[Preliminary results of coronary artery examination using a 3D-navigator sequence on a high performance MR system].

PURPOSE: To evaluate MR coronary angiography using a three-dimensional navigator echo sequence on a MR scanner with a high performance gradient system. MATERIAL AND METHODS: Five healthy volunteers were examined with a 1.5 Tesla MR system, using a high performance prototype gradient system (peak amplitude 50 mT/m, rising time 600 mus). For imaging, a navigated gradient-echo pulse sequence with an in-plane resolution between 0.63 x 0.63 and 0.78 x 0.78 mm2 was used. Per patient two overlapping slabs were acquired. The number of visualized coronary artery segments was estimated (AHA classification). In addition, signal-to-noise measurements were performed in the ascending aorta at the level of the proximal right and left coronary arteries. RESULTS: In all volunteers the left main, the right coronary artery up to segment 3, the LAD up to segment 8 and the RCX with segment 11 and 13 were clearly visualized. The average signal-to-noise value at the level of the right coronary artery was 11.4 +/- 5.0, at the level of the left coronary artery 12.3 +/- 4.5. One volunteer was measured with an in-place resolution of 0.63 x 0.63 mm2. This resulted in a too low signal-to-noise ratio so that an adequate assessment of coronary arteries was no longer possible. CONCLUSION: 3D-MR coronary angiography using the navigator technique is limited by the signal-to-noise ratio.

Adult↗

Estimation of the left ventricular ejection fraction using a novel multiphase, dark-blood, breath-hold MR imaging technique.

OBJECTIVE: In this paper, we evaluate a recently proposed dual-phase dark-blood MR sequence for estimating the left ventricular ejection fraction, compare Simpson's method of estimation of ejection fraction with a model based on the biplane method, assess the reproducibility of both methods, and finally, test a semiautomated method for contouring the endocardial border. SUBJECTS AND METHODS: An MR pulse sequence was implemented to acquire cardiac images in both diastolic and systolic phases within a single breath-hold. A special magnetization preparation scheme rendered blood dark while a segmented acquisition allowed breath-hold scan times. Five healthy volunteers and five patients with cardiac disease were imaged. Ejection fractions were estimated using (1) long-axis and four-chamber biplane views with an ellipsoid model and (2) a series of short-axis views in combination with Simpson's model. These values of ejection fractions were then compared with values obtained from echocardiography. RESULTS: Estimates of ejection fractions obtained using biplane ellipsoid volume and Simpson's rule methods varied by 14% in healthy volunteers. However, for patients with severe cardiomyopathy, differences between the values of ejection fraction obtained with the two methods varied by as much as 150%. Ejection fraction estimates obtained from MR images with the biplane ellipsoid method and from echocardiography varied by approximately 14% for all subjects. Ejection fraction estimates obtained with the semiautomated algorithm agreed well with estimates obtained with manual contours made by experienced radiologists. Intraobserver variability was low for both the short-axis (3%) and biplane (4%) methods. However, interobserver variability of the biplane method (12%) exceeded that of the short-axis method (4%). Interexamination variability (9%) was the largest factor in determining the reproducibility of the ejection fraction estimates. CONCLUSION: Breath-hold dark-blood MR imaging technique with simultaneous acquisition of a series of short-axis views during systolic and diastolic phases permits rapid and accurate estimates of ejection fractions in healthy subjects and in patients. Model based biplane MR imaging methods are less reliable in patients with global cardiomyopathy. The estimation of ejection fractions can be automated using the proposed contouring algorithm and the dark-blood short-axis views.

Adult↗

Temperature and SAR measurements in deep-body hyperthermia with thermocouple thermometry.

