Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “OCCLUSIVE DRESSINGS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84Linked to original sources

Diverse applications of negative pressure wound therapy: a multiple case report.

The purpose of this retrospective case report was to describe the results of negative pressure wound therapy (NP WT) in the treatment of wounds of various size, location and etiology in four patients. The effects of NP WT were assessed in the following patients. 1) A 68-year-old male diagnosed with cellulitis presenting with two open wounds on the left foot; 2) a 60-year-old male diagnosed with Type II diabetes mellitus presenting with a full thickness wound on the plantar surface of the right foot; 3) a 64-year-old male diagnosed with necrotizing fasciitis, diabetes mellitus, and Crohn's disease presenting with a left gluteal wound; and 4) a 47-year-old obese female diagnosed with necrotizing fasciitis presenting with a wound of the right groin and buttock. All wounds were debrided of devitalized tissue and contained nearly 100% granulation tissue prior to NPWT treatment. NPWT was applied three times per week, each application lasting 48 hrs, followed by dressing change, cleaning of the wound bed and continued debridement as required. Treatment duration, varying from 4-9 weeks, corresponded to the patient's length of stay at the sub-acute rehabilitation facility, and pressure settings ranged from 100 to 200 mmHg. Measurements of wound length, width, depth and appearance were recorded once a week. Follow-up was conducted 6-18 months post treatment to assess self-reported wound status. NPWT resulted in reductions of wound length, width, and depth, with the greatest reduction in each case being wound depth. Reduction in wound depth ranged from 75-100% (100% being complete wound closure), with four of the five wounds exceeding 90%. Reduction in wound length ranged from 32-100%, with three wounds exceeding 80%, and reduction in wound width ranged from 35-100%, with three wounds exceeding 80%. Three wounds closed completely either during therapy or soon (2-4 weeks) thereafter, and two wounds were reduced in size sufficiently for treatment via skin grafts. NPWT, applied to wounds of diverse size, location, and etiology, resulted in reductions in wound length, width, and depth in four patient cases, with the greatest influence of reducing wound depth.

Aged↗

Modified cotton gauze dressings that selectively absorb neutrophil elastase activity in solution.

Dressings for chronic human wounds have been aimed at protection, removal of exudate, and improved appearance. However since the time of ancient Greece wound care and dressing strategies have primarily relied on empiricism. Recent studies have shown that chronic wounds contain high levels of tissue and cytokine destroying proteases including collagenase and neutrophil elastase. Therefore we sought to develop an effective wound dressing that could absorb elastase through affinity sequestration. Cotton gauze was modified by oxidation, phosphorylation, and sulfonation to enhance elastase affinity by ionic or active site uptake. Type VII absorbent cotton gauze was oxidized to dialdehyde cotton which was subsequently converted in part to the bisulfite addition product. Gauze preparations were also phosphorylated and carboxymethylated. Modified cotton gauzes were compared with untreated gauze for reduction of elastase activity in buffered saline. Solutions of elastase that were soaked in oxidized, sulfonated, and phosphorylated cotton gauze showed reduced elastase activity. The initial velocities (v(o)) and turnover rates of elastase showed significant decreases compared with solutions taken from untreated gauze. The reduction in enzyme activity with dialdehyde cotton gauze was confirmed in solution by determining elastase inhibition with dialdehyde starch. The dialdehyde cotton gauze also decreased elastase activity in human wound fluid in a dose response relation based on weight of gauze per volume of wound fluid. Absorbency, pH, air permeability and strength properties of the modified gauze were also compared with untreated cotton gauze. This report shows the effect of reducing elastase activity in solution with cotton containing aldehydic or negatively charged cellulose fibers that may be applicable to treatment modalities in chronic wounds.

Absorption↗

The role of oxidised regenerated cellulose/collagen in wound repair: effects in vitro on fibroblast biology and in vivo in a model of compromised healing.

