufacturing (CAD/CAM) in prosthetics.

Computer-aided design and computer-aided manufacturing (CAD/CAM) systems for the design and manufacture of limb prostheses have recently become commercially available. However, rigorous evaluations of these systems have not been performed to determine whether they produce sockets that fit as well as or better than sockets made using conventional design methods. A controlled evaluation protocol, in which computer-designed sockets are compared with conventionally designed sockets, has been developed and pilot tested at the authors' facility. A full trial of one of the commercially available systems for transtibial sockets is currently in progress. In preliminary findings, the CAD/CAM socket was preferred by one-half of the first 20 subjects. During the course of this trial, it was noted that the CAD/CAM technique seems to be better suited to some prosthetists than others.

Adult↗

Current evaluation of hydraulics to replace the cable force transmission system for body-powered upper-limb prostheses.

Present body-powered upper-limb prostheses use a cable control system employing World War II aircraft technology to transmit force from the body to the prosthesis for operation. The cable and associated hardware are located outside the prosthesis. Because individuals with arm amputations want prostheses that are natural looking with a smooth, soft outer surface, a design and development project was undertaken to replace the cable system with hydraulics located inside the prosthesis. Three different hydraulic transmission systems were built for evaluation, and other possibilities were explored. Results indicate that a hydraulic force transmission system remains an unmet challenge as a practical replacement for the cable system. The author was unable to develop a hydraulic system that meets the necessary dynamic requirements and is acceptable in size and appearance.

Amputees↗

Loads in hip disarticulation prostheses during normal daily use.

As a result of deficiency at birth, disease or trauma, there are people who have no limbs from the hip joint downwards. These people have no possibility of locomotion without the use of other devices such as wheelchairs or hip disarticulation prostheses. As these prostheses are used by people of all ages, people who are different in their grade of physical activities and their weights, the prostheses are subject to different stresses related to these different circumstances. The European Level 2 Draft Standard prEN 12523: 1966 "External limb prostheses and external orthoses - requirements and test methods" contains strength requirements for lower limb prostheses. These requirements shall be verified, where appropriate, by the application of the International Standard ISO 10328 "Prosthetics - Structural testing of lower limb prostheses" and ISO/FDIS 15032 "Prosthetics: Structural testing of hip prostheses". In order to allow the prostheses to be tested to the stresses that are experienced in real life, it is necessary to measure the stress that is induced in the prostheses while the patient is in an everyday situation, such as walking on level floor, walking on grass and/or walking on an uneven surface. This work is concerned with the acquisition of loads generated in hip units of hip disarticulation prostheses by amputees during various activities. More than 30 patients were tested in Germany, France, and Belgium. The measurements were carried out with financial support from the European Commission and coordinated by the secretariat of CEN TC 293.

Amputees↗

Diplopodia with double fibula and agenesis of tibia. A case report.

A 14-year-old girl with a congenitally deformed and shortened right leg and foot is described. The patient could not bear weight on the deformed limb and had to hop on the left leg. The deformed foot faced backwards and had nine toes. The right leg was shorter than the left by 26 centimetres. Radiologically, the lower end of the right femur was ill-developed and there was no knee joint. There were two fibulae and the tibia and the patella were absent. A through-knee disarticulation was done and a prosthesis fitted later. The amputated leg and foot were dissected. Many of the muscles in the leg and foot were duplicated. There were two calcanei, one talus, one navicular, two cuboids and four cuneiforms. Ther were nine metatarsals, and all the toes had three phalanges except for one which had two.

Adolescent↗

[Anxiety and depression after loss of a lower limb].

A good number of psychosocial-, disease-, and disability-related variables influence the adaptation process after the loss of a lower limb. In this case psychological problems, as a result of a failed adaptation process, are common. Of the 75 patients examined who had an amputation of a lower extremity 27% showed increased depression and 25% increased anxiety scores; 18.3% showed higher than normal scores in both categories. Regression analysis showed that in addition to pain reception poor acceptance of the prosthesis is an important predictive factor for the development of psychological disorders and diseases like anxiety and depression. Therefore, measures for psychological diagnostics and care should be initiated soon after the amputation to prevent psychological abnormalities. Here interdisciplinary management and cooperation of the professions involved in the care of the patient are recommended.

Adolescent↗

The mobility outcome for amputees with rheumatoid arthritis is poor.

This study examines the reasons for amputation of the lower limb in 11 patients with RA. The reasons for amputation were ischaemia due to peripheral vascular disease; rheumatoid vasculitis; or complications of knee arthroplasty. Delayed healing was common in patients on steroid therapy. The patients had difficulty donning and doffing their prostheses due to poor hand function and impaired agility. Walking training and rehabilitation were slow and tended to precipitate a generalized flare-up of disease activity. Rheumatoid nodules developed on pressure points between stump and socket. Despite these problems the majority of patients preferred to wear a prosthesis for help in transferring in and out of the wheelchair, to complete their appearance and for limited mobility. Most found using an electric powered indoor wheelchair helped maintain their independence.

Adult↗

Health-related quality of life in patients with transtibial amputation and reconstruction with bone bridging of the distal tibia and fibula.

