Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Friction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84Linked to original sources

Surface structure smoothing effect of polysaccharide on a heat-set protein particle gel.

This work investigates surface properties of a protein particle gel and effects of polysaccharide on the surface microstructure of such a protein gel. Whey protein isolate (WPI) was used as the primary gelling agent, and a polysaccharide (xanthan) was investigated for its surface smoothing effects. The surface properties of heat-set WPI gels with and without the presence of xanthan (0, 0.05, and 0.25%) were characterized using a surface friction technique. The surface friction force of a gel against a stainless steel substrate was found to be highly dependent on the sliding speed for all three gel samples, and the addition of xanthan caused a general reduction of surface friction. The gel containing no xanthan has the largest surface friction and behaved in the most load-dependent manner, whereas the gel containing 0.25% xanthan has the lowest surface friction and showed the least load dependency. It was inferred that the WPI gel containing no xanthan has the roughest surface among the three samples and the presence of xanthan leads to a smoother surface with probably a thinner layer of surface water. Surface features derived from surface friction tests were confirmed by surface microstructure observation from confocal laser scanning microscopy (CLSM) and environmental electron scanning microscopy (ESEM). Surface profiles from CLSM images were used to quantify the surface roughness of these gels. The mean square root surface roughness R(q) was calculated to be 3.8 +/- 0.2, 3.0 +/- 0.2, and 1.5 +/- 0.2 microm for gels containing 0, 0.05, and 0.25% xanthan, respectively. The dual excitation images of protein and xanthan from CLSM observation and images from ESEM observation indicate a xanthan-rich layer at the surfaces of the xanthan-containing gel samples. We speculate that the creation of the outer surface of a particle gel is based on a different particle aggregation mechanism from that leading to network formation in the bulk.

Friction↗

Effects of recycling on the mechanical properties and the surface topography of nickel-titanium alloy wires.

The purpose of this study was to investigate the changes in mechanical properties, surface topography, and frictional forces of various nickel-titanium wires after recycling. Three types of nickel-titanium wires were separated into 3 groups: as-received condition (T0, control group), treated in artificial saliva for 4 weeks (T1), and treated in artificial saliva and autoclaved (T2). Strength changes were observed by tensile testing, and surface topography was assessed by scanning electron microscope and 3-D profilogram. Frictional coefficients were tested by friction test, and fatigue by bending fatigue test. Our findings showed that there were no statistically significant differences between the wires in maximum tensile strength, elongation rate, modulus of elasticity, and bending fatigue. Two wires demonstrated increased pitting and corrosion after recycling. The same 2 wires also demonstrated significantly greater surface roughness and maximum frictional coefficients compared with the control wires (P <.05), but the third wire showed no significant difference. However, surface roughness and frictional coefficient of the 2 wires after recycling were not greater than those of the third wire before treatment. Recycling increased the surface roughness and friction coefficients, but these seemed to have limited clinical significance.

Corrosion↗

A comparison of the forces required to produce tooth movement in vitro using two self-ligating brackets and a pre-adjusted bracket employing two types of ligation.

Friction in fixed appliance systems has received considerable attention in the recent literature, although that attributable to the type of ligation used has not been fully investigated. This in vitro study of 0.022 x 0.028 inch slot Minitwin, Activa ('A' Company, San Diego, California, USA), and SPEED brackets (Strite Industries Ltd., Cambridge, Ontario, Canada), investigates friction in two forms of self-ligating brackets and in two methods of ligating Minitwin straight wire brackets with polyurethane elastomeric ligatures. The resistance to sliding of rectangular archwires through the ligated brackets was measured on a vertically mounted Instron testing machine. The stainless steel archwires used were straight lengths of 0.016" x 0.022", 0.017" x 0.025", 0.018" x 0.025", and 0.019" x 0.025" Nubryte Gold (GAC International Inc., Central Islip, New York, USA). The results showed a significant reduction (P < 0.01) in frictional resistance in the Activa brackets compared with SPEED brackets by a factor of approximately 15. When the SPEED brackets were compared to Minitwin brackets, the reduction in friction was by 50-70 per cent (P < 0.01). The placing of 'figure-of-eight' elastomeric ties increased friction by a factor of 70-220 per cent compared to conventional elastomeric ties (P < 0.01) except for 0.016" x 0.022" archwires. The results indicate that self-ligating brackets require less force to produce tooth movement because they apply less frictional contact to the archwire than conventionally tied siamese brackets.