Irrespective of underlying chronic wound pathology, delayed wound healing is normally characterised by impaired new tissue formation at the site of injury. It is thought that this impairment reflects both a reduced capacity to synthesize new tissue and the antagonistic activities of high levels of proteinases within the chronic wound environment. Historically, wound dressings have largely been passive devices that offer the wound interim barrier function and establish a moist healing environment. A new generation of devices, designed to interact with the wound and promote new tissue formation, is currently being developed and tested. This study considers one such device, oxidised regenerated cellulose (ORC) /collagen, in terms of its ability to promote fibroblast migration and proliferation in vitro and to accelerate wound repair in the diabetic mouse, a model of delayed wound healing. ORC/collagen was found to promote both human dermal fibroblasts proliferation and cell migration. In vivo studies considered the closure and histological characteristics of diabetic wounds treated with ORC/collagen compared to those of wounds given standard treatment on both diabetic and non-diabetic mice. ORC/collagen was found to significantly accelerate diabetic wound closure and result in a measurable improvement in the histological appearance of wound tissues. As the diabetic mouse is a recognised model of impaired healing, which may share some characteristics of human chronic wounds, the results of this in vivo study, taken together with those relating the positive effects of ORC/collagen in vitro, may predict the beneficial use of this device in the clinical setting.

Adult↗

A silver-impregnated antimicrobial dressing reduces hospital costs for pediatric burn patients.

PURPOSE: Since using a novel silver-impregnated antimicrobial dressing (Aquacel Ag, ConvaTec, Princeton, NJ) in our pediatric patients with partial-thickness burns, hospital LOS has been significantly reduced. Here we investigated whether there was concomitant cost-effectiveness of this approach. METHODS: We retrospectively reviewed Burn Registry Data from a large Children's Hospital Burn Unit from January 2005 through August 2005 for inpatients with partial-thickness burns treated with Aquacel Ag. A comparison group was composed of patients from the same period the previous year treated with silver sulfadiazine cream (SSD, Par Pharmaceuticals, Woodcliff, NJ) and matched for age and %TBSA burned. Patients with inhalation injury or full-thickness burns were excluded. Intent-to-treat analysis was limited to patients with less than 22% TBSA burn. Direct costs and total charges were compared statistically after log transformation due to the skewedness of the data. RESULTS: Total charges and direct costs were significantly lower for Aquacel Ag-treated patients (n = 38) than for SSD-treated patients (n = 39) (P = .004 and P < .001, respectively). In addition, Aquacel Ag-treated patients had a shorter LOS than SSD-treated patients. DISCUSSION: These data strongly support our findings that the application of Aquacel Ag reduces hospital LOS which results in a significant cost savings in the care of pediatric patients with partial-thickness burns.

Anti-Infective Agents, Local↗

Artificial dermis for major burns. A multi-center randomized clinical trial.

This communication presents an 11-center prospective randomized trial using the artificial dermis invented by Burke and Yannas. Patients with life-threatening burns who underwent primary excision and grafting within 7 days of injury had comparable sites randomized to receive either the artificial dermis (study site) or the investigator's usual skin grafting material (control site). Control materials were autograft, allograft, xenograft, or a synthetic dressing. Epidermal grafts were applied to the study site during a second operation, and surviving patients were followed for 1 year after grafting. One hundred thirty-nine sites on 106 patients were studied. Mean burn size was 46.5 +/- 15% mean total body surface (TBSA). Overall mortality was 13%, and mean hospital stay was 68 +/- 45 days. Median artificial dermis take was 80% compared with 95% for all comparative sites, but the take was equivalent to that of all nonautograft control materials. Results with the artificial dermis improved slightly as the investigators became more familiar with the material. Donor site thickness for the study site averaged .006'' +/- .002'' compared to .013'' +/- .018'' for control (p less than .0001) and the epidermal donor site healed an average of 4 days sooner (10 +/- 6 vs. 14 +/- 8 days) (p less than .0001). As the wounds matured during the first year, both patients and surgeons felt that both sites became more comparable in appearance and function. At the completion of the study, there was less hypertrophic scarring of the artificial dermis, and more patients preferred the artificial dermis to the control graft. Artificial dermis with an epidermal graft provides a permanent cover that is at least as satisfactory as currently available skin grafting techniques, and uses donor grafts that are thinner and donor sites that heal faster.

Adolescent↗

A prospective, randomized trial of Unna's boot versus Duoderm CGF hydroactive dressing plus compression in the management of venous leg ulcers.