Multisensor (7-14) thermocouple thermometry is used at our department for temperature measurement with our 'Coaxial TEM' regional hyperthermia system. A special design of the thermometry system with high resolution (0.005 degrees C) and fast data-acquisition (all channels within 320 ms) together with a pulsed power technique allows assessment of specific absorption rate (SAR) information in patients along catheter tracks. A disadvantage of thermocouple thermometry, EM interference, is almost entirely eliminated by application of absorbing ferrite beads around the probe leads. We investigated the effect of remaining disturbance on the temperature decay after power-off, both experimentally in phantoms and in the clinic, and with numerical simulations. Probe and tissue characteristics influence the response time tau dist of the decay of the disturbance. In our clinical practice a normal pulse sequence is 50 s power-on, 10 s power-off: a response time longer than the power-off time results in a deflection of the temperature course at the start. Based on analysis of temperature decays correction of temperature is possible. A double-pulse technique is introduced to provide an initial correction of temperature, and fast information about accuracy. Sometimes disturbance with a relatively long response time occurs, probably due to a bad contact between probe, catheter and/or tissue. Thermocouple thermometry proved to be suitable to measure the SAR along a catheter track. This is used to optimize the SAR distribution by patient positioning before treatment. A clinical example illustrates this.

Body Temperature↗

Real-time interactive MR imaging system: sequence optimization, and basic and clinical evaluations.

A real-time interactive MR imaging system (real-time MRI) is an MR scanner which has a fast image updating cycle and the ability to freely change slice orientation, just like an ultrasound imaging system. Recently, such a system has been developed and installed on a clinical 1.5-Tesla system. The purpose of this study was to optimize the pulse sequences for clinical use and to evaluate the clinical usefulness and basic functionality of real-time MRI. For T1-weighted imaging, FLASH (fast low angle shot) can be selected, and up to 5 frames per second can be acquired depending on the matrix size. For T2-weighted imaging, true FISP (fast imaging with steady-state precession) can be selected, and up to 4 frames per second can be acquired. Maximum C/N between liver and spleen was obtained at a flip angle of 20 degrees on FLASH. Maximum C/N between cardiac cavity and wall was obtained at a flip angle of 60 degrees on true FISP. Localization of the right and left coronary arteries could be performed within 30 seconds in three volunteers. Although the present real-time MRI system has drawbacks such as low spatial resolution and relatively low contrast resolution, we expect real-time MRI to be one of the most important tools for future clinical MRI.

Adult↗

Spatially localized in vivo 1H magnetic resonance spectroscopy of an intracerebral rat glioma.

Surface coil MRI combined with spatially localized spectroscopy was used to noninvasively detect 1H signals from metabolites within an intracerebral malignant glioma in rats. The MRS pulse sequence was based upon two-dimensional ISIS, which restricted 1H signals to a column-shaped volume, combined with one-dimensional spectroscopic imaging, which further resolved the signals into 8 or 16 slices along the major axis of the column. All experiments were executed with adiabatic pulses which induced uniform spin excitation despite the inhomogeneous radiofrequency field distribution produced by the surface coil transmitter. Surface coil MRI and MRS experiments were performed on phantom samples, normal rat brains, and rat brains harboring malignant gliomas. Spatially resolved in vivo 1H spectra of intracerebral gliomas revealed significantly decreased concentrations of N-acetyl-aspartate and creatine and increased lactic acid (or lipids) as compared to the contralateral hemisphere. These results demonstrate that metabolic abnormalities in intracerebral rat gliomas can be spatially resolved in a noninvasive manner using localized in vivo 1H MRS.

Animals↗

Triple contrast technique for black blood imaging with double inversion preparation.

This work reports on the development of a pulse sequence to simultaneously acquire proton density, T(1), and T(2) weighted images in a single magnetization prepared fast spin echo acquisition. The technique is based upon the application of a magnetization preparation consisting of a global inversion followed by slice-selective 180 degrees and 90 degrees pulses to prepare the signal of specific slices. Slices are acquired in an interleaved manner with time delays appropriate for the desired image contrasts. Data acquisition is repeated for all combinations of slice interleaving covering the region of interest until images from all slice locations have been acquired with all desired image contrasts. The multiple image contrasts obtained with this technique should be useful in applications where discrimination between different types of tissue components is desired, such as in the analysis of plaque in cervical carotid artery disease.