Analysis of Variance↗

Control strategies correcting inaccurately programmed fingertip forces: model predictions derived from human behavior.

When picking up a familiar object between the index finger and the thumb, the motor commands are predetermined by the CNS to correspond to the frictional demand of the finger-object contact area. If the friction is less than expected, the object will start to slip out of the hand, giving rise to unexpected sensory information. Here we study the correction strategies of the motor system in response to an unexpected frictional demand. The motor commands to the mononeuron pool are estimated by a novel technique combining behavioral recordings and neuromuscular modelling. We first propose a mathematical model incorporating muscles, hand mechanics, and the action of lifting an object. A simple control system sends motor commands to and receives sensory signals from the model. We identify three factors influencing the efficiency of the correction: the time development of the motor command, the delay between the onset of the grip and load forces (GF-LF-delay), and how fast the lift is performed. A sensitivity analysis describes how these factors affect the ability to prevent or stop slipping and suggests an efficient control strategy that prepares and corrects for an altered frictional condition. We then analyzed fingertip grip and load forces (GF and LF) and position data from 200 lifts made by five healthy subjects. The friction was occasionally reduced, forcing an increase of the GF to prevent the object being dropped. The data were then analyzed by feeding it through the inverted model. This provided an estimate of the motor commands to the motoneuron pool. As suggested by the sensitivity analysis the GF-LF-delay was indeed used by the subjects to prevent slip. In agreement with recordings from neurons in the primary motor cortex of the monkey, a sharp burst in the estimated GF motor command (NGF) efficiently arrested any slip. The estimated motor commands indicate a control system that uses a small set of corrective commands, which together with the GF-LF-delay form efficient correction strategies. The selection of a strategy depends on the amount of tactile information reporting unexpected friction and how long it takes to arrive. We believe that this technique of estimating the motor commands behind the fingertip forces during a precision grip lift can provide a powerful tool for the investigation of the central control of the motor system.

Adult↗

Biophysical properties of dry atopic and normal skin with special reference to effects of skin care products.

During recent years several highly developed non-invasive methods for evaluation of skin physiology and pathology have been introduced. Against this background, the present studies were undertaken with the primary aim of assessing the effects of various skin care products on some properties of the skin. Skin topography was measured by profilometry on skin replicas, friction with a newly developed friction instrument, capacitance with a Corneometer, and barrier function both with an Evaporimeter to assess transepidermal water loss (TEWL) and by application of an irritant followed by measurement of the resulting irritative reaction. Initially some of the techniques were used to further characterize the differences between dry atopic skin and normal skin. Dry skin exhibits increased values of roughness parameters and a reduced number of topographical peaks. TEWL is increased, indicating impaired barrier function. The friction and capacitance are lower and correlate significantly to each other, whereas TEWL does not appear to relate to either of these parameters. The use of a scrub cream removes the outermost part of the stratum corneum, resulting in a smoother skin. Application of moisturizers modifies the frictional response of the skin. The friction instrument gave results comparable to those of panelists trained in sensory evaluation. The study suggests that measurement of skin friction can be used to predict the degree of liking of moisturizers. Furthermore, moisturizers increase the skin hydration. They provide water directly to the skin from their water phase. Skin hydration also increases with increased degree of occlusion, as measured as a decrease in TEWL. Moisturizers may also alter the diffusional resistance of the stratum corneum and reduce the skin susceptibility to the surfactant sodium lauryl sulphate (SLS). Lipids in moisturizers may influence already developed SLS-induced irritation. A significantly lower degree of irritation was found in areas treated with canola oil and its sterol-enriched fraction than in an area treated with water. These findings emphasize that skin care products do not only form an inert, epicutaneous layer, but that they may penetrate and influence the structure and function of the skin.

