Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Rotation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84Linked to original sources

The instantaneous center of rotation during human jaw opening and its significance in interpreting the functional meaning of condylar translation.

Mandibular condyles translate back and forth during mouth closing and opening in primates and most other mammals. To account for the functional significance of this phenomenon, several hypotheses have been proposed. The sarcomere-length hypothesis holds that condylar translation provides a mechanical advantage by minimizing sarcomere-length changes in the masseter-medial pterygoid complex throughout a wide range of jaw openings. As the hypothesis is inherently associated with the locations of the instantaneous centers of rotation (ICRs) of the mandible, a more accurate determination of this variable would help test this hypothesis. This study investigated ICRs in the sagittal plane during human symmetrical mandibular opening based on a recently developed analytical method. The results confirmed that, with inter- and intraindividual variation, the natural opening was a simultaneous rotational and translational motion. In addition, the ICR was found to lie closer to the condyle during the first 10 degrees than during the rest of the rotation. This suggests that for the condyles the rotational component is somewhat more significant at the early phase than at the late phase of the opening stroke. For the whole range of the natural opening, the grossly approximated centers of rotation (CRs) scattered below the palpable lateral condylar poles in the superior half of the ramus. This study supports neither the ICR path determined by Grant ([1973], J. Biomech. 6:109-113) nor the conclusions reached by recording manually operated jaw movements in human cadavers (Rees [1954] Br. Dent. J. 6:125-133). Moss's suggestion ([1960] Disorders of the Temporomandibular Joint (Philadelphia: W.B. Saunders), pp. 73-88) that the center of rotation lies at the lingula is also not confirmed. Although the new data cannot reject the sarcomere-length hypothesis, they do not strongly support it either. Another hypothesis is proposed in this study as plausible. With this hypothesis, translation is regarded as an adaptation to the use of the inferior head of the lateral pterygoid as a jaw depressor in noncarnivorous mammals. Potential functional advantages of this portion of the muscle are also discussed.

Biomechanical Phenomena↗

Coronary blood flow velocities during rotational atherectomy.

This study was designed to evaluate the alterations in doppler derived coronary blood flow velocities and flow reserve following rotational ablation. Changes in doppler derived coronary blood flow velocity variables have been valuable in assessing the physiological outcome following coronary balloon angioplasty. Rotational ablation's mechanism of plaque removal could alter distal vascular bed characteristics, and, as a result, intracoronary blood flow velocities and the coronary flow reserve. A 12-MHz doppler guidewire recorded intracoronary phasic velocities and coronary flow reserve (as assessed by the hyperemic response to adenosine [12-18 mcg intracoronary]) in 28 patients, before and after rotational ablation of 30 lesions. Adjunctive balloon angioplasty was performed in 27 of 28 patients (96%). Rotational ablation and adjunctive balloon angioplasty successfully reduced the lesion diameter (87 +/- 9% to 14 +/- 11%; P < 0.001). A significant increase in the mean distal average peak velocity (25 +/- 13 cm/sec, before; 47 +/- 22 cm/sec, after; P < 0.001), and decrease in the proximal to distal average peak velocity ratio, (2.1 +/- 1.3; to 1.2 +/- 0.4; P = 0.002) was recorded. The mean distal diastolic to systolic velocity ratio (before, 1.4 +/- 0.7; after, 1.6 +/- 0.8; P = 0.44) and the coronary flow reserve (before, 1.6 +/- 0.6; after, 1.5 +/- 0.5; P = 0.34) did not increase despite increases in distal velocities, following successful intervention. Doppler derived distal coronary blood flow velocities increased following rotational ablation and adjunctive balloon angioplasty, with resolution of transstenotic velocity gradient. Changes in distal phasic velocity pattern and coronary flow reserve, immediately after the intervention, were not useful in the assessment of the functional outcome and may be related to abnormalities in distal vascular bed vasoreactivity produced by rotational ablation.

Aged↗

Stereodynamics of bond rotation in tertiary aromatic amides.