Arteriosclerosis↗

Technologic advances in abdominal MR imaging.

Magnetic resonance (MR) imaging is finding an ever-growing role in the evaluation of a wide range of conditions in the abdomen. No longer confined to problem solving regarding abnormalities in solid organs, such as the liver and kidneys, MR imaging is increasingly being applied to the evaluation of the pancreatic and biliary ductal systems and even the bowel. Recent technical advances in hardware and software have allowed the acquisition of MR images that are largely free of artifact secondary to bowel peristalsis or respiratory motion; images providing excellent anatomic detail can now be obtained routinely. Faster sequences have reduced image acquisition time, thereby improving patient acceptance and allowing more efficient utilization of machine time. New three-dimensional sequences allow rapid image acquisition, reducing section misregistration and motion artifact while improving multiplanar reformations. The potential of MR imaging to provide functional and anatomic information is intriguing, and new techniques, including diffusion and perfusion imaging, are being evaluated. This review considers the advances in imaging hardware and pulse sequence design that underlie the increasing role of MR imaging in evaluation of the abdomen and discusses evolving clinical applications.

Abdomen↗

[Dynamic susceptibility contrast MRI with echo planar imaging using 1.0T system: comparison of different EPI sequences].

Dynamic susceptibility contrast MRI has been performed using the gradient echo sequence on conventional MR imagers. On echo planar imaging (EPI) devices, not only gradient-echo EPI but also spin-echo EPI allow for the monitoring of contrast agent-induced changes in susceptibility. The purpose of this study was to evaluate the contribution of each EPI pulse sequence to susceptibility-induced delta R2(*) through the first pass of a bolus of Gd-DTPA. Thirty healthy volunteers were examined with a 1.0T superconducting MRI unit (IMPACT, Siemens) using EPI. For dynamic susceptibility contrast MRI, we used gradient echo EPI (TE = 60), spin echo EPI (TE = 60) and asymmetric spin echo EPI (TE = 88). Regional relative CBV (rrCBV) maps were generated. On the rrCBV map generated with gradient echo EPI, the high-intensity area of the brain surface was more conspicuous than that generated with spin echo EPI. The rrCBV map generated with asymmetric spin echo EPI represented the contrast between those generated with spin echo EPI and gradient echo EPI. The rrCBV rate between gray matter and white matter with gradient echo EPI was significantly higher than that with spin echo EPI. We suggest that the rrCBV map calculated with spin echo EPI tends to reflect capillary blood volume and the rrCBV map calculated with gradient echo EPI tends to reflect total blood volume.

Adult↗

Hepatic MR imaging: comparison of RARE derived sequences with conventional sequences for detection and characterization of focal liver lesions.

BACKGROUND: We compared two T2-weighted turbo spin echo (TSE) sequences with a T2-weighted conventional SE (CSE) sequence to determine whether sequences derived from rapid acquisition with relaxation enhancement such as TSE could replace CSE for the detection and subsequent characterization of focal liver lesions. METHODS: A total of 55 consecutive patients with 107 liver lesions underwent magnetic resonance imaging examinations at 1.5 Tesla, with a constant imaging protocol. TSE pulse sequences were acquired with eight echo trains (repetition time [TR], 4718 ms; echo time [TE], 90 ms; acquisition time [TA], 4.03 min; and a symmetric k-space ordering scheme) and 11 echo trains (TR, 4200 ms; TE, 140 ms; TA, 4.40 min; and an asymmetric k-space ordering scheme) and compared with CSE (TR, 2300 ms; TE, 45/90 ms; TA, 9.53 min). Images were analyzed qualitatively by scoring image quality and artifacts and counting focal liver lesions by independent reading with consensus obtained for discrepancies. Quantitative analysis was performed by measuring signal-to-noise (S/N), contrast-to-noise (C/N), and tumor-liver signal intensity (T/L) ratios. RESULTS: T2-weighted TSE sequences provided better subjective image quality and reduced artifacts as compared with the T2-weighted CSE sequence. CSE and TSE sequences exhibited no statistically significant differences in liver S/N, lesion-liver C/N (CSE TE, 90 ms: 18.6 +/- 14.0; TSE TE, 90 ms: 16.5 +/- 12.9) and the detectability of focal liver lesions. Heavily T2-weighted TSE with a TE of 140 ms allowed correct characterization of focal liver lesions based on a T/L ratio of 3.0 in 84% of patients. CONCLUSIONS: T2-weighted TSE sequences are as suited as CSE for the detection (TE, 90 ms), and appear to be superior for the characterization (TE, 140 ms), of focal hepatic lesions. Whether a single sequence, such as a double-echo TSE or a single-echo TSE sequence with a TE between 110 and 120 ms, might perform both functions as well or better than CSE is unknown. However, because of time savings, TSE eventually may be preferred over CSE.

