Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “diagnostics”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84Linked to original sources

Veterinary diagnostic laboratories in developing countries: the challenge of credibility.

The problems facing veterinary diagnostic laboratories in developing countries range from simple problems, such as limited funds to keep good personnel or obtain equipment, supplies, reagents or training, to the more complex problems of designing and executing appropriate sample collection schemes for disease surveillance of evaluating the performance characteristics of a new diagnostic assay. While many developing countries are addressing these problems independently and a number of international and national organisations provide various forms of external support, the Office International des Epizooties (OIE) must continue in its critical role to provide guidelines for the most appropriate diagnostic assays for trade purposes and the development of the primary reference reagents for these assays. In addition, the OIE should take the lead in development of quality management guidelines for veterinary diagnostic testing laboratories. Without these guidelines and standards, diagnostic laboratories in developing countries will have difficulty in gaining the credibility necessary to help improve the positions of their countries in the international trade of livestock and livestock commodities.

Animal Diseases↗

Percutaneous needle biopsy of musculoskeletal lesions. 1. Effective accuracy and diagnostic utility.

The utility of a diagnostic test depends not only on its accuracy but also on how its results affect clinical management. We reviewed the results of 102 percutaneous needle biopsies to determine the accuracy, effective accuracy, and diagnostic utility of the procedure. We found percutaneous needle biopsy was similarly accurate in identifying suspected metastatic lesions (82%, n = 44), suspected musculoskeletal infections (90%, n = 29), and suspected primary musculoskeletal tumors (83%, n = 29). Effective accuracy, or accuracy discounted for results with limited clinical utility, was highest in identifying suspected metastatic deposits (77%), slightly lower in suspected infections (72%), and lowest in suspected primary tumors (59%). Diagnostic utility (the probability-weighted sum of the utility values of all possible outcomes of a diagnostic test) for identifying metastatic deposits and infections exceeded that for suspected primary tumors. Percutaneous needle biopsy in patients with suspected primary tumors must be performed with the knowledge that, even though technically accurate, such biopsies may be of limited clinical value. Percutaneous needle biopsy of suspected metastatic lesions and suspected infections, on the other hand, offers high accuracy and high diagnostic utility.

Adolescent↗

Volumetric high-resolution CT in the diagnosis of interstitial lung disease and bronchiectasis: diagnostic accuracy and radiation dose.

OBJECTIVE: The purpose of this study was to evaluate the diagnostic accuracy and radiation dose of volumetric high-resolution CT in the diagnosis of interstitial lung disease and bronchiectasis when four contiguous sections were acquired at each of three levels. The potential benefits were weighed against the increased radiation dose of multiple scans. SUBJECTS AND METHODS: High-resolution CT scans of four contiguous sections were obtained at each of three locations (the aortic arch, the carina, and 2 cm above the diaphragm) in 50 consecutive patients (mean age, 44 years old) with known or suspected interstitial lung disease or bronchiectasis who were referred for evaluation with high-resolution CT. Each individual scan was analyzed for the presence of motion-induced streaking, blurring, or doubling. The diagnostic information contained in each set of four scans was compared with that contained in the first of the four scans in the set. RESULTS: Motion degraded at least one of the four images in each set in 69 (46%) of 150 volumetric acquisitions. When the full set of four images was considered instead of just the first scan from the set, the number of motion-free studies in patients with suboptimal respiratory suspension was increased by 40% (from 99 to 139). Diagnostic accuracy was improved as more features were identified on contiguous scans: the sensitivity of the first scan compared with that of the complete set of four scans was 84% for the detection of bronchiectasis, 97% for ground-glass opacity, 88% for honeycombing, 88% for septal thickening, and 86% for nodular opacities. Although the integral radiation exposure for a set of four CT scans was 2.8 times that of a single scan obtained with standard technique, peak skin exposure was unchanged. Slightly increased image noise with the reduced technique compromised diagnostic ability in 6% of studies. CONCLUSION: The use of volumetric high-resolution CT increased diagnostic accuracy, particularly for bronchiectasis at the lung bases, without increasing peak skin radiation exposure. With the availability of four contiguous scans per anatomic level, the subjective confidence in interpretation and number of motion-free studies also increased.

Adult↗

The demand side of the job market for diagnostic radiologists and radiation oncologists: hiring by physician groups in 1995.