Leg ulcers caused by chronic venous insufficiency plague an estimated 500,000 Americans, but there have been few improvements in conservative treatment in this century, and Unna's boot continues to be a mainstay of therapy. A recent report suggests that Duoderm CGF dressing provides greater patient comfort and enhanced compliance, but Duoderm alone (without compression) resulted in slower healing compared with Unna's boot. We enrolled 30 patients (30 ulcers) in a clinical trial to compare Duoderm CGF plus compression (Coban wrap) to Unna's boot. No significant difference was observed between the two groups with respect to age, sex, initial ulcer area, ulcer duration, or extent of venous insufficiency by duplex scan. Eight of 16 ulcers (50%) in the Duoderm group healed completely versus 6 of 14 ulcers (43%) in the Unna's boot group (p = 0.18). Healing rates (square centimeters per week) correlated significantly with initial ulcer area and initial ulcer perimeter for both groups but best correlated with initial ulcer perimeter (r = 0.88 with Duoderm, p less than 0.0001; r = 0.80 with Unna's boot, p less than 0.002). After adjusting for differences in initial ulcer perimeter, healing rates were significantly faster for patients on Duoderm than patients on Unna's boot during the first 4 weeks of therapy (0.384 +/- 0.059 cm2/wk/cm perimeter for Duoderm versus 0.135 +/- 0.043 cm2/wk/cm perimeter for Unna's boot; p = 0.002). At 12 weeks patients on Duoderm again appeared to heal faster than those on Unna's boot, although the result did not reach statistical significance (0.049 +/- 0.007 cm2/wk/cm perimeter for Duoderm versus 0.020 +/- 0.017 for Unna's boot, p = 0.11).(ABSTRACT TRUNCATED AT 250 WORDS)

Analysis of Variance↗

Mechanisms and clinical applications of the vacuum-assisted closure (VAC) Device: a review.

The use of sub-atmospheric pressure dressings, available commercially as the vacuum-assisted closure (VAC) device, has been shown to be an effective way to accelerate healing of various wounds. The optimal sub-atmospheric pressure for wound healing appears to be approximately 125 mm Hg utilizing an alternating pressure cycle of 5 minutes of suction followed by 2 minutes off suction. Animal studies have demonstrated that this technique optimizes blood flow, decreases local tissue edema, and removes excessive fluid from the wound bed. These physiologic changes facilitate the removal of bacteria from the wound. Additionally, the cyclical application of sub-atmospheric pressure alters the cytoskeleton of the cells in the wound bed, triggering a cascade of intracellular signals that increases the rate of cell division and subsequent formation of granulation tissue. The combination of these mechanisms makes the VAC device an extremely versatile tool in the armamentarium of wound healing. This is evident in the VAC device's wide range of clinical applications, including treatment of infected surgical wounds, traumatic wounds, pressure ulcers, wounds with exposed bone and hardware, diabetic foot ulcers, and venous stasis ulcers. VAC has also proven useful in reconstruction of wounds by allowing elective planning of the definitive reconstructive surgery without jeopardizing the wound or outcome. Furthermore, VAC has significantly increased the skin graft success rate when used as a bolster over the freshly skin-grafted wound. VAC is generally well tolerated and, with few contraindications or complications, is fast becoming a mainstay of current wound care.

Debridement↗

Allogeneic cultured dermal substitute composed of spongy collagen containing fibroblasts: evaluation in animal test.