Artifacts↗

Comparison of five MR sequences for the detection of acute intracranial hemorrhage.

PURPOSE: To evaluate the respective value of 5 MR sequences to distinguish between stroke patients with and without acute intracerebral hemorrhage (ICH). METHODS: MR images obtained < or =6 h after stroke onset of 86 patients (43 ICH, 43 non-ICH) were reviewed by 3 observers who looked for signs of acute ICH on each image set [T(1) and T(2) gradient echo (GRE), FLAIR, T(2)-EPI and DWI], presented separately. RESULTS: For the identification of ICH, intraobserver and interobserver concordance were at least kappa = 0.95 for all sequences. Of all interpretations, 7 (0.4%) were erroneous, with sensitivity and specificity of FLAIR, T(2)-EPI and DWI reaching 100%; GRE sensitivity and specificity were 100% and 95-97.5%, respectively; T(1) sensitivity and specificity were 97.3-100% and 97.4-100%, respectively. All 4 patients misclassified on one pulse sequence were correctly classified on all the other sequences. CONCLUSION: In the setting of acute stroke, each of the 5 studied sequences enables ICH and non-ICH patients to be distinguished with high sensitivity and specificity.

Acute Disease↗

13C natural abundance S3E and S3CT experiments for measurement of J coupling constants between 13Calpha or 1Halpha and other protons in a protein.

It is demonstrated that the spin-state-selective pulse sequence elements, S3E and S3CT, previously introduced for measurement of J coupling constants in 15N-labeled proteins can be applied for work with peptides and proteins with 13C at the natural abundance level. In addition, a method is described for suppression of crosstalk caused by passive spin flips and pulse imperfections, which otherwise results in systematically underestimated J coupling constants and thereby inaccurate structural constraints. This method is also applicable for crosstalk suppression in applications of S3E and S3CT to 13C- or 15N-labeled samples. Experimental confirmation is obtained using a 10 mM BPTI sample focusing on 13C in the alpha position. The measured J coupling constants include 3J(HN-Halpha) and 3J(Halpha-Hbeta) related to the phi and chi1 angles, respectively.

Carbon Isotopes↗

A novel technique for imaging with inhomogeneous fields.

We introduce a simple, efficient, low-SAR method for magnetic resonance imaging in the presence of a static field with a permanent, and possibly large gradient. The technique, which is called slant-slice imaging is essentially a spin-echo imaging sequence except that the imaging slice is oriented such that the static field gradient can be used in conjunction with applied gradients during readout. Data are collected for 2D slices. Unlike single point imaging techniques, entire lines of k-space are acquired with each readout. The slant-slice pulse sequence is used to obtain high quality images, using a clinical scanner to simulate a static field with a large permanent gradient. The effects of the inhomogeneity are quantified by two parameters nu and q, which are useful for assessing the utility of a magnet design for 3D-MR imaging.

Algorithms↗

Catheter-tracking FOV MR fluoroscopy.