Adolescent↗

[Wear characteristics of different metal-polyethylene beating surfaces. An experimental study of a new model of knee prosthesis].

PURPOSE OF THE STUDY: Wear of artificial components joint is the most important factor in long term durability. Only few studies have analysed in laboratory experimentation the quality of different alloys on the same type of prosthesis. MATERIAL: During the development of a new knee prosthesis, we studied the friction mechanisms of the metal/polyethylene (UHMWPE) couple and particularly the value of titanium alloy (Ti-6AI-4V) treatment using an ionic nitrogen implantation process (IMPLATEC). Two friction surfaces were studied in vitro: one in flexion-extension between femoral component and tibial plateau, the other in rotation between tibial plateau and "metal-back". METHODS: The implanted Ti-6AI-4V was compared with 316L stainless steel, cobalt chromium molybdenium alloy and with Ti-6AI-4V using a prosthesis of each configuration. The samples were tested on a TRIBOCUP friction machine during 3 x 10(6) cycles in Ringer 's solution. The friction couples were controlled every 200,000 cycles and the loss of polyethylene mass every 500,000 cycles. We have also evaluated the roughness and the rubbing surface macroscopically. RESULTS: The results analysis shows that friction couples such as Cobalt Chromium and implanted Ti-6AI-4V are weakest but implanted Ti-6AI-4V over time, tends to match the strength of Ti-6AI-4V without treatment. With implanted Ti-6AI-4V and with Cobalt Chromium alloy, the loss of polyethylene is slight comparatively to the stainless steel and non implanted Ti-6AI-4V. Surface analysis showed good protection of titanium alloy by ionic implantation especially in the femoral component where roughness is close (0.04 micron) to that of Cobalt Chromium alloy (0.07 micron). DISCUSSION: Our study confirms the results with pin-on-disk and cup-on-ball with results for the Ti-6AI-4V implanted and Cobalt Chromium alloys with protection of the metal surface and decrease of polyethylene wear comparatively to stainless steel and non implanted Ti-6AI-4V. CONCLUSION: Our conclusion is for this type of experimental device that the surface condition is satisfactory for such friction couples as implanted Ti-6AI-4V/polyethylene and Cobalt-chromium/polyethylene, with very similar results. However, the long-term durability of the nitrogen implanted on Titanium Alloy remains unknown.

Biodegradation, Environmental↗

Factors influencing stability at the interface between a porous surface and cancellous bone: a finite element analysis of a canine in vivo micromotion experiment.