The degree to which the rotations about the C-N and Ar-CO bonds of aromatic amides occur in a concerted manner was investigated by a variety of NMR and kinetic techniques. Otherwise complex kinetic analyses were simplified by exploiting symmetry and asymmetry in the N-substituents of amides. In 2-unsubstituted 1-naphthamides bearing branched N-substituents, most conformational changes about the amide group were by correlated rotation, though uncorrelated Ar-CO rotation also occurred to some extent. In 2-substituted 1-naphthamides, correlated rotation accounted for all of the Ar-CO rotations, though a significant amount of uncorrelated C-N rotation also occurred. Naphthamides bearing branched N-substituents thus turn out to be efficient molecular gears: Compound 12 showed almost no gear slippage.

Journal Article↗

The effect of supine rotation on left ventricular dimensions in man: a study using radio-opaque epicardial markers.

It has been reported that patient rotation into the left lateral decubitus position (30 degrees rao) produces significant changes in the regression equations used for left ventricular volume determination and that normal values for echocardiographic left ventricular dimensions obtained from supine patients differ from those obtained after rotation. The purpose of this study was to establish whether patient rotation is associated with changes in left ventricular size and systolic function. The distances between left ventricular epicardial markers attached at the time of cardiac surgery were measured using biplane cineradiography in 14 patients in order to determine left ventricular dimensions before and after rotation. Supine epicardial left ventricular dimensions were not significantly different from those obtained with the patient rotated 30 degrees rao. These results suggest that reported changes in invasive and noninvasive measurements of left ventricular function associated with patient rotation are not primarily due to changes in left ventricular size.

Adult↗

High-speed rotational angioplasty-induced echo contrast in vivo and in vitro optical analysis.

High-speed rotational angioplasty is being evaluated as an alternative interventional device for the endovascular treatment of chronic coronary occlusions. It has been postulated that this type of angioplasty device may produce particulate debris or cavitations that induce myocardial ischemia. To determine the clinical presence of myocardial ischemia during rotational angioplasty, echocardiographic monitoring for wall motion abnormalities was performed in 9 patients undergoing rotational atheroablation using the Auth Rotablator for 10-sec intervals at 150,000 and 170,000 rpm. No wall motion abnormalities were detected in 5 patients evaluated with transesophageal echocardiography or in 4 patients monitored transthoracically, although AV block developed in one patient. Video intensitometry of the myocardial contrast effect for rotation times ranging from 3 to 20 sec found transient contrast enhancement of the myocardium supplied by the treated vessel. Intensity varied over time with half-time decay between 5.6 and 40 sec, indicating the likelihood of microcavitation. An in vitro model was constructed to measure the cavitation potential of the Auth Rotablator. A burr of 1.25 mm diameter rotating at 160,000 rpm achieves a velocity in excess of the 14.7 m/sec critical cavitation velocity. Testing the device in fresh human blood and distilled water produced microcavitations responsible for the enhanced echo effect, with the intensity and longevity of cavitation more pronounced in blood and proportional to the rotation time and speed. The mean size of the microcavitation bubbles in water was 90 +/- 33 (52-145) microns measured from photographs taken with a copper vapour laser emitting light pulses of 50 nsec duration as light source. The mean velocity of bubbles was found to be 0.62 +/- 0.30 ranging from 0.23 to 1.04 m/sec. It was measured via the motion of the bubbles during 5 laser pulses within 800 nsec. Clearly, microcavitations are associated with enhanced myocardial echo contrast effect.

Angioplasty, Balloon, Coronary↗

Randomized study of the safety and clinical utility of rotational vs. standard coronary angiography using a flat-panel detector.