OBJECTIVE: The American College of Radiology sought to assess the hiring activities of radiology groups in 1995, the 1995 employment market for diagnostic radiologists and radiation oncologists, and changes in the employment market since 1991. MATERIALS AND METHODS: We mailed surveys about recruitment and hiring to a stratified random sample of 600 radiology groups in the United States; 85% responded. The responses were weighted to show what they would have been if all of the approximately 3150 radiology groups in the United States had answered the survey. The findings were compared with similar surveys conducted in 1994 and 1991. RESULTS: In 1995, 31% (+/- 1% [SE]) of radiology groups actively recruited diagnostic radiologists or radiation oncologists, seeking to fill 1423 (+/- 119) openings. These figures represent a progressive decline from the 50% of groups recruiting and 2255 positions offered in 1991. In 1995, radiology groups filled 85% of available positions, compared with 76% in 1994 and 71% in 1991. In 1995, positions available because of expansion of radiology groups numbered 613 (+/- 73), considerably fewer than the estimated 720-position increase that takes place each year in the number of posttraining diagnostic radiologist and radiation oncologists in practice. In 1995, general diagnostic radiology accounted for approximately 48% of the full time-equivalent radiologists sought; radiation oncology, 11%; and the diagnostic subspecialties, 41%. We found few statistically significant differences among specialty and subspecialty fields in the percentage of available positions filled. Private, nonacademic groups offered 77% of their positions on a partnership track basis. Groups strongly affected by managed care recruited fewer radiologists and offered fewer expansion positions than similar groups that were less affected by managed care. However, managed care did not influence whether positions were offered on a partnership basis. CONCLUSION: Available positions continued to decline, and the shortfall of expansion positions relative to the annual growth in the workforce may generate serious employment problems. Managed care is having a negative effect on employment opportunities for radiologists. Gaining employment remains about equally difficult, regardless of field. The approximately 200 positions that remained unfilled at the end of the 1995 hiring season did not result from a mismatch between radiologists' skills and the qualifications that radiology groups were seeking.

Data Collection↗

The employment market for 1996 diagnostic radiology and radiation oncology graduates: training program directors' point of view.

OBJECTIVE: In light of concerns about the job market, we describe the employment situation for 1996 graduates and the status and plans of training programs. MATERIALS AND METHODS: In April-May 1996, and in a December follow-up, we surveyed all radiation oncology residency directors and a 50% random sample of diagnostic radiology residency directors about the employment situation of their 1996 residency and fellowship graduates and about their programs. One hundred percent of those surveyed responded. We compared findings with similar 1995 surveys. Differences were assessed with t tests, with a p value less than or equal to .05 as the test of significance. RESULTS: Unemployment 6 months after graduation was 0.8% for diagnostic fellows and less for other categories. Approximately 91% of graduates had positions that reasonably matched their training and personal employment goals. Our survey showed that programs have reduced beginning residency slots by 6% in diagnostic radiology and 4% in radiation oncology over the last 3 years. Program directors plan additional reductions of 3% and 29%, respectively, for total reductions in diagnostic radiology of 9% and in radiation oncology of 33%. Many observers were dismayed because of the low percentage of available slots that filled in the 1996 National Resident Matching Program. However, as in previous years, by late April to mid May 1996, more than 92% of beginning-year residency slots were filled. CONCLUSION: Unemployment continues to be low. "Soft" indicators such as the percentage of graduates with unsuitable positions show no deterioration. However, if major surpluses of diagnostic radiologists or radiation oncologists are pending, both the reductions in program size and the failure to fill all available slots are, to date, too minor to offer significant relief. Given the small size of actual reductions so far, the reported plans for large reductions of radiation oncologists seem questionable.

Data Collection↗

The job market in diagnostic radiology 1999: updated findings from a help wanted index of job advertisements.