Recent improvements in intravascular magnetic resonance imaging techniques mandate an accurate method of monitoring the introduction of MR catheter probes into the vessel of interest. For this purpose, a novel imaging protocol and a display method have been designed. First, a roadmap 3D image data set with standard pulse sequences is obtained using an external imaging coil. Subsequently, using very narrow rectangular-FOV fast-spoiled gradient recalled (SPGR), a movie of the percutaneous placement procedure of an MR catheter probe is acquired at a rate of 7.3 frames/second. In this protocol, the probe is used to transmit RF pulses and receive MR signal. A computer program was written for image unwrapping and for displaying the unwrapped movie frames on the roadmap image. In an alternative protocol, the movie frames in two projection angles were acquired in an interleaved fashion. Frames were unwrapped and combined with a 3D roadmap and displayed on a Silicon Graphics workstation equipped with stereovision goggles. Using these methods, percutaneous catheter placement in a phantom and a dog was examined. In conclusion, a new visualization technique for MR catheter placement is proposed. Combining this technique with high resolution intravascular MRI techniques may result in a very useful diagnostic tool for the evaluation of atherosclerosis and other vessel diseases.

Algorithms↗

Gradient moment nulling for steady-state free precession MR imaging of cerebrospinal fluid.

Steady-state free precession (SSFP) pulse sequences can produce magnetic resonance (MR) images rapidly, in which cerebrospinal fluid (CSF) is several times more intense than the other tissues. However, motion in the presence of magnetic field gradients reduces the intensity of CSF drastically, unless the time integral of the gradient waveform between each radio-frequency (rf) pulse vanishes. The consequences of motion on SSFP are explored here in detail theoretically and experimentally. The principle of gradient moment nulling is applied with the objective of giving CSF in SSFP images uniformly high intensity everywhere, in spite of motion. Theoretical analysis of the phase of the transverse magnetization from a group of isochromats, with a trajectory described by a Taylor series, reveals how motion along each direction disrupts SSFP and also causes ghost artifacts. Images of CSF in the cervical spine are found to have less extensive flow voids and weaker ghosts from pulsation if the first moment calculated from the rf pulse to the center of the gradient echo vanishes for both the frequency encoding and slice selection gradient waveforms. However, first-order moment nulling of the phase encoding gradient waveform is unnecessary for SSFP imaging of CSF.

Cerebrospinal Fluid↗

Magnetic resonance imaging features of fractures using the short tau inversion recovery (STIR) sequence: correlation with radiographic findings.

The MRI characteristics of fractures have been described on the basis of spin echo (SE) images emphasizing T1 and T2 contrast. These previous studies were carried out for injuries in which radiographic proof was often lacking. In comparison with SE images, short tau inversion recovery (STIR) images have been shown to provide superior contrast between normal and abnormal marrow. To determine the MRI characteristics of fracture using STIR pulse sequences, we reviewed 28 patients who had radiographic evidence of fracture and were examined with T1-weighted SE and STIR sequences. MRI marrow signal abnormalities were demonstrated at all fracture sites ranging in age from less than 24 h to 8 weeks. The extent of marrow signal abnormalities exceeded the size of corresponding radiographic findings of fracture in all cases. The MRI features of fractures on T1-weighted SE images consisted of irregular intramedullary zones of hypointensity. On STIR images a corresponding zone of hyperintensity extended to the outer cortical margin. Intramedullary lines of hypointensity extending to the inner cortical margin were identified within the hyperintense marrow abnormality on STIR images in 64% of the fractures. The results of this study show that MRI using T1-weighted SE and STIR sequences can consistently demonstrate prominent signal abnormalities at fracture sites including those in which radiographic signs are subtle.

Adult↗

An evaluation of the TSE MR sequence for time efficient data acquisition in polymer gel dosimetry of applications involving high doses and steep dose gradients.

