Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Separation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84Linked to original sources

Chromatographic enrichment and enantiomer separation of axially chiral polybrominated biphenyls in a technical mixture.

The separation properties of different chromatographic methods regarding the enantioselective separation of axially chiral (atropisomeric) polybrominated biphenyls (PBB) were studied. For this purpose, the technical hexabromobiphenyl product Firemaster BP-6 was characterised by gas-chromatography coupled to electron capture detection (GC/ECD) and electron-capture negative ion mass spectrometry (GC/ECNI-MS) as well as by liquid chromatographic fractionating on active carbon and celite. Twelve individual PBBs including potential atropisomeric PBBs were isolated from Firemaster BP-6 by reversed-phase high-performance liquid chromatography (HPLC) on three serially coupled octadecylsilane columns. Six of the 12 isolated PBBs (three tri-ortho and di-ortho substituted PBBs, respectively) were separated into atropisomers on a HPLC column containing permethylated beta-cyclodextrin on silica. Moreover, the temperature dependency of the enantiomer separations is discussed. Gas chromatographic enantiomer separation of PBBs is a very demanding task due to high elution temperatures. However, the atropisomers of one tri-ortho substituted PBB congener (PBB 149) could be resolved on a column coated with randomly modified heptakis(6-O-tert.-butyldimethylsilyl-2,3-di-O-methyl)-beta-cyclodextrin in OV 1701.

Chromatography, Gas↗

Separation of aromatic aminophosphonic acid enantiomers by capillary electrophoresis with the application of cyclodextrins.

The detailed studies concerning capillary electrophoresis separation of aminophosphonic acid enantiomers with various commercially available cyclodextrins are presented. The obtained results show that the separation of these stereoisomers is dependent on pH of background electrolyte, concentration of cyclodextrin as well as on the type of applied chiral selector. The separation mechanism is based on the co-operative effect of hydrogen bond type interactions enhanced by hydrophobic forces and sterical constrains between aminophosphonate and cyclodextrin. With application of elaborated method, enantiomeric baseline or partial separation of 18 alpha-aminophosphonic acids was achieved. This separation can be successfully used for routine aminophosphonic acids enantiopurity determination.

Cyclodextrins↗

Optimisation by experimental design of a capillary electrophoretic method for the separation of several inhibitors of angiotensin-converting enzyme using alkylsulphonates.

A statistical experimental design was used to optimise a capillary electrophoretic separation method for eight inhibitors of the angiotensin-converting enzyme: enalapril, lisinopril, quinapril, fosinopril, perindopril, ramipril, benazepril, and cilazapril. Because a free solution capillary electrophoresis system did not achieve a complete separation of these eight compounds in one run, the usefulness of alkylsulphonates as ion-pairing agents was investigated. After preliminary investigations to determine the experimental domain and the most important factors, a three-level full-factorial design was applied to study the impact of the pH and the molarity of the ion-pairing agent on the separation. Improved separations were obtained suggesting a favourable effect of ion-pairing interactions between analytes and the additive; however, it remained impossible to separate them all in one run. A combination of two systems was still necessary for the selective identification of these structurally-related substances.

Angiotensin-Converting Enzyme Inhibitors↗

Effect of feed zone width on product purity in preparative-scale, continuous free-flow isoelectric focusing separation of enantiomers.

The effects of the increased width of the sample feed stream upon the purity of the collected fractions were examined in the continuous free-flow isoelectric focusing separation of the enantiomers of dansyl-tryptophan. Compared to the reference separation obtained with a narrow feed stream introduced through the central sample feed port of the continuous free-flow isoelectric focusing separation unit, the final pH gradient, the position of the enantiomer band centroids and the values of the cumulative product recoveries and cumulative product purities remained essentially identical as the width of the feed band of the racemic sample dissolved in the carrier ampholyte was increased up to the full width of the separation chamber suggesting that the current, limiting practice of narrow, central feed bands can be safely abandoned and dilute feedstock solutions can be utilized in preparative-scale isoelectric focusing enantiomer separations.

Hydrogen-Ion Concentration↗

Comparison of standard capillary and chip separations of sodium dodecylsulfate-protein complexes.

Conditions for converting a set of five standard proteins to electrochemically active sodium dodecylsulfate (SDS) complexes were worked out with the aim of using such complexes for conductivity detection with a a chip electrophoresis system. The results obtained were compared with standard capillary electrophoresis (37 cm (effective length 30 cm) x 75 microm I.D. capillary, 10 kV, negative polarity at the inlet). The chip separations were run at 500 V per chip (100 V/cm) as compared to the standard capillary arrangement, which was run at 266.6 V/cm. For the capillary set-up the protein complexes were prepared in aqueous solution (Milli-Q water) made 10 mM with respect to SDS. If the SDS concentration was increased to 50 mM, the separation in the capillary was incomplete. On the other hand with the chip system both approaches yielded acceptable results. The chip separations were slightly (but not distinctly) shorter and offered better separations than the standard set-up. The concentration of the surfactant used for the preparation the complexes results in alternations of the elution sequence, which is preserved if the chip separation is used instead of the capillary set-up. Apparently the full capacity of protein-SDS binding is not exploited for the preparation of the adducts.