Several factors contribute to the success of stable bony ingrowth into the porous coated surfaces of orthopaedic implants used in hip arthroplasty. Despite having good bony apposition, bony ingrowth might not occur if the relative motion between bone and implant is large. Therefore, determining the limiting micromotion value that inhibits stable bony ingrowth is important. From a previous canine in vivo micromotion study performed at our laboratory, this limiting value was found to be 20 microns. Initially, cementless orthopaedic implants are stabilized only by frictional forces at the bone-implant interface. Therefore, other parameters such as the coefficient of friction and the compressive force normal to the interface should be considered as important factors which stabilize the interface along with micromotion. The purpose of this analytical study was to elucidate how the stability at the bone-implant interface is influenced by various factors, namely, motion of the implant, the coefficient of friction, the degree of pres fit, and the modulus of the surrounding cancellous bone in determining the stability of the bone-implant interface. Nonlinear and linear finite element models which simulated the immediate postsurgical condition and the end point of the canine in vivo micromotion experiment, respectively, were used to this end. From the results of the finite element models it was possible to identify the displacement magnitude for which the implant slipped relative to the bone as the motion of the implant was increased incrementally. This was done for combinations of the coefficient of friction, press fit, and Young's modulus of cancellous bone. This was used as an indicator of the limiting implant motion value beyond which bony ingrowth will be inhibited. The stress distribution in the surrounding cancellous bone bed was also obtained from the results of the finite element analyses for different press-fit conditions. The results of the study indicated that under slight press-fit conditions, the implant slipped relative to bone for implant motions as low as 20 microns. For higher degrees of press fit and reasonable values for the coefficient of friction, no slip occurred for implant motions as much as 100 microns. Although higher degrees of press fit were theoretically conducive to better implant stability, the concomitant high stresses in the adjacent cancellous bone will tend to compromise the integrity of the press fit. This was also evident when the results of an analytical model with a lower degree of press fit correlated well with those of the canine in vivo experiment in which a higher press fit was used, suggesting a possibility of achieving a less than desired press fit during the process of implantation. Through this study the importance of factors other than implant motion was emphasized. The results of the study suggest that the limiting value of implant motion that inhibits bone ingrowth might vary with the degree of press fit for reasonable coefficients of friction.

Animals↗

Grip-force responses to unanticipated object loading: load direction reveals body- and gravity-referenced intrinsic task variables.

Humans preserve grasp stability by automatically regulating the grip forces when loads are applied tangentially to the grip surfaces of a manipulandum held in a precision grip. The effects of the direction of the load force in relation to the palm, trunk, and gravity were investigated in blindfolded subjects. Controlled, tangential load-forces were delivered in an unpredictable manner to the grip surface in contact with the index finger either in the distal and proximal directions (away from and toward the palm) or in the ulnar and radial directions (transverse to the palm). The hand was oriented in: (1) a standard position, with the forearm extended horizontally and anteriorly in intermediate pronosupination; (2) an inverted position, reversing the direction of radial and ulnar loads in relation to gravity; and (3) a horizontally rotated position, in which distal loads were directed toward the trunk. The amplitude of the grip-force responses (perpendicular to the grip surface) varied with the direction of load in a manner reflecting frictional anisotropies at the digit-object interface; that is, the subjects automatically scaled the grip responses to provide similar safety margins against frictional slips. For all hand positions, the time from onset of load increase to start of the grip-force increase was shorter for distal loads, which tended to pull the object out of the hand, than for proximal loads. Furthermore, this latency was shorter for loads in the direction of gravity, regardless of hand position. Thus, shorter latencies were observed when frictional forces alone opposed the load, while longer latencies occurred when gravity also opposed the load or when the more proximal parts of the digits and palm were positioned in the path of the load. These latency effects were due to different processing delays in the central nervous system and may reflect the preparation of a default response in certain critical directions. The response to loads in other directions would incur delays required to implement a new frictional scaling and a different muscle activation pattern to counteract the load forces. We conclude that load direction, referenced to gravity and to the hand's geometry, represents intrinsic task variables in the automatic processes that maintain a stable grasp on objects subjected to unpredictable load forces. In contrast, the grip-force safety margin against frictional slips did not vary systematically with respect to these task variables. Instead, the magnitude of the grip-force responses varied across load direction and hand orientation according to frictional differences providing similar safety margins supporting grasp stability.

Adult↗

Artificial composite bone as a model of human trabecular bone: the implant-bone interface.

