Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “atomic force microscopy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84Linked to original sources

Dynamics of space and polarization charges of ferroelectric thin films measured by atomic force microscopy.

Retention behavior and local hysteresis characteristics in Pb(Zr(0.52)Ti(0.48))O(3) (PZT) thin films on Pt electrodes have been investigated by electrostatic force microscopy (EFM). A sol-gel method is used to synthesize PZT thin films and drying conditions are carefully explored over a wide range of temperature. Decay and retention mechanisms of single-poled and reverse-poled regions of the ferroelectric thin films are explained by space charge redistribution. Trapping behavior of space charges is dependent on the nature of interface between ferroelectric thin films and bottom electrodes. Local measurement of polarization-electric field curves by EFM shows inhomogeneous space charge entrapment.

Journal Article↗

Thermomechanical noise of a free v-shaped cantilever for atomic-force microscopy.

We have calculated the thermal noise of a v-shaped AFM cantilever (Microlever, Type E, Thermomicroscopes) by means of a finite element analysis. The modal shapes of the first 10 eigenmodes are displayed as well as the numerical constants, which are needed for the calibration using the thermal noise method. In the first eigenmode, values for the thermomechanical noise of the z-displacement at 22 degrees C temperature of square root of u2(1) = A/square root of c(cant) and the photodiode signal (normal-force) of S2(1) = A/square root of c(cant) were obtained. The results also indicate a systematic deviation ofthe spectral density of the thermomechanical noise of v-shaped cantilevers as compared to rectangular beam-shaped cantilevers.

Journal Article↗

Imaging cobalt nanoparticles by amplitude modulation atomic force microscopy: comparison between low and high amplitude solutions.

In many situations of interest amplitude modulation AFM is characterized by the coexistence of two solutions with different physical properties. Here, we compare the performance of those solutions in the imaging of cobalt nanoparticles. We show that imaging with the high amplitude solution implies an irreversible deformation of the nanoparticles while repeated imaging with the low solution does not produce noticeable changes in the nanoparticles. Theoretical simulations show that the maximum tip-surface force in the high amplitude solution is about 14nN while in the low amplitude solution is about -4nN. We attribute the differences in the high and low amplitude images to the differences in the exerted forces on the sample.

Journal Article↗

Lift-off patterning of thin Au films on Si surfaces with atomic force microscopy

We studied a new lift-off process of thin Au film on silicon surfaces in nanometer-scale, combining anodic oxidation patterning with AFM, deposition of Au thin film on the patterned substrate and chemical etching processes of the Si oxide underneath the Au film. For Au films of thickness of 2-5 nm, the Au films on the Si oxide patterns were left unbroken and bent down to stick to Si surface after the removal of the oxide by the chemical etching. For an Au film of 1 nm in thickness, it was possible to lift-off the Au film on oxide patterns of the lines and dots in nanometer-scale using Si oxide as a sacrificial mask.

Journal Article↗

Influence of the carbon nanotube probe tilt angle on the effective probe stiffness and image quality in tapping-mode atomic force microscopy.

Previous studies have shown that when using carbon nanotubes (CNTs) as tapping-mode AFM probes, their tilt angle with respect to vertical (denoted phi) must be close to 0 degrees to obtain high-quality images and that very poor images are obtained for phi > 30 degrees . Here we present a quantitative theoretical investigation of the effect of phi on tapping-mode AFM imaging for single-wall and multiwall nanotube (SWNT and MWNT, respectively) probes of diameters 3.4-5.5 nm and aspect ratio 7.5, which have been found ideal for imaging via TEM. Using molecular and classical dynamics, we investigate the effect of phi on CNT probe stiffness (quantified through the maximum gradient of the tip-sample interaction force) and show that it decreases linearly with increasing phi, becoming negligible at around phi approximately 40 degrees , thus confirming the conclusions of previous studies. We find that MWNT probe stiffness is proportional to the number of walls, but that the difference in stiffness between SWNTs and MWNTs also decreases linearly with increasing phi and becomes negligible at around phi approximately 40 degrees . The simulated cross-sectional scans of a sample SWNT using two different values of phi show that the image can be distorted and shifted laterally when phi is large, in some cases giving measured heights appreciably greater than the sample dimensions. We show analytically that the tip-sample forces that occur during imaging can be significantly lower when CNT probes are used instead of conventional probes, even in the absence of buckling, and that they can be further reduced by increasing phi. On the basis of this result, we propose the design of free-standing kinked probes for the characterization of sensitive samples, whereby the probe approaches the sample at a vertical orientation and possesses a tilted section that regulates the tip-sample interaction forces.