The authors developed a cultured dermal substitute (CDS) composed of a spongy collagen containing cultured fibroblasts. The cultured fibroblasts derived from Sprague Dawley rat skin were seeded on a spongy collagen at a density of 5 x 10(5) cells cm(-2) and cultured for 7 days. This CDS was applied to the debrided wound of full-thickness burn which was inflicted experimentally on the dorsum of Wister rat, and then the wound conditions were observed over a period of 2 weeks. The comparative study was conducted using an acellular spongy collagen as well as a commercially available temporary wound dressing, Biobrane, since a different type of cultured dermal substitute, Dermagraft-TC, is composed of Biobrane, whose inner site is combined with cultured fibroblasts. Each covering material was applied on the debrided wound area and exchanged by new one 1 week later. When the debrided wound was covered with Biobrane, a small portion of necrotic tissue was observed 1 week after application, and the granulation tissue formation was greatly delayed. This wound area showed a poor granulation tissue even 2 weeks later. On the contrary, when covered with an acellular spongy collagen, no necrotic tissue was observed. This wound area showed a more or less irregular granulation tissue at 1 week and then a healthy granulation tissue 2 weeks later. This preliminary comparative study suggests that an acellular spongy collagen is able to function as a more suitable matrix for CDS, compared with Biobrane. The wound area covered with a CDS assumed a moist, shiny, and hyperaemic appearance 1 week after application showing a healthy granulation tissue. The macroscopic evaluations indicate that the CDS is able to prepare a healthy granulation tissue at an earlier stage, compared with the acellular spongy collagen. In addition, the histologic views demonstrate that the CDS is able to prepare a thicker and denser granulation tissue, compared with the acellular spongy collagen. Although the fate of cultured fibroblasts in the CDS on the wound surface within 1 week is not clear, these findings suggest that fibroblasts in CDS are able to provide excellent conditions for wound healing.

Animals↗

Povidone-iodine in polyethylene oxide hydrogel dressing. Effect on multiplication of Staphylococcus aureus in partial-thickness wounds.

We studied the ability of a polyethylene oxide hydrogel dressing (Vigilon) containing povidone-iodine to prevent Staphylococcus aureus proliferation in partial-thickness wounds. We previously reported that a single application of povidone-iodine on wounds challenged with 2 X 10(6) S aureus was not effective in reducing the number of S aureus after 24 hours. It was therefore hypothesized that povidone-iodine might be effective if it was available continuously and applied to wounds containing a smaller number of bacteria. To test this hypothesis, we made multiple partial-thickness wounds (5 X 7 X 0.3 mm) on six domestic pigs. We then inoculated the wounds by scrubbing them with either a low concentration (log 3.5) or a high concentration (log 7) of S aureus suspension. The wounds were either treated with Vigilon or Vigilon containing povidone-iodine or left air exposed. Wounds from each of these treatment groups were cultured by the scrub technique for S aureus with a 0.5% sodium thiosulfate-polysorbate (Tween) 80 solution 5 minutes, 30 minutes, 24 hours, or 48 hours later. A significant reduction in the number of S aureus recovered from wounds treated with Vigilon containing povidone-iodine was seen with the group inoculated with a low bacterial concentration after 24 hours; but no reductions were observed when wounds were inoculated with the higher bacterial concentration of log 7. We found Vigilon containing povidone-iodine to be an effective inhibitor of S aureus in wounds over a 24-hour period when the organism was present in low numbers.

Animals↗

Treatment of chronic leg ulcers with a hydrocolloid dressing.

The effects of a hydrocolloid dressing (Comfeel Ulcus) on the physical environment of chronic leg ulcers in 58 consecutive out-patients were investigated. Patients were subdivided into two groups of which Group 1 included 31 (53.4%) and Group 2, 27 (46.6%) patients. Twenty-three (39.7%) patients healed within 7 weeks (study period) and 49 (84.5%) within 1 year (follow-up period). Aerobic and anaerobic bacterial cultures as well as mycotic cultures were performed from ulcer bases of both groups of patients. In Group 1 a 3 mm punch biopsy was taken from the ulcer margins for histopathological examination. In Group 2 serum levels of iron, zinc, copper and selenium were measured and in these latter patients a mean temperature difference of 2.8 degrees C between the ulcer base and the skin surrounding the ulcer was found. There was no difference in ulcer pH in patients belonging to Group 2, independent of bacterial or fungal contamination. Low serum iron was found in 74.1% and anaemia in 40.7% of the patients in Group 2. No differences in ulcer healing were seen in these patients compared with those without iron-deficiency or anaemia. No differences were seen in serum iron, zinc, copper or selenium levels between good and poor healers. There were 22.2% ulcer relapses in Group 1 within a year of the start of the study, with no relapses in those 15 patients of Group 2 who used specially designed compression stockings.