The use of artificial bones in implant testing has become popular due to their low variability and ready availability. However, friction coefficients, which are critical to load transfer in uncemented implants, have rarely been compared between human and artificial bone, particularly for wet and dry conditions. In this study, the static and dynamic friction coefficients for four commercially used titanium surfaces (polished, Al(2)O(3) blasted, plasma sprayed, beaded) acting on the trabecular component of artificial bones (Sawbones) were compared to those for human trabecular bone. Artificial bones were tested in dry and wet conditions and normal interface stress was varied (0.25, 0.5, 1.0MPa). Friction coefficients were mostly lower for artificial bones than real bone. In particular, static friction coefficients for the dry polished surface were 20% of those for real bone and 42-61% for the dry beaded surface, with statistical significance (alpha<0.05). Less marked differences were observed for dynamic friction coefficients. Significant but non-systematic effects of normal stress or wet/dry condition on friction coefficients were observed within each surface type. These results indicate that the use of artificial bone models for pre-clinical implant testing that rely on interface load transfer with trabecular bone for mechanical integrity can be particularly sensitive to surface finish and lubrication conditions.

Biomechanical Phenomena↗

Stem surface roughness alters creep induced subsidence and 'taper-lock' in a cemented femoral hip prosthesis.

The clinical success of polished tapered stems has been widely reported in numerous long term studies. The mechanical environment that exists for polished tapered stems, however, is not fully understood. In this investigation, a collarless, tapered femoral total hip stem with an unsupported distal tip was evaluated using a 'physiological' three-dimensional (3D) finite element analysis. It was hypothesized that stem-cement interface friction, which alters the magnitude and orientation of the cement mantle stress, would subsequently influence stem 'taper-lock' and viscoelastic relaxation of bone cement stresses. The hypothesis that creep-induced subsidence would result in increases to stem-cement normal (radial) interface stresses was also examined. Utilizing a viscoelastic material model for the bone cement in the analysis, three different stem-cement interface conditions were considered: debonded stem with zero friction coefficient (mu=0) (frictionless), debonded stem with stem-cement interface friction (mu=0.22) ('smooth' or polished) and a completely bonded stem ('rough'). Stem roughness had a profound influence on cement mantle stress, stem subsidence and cement mantle stress relaxation over the 24-h test period. The frictionless and smooth tapered stems generated compressive normal stress at the stem-cement interface creating a mechanical environment indicative of 'taper-lock'. The normal stress increased with decreasing stem-cement interface friction but decreased proximally with time and stem subsidence. Stem subsidence also increased with decreasing stem-cement interface friction. We conclude that polished stems have a greater potential to develop 'taper-lock' fixation than do rough stems. However, subsidence is not an important determinant of the maintenance of 'taper-lock'. Rather subsidence is a function of stem-cement interface friction and bone cement creep.

Aged↗

Langevin model of the temperature and hydration dependence of protein vibrational dynamics.

The modification of internal vibrational modes in a protein due to intraprotein anharmonicity and solvation effects is determined by performing molecular dynamics (MD) simulations of myoglobin, analyzing them using a Langevin model of the vibrational dynamics and comparing the Langevin results to a harmonic, normal mode model of the protein in vacuum. The diagonal and off-diagonal Langevin friction matrix elements, which model the roughness of the vibrational potential energy surfaces, are determined together with the vibrational potentials of mean force from the MD trajectories at 120 K and 300 K in vacuum and in solution. The frictional properties are found to be describable using simple phenomenological functions of the mode frequency, the accessible surface area, and the intraprotein interaction (the displacement vector overlap of any given mode with the other modes in the protein). The frictional damping of a vibrational mode in vacuum is found to be directly proportional to the intraprotein interaction of the mode, whereas in solution, the friction is proportional to the accessible surface area of the mode. In vacuum, the MD frequencies are lower than those of the normal modes, indicating intramolecular anharmonic broadening of the associated potential energy surfaces. Solvation has the opposite effect, increasing the large-amplitude vibrational frequencies relative to in vacuum and thus vibrationally confining the protein atoms. Frictional damping of the low-frequency modes is highly frequency dependent. In contrast to the damping effect of the solvent, the vibrational frequency increase due to solvation is relatively temperature independent, indicating that it is primarily a structural effect. The MD-derived vibrational dynamic structure factor and density of states are well reproduced by a model in which the Langevin friction and potential of mean force parameters are applied to the harmonic normal modes.