OBJECTIVE: The purpose of this article is to report 1999 data on the job market in diagnostic radiology detected using a help wanted index of job advertisements and to profile trends in practice type, location, and subspecialty using our previously published data as a basis for comparison. MATERIALS AND METHODS: Each advertised job for a diagnostic radiologist in the American Journal of Roentgenology and RADIOLOGY: between January 1991 and December 1999 was coded by practice type, location, and subspecialty. RESULTS: In 1999, 3926 positions were advertised for diagnostic radiologists, representing a 75% increase from 1998. Private practice jobs, which represented 53% of advertisements from 1991 through 1994 and 64% of ads from 1995 through 1998, increased to 66% of ads in 1999. Geographic trends in 1999 were characterized by a relative increase of jobs in the Midwest and California and a decrease in percentage (but increase in total number of ads) in the Northeast and Southwest. The demand for subspecialists continued in 1999, with only 34% of ads placed for general radiologists. A relative increase in demand for neuroradiologists, mammographers, and abdominal imagers was also seen in 1999 in comparison with previously published data from 1995 through 1998. CONCLUSION: The demand for diagnostic radiologists continues to rise, with more ads placed in 1999 than any other year from 1991 through 1998. Using a help wanted index of job advertisements, we have created an indicator of changes in the diagnostic radiology job market with specific reference to practice type, geographic location, and subspecialty training.

Advertising↗

Hiring of diagnostic radiologists in 1998.

OBJECTIVE: We sought to determine the 1998 hiring activities of physician practices with respect to diagnostic radiologists. MATERIALS AND METHODS: A survey was mailed to a sample of 970 radiology practices in the spring through fall of 1999; 73.0% responded. Responses were weighted to represent all practices in the United States providing diagnostic radiology services. Findings were compared with results of similar surveys from previous years. RESULTS: In 1998, multiradiologist groups sought to hire 2299 (+/-148 [standard error]) diagnostic radiologists, an increase of 20% from 1977. Positions offered in 1998 were split almost equally between expansion positions and replacements for those who had left a practice. Another 422 (+/-58) positions had been vacated that practices did not seek to refill. In 1998, 621 (+/-57) diagnostic radiologists left active practice, which is more than the usual number of approximately 400 annually but less than the approximately 800 of 1996 and 1997. There was no significant association between hiring activity and the self-perceived effect of managed care on a group. CONCLUSION: The pace of hiring and turnover of diagnostic radiologists increased in 1998. Positions available continue to exceed radiologists available to fill them; the excess was approximately 330 positions, which is not significantly different from the excess reported for 1997, but is higher than the (not statistically significant) net shortfall of 51 positions estimated for 1996.

Data Collection↗

Findings in 2002 from a help wanted index of job advertisements: is the job-market shortage of diagnostic radiologists easing?

OBJECTIVE: The goal of this study is to present the most recent data on the diagnostic radiology job market in the United States using a help wanted index of job advertisements. MATERIALS AND METHODS: All diagnostic radiology positions advertised in the American Journal of Roentgenology and Radiology from January through December 2002 were coded by practice type, geographic location, and subspecialty. Data were compared with the previously published results from 1991 through 2001. RESULTS: From January through December 2002, 5117 positions were advertised for diagnostic radiologists, representing a 10.4% decrease from 2001. The 12-month rolling average of job advertisements peaked at 488 in February 2002 and dropped to 432 by December 2002, a level not seen since August 2000. In 2002, 42.7% of positions advertised were academic, representing a steady increase from 34.0% in 1999. When comparing the 4-year periods 1999-2002 and 1995-1998, a statistically significant proportional increase was found for positions advertised in the Midwest. Statistically significant relative increases were also observed for the subspecialties of abdominal radiology, mammography, neuroradiology, pediatric radiology, chest radiology, and nuclear medicine. Statistically significant relative decreases were seen in general and vascular and interventional positions. CONCLUSION: The absolute demand for diagnostic radiologists nationwide appears to have stabilized during 2002, albeit at a level much higher than in previous years, and may be decreasing. A split seems to have appeared in the market between academia and private practice. Current policy should be directed toward increasing the supply of diagnostic radiologists, especially academicians.

Advertising↗

Limited diagnostic agreement of quantitative sonography of the radius and phalanges with dual-energy x-ray absorptiometry of the spine, femur, and radius for diagnosis of osteoporosis.