Adult↗

"Instant vision" compared with postoperative patching: clinical evaluation and patient satisfaction after bilateral cataract surgery.

PURPOSE: To compare two methods of postoperative dressing regimen: patching vs "instant vision" without patch. DESIGN: Prospective randomized clinical trial. METHODS: Sixty consecutive hospitalized, nonambulatory patients with cataract surgery under topical anesthesia on both eyes at different days were enrolled prospectively. In randomized order, one eye was patched for the first 24 hours postoperatively; the other eye was left open without patch to obtain "instant vision." Both eyes received the same anti-inflammatory and antibiotic drop therapy. RESULTS: Twenty-four hours postoperatively, no significant differences between patching and "instant vision" could be found for corrected and uncorrected visual acuity, corneal epithelial defects, conjunctival inflammation, anterior chamber flare, and intraocular pressure (P > .05). During the first 24 hours postoperatively, all tear film parameters were significantly worse in the "instant vision" eyes (P < .001), indicating a transient tear film instability. During the first four hours after cataract surgery, pain scores in the "instant vision" eyes were significantly higher than in the patched eyes (P < .001). Eight hours postoperatively and later, there were no significant differences in any pain scores (P > .05). After experiencing both methods, 27% of the patients subjectively rated the two methods as equivalent; 8% of the patients preferred "instant vision." Despite of the benefits of immediately improved orientation, 65% of the tested patients preferred patching to "instant vision" because of lower pain and foreign body sensations and psychologic arguments. CONCLUSIONS: The clinical examinations showed that both methods were equally safe for postoperative therapy. However, further efforts have to be made to increase the patients' comfort with "instant vision" in the first hours after cataract surgery.

Aged↗

Use of chitosan bandage to prevent fatal infections developing from highly contaminated wounds in mice.

HemCon bandage is an engineered chitosan acetate preparation used as a hemostatic control dressing, and its chemical structure suggests that it should also be antimicrobial. We tested its ability to rapidly kill bacteria in vitro and in mouse models of infected wounds. We used the Gram-negative species Pseudomonas aeruginosa and Proteus mirabilis and the Gram-positive Staphylococcus aureus that had all been stably transduced with the entire bacterial lux operon to allow in vivo bioluminescence imaging. An excisional wound in Balb/c mice was inoculated with 50-250 million cells followed after 30 min by application of HemCon bandage, alginate sponge bandage, silver sulfadiazine cream or no treatment. HemCon was more adhesive to the wound and conformed well to the injury compared to alginate. Animal survival was followed over 15 days with observations of bioluminescence emission and animal activity daily. Chitosan acetate treated mice infected with P. aeruginosa and P. mirabilis all survived while those receiving no treatment, alginate and silver sulfadiazine demonstrated 25-100% mortality. Chitosan acetate was much more effective than other treatments in rapidly reducing bioluminescence in the wound consistent with its rapid bactericidal activity in vitro as well as its light-scattering properties. S. aureus formed only non-lethal localized infections after temporary immunosuppression of the mice but HemCon was again more effective in reducing bioluminescence. The data suggest that chitosan acetate rapidly kills bacteria in the wound before systemic invasion can take place, and is superior to alginate bandage and silver sulfadiazine that may both encourage bacterial growth in the short term.

Acetates↗

Concomitant use of computer image guidance, linear or sigmoid incisions after minimal shave, and liquid wound dressing with 2-octyl cyanoacrylate for tumor craniotomy or craniectomy: analysis of 225 consecutive surgical cases with antecedent historical control at one institution.