Electrophoresis, Capillary↗

Preparative-scale isoelectric trapping enantiomer separations.

The new Gradiflow BF200 IET unit, developed for isoelectric trapping protein separations has been modified and used to carry out preparative-scale enantiomer separations. Hydroxypropyl beta-cyclodextrin was used as the chiral resolving agent to induce an isoelectric point difference between the enantiomers. Three isoelectric membranes with isoelectric points below, in between and above the isoelectric points of the complexed enantiomers were used to trap the separated enantiomers in the anodic and cathodic separation compartments of the Gradiflow BF200 IET apparatus, respectively. The production rates were about 15 times higher than those previously obtained with another isoelectric trapping device and about 30% higher than those obtained in a continuous free-flow electrophoretic device operated in the isoelectric focusing mode. The remarkable separation speed observed in the modified Gradiflow BF200 IET unit is attributed to the favorable interplay of the short electrophoretic transfer distance, the high electric field strength and the large effective surface areas of the isoelectric membranes.

Isoelectric Focusing↗

Creation and characteristics of phosphatidylcholine stationary phases for the chromatographic separation of inorganic anions.

New stationary phases for chromatographic separation of anions, obtained by loading liposomes made from dimyristolyphosphatidylcholine (DMPC) onto reversed-phase packed columns (C18 and C30) are reported. Mono- and divalent anions were used as model analyte ions and retention data for these species were obtained using the DMPC stationary phases and used to elucidate the separation mechanisms involved in this chromatographic system. The DMPC stationary phases can separate anions by either a solvation-dependent mechanism or an electrostatic ion-exchange mechanism, depending upon the relative magnitudes of the negative electrostatic potential (Psi(-)) of the phosphate moiety (P-) and the positive electrostatic potential (Psi(+)) of the quaternary ammonium groups (N+) on the headgroup of DMPC. If Psi(+) > Psi(-), such as in case where Psi(-) has been reduced either by binding of eluent cations (e.g., H+ or divalent cations) onto the P- group of DMPC or by steric screening when a C30 reversed-phase material was used to support the DMPC, then the overall electrostatic surface potential (and hence also the effective anion-exchange capacity) was generally large and the anions were separated on the basis of an electrostatic mechanism. However, if Psi(+) was similar to Psi(-), such as in the case of using a C18 reversed-phase support and monovalent cations as eluent cations, then the overall electrostatic surface potential and the effective anion-exchange capacity were very small and the analyte anions were separated on the basis of a solvation-dependent mechanism. The DMPC stationary phases were found to be suitable for the direct determination of iodide and thiocyanate in highly saline water samples, such as seawater samples.

Anions↗

Miniaturized sample preparation combined with liquid phase separations.

Miniaturized sample preparation methods designed as the sample pretreatment for liquid phase separations, such as liquid chromatography, capillary electrophoresis and capillary electrochromatography, have been reviewed especially for the on-line coupling of the sample preparation process and the separation process. The development of the desorption interfaces for the effective combining of the sample preparation and subsequent liquid phase separations is briefly described along with the applications of the combined analytical systems to the analysis of complex sample mixtures such as biological and environmental matrices. Novel use of fine polymeric filaments as the extraction medium for microscale liquid phase separation methods are investigated and a comparison is made with other sample preparation techniques. Polymer coating onto the fibrous material is also introduced to further develop microscale sample preparation methods with improved extraction performance. Several other microscale sample preparation methods having a potential compatibility to the liquid phase separations are also described for future applications of these techniques.

Chromatography, Liquid↗

Mixed-matrix membrane adsorbers for protein separation.

The separation of two similarly sized proteins, bovine serum albumin (BSA) and bovine hemoglobin (Hb) was carried out using a new type of ion-exchange mixed-matrix adsorber membranes. The adsorber membranes were prepared by incorporation of various types of Lewatit ion-exchange resins into an ethylene-vinyl alcohol copolymer porous structure. The obtained heterogeneous matrices, composed of solid particles surrounded by the polymeric film, display high static and dynamic protein adsorption capacities. The effect of operational parameters such as filtration flow-rate, pH, and ionic strength on the protein separation performances was investigated for cation- as well as anion-exchange adsorber membranes. An average separation factor was calculated by numerical integration of the protein concentration in the permeate curve during the filtration run. High average separation factor values were obtained for BSA-Hb separation at physiological ionic strength with a filtration flow-rate up to 20 1/h per m2, until the protein breakthrough point at 10% of the feed concentration.