OBJECTIVE: The aim of our study was to evaluate the diagnostic agreement of quantitative sonography of the radius and proximal phalanx and dual-energy X-ray absorptiometry (DXA) of the radius, lumbar spine, and femoral neck for the detection of osteoporosis. MATERIALS AND METHODS: In 95 women (mean age, 53 +/- 13 years) and 26 men (mean age, 53 +/- 13 years), DXA measurements of the lumbar spine (posterior-anterior, L1-L4) and the femoral neck, as well as quantitative sonography of the radius and proximal phalanx of the third finger were obtained. The percentage of patients below a given threshold was calculated for each imaging technique. A T score of less than -2.5 indicated presence of osteoporosis. Diagnostic agreement in identifying individuals with osteoporosis was assessed using kappa scores. RESULTS: Between 14% and 22% of the patients were classified as osteoporotic after DXA of the various regions of interest of the radius, 31% after DXA of the spine, 43% after DXA of the femoral neck, 32% after quantitative sonography of the distal radius, and 34% after quantitative sonography of the phalanx of the third finger. Correlation coefficients between T values for quantitative sonography and those for DXA varied between not significant and 0.54 at the different regions. Kappa analysis showed the diagnostic agreement among quantitative sonography and DXA to be fair to moderate (kappa = 0.38-0.48). The highest agreement was between quantitative sonography of the proximal phalanx of the third finger and DXA of the total radius (kappa 0.48; p < 0.05). CONCLUSION: Considerable diagnostic disagreement exists between quantitative sonography and DXA of the forearm, as is true for most quantitative techniques in the assessment of skeletal status. The lack of correlation makes quantitative sonography impractical for routine diagnostic use but might characterize different parameters related to bone quality.

Absorptiometry, Photon↗

[Diagnostic approach to solitary peripheral pulmonary lesions].

INTRODUCTION: Peripheral localization and lack of symptoms are reasons why it is difficult to establish the diagnosis of peripheral pulmonary lesions commonly of malignant nature. Therefore thoracotomy often represents a diagnostic and therapeutic method at the same time. There is a need to define an adequate and optimal diagnostic approach to these lesions in order to establish their etiology, if possible, at low costs. MATERIAL AND METHODS: This retrospective study included 50 patients with peripheral solitary pulmonary lesions (PSPL) who underwent thoracotomy at the Institute of Lung Diseases in Sremska Kamenica. In all patients both bronchoscopy and transthoracic puncture were performed prior to surgery. Having evaluated the diagnostic procedures, their proper sequence has then been applied in the prospective group of another 50 patients admitted to the Institute for similar lesions. RESULTS: In the retrospective group the etiology of PSPL was established by bronchoscopy in 4% and using transthoracic puncture in 58% of patients, with sensitivity, specificity and accuracy of 78.78%, 100% and 85.1%, respectively. In the prospective group, transthoracic puncture (TTP) provided the final diagnosis in 70% of patients, with 86.2% sensitivity, 100% specificity and 90% accuracy. CONCLUSION: Transthoracic puncture is a method of choice in preoperative diagnostics of solitary peripheral pulmonary lesions, quite like thoracotomy in cases where applied diagnostic procedures were inefficient.

Adult↗

The Gordon Diagnostic System and WISC-III Freedom from Distractibility Index: validity in identifying clinic-referred children with and without ADHD.

Gordon Diagnostic System and WISC-III scores for clinic-referred 6- to 16-yr.-olds (184 with ADHD Combined Type and 46 without ADHD) were analyzed to evaluate the combination of scores and cutpoints that maximized diagnostic accuracy. Using an "ADHD cutpoint" of IQ minus the GDS Composite score > or = 13, 87.8% of the children were correctly identified as having or not having ADHD. IQ minus Freedom from Distractibility > 0 yielded 73.5% accuracy. When the two meaures were combined to create new criteria (IQ minus GDS Composite > or = 13 or IQ minus Freedom from Distractibility > or = 11), diagnostic accuracy increased to 90.9% and negative predictive power improved substantially. Diagnostic agreement between the Gordon Diagnostic System and Freedom from Distractibility was 70%, suggesting that the two tests measure both similar and unique traits.

Adolescent↗

Diagnostic efficiency of biological markers in blood serum on prostate cancer: a comparison of four different markers and 12 different methods.