BACKGROUND: Bone-bridging (arthrodesis of the distal tibia and fibula) at the time of transtibial amputation is a controversial operative technique that is anecdotally reported to improve the weightbearing capacity of the residual limb and to decrease residual limb discomfort. METHODS: Thirty-two consecutive patients with multiple diagnoses had transtibial amputation with a distal tibial-fibular bone-bridge, all done by a single surgeon (MAP). At an average of 16.3 months after surgery all patients completed the Prosthetics Evaluation Questionnaire (PEQ), a validated outcomes instrument specifically created to evaluate quality of life and functional demands in patients with a lower extremity amputations. Their responses were compared with those of 17 preselected, highly functional transtibial amputees from two academic medical centers who previously had transtibial amputations using a traditional non bone-bridge operative technique; their time since amputation averaged 14.7 years. RESULTS: The "nonselected" consecutive patients with a bone-bridged residual limb scored higher (more favorable) in the Ambulation (p = 0.037) and Frustration (p < 0.001) domains of the PEQ and lower (less favorable) in the Appearance (p = 0.025) subscale. Their scores were similar in the other six domains. CONCLUSIONS: Patients of multiple ages with multiple diagnoses who had bone-bridging of the distal tibia and fibula at the time of transtibial amputation had scores on a validated outcomes instrument that were better than or comparable to those of a selected group of highly functional transtibial amputees. The results of this study suggest that bone-bridging at the time of transtibial amputation may enhance patient-perceived functional outcomes.

Adolescent↗

Subjective evaluation of the UCBL polycentric knee linkage by active above knee amputees. A prospective trial.

In this study 20 active male above knee amputees were fitted with prostheses incorporating prototype UCBL four-bar polycentric knee units. The subjective responses of the amputees were evaluated in a prospective fashion. Additional information concerning the short-term durability and mechanical behavior of the device is presented. The average followup was 12.3 months. Sixteen of the 20 subjects felt that they benefited from the device, and seven of these stated that the research prosthesis was superior to all previous devices that they had used. Four subjects stated that they had received little or no benefit from the research limb. Previous levels of function and the ease of performance of specific activities were maintained or enhanced in almost all subjects. Most subjects felt that the ease of walking on inclines was improved, and found the increase in knee flexion afforded by the mechanism to be an advantage. Early in the study, problems were encountered due to air leaks in the pneumatic swing-phase control units and to excessive wear of the aluminum linkage pins. These problems were corrected easily, and the devices were found to function well during the remainder of the study. Given the encouraging results from this preliminary clinical trial, we conclude that further study and clinical application of the UCBL four-bar polycentric knee are indicated.

Adult↗

An amputee visitor program as an adjunct to rehabilitation of the lower limb amputee.

Based on evaluation of the rehabilitative needs of patients who have had a leg amputated because of cancer, an amputee visitor program was developed. The visitor is a cancer amputee who has successfully completed rehabilitation. About 5 days after a patient's amputation, the visitor sees the patient, telling of personal experiences, answering the patient's questions, and showing the prosthesis. The visitor later evaluates the visit on a data collection sheet. From 1 to 6 months after the visit, the patient and, if possible, a relative are interviewed to determine their long-term reaction to the program. During a 30-month period, 65 new patients were seen and evaluated by two visitors. Sixty (92%) responded favorably to the visit. In follow-up interviews with 36 patients, 33 (92%) said the visit substantially improved their outlook. In summary, our data indicate that the amputee visitor contributes significantly to rehabilitation.

Amputation, Surgical↗

The Trinity Amputation and Prosthesis Experience Scales and quality of life in people with lower-limb amputation.

OBJECTIVES: To undertake preliminary research into quality of life (QOL) for a group of people with a lower-limb amputation and to investigate what aspects of the "prosthetic experience" are most strongly associated with QOL using the Trinity Amputation and Prosthesis Experience Scales (TAPES). DESIGN: Cross-sectional survey. SETTING: Prosthetic limb fitting center. PARTICIPANTS: Sixty-three people older than 18 years with unilateral lower-limb amputation. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: The TAPES and the World Health Organization Quality of Life Questionnaire-Brief Version. RESULTS: There were no significant differences in any of the QOL domain scores (physical health, psychological, social relationships, environmental) arising from age, gender, level of amputation, or cause of amputation. However, there were significant differences depending on the length of time living with the prosthesis and the degree of prosthetic use. Stepwise regression identified different significant predictors for each domain of QOL. CONCLUSIONS: These findings support the claim that the TAPES can be used to evaluate QOL for this patient group. Further research is warranted to learn how sensitive the scale and its items are to change in clinical status.

Adult↗

An unusual complication of a myoelectric prosthesis.

This clinical note describes an unusual and previously unreported complication of wearing a myoelectric prosthesis in a child with congenital upper limb deficiency. After an initial period of wearing a cosmetic prosthesis, he was provided with a child's trans-radial myoelectric prosthesis with a Steeper Scamp Electric hand at the age of 21 months. After successful and uncomplicated use of this prosthesis for 2 years--a sudden onset of burns of the skin of the stump underlying the single electrode site was noted. The cause of the burns was thought to be due to heat generated from electrical failure possibly from ingress of moisture. This complication has not before been experienced in the authors' centre, nor has it been reported in the literature. While constant improvements are being made in the field of electrically powered prosthesis, the rehabilitation team should be aware of this unusual complication.

Amputation Stumps↗

Gait analysis in prosthetics: opinions, ideas and conclusions.

A review was performed of the literature of the last eleven years (1990-2000) with the topic: "clinical use of instrumented gait analysis in patients wearing a prosthesis of the lower limb". To this end a literature search was performed in Embase, Medline and Recal. Forty-five (45) articles were identified for study from which 34 were reviewed. The reviews were divided into five subtopics: 1) adaptive strategies in gait (12 studies); 2) the influence of different parts of the prosthesis on gait (12 studies); 3) pressure measurements in the socket in gait studies (4 studies); 4) the influence of the mass of the prostheses on gait (5 studies); 5) energy considerations in gait (2 studies). A considerable part of the studies concerned the adaptive strategies of the amputee in walking and running and the evaluation of different prosthetic feet. All aspects and outcomes were reviewed concerning the clinical relevance.

Adaptation, Physiological↗