OBJECTIVE: Recent neurosurgical literature reflects rapidly evolving, technically enhanced methods that promise to improve neurosurgical outcomes. We review our experience with computer image guidance, linear or sigmoid incisions after minimal shaving, and liquid wound dressing with 2-octyl cyanoacrylate (Dermabond; Ethicon, Inc., Somerville, NJ) for tumor craniotomy or craniectomy in our attempt to optimize craniotomy or craniectomy for tumor. METHODS: After institutional review board approval, we retrospectively reviewed patients who underwent craniotomy or craniectomy for tumor with or without the combination of techniques specified above. A prior cohort of patients who underwent craniotomy or craniectomy with traditional techniques served as a retrospective basis of comparison. Analysis included in- and outpatient chart reviews, which included the operative notes, pathology reports, discharge summaries, outpatient office records, and intraoperative nursing records. Data were entered into a statistical spreadsheet for analysis and comparison. RESULTS: A total of 225 consecutive patients underwent a combination of less invasive techniques from July 2000 through October 2001. These patients were matched with 225 patients in a standard neurosurgical cohort that included patients who underwent operations from July 1994 through July 2000. Age, tumor type, radiation, reoperation rate, tumor location, and extent of resection were comparable for both groups. The overall wound complication rate was significantly lower in the minimally invasive group when compared with the control cohort of patients (0.9% versus 6.2%; P = 0.0298), even for early follow-up (0.9% versus 3.5%; P = 0.0427). Pedicle flap design was a variable that was significantly associated with wound complication. CONCLUSION: Modern neurosurgical techniques are beneficial for patients undergoing craniotomy or craniectomy for tumor and seem to be superior to standard techniques. Although the study is multifactorial and retrospective, this conclusion is further supported by the enhanced self-image patients have during the postoperative period.

Adult↗

A randomized clinical trial comparing hydrocolloid, phenytoin and simple dressings for the treatment of pressure ulcers [ISRCTN33429693].

BACKGROUND: Pressure sores are important and common complications of spinal cord injury. Many preventive and therapeutic approaches have been tried and new trials are evolving. One relatively recent method is application of a hydrocolloid dressing (HD). In this study we compared the therapeutic effects of HD on pressure ulcer healing with two other topical applications, phenytoin cream (PC) and simple dressing (SD). METHODS: Ninety-one stage I and stage II pressure ulcers of 83 paraplegic male victims of the Iran-Iraq war were randomly allocated to three treatment groups. Mean age and weight of the participants were 36.64 +/- 6.04 years and 61.12 +/- 5.08 kg, respectively. All the patients were managed in long term care units or in their homes for 8 weeks by a team of general practitioners and nurses, and the ulcer status was recorded as "Complete healing", "Partial healing", "Without improvement" and "Worsening". RESULTS: Complete healing of ulcers, regardless of location and stage, was better in the HD group than the PC [23/31(74.19%) vs 12/30(40%); difference: 34.19%, 95% CI = 10.85-57.52, (P < 0.01)] or the SD [23/31(74.19%) vs 8/30(26.66%); difference: 47.53%, 95% CI = 25.45-69.61, (P < 0.005)] groups. Complete healing of stage I ulcers in the HD group [11/13(85%)] was better than in the SD [5/11(45%); difference: 40%, 95% CI = 4.7-75.22, (P < 0.05)] or PC [2/9 (22%); difference: 63%, 95% CI = 29.69-96.3, (P < 0.005)] groups. Complete healing of stage II ulcer in the HD group [12/18 (67%)] was better than in the SD group [3/19(16%); difference: 51%, 95% CI = 23.73-78.26, (P < 0.005)], but not significantly different from the PC group [10/21 (48%); difference: 19%, 95% CI = -11.47-49.47, (P > 0.05)]. We performed a second analysis considering only one ulcer per patient (i.e. 83 ulcers in 83 patients). This "per patient" analysis showed that complete ulcer healing in the HD group was better than in the PC [20/28(71.4%) vs 11/28 (39.3%); difference: 32.1%, 95% CI = 7.4-56.7, (P < 0.01)] or SD [20/28(71.4%) vs 8/27 (29.6%); difference: 41.8%, 95% CI = 17.7-65.8, (P < 0.005)] groups. CONCLUSION: We deduced that HD is the most effective method investigated for treating stage I and II pressure ulcers in young paraplegic men.

Administration, Topical↗

Vacuum-assisted fascial closure for patients with abdominal trauma.