Serum-acid phosphatase as measured by nine different methods, serum prostate-specific antigen, cancer antigen CA-50, and creatine kinase BB isoenzyme have been evaluated and compared with respect to efficiency in differentiating between prostate cancer and benign hyperplasia. The patient material consisted of 92 prostate cancer patients (59 untreated, and 33 previously treated), 106 patients with benign hyperplasia and 66 patients with non-prostatic urological diseases. The cancer group was classified according to the TNM-system, and also graded according to histopathological findings. The following main conclusions were drawn. Acid phosphatase activity, when measured with continuous monitoring procedure (substrate: alpha-naphthyl phosphate), showed on the average slightly, but statistically not significant higher diagnostic efficiency than when measured with conventional two-point discontinuous monitoring method (substrate: p-nitrophenyl phosphate). There was no or only marginal differences in diagnostic efficiency between activity measurements of the total acid phosphatase and the tartrate-labile fraction, and also between activity measurements and immunological measurements (PAP-RIA and PAP-IEA). Prostate-specific antigen was found to have statistically significant higher diagnostic efficiency than acid phosphatase, the former being positive in 17 of 25 patients with prostate cancer without distant metastases, and in six of 11 patients classified as T0-2 M0. Cancer antigen CA-50 and creatine kinase BB isoenzyme appeared to be of little diagnostic value. From a cost-effective point of view, total or tartrate-labile prostatic acid phosphatase activity, as measured by continuous monitoring technique with alpha-naphthyl phosphate as substrate, is suggested suitable as a first-choice parameter both for diagnostic and monitoring purposes with respect to prostate disease. Prostate-specific antigen may give additional information, and should be considered analysed on special request.

Acid Phosphatase↗

Irritable bowel syndrome--prognosis and diagnostic safety. A 5-year follow-up study.

The irritable bowel syndrome is the commonest diagnosis in gastroenterological clinics, although diagnostic criteria and investigatory programs vary. To elucidate the diagnostic safety and prognosis of the syndrome, a retrospective study was conducted. One hundred and twelve consecutive patients with irritable bowel syndrome as the final and only abdominal diagnosis in the period 1977-79 were followed up in 1984. Seventeen patients died during the follow-up period; two of these were considered diagnostic failures (chronic pancreatitis and pancreatic cancer). Of the remaining 95 patients, 93 were available for the follow-up study. Three diagnostic failures were found (gallbladder stones, kidney stone, thyrotoxicosis). The diagnostic failure rate was accordingly 4.5% (5/110). Half of the patients had unchanged or aggravated symptoms at the follow-up study, independent of treatment. The only predictor of a poor prognosis was abdominal surgery before the diagnosis.

Adult↗

Physical complaints and emotional stress related to routine diagnostic procedures of the fertility investigation.

The aim of this study was to map out the extent of the physical complaints and emotional stress due to diagnostic routines of the infertility work-up. To this end a questionnaire was sent to 96 consecutive couples visiting an infertility clinic of a university hospital. The results indicate that women often have physical complaints as a result of the hysterosalpingography (59%) and the diagnostic laparoscopy (47%) and mostly experience these diagnostic procedures as very stressful. Both the postcoital test and the semen analysis caused a moderate amount of stress. The other diagnostic procedures, including physical examination of both sexes, recording of the basal temperature and taking blood for hormonal determinations, were accompanied by fewer complaints and much less stress. It is concluded that the role of the hysterosalpingography and the diagnostic laparoscopy in the routine infertility work-up needs to be reconsidered in view of the burden they pose to the women involved.

Adult↗

The spectrum of patients strongly influences the usefulness of diagnostic tests for pneumonia.

OBJECTIVE: To study the influence of the spectrum of patients on the usefulness of five clinical cues, "very annoying dyspnoea", "strong lateral chest pain", crackles, C-reactive protein analysis, and erythrocyte sedimentation rate in the diagnosis of pneumonia. DESIGN: Evaluating the diagnostic properties of the cues against radiographic pneumonia at four steps in the diagnostic process, associated with increasing prevalence of pneumonia: 1. in all the 581 patients included, 2. in 402 of these patients who underwent physical chest examination, 3. in 188 patients classified by the doctors as having a lower respiratory tract infection, and 4. in 79 patients referred for radiography by the doctors. SETTING: The municipal emergency clinic in Tromsø, Norway. PARTICIPANTS: 581 adult patients with respiratory tract infection. OUTCOME MEASURES: Sensitivity, specificity, Likelihood Ratio, and Positive predictive value. RESULTS: A tendency of decreasing specificity and Likelihood Ratio with increasing prevalence of pneumonia was demonstrated for all test, except for C-reactive protein analysis. This tendency may be explained either by the emphasis laid on the tests by the doctors when selecting patients for the diagnostic steps, or by an association between the evaluated tests and those emphasized by the doctors. CONCLUSION: As the diagnostic value of symptoms and signs are strongly influenced by selection, caution should be shown when transferring diagnostic values from one clinical setting to another.

Adult↗

Diagnostic quality in hysterosalpingography. Comparison between iodixanol and iotrolan.