The purpose of this study was to test the hypothesis that rotational angiography improves patient safety while maintaining diagnostic accuracy for patients undergoing coronary angiography. Despite advances in angiographic technique, patients remain at risk for complications of coronary angiography, including contrast-induced nephropathy and radiation exposure. Technology has been developed to perform coronary angiography with active rotation of the imaging system that may reduce the quantity of contrast and radiation to which the patient is exposed. Fifty patients undergoing diagnostic cardiac catheterization were randomized to either standard vs. rotational angiography of the coronary arteries using a prespecified protocol with a flat-panel single-plane imaging system. We measured the quantity of radiographic contrast utilized and radiation exposure. Using an intention-to-treat analysis, there was a 40% reduction (24 +/- 5 vs. 40 +/- 10 ml; P < 0.0001) in contrast utilization in the rotational group compared to the standard group. Neither radiation exposure (35 +/- 14 vs. 30 +/- 20 Gycm(2); P = 0.35), fluoroscopic time (44 +/- 33 vs. 44 +/- 40 sec; P = 0.99), nor procedure time (249 +/- 137 vs. 214 +/- 79 sec; P = 0.26) differed, although significant intraoperator variability was noted for both standard and rotational angiography. The radiation exposure using this flat-panel system is significantly lower than prior reports that used an image intensifier system. Rotational coronary angiography has the potential to improve patient safety by markedly reducing radiographic contrast exposure while maintaining comparable diagnostic accuracy, radiation exposure, and procedure time compared to standard coronary angiography.

Adolescent↗

Sirolimus-eluting stents and calcified coronary lesions: clinical outcomes of patients treated with and without rotational atherectomy.

This study examined the outcomes of patients who underwent sirolimus-eluting stent (SES) implantation for the treatment of heavily calcified coronary lesions (HCCL) with and without the use of rotational atherectomy (rotablator). We investigated 150 consecutive patients with angiographic evidence of HCCL who underwent SES implantation. Sixty-nine patients underwent SES implantation without the need of rotablator (SES), and 81 patients required rotational atherectomy to modify the plaque and facilitate the delivery of the stent (SES + rotational atherectomy). Clinical success was equivalent in both groups (>98%) and there were no in-hospital outcome differences. At 6 months, the target lesion revascularization rate was 4.9% in SES vs. 4.2% in SES + rotational atherectomy groups, respectively (P = NS). Mortality at 6 months was 7.9% in the SES group vs. 6.8% in the SES + rotational atherectomy group (P = NS). SES performs well in patients with complex HCCL, with a relative low event rate. Lesions requiring rotational atherectomy to facilitate dilation and stenting had similar outcomes after SES implantation to those that could be stented without the need for rotablator.

Aged↗

Gas-phase detection of HSOH: synthesis by flash vacuum pyrolysis of di-tert-butyl sulfoxide and rotational-torsional spectrum.

Gas-phase oxadisulfane (HSOH), the missing link between the well-known molecules hydrogen peroxide (HOOH) and disulfane (HSSH), was synthesized by flash vacuum pyrolysis of di-tert-butyl sulfoxide. Using mass spectrometry, the pyrolysis conditions have been optimized towards formation of HSOH. Microwave spectroscopic investigation of the pyrolysis products allowed-assisted by high-level quantum-chemical calculations--the first measurement of the rotational-torsional spectrum of HSOH. In total, we have measured approximately 600 lines of the rotational-torsional spectrum in the frequency range from 64 GHz to 1.9 THz and assigned some 470 of these to the rotational-torsional spectrum of HSOH in its ground torsional state. Some 120 out of the 600 lines arise from the isotopomer H(34)SOH. The HSOH molecule displays strong c-type and somewhat weaker b-type transitions, indicating a nonplanar skew chain structure, similar to the analogous molecules HOOH and HSSH. The rotational constants (MHz) of the main isotopomer (A=202 069, B=15 282, C=14 840), determined by applying a least-squares analysis to the presently available data set, are in excellent agreement with those predicted by quantum-chemical calculations (A=202 136, B=15 279, C=14 840). Our theoretical treatment also derived the following barrier heights against internal rotation in HSOH (when in the cis and trans configurations) to be V(cis) approximately equal to 2216 cm(-1) and V(trans) approximately equal to 1579 cm(-1). The internal rotational motion results in detectable torsional splittings that are dependent on the angular momentum quantum numbers J and K(a).