Adsorption↗

Comparison of the performance characteristics of poly(dimethylsiloxane) and Pyrex microchip electrophoresis devices for peptide separations.

A comparative study of electrophoretic separations of fluorescently labeled peptides and amino acids on poly(dimethylsiloxane) (PDMS) and Pyrex microchips is presented. The separation parameters for each microchip substrate were compared, including electroosmotic flow, plate numbers, resolution, and limits of detection. The effect of buffer composition on the separation was also investigated. Acceptable separations were obtained for most peptides with both substrates; however, PDMS chips exhibited much lower separation efficiencies and longer analysis times.

Amino Acids↗

Robustness testing of chiral separations by capillary electrophoresis using highly-sulfated cyclodextrins.

The robustness of a generic method for chiral separation in capillary electrophoresis using highly-sulfated cyclodextrins in a low pH phosphate buffer and the "short-end injection technique" was studied. In this study, we focused on the robustness of the separations and not of the quantitative analysis of the enantiomers. The robustness was evaluated for the enantiomeric separation of a basic (propranolol), a neutral (praziquantel) and an acidic (warfarin) compound. The influence of eight factors which were believed to affect significantly the separations was studied using a 11-factor, 12-experiment Plackett-design. Statistical interpretation of the factor effects on different analytical responses (selectivity and resolution) was performed. The separations of the three compounds could be considered as rather robust as the factor effects were generally not significant (alpha = 0.05) and small.

Cyclodextrins↗

Evaluation of the two-dimensional reversed-phase-reversed-phase separations of low-molecular mass polystyrenes.

The resolving power of four reversed-phase-reversed-phase two-dimensional (2D) chromatographic systems was evaluated using information theory (IT) and a geometric approach to factor analysis. The first separation dimension employed a C18 column, while the second separation dimension employed a carbon clad zirconia column. Mobile phases in each dimension were either methanol or acetonitrile. The sample matrix that was employed in this study contained a mixture of 58 components, comprised of stereoisomers and structural isomers of a systematic variation in molecular weight. Each of the components were oligostyrenes, with between two and five configurational repeating units having either n-butyl, sec-butyl or tert-butyl end groups. In the two-dimensional systems employed in this study, between 46 and 49 of the 58 components could be separated, depending on the mobile phase combinations--with apparent resolution that could not possibly be achieved in a single one-dimensional separation. The results from this study indicate that in order to fully evaluate the resolving power of a 2D system multiple methods of analysis that evaluate the separation potential are most appropriate. This becomes increasingly important when the sample contains components that are very closely related and the retention of solutes displays a high degree of solute crowding.

Molecular Weight↗

Enantiomeric separation of propranolol and selected metabolites by using capillary electrophoresis with hydroxypropyl-beta-cyclodextrin as chiral selector.

A capillary electrophoresis (CE) investigation of the enantiomeric separation of propranolol and some of its metabolites using CE was undertaken. Resolution of the enantiomers was achieved using hydroxypropyl-beta-cyclodextrin (HP-beta-CD) as the chiral selector. Parameters found to influence separation include cyclodextrin concentration, potential, pH and organic solvent/additive. It was observed that 17 mM HP-beta-CD gave optimum separation over the concentration range used in this study, however different racemates appear to have best resolution at different CD concentration. The potential does not have a great effect on enantiomer resolution, but appears to cause relative metabolite migration times to alter such that separation is affected. Carrier pH affects both migration time, and enantiomer resolution and metabolite separation. Above pH 5 inferior results are obtained. This is the first report of enantiomeric resolution of propranolol metabolites using CE.

Carbohydrate Sequence↗

On-line analysis by capillary separations interfaced to an ion trap storage/reflectron time-of-flight mass spectrometer.

The interface of high-resolution capillary separation methods to time-of-flight mass spectrometry (TOF-MS) has generated considerable interest since TOF can provide the rapid and sensitive detection required by high resolution separations. In recent years, our laboratory has developed a variety of high-resolution capillary separation methods interfaced to TOF-MS via an ion trap storage/reflectron time-of-flight (IT/reTOF) instrument. Using this hybrid configuration, detection of fast separations at very low detection levels has been successfully performed for on-line separations of peptides and protein digests using electrospray ionization. In this report, we review the current status in our laboratory of interfacing high-performance liquid chromatography, capillary electrophoresis, and capillary electrochromatography to an IT/reTOF-MS instrument and various applications that have been developed involving this technology.

Chromatography, High Pressure Liquid↗

Cyclodextrin aided separation of peptides and proteins by capillary zone electrophoresis.