Journal Article↗

Characterization of distance-dependent damping in tapping-mode atomic force microscopy force measurements in liquid.

We have used a spectral analysis method to characterize changes in the local damping coefficient for an acoustically driven cantilever as it approaches a hard surface in liquid. We show a significant distance dependence of the damping coefficient (and associated quality factor) that must be accounted for to achieve successful theoretical reproduction of experimental tapping-mode force curves. We model the cantilever dynamics using a forced damped harmonic oscillator model and solve the equation of motion using the method of finite differences. Experiments in solutions of differing viscosities show that bulk viscous damping is not the source of the system dissipation, while simulations of the cantilever dynamics including adhesion hysteresis also eliminate this as the origin of the dissipation. We conclude that frictional dissipation that occurs with the intermittent contact is the likely source of dissipation in the system. Our results identify a semiquantitative means of interpreting tapping-mode force curves on nondeformable surfaces in liquid.

Journal Article↗

Atomic force microscopy studies of mesoscopic membranous bubbles on monolayers derived from SiCl3-terminated carbosilane dendrons on mica.

Monolayers of dendrimers were prepared on mica by spin-coating of the second generation carbosilane dendrons with 9 SiCl(3) periphery groups. AFM images of the films showed the presence of soft yet robust, dome-shaped features with a base diameter of 100-2000 nm. The apparent height of the features, ranging from 10 to 200 nm, rapidly reduced under increasing compression force, eventually to the same value ( approximately 2.5 nm) corresponding to a bilayer of the flattened dendrons. The change in shape of the features in response to the compression force from the AFM tip was fully reversible, indicating that the features were robust. The contrast of the features in the tapping mode AFM (TMAFM) phase images flipped at a setpoint ratio of approximately 0.55. In contrast to the reported amplitude vs displacement (A/z) curves for compliant materials, A/z curves of the features showed that the reduction of amplitude was larger than the tip displacement as if the cantilever tip were repelled by the soft features. This result cautions the use of amplitude/phase vs displacement (APD) curves for interpreting TMAFM images and for optimizing conditions for TMAFM imaging of very soft and "sticky" surfaces. On the basis of the AFM studies, we believe that the dome-shaped features are membranous air bubbles. The membranes of the bubbles were probably composed of a bilayer of the dendron molecules bound through the peripheral silanol groups. The bilayer could be formed by self-assembly of the molecules on top of the air bubbles entrapped at the monolayer/solution interface during spin-coating.

Journal Article↗

Direct imaging of meniscus formation in atomic force microscopy using environmental scanning electron microscopy.

Environmental scanning electron microscopy was used to image meniscus formation between an AFM tip and a surface. At high relative humidity, 70%-99%, the meniscus formed is 100 to 1200 nm in height, orders of magnitude larger than predicted by the Kelvin equation using spherical geometry. The height of the meniscus also demonstrates hysteresis associated with increasing or decreasing relative humidity.

Letter↗

Atomic force microscopy of uncoated plasmid DNA: nanometer resolution with only nanogram amounts of sample.

Reproducible, high-contrast, nanometer-resolution AFM images of uncoated plasmid DNA can be obtained with nanogram quantities of DNA with the help of two advances in sample preparation: (1) Heating a DNA solution at 35 degrees C for 10 to 20 minutes before deposition on mica helps separate and spread the DNA, and (2) Using 5 microliter drops of the heated DNA solution in the concentration range of 2 to 10 nanogram/microliter in contact with a specially prepared mica surface for 5 to 10 minutes gives optimal coverage with only nanograms of DNA.

Aluminum Silicates↗