Journal Article↗

Protocols for the analysis of theoretical optical rotations.

The availability of sophisticated quantum mechanical methods for predicting molecular optical rotations has revolutionized the determination of molecular stereochemistry. However, the objectives and approaches used for the applications of optical rotation vary from one laboratory to the other. With the number of applications of optical rotation increasing at an unprecedented rate, it is considered necessary to discuss the protocols for the general use of optical rotations predicted with quantum mechanical methods. A summary of the quantum mechanical methods for predicting optical rotations and protocols for the use of predicted optical rotations are presented in this article.

Journal Article↗

A prospective approach to correct for inter-image head rotation in fMRI.

Global head motion occurring between successive image acquisitions during a functional MRI time series can corrupt the signal of physiologic brain activation, potentially invalidating interpretation of the final activation map from that particular fMRI time series. By approximating the head as a rigid body, multiaxial global head motion can be decomposed into orthogonal linear and rotational components. This paper describes a method using orbital navigator echoes to provide prospective correction for both through-plane and in-plane inter-image head rotation in functional MRI. The dynamic detection and correction of rotation can be performed in <100 ms. Phantom experiments demonstrate accurate correction of rotational motion over a range of +/-0.36 degrees to +/-12 degrees. Imaging studies in volunteers document the feasibility of real-time prospective correction of rotational motion in vivo. Using a modified receiver operating characteristic method, motion-corrected functional MRI sensorimotor studies incorporating deliberate head rotations are shown to be superior to functional MRI time series acquired under similar conditions but without motion correction.

Artifacts↗

The restoration of electron micrographs blurred by drift and rotation.

We have investigated the restoration of electron micrographs exhibiting blurring due to drift and rotation. Blurring due to drift arises in micrographs taken of a specimen which is moving relative to the image plane. A related problem is that of rotational blurring which arises in micrographs of thin sections of helical particles viewed in cross section. The twist of the particle within the finite thickness of the section causes the image to appear rotationally blurred about the helical axis. Restoration algorithms were evaluated by applying them to the restoration of blurred model images degraded by additive Gaussian noise. Model images were also used to investigate how an incorrect estimate of the point spread function describing the blur would effect the restoration. Images were, if necessary, geometrically transformed to a space in which the point spread function of the blur can be considered as linear and space invariant as, under these conditions, the restoration algorithms are greatly simplified. In the case of the rotationally blurred images this procedure was accomplished by transforming the image to polar coordinates. The restoration techniques were successfully applied to blurred micrographs of bacteriophage T4 and crystals of catalase. The quality of the restoration was judged by comparisons of the restored images to undegraded images. Application to micrographs of rotationally blurred cross sections of helical macrofibers of sickle hemoglobin resulted in a reduction in the amount of rotational blurring.

Algorithms↗

Sex differences in mental rotations: an effect of time limits?

It has been argued that the male performance advantage on the Mental Rotations Test, a measure of three-dimensional rotational ability, reflects a slower problem-solving strategy in females. A recent study of a high-ability sample suggested that sex differences do not reach significance when the test is administered without time limits (Goldstein, Haldane, & Mitchell, 1990). To further explore the effects of time limits, unspeeded versions of the Mental Rotations Test and a vocabulary test were administered to 88 males and 94 females, who represented a less restricted range of ability levels. Males obtained significantly higher scores than females on the Mental Rotations Test (p = .0001), despite comparable performance for the two groups on the vocabulary test. In addition, distributions of Mental Rotations scores were significantly different, with greater proportions of men at the high and women at the low ends. Thus, a difference in speed of problem solving strategy is not a sufficient explanation of the sex difference on the Mental Rotations Test.

Adolescent↗

Double-quantum excitation in the NMR of spinning solids by pulse-assisted rotational resonance.