Carboxymethylated-beta-cyclodextrin (CMBCD) in the electrophoretic medium (aqueous 50 mM sodium phosphate, pH 2.5) enhanced the separation using raw fused-silica capillaries in CZE of the four standard proteins: alpha-chymotrypsinogen A, cytochrome c, lysozyme and ribonuclease A. Furthermore, with 20 mM CMBCD in the electrophoretic medium, the cis-trans isomers of angiotensin could be separated at room temperature, whereas the separation of the conformers required subambient temperatures as low as -20 degrees C without CMBCD in the electrophoretic medium [50 mM sodium phosphate (pH 2.5), containing 10% (v/v) methanol]. Addition of heptakis(2,6-di-O-methyl)-beta-cyclodextrin (DMBCD) had no effect on the separation of the above proteins and peptides. The results suggest that in microcolumn separation techniques, certain cyclodextrin additives can be useful selectivity enhancers.

Amino Acid Sequence↗

Development of a downstream process for the isolation and separation of monoclonal immunoglobulin A monomers, dimers and polymers from cell culture supernatant.

The isolation and separation of the molecular variants of monoclonal IgA from cell culture supernatants is possible using several filtration and ion-exchange chromatography steps, followed by size-exclusion chromatography for the actual separation of the molecular variants. The latter step is especially time consuming and laborious. This report presents possible improvements of the procedure. Use of the displacement rather than the elution mode may render the ion-exchange step more productive (higher product concentrations and space-time yield). For the final separation of the molecular variants, hydroxyapatite (HA) elution chromatography can serve as an alternative to size-exclusion chromatography. By using an optimized, complex phosphate gradient, the IgA dimers can be separated quantitatively from the monomers and higher oligomers. It may in individual cases be necessary to use a size-exclusion polishing step to reach the required final degree of purity, however, the amount of material to be processed is reduced to such an extend by the HA-step, that the overall process is still more productive. Buffer pH and flow-rate as well as the stationary phase material used were additional factors considered during the optimization of the HA elution chromatography. HA-displacement chromatography resulted only in a concentration of the overall IgA fraction, but not in a separation of the molecular forms.

Animals↗

Method for the separation of the unconjugates and conjugates of chenodeoxycholic acid and deoxycholic acid by two-dimensional reversed-phase thin layer chromatography with methyl beta-cyclodextrin.

A simple and efficient method for the separation of individual unconjugated bile acids and their glycine- and taurine-amidated, 3-sulfated, 3-glucosylated and 3-glucuronidated conjugates is described. The method involves the use of a two-dimensional (2D) reversed-phase (RP) high-performance thin-layer chromatographic (HPTLC) technique with methyl beta-cyclodextrin (Me-beta-CD). Five major unconjugated bile acids, chenodeoxycholic acid (CDCA), deoxycholic acid (DCA), ursodeoxycholic acid and lithocholic acid, and their conjugates were examined as the solutes. A high degree of separation of individual bile acids in each homologous series was achieved on a RP-HPTLC plate by developing with aqueous methanol in the first dimension and the same solvent system containing Me-beta-CD in the second dimension. In particular, all of the six 'difficult-to-separate' pairs, unconjugated CDCA and DCA and their conjugated forms with glycine, taurine, sulfuric acid, D-glucose and D-glucuronic acid, were effectively resolved by adding Me-beta-CD in the aqueous mobile phases with the formers having larger mobilities than the latter. The application of this 2D inclusion RP-HPLC method to the separation of glycine-conjugated bile acids in human bile is also described. The present method would be useful for separating and characterizing these bile acids present in biological materials.

Bile↗

Nonaqueous capillary electrophoresis chiral separations with quaternary ammonium beta-cyclodextrin.

Chiral separation of nonsteroidal anti-inflammatory drugs (profens), 1,1'-binaphthyl-2,2'-diyl-hydrogen phosphate, N-[1-(1-naphthyl)ethyl]phthalamic acid, and derivatized amino acids by a cationic cyclodextrin, quaternary ammonium beta-cyclodextrin (QA-beta-CD), was investigated by capillary electrophoresis (CE) in both aqueous and nonaqueous media. Several profens and amino acids could only be separated by QA-beta-CD in pure formamide system. No chiral separation of the profens was achieved in the following solvents: N-methylformamide, methanol, dimethyl sulfoxide, and water; however, chiral separations of most of the amino acids were obtained in all of these solvents. The effects of other experimental parameters such as the CD concentration and apparent pH (pH*) were also investigated. The first application of nonaqueous CE chiral separation of ketoprofen in a commercially available sample, Actron, was also examined. In addition, the reversal of electroosmotic flow by QA-beta-CD was observed in water, formamide, N-methylformamide, methanol, and dimethyl sulfoxide media.

Anti-Inflammatory Agents, Non-Steroidal↗