BACKGROUND: Massive fluid resuscitation often is required for patients with intraabdominal trauma. Subsequently, fascial closure is not always possible in this subset of patients. Under these circumstances, an initial step can be the use of a temporary abdominal closure method. The authors currently use a vacuum-assisted closure to manage the open abdomen for some of their trauma patients. They present their experience over the past 3 years. METHODS: From January 2000 to December 2002, 48 trauma patients were treated with temporary abdominal closure using a vacuum-assisted dressing. The ultimate management of the abdominal defect, the serum lactate levels measured in the emergency department, and the fluid balance at the last attempt to accomplish fascial closure were reviewed. RESULTS: Delayed fascial closure was achieved in 23 (71.9%) of 32 patients who survived to discharge (26 of 48, 54.2%). Of the 32 patients who survived to discharge, 9 (28.1%) required an alternative closure, most often a split-thickness skin graft. Of the 16 patients who died before discharge, 8 died within 24 hours after admission. Whereas 5 of the 16 deaths occurred after delayed abdominal closure, 11 patients died without abdominal closure. Emergency department serum lactate levels above 8 mg/dL show a positive correlation with in-hospital mortality (6 of 16 patients; 38%; p = 0.001) and mortality within 24 hours of admission (6 of 8 patients; 75%; p = 0.003). Admission lactate levels were not associated with the type of closure achieved. However, primary closure was associated with a significant decrease in lactate levels during the first 12 hours. Complications included five abdominal abscesses, two enterocutaneous fistulas, and one split-thickness skin graft failure. CONCLUSIONS: Patients requiring temporary abdominal closure have a significant in-hospital mortality rate of 33%. Delayed primary closure with vacuum assistance was achieved for 71.9% of the surviving patients. Maintaining a negative or total positive fluid balance of less than 20 L before the last attempted fascial closure improves successful closure rates, as seen in 19 of 22 patients (86.4%). The vacuum-assisted closure technique also enabled successful primary closure for two patients with extreme delay (>8 days). Elevated serum lactate levels are significantly correlated with early and in-hospital mortality. A significant decrease in lactate level during the first 12 hours is associated with achievement of primary closure.

Abdominal Injuries↗

Bacterial colonization and infection rate of continuous epidural catheters in children.

UNLABELLED: Continuous epidural infusions are widely used for postoperative analgesia in children. We prospectively studied the incidence of bacterial colonization of caudal and lumbar epidural catheters, as well as the incidence of serious systemic and local infection, in 210 children after short-term epidural analgesia. Using aseptic technique, epidural catheters were inserted into either the lumbar or the caudal epidural space based on the preferences of the anesthesia team and/or clinical indication. The integrity of the catheter and overlying transparent dressing site was evaluated by a member of the pediatric pain service at least once a day. The catheters were aseptically removed if the patient had a fever greater than 39 degrees C, if the dressing was compromised, or when epidural analgesia was no longer required. The subcutaneous portion of the catheter was semiquantitatively cultured. Cellulitis (erythema, swelling, purulent discharge, pustule formation, or tenderness) was diagnosed by examination of the epidural insertion site. The mean (+/- SD) age of patients in the caudal catheter group (n = 170) was 3 +/- 3 yr; their mean weight was 13 +/- 11 kg. The mean (+/- SD) age of patients in the epidural catheter group (n = 40) was 11 +/- 4 yr; their mean weight was 36 +/- 23 kg. All catheters remained in place for 3 +/- 1 days (range 1-5 days). There was no serious systemic infection (meningitis, epidural abscess, or systemic sepsis). Of all epidural catheters, 35% (73 of 210) were colonized. Gram-positive colonization was similar in caudal (25%; 43 of 170) and lumbar (23%; 9 of 40) catheters. Gram-negative organisms were cultured from 16% of the caudal catheters (27 of 170) and 3% of the lumbar catheters (1 of 40). In patients treated with caudal epidural catheters, children aged >3 yr were less likely to have colonized epidural catheters than younger children. Age did not affect the probability of developing cellulitis at the insertion site. Although patients aged <3 yr with caudal catheters had a slightly greater risk of cellulitis than children aged >3 yr (14% vs 9%), this association was very weak (P = 0.33). We observed that, despite bacterial colonization of caudal and lumbar epidural catheters, serious systemic and local infection after short-term epidural analgesia did not occur in our study. IMPLICATIONS: Continuous epidural infusions are widely used for postoperative analgesia in children. We found no serious systemic infections after short-term (3 days) continuous epidural analgesia in children.

Abscess↗