We describe a new technique for double-quantum excitation in magic-angle-spinning NMR of powdered solids. The technique is designed to efficiently excite double-quantum coherence in the vicinity of a rotational resonance condition. The offset from rotational resonance allows the double-quantum filtered signals to be observed with high resolution and sensitivity. The method uses rotational excitation of zero-quantum coherence, assisted by radiofrequency pulse cycles. The zero-quantum coherence is converted into double-quantum coherence by a frequency-selective inversion sequence. Experiments on [(13)C(2), (15)N]-glycine demonstrate a double-quantum filtering efficiency of approximately 41% at a sample rotation frequency of 8.300 kHz, which is 1.600 kHz away from the n = 1 rotational resonance. We achieve 32% double-quantum filtering efficiency at a spinning frequency of 9.250 kHz, which is 2.550 kHz away from rotational resonance.

Journal Article↗

Rotational Spectrum of Sarin.

As part of an effort to examine the possibility of using molecular-beam Fourier-transform microwave spectroscopy to unambiguously detect and monitor chemical warfare agents, we report the first observation and assignment of the rotational spectrum of the nerve agent Sarin (GB) (Methylphosphonofluoridic acid 1-methyl-ethyl ester, CAS #107-44-8) at frequencies between 10 and 22 GHz. Only one of the two low-energy conformers of this organophosphorus compound (C(4)H(10)FO(2)P) was observed in the rotationally cold (T(rot)<2 K) molecular beam. The experimental asymmetric-rotor ground-state rotational constants of this conformer are A=2874.0710(9) MHz, B=1168.5776(4) MHz, C=1056.3363(4) MHz (Type A standard uncertainties are given, i.e., 1sigma), as obtained from a least-squares analysis of 74 a-, b-, and c-type rotational transitions. Several of the transitions are split into doublets due to the internal rotation of the methyl group attached to the phosphorus. The three-fold-symmetry barrier to internal rotation estimated from these splittings is 677.0(4) cm(-1). Ab initio electronic structure calculations using Hartree-Fock, density functional, and Moller-Plesset perturbation theories have also been made. The structure of the lowest-energy conformer determined from a structural optimization at the MP2/6-311G(**) level of theory is consistent with our experimental findings. Copyright 2001 Academic Press.

Journal Article↗

Motor imagery in mental rotation: an fMRI study.

Twelve right-handed men performed two mental rotation tasks and two control tasks while whole-head functional magnetic resonance imaging was applied. Mental rotation tasks implied the comparison of different sorts of stimulus pairs, viz. pictures of hands and pictures of tools, which were either identical or mirror images and which were rotated in the plane of the picture. Control tasks were equal except that stimuli pairs were not rotated. Reaction time profiles were consistent with those found in previous research. Imaging data replicate classic areas of activation in mental rotation for hands and tools (bilateral superior parietal lobule and visual extrastriate cortex) but show an important difference in premotor area activation: pairs of hands engender bilateral premotor activation while pairs of tools elicit only left premotor brain activation. The results suggest that participants imagined moving both their hands in the hand condition, while imagining manipulating objects with their hand of preference (right hand) in the tool condition. The covert actions of motor imagery appear to mimic the "natural way" in which a person would manipulate the object in reality, and the activation of cortical regions during mental rotation seems at least in part determined by an intrinsic process that depends on the afforded actions elicited by the kind of stimuli presented.

Adult↗

Human adaptation to rotated vision: interplay of a continuous and a discrete process.

The mechanisms for adaptation to visual rotation were investigated by exposing subjects to different rotation angles in a stepwise fashion. We found that response direction continuously changed to compensate for the imposed rotation, but this change was limited to 90 deg. Larger changes were accomplished by inverting both spatial axes (which is equivalent to a 180 deg rotation), and then gradually changing response direction "backwards" to the prescribed value. The angle of 0 deg had no such limiting value like 90 deg: Response direction could continuously change through 0 deg and beyond. Our data provided no evidence that adaptation to opposite-directed visual rotations results in interference, due to competition in working memory; instead subjects' performance under such conditions is fully explained by the said continuous changes of response direction. We conclude that adaptation is achieved by a coordinated interplay of continuous (gradual rotation between +/-90 deg) and discrete (sign reversal) processes.