PURPOSE: To compare the diagnostic quality and adverse events of the water-soluble, non-ionic, iso-osmolar, dimeric contrast media iodixanol and iotrolan in hysterosalpingography (HSG). MATERIAL AND METHODS: One hundred and twenty patients participated in a double-blind randomized parallel-group phase-III study. Questionnaires and patient interviews were used. Diagnostic quality was assessed using a visual analogue scale and the quality in specific regions was rated using a categorical scale. RESULTS: Overall diagnostic quality was equal for the two groups. There was no statistically significant difference between the two groups in diagnostic quality in the specific regions of interest. No differences between the contrast media were found with regard to adverse events. CONCLUSION: Both contrast media provided images of high diagnostic quality in HSG.

Contrast Media↗

Diagnostic value of ultrasonography in patients with palpable mammographically noncalcified breast tumors.

PURPOSE: To analyze the diagnostic accuracy of mammography, ultrasonography (US), and both methods combined in evaluation of palpable noncalcified breast tumors. MATERIAL AND METHODS: Mammograms and sonograms of 200 patients with palpable noncalcified breast masses were retrospectively analyzed independently by four experienced radiologists in 3 sessions: Mammography or US interpretations in the first two and combined reading in the last session. Nonneoplastic abnormalities and mammographically obvious cancers were excluded. Receiver operating characteristic (ROC) analyses were performed for 115 (60 benign and 55 malignant) tumors and subgroups according to tissue density and tumor size. A single ROC curve for each diagnostic test was obtained by pooling the individual ratings. The area under the ROC curve was used as a measure of diagnostic performance. RESULTS: US revealed significantly higher diagnostic performance than mammography for tumors larger than 2 cm. Combined reading showed significantly higher performance than mammography except for tumors smaller than 2 cm. The performance of all three tests was reduced in dense parenchyma, and significantly so for mammographic and combined interpretation. CONCLUSION: The accuracy of US in patients with palpable mammographically noncalcified and not obviously malignant breast tumors is lower than reported for mixed sample populations. The accuracy of US may be influenced by breast parenchyma density. Combined reading offers the highest diagnostic accuracy.

Breast Neoplasms↗

Diagnostic accuracy of magnetic resonance imaging for detecting posterior ligamentous complex injury associated with thoracic and lumbar fractures.

OBJECT: The posterior ligamentous complex (PLC) in the thoracic and lumbar spine is one of the region's important stabilizers. The precise diagnosis of PLC injury is required to evaluate the instability of the injured spine; however, the accuracy of magnetic resonance (MR) imaging for diagnosing PLC injury has remained unclear. In this study, the authors compared preoperative MR imaging findings with direct intraoperative observation of PLC injury, clarifying the former's diagnostic accuracy regarding detection of PLC injury associated with the thoracic and lumbar fractures. METHODS: Data obtained in 35 patients who sustained thoracic or lumbar injuries were reviewed. There were 17 burst fractures, six flexion-distraction injuries, and 12 fracture dislocations. Each patient underwent MR imaging examination within 3 weeks of injury. Three radiologists independently evaluated sagittal MR images in a blinded fashion. The PLC-related information was retrospectively collected from each operative record. The diagnostic accuracy of MR imaging was analyzed by comparing imaging-documented intraoperative findings. The PLC injuries were detected in 23 patients (65.7%) by direct observation during posterior spinal procedures. The diagnostic accuracy of MR imaging in detecting injury of the supraspinous ligament (SSL) and interspinous ligament (ISL) was 90.5 and 94.3%, respectively. The specificity of T1-weighted MR imaging alone for depicting the SSL was significantly greater than T2-weighted imaging alone (p < 0.05). The overall mean kappa coefficient for MR imaging findings of PLC injury was 0.803, which indicated excellent interobserver reliability; that for ISL (0.915) was significantly greater than that for SSL (0.69) (p < 0.05). CONCLUSIONS: This study clarified a high diagnostic accuracy and interobserver reliability of MR imaging for PLC injury. The precise diagnosis of PLC injury is essential to determine the mechanical instability of the injured thoracic and lumbar spine, especially in differentiating unstable (three-column) burst fractures from the relatively stable (two-column) type. The authors conclude that MR imaging is a powerful diagnostic tool to evaluate PLC injury associated with thoracic and lumbar fractures.

Humans↗