The use of magnetic resonance imaging as a readout method for polymer gel dosimetry commonly involves long imaging sessions, particularly when high spatial resolution is required in all three dimensions, for the investigation of dose distributions with steep dose gradients and stringent dose delivery specifications. In this work, a volume selective turbo spin echo (TSE) pulse sequence is compared to the established Carr-Purcell-Meiboom-Gill (CPMG) multiecho acquisition with regard to providing accurate dosimetric results in significantly reduced imaging times. Polyethylene glycol diacrylate based (PABIG) gels were irradiated and subsequently scanned to obtain R2 relaxation rate measurements, using a CPMG multiecho sequence and a dual echo TSE utilizing an acceleration (turbo) factor of 64. R2 values, plotted against corresponding Monte Carlo dose calculations, provided calibration data of PABIG gels dose response over a wide dose range. A linear R2 versus dose relationship was demonstrated for both sequences with TSE results presenting reduced dose sensitivity. Although TSE data were found to deviate from linearity at lower doses compared to CPMG data, a relatively wide dynamic dose range of response extending up to approximately 100 Gy was observed for both sequences. The TSE and CPMG sequences were evaluated with a brachytherapy irradiation using a high dose rate 192Ir source and a gamma knife stereotactic radiosurgery irradiation with a single 4 mm collimator helmet shot. Dosimetric results obtained with the TSE and CPMG are shown to compare equally well with the expected dose distributions for these irradiations. The 60-fold scan time reduction achieved with TSE implies that this sequence could prove to be a useful tool for the introduction of polymer gel dosimetry in clinical radiation therapy applications involving high doses and steep dose gradients.

Brachytherapy↗

High-resolution DTI with 2D interleaved multislice reduced FOV single-shot diffusion-weighted EPI (2D ss-rFOV-DWEPI).

Diffusion tensor MRI (DTI), using single-shot 2D diffusion weighted-EPI (2D ss-DWEPI), is limited to intracranial (i.c.) applications far from the sinuses and bony structures, due to the severe geometric distortions caused by significant magnetic field inhomogeneities at or near the tissue-air or tissue-bone interfaces. Reducing these distortions in single-shot EPI by shortening the readout period generally requires a reduced field of view (and the potential of wraparound artifact) in the phase-encoding direction and/or reduced spatial resolution. To resolve the problem, a novel 2D reduced FOV single-shot diffusion-weighted EPI (2D ss-rFOV-DWEPI) pulse sequence applicable for high resolution diffusion-weighted MRI of local anatomic regions, such as brainstem, cervical spinal cord, and optic nerve, has been developed. In the proposed technique, time-efficient interleaved acquisition of multiple slices with a limited FOV was achieved by applying an even number of refocusing 180 degrees pulses with the slice-selection gradient applied in the phase-encoding direction. The two refocusing pulses used for each slice acquisition were separated by a short time interval (typically less than 45 ms) required for the 2D EPI echotrain acquisition. The new technique can be useful for high resolution DTI of various anatomies, such as localized brain structures, cervical spinal cord, optic nerve, heart, or other extra-cerebral organ, where conventional 2D ss-DWEPI is limited in usage due to the severity of image distortions.

Algorithms↗

Comprehensive MR imaging of acute gynecologic diseases.

Rapid advances in techniques of magnetic resonance (MR) imaging have enabled diagnosis of acute gynecologic conditions, which are characterized by sudden onset of lower abdominal pain, fever, genital bleeding, intraperitoneal bleeding, or symptoms of shock. The chemical-selective fat-suppression technique not only helps establish the characteristics of lesions that contain fat components but also increases the conspicuity of inflammatory lesions. When a T2-weighted image is obtained with a very long effective echo time (>250 msec), even a small amount of ascites can be easily identified and the contrast between urine and complex fluid becomes more conspicuous. T2*-weighted images are useful for identification of hemorrhagic lesions by demonstrating deoxyhemoglobin and hemosiderin. Contrast material-enhanced dynamic subtraction MR imaging performed with a three-dimensional fast field-echo sequence and a rapid bolus injection of gadopentetate dimeglumine allows evaluation of lesion vascularity and the anatomic relationship between pelvic vessels and a lesion and allows identification of the bleeding point by demonstrating extravasation of contrast material. To optimize the MR imaging examination, attention should be given to the parameters of each pulse sequence and proper combination of the sequences.

Diagnosis, Differential↗