Adaptation, Physiological↗

Changes in perception of active but not passive turning following stepping on the rotating treadmill.

The purpose of this work was to determine whether walking on a rotating disc would cause changes in perception of active and passive turning. Ten healthy control subjects wore a blindfold and earplugs while completing trials of active and passive turning. For active conditions, subjects were told the direction and amplitude of the desired turn and then attempted to turn in place the specified amount via actively stepping. For passive conditions, subjects were told that the disc they stood on would turn and they were to press a button when they had traveled the specified amplitude. Subjects completed active and passive trials to the left and right with amplitudes of 90, 180, 270, and 360 degrees. Subjects then stepped in place for 15 min on a disc rotating clockwise at 90 degrees /s, after which they repeated the trials of active and passive turning. Following rotating treadmill stimulation, subjects asked to turn in the direction opposite disc rotation (i.e., to the left) consistently and significantly overshot their targets in active trials. There were no changes in accuracy of active turning to the right or passive turning in either direction. This indicates that adaptation to the rotating treadmill is expressed even when subjects have a conscious intent to turn. The positive after-effects of the rotating treadmill add to the intended active turning in the direction of the after-effect but there is no decrement in active turning in the direction opposite the after-effect.

Adult↗

Motion detection and correction using multi-rotation 180 degrees single-photon emission tomography for thallium myocardial imaging.

Patient and organ motion is a potentially limiting factor in gamma camera single-photon emission tomography (SPET) imaging, as highlighted in stress thallium myocardial SPET, where the heart may exhibit a systematic axial motion (cardiac creep) following stress. Multi-rotation SPET has previously been described as a means of obtaining better raw data for motion detection and correction. This study describes the validation of a computerised motion detection algorithm applied to multi-rotation SPET, and reports measured motions in thallium myocardial stress SPET studies from a single-headed gamma camera. Forty-two patients underwent pharmacological stress (dipyridamole) with leg raising, with injection of 75 MBq thallium-201 and imaging after a 10-min delay to detect or evaluate coronary artery disease. Multi-rotation gamma camera SPET was performed with a single-headed gamma camera, with five sequential rapid (4.5 min) continuous SPET mode rotations over 180 degrees. A one-dimensional cross-correlation alignment technique was applied to the projection images to perform motion detection and correction in the axial direction prior to combining the five data sets for tomographic reconstruction. Validation of the cross-correlation alignment analysis was carried out by performing imaging with measured whole-body axial motions in nine subjects, and by reproducibility measurements on multi-rotation data sets. The effect of the applied motion correction was evaluated by calculating mean differences between image pairs before and after shifting, and the general reliability of the automatic motion detection was checked to within one pixel by visual assessment of 160 image pairs. Validation measurements of the cross-correlation technique gave a mean absolute error of 1.5+/-0.4 mm (0.24+/-0.06pixels) with a maximum error of 3.7 mm (0.6 pixels). In 40 subjects undergoing pharmacological stress 201Tl myocardial SPET imaging, the mean cardiac axial creep movement was calculated as 3.1+/-0.7 mm (0. 49+/-0.11 pixels), with 13 out of 40 (32%) having a calculated motion of 1 pixel (6.3 mm) or more. The automatic image shift was visually judged to be within 1 pixel in all 160 image pair analyses, and the mean pixel value difference between image pairs was reduced following image shifting. It is concluded that multi-rotation 180 degrees SPET imaging provides raw data which allow objective and accurate motion detection of cardiac motion in thallium stress myocardial imaging, whilst the one-dimensional cross-correlation technique demonstrates adequate accuracy and reliability to be applied as an automatic motion screening technique on these data.

Dipyridamole↗