Computer Simulation↗

Optimization of arch guided tooth movement by the use of uprighting springs.

One of the most important drawbacks of arch guided tooth movement is the friction between bracket and arch wire. In order to reduce frictional forces the application of an uprighting spring is proposed. The influence of uprighting and derotating moments on frictional forces has been measured with a friction testing assembly. Applying appropriate uprighting moments results in a reduction of friction by 73-89 per cent. Derotating moments have only a minor effect on friction. For clinical purposes, the uprighting moment should be 50 per cent of the tipping moment.

Biomechanical Phenomena↗

Anomalous acoustic reflection on a sliding interface or a shear band.

We study the reflection of an acoustic plane wave from a steadily sliding planar interface with velocity-strengthening friction or a shear band in a confined granular medium. The corresponding acoustic impedance is utterly different from that of the static interface. In particular, the system being open, the energy of an in-plane polarized wave is no longer conserved, the work of the external pulling force being partitioned between frictional dissipation and gain (of either sign) of coherent acoustic energy. Large values of the friction coefficient favor energy gain, while velocity strengthening tends to suppress it. An interface with infinite elastic contrast (one rigid medium) and v-independent (Coulomb) friction exhibits spontaneous acoustic emission, as already shown by Nosonovsky and Adams [Int. J. Eng. Sci. 39, 1257 (2001)]. But this pathology is cured by a moderately large V strengthening of friction, or, for systems with not too large friction coefficients, by any finite elastic contrast. We show that (i) positive gain should be observable for rough-on-flat multicontact interfaces and (ii) a sliding shear band in a granular medium should give rise to sizable reflection, which opens a promising possibility for the detection of shear localization.

Journal Article↗

Active and passive Brownian motion of charged particles in two-dimensional plasma models.

The dynamics of charged Coulomb grains in a plasma is numerically and analytically investigated. Analogous to recent experiments, it is assumed that the grains are trapped in an external parabolic field. Our simulations are based on a Langevin model, where the grain-plasma interaction is realized by a velocity-dependent friction coefficient and a velocity-independent diffusion coefficient. In addition to the ordinary case of positive (passive) friction between grains and plasma, we also discuss the effects of negative (active) friction. The latter case seems particularly interesting, since recent analytical calculations have shown that friction coefficients with negative parts may appear in some models of ion absorption by grains as well as in models of ion-grain scattering. Such negative friction may cause active Brownian motions of the grains. As our computer simulations show, the influence of negative friction leads to the formation of various stationary modes (rotations, oscillations), which, to some extent, can also be estimated analytically.

Journal Article↗

[Biomechanical analysis of arch-guided molar distalization with super-elastic nickel-titanium springs].

The typical characteristics of orthodontic devices and their effectiveness during tooth movement are of major importance for the success of orthodontic treatment and the stability of the result. To investigate this situation, two typical tooth movements were simulated experimentally using an Orthodontic Measurement and Simulation System (OMSS). These were Distalisation of an upper last molar and Distalisation of a molar including fixation of the guiding arch to a distal supporting last molar. The movements were simulated by employing various different NiTi coil compression springs and two standard steel guiding arches with the dimensions 0.016" x 0.022" and 0.017" x 0.025". The six NiTi springs differed significantly in shape and force characteristics. The eccentric application of the orthodontic force system relative to the centre of resistance brings about a tilting of the tube and arch via molar rotation. Although the forces developed by the springs are relatively constant, frictional losses result in variations in the effective orthodontic forces. With progressive distalisation, the average frictional losses varied between 50% and 80% of the spring-generated force, and frictional variations increased. Lower frictional losses were seen with a 0.016" x 0.022" guiding arch as compared with one measuring 0.017" x 0.025". In comparison with distalisation of a last molar, fixation of the arch to a third molar was associated with higher frictional losses. The interaction of the springs with the tube-guiding arch system could be so powerful that frictional losses were detected already during the initial phase of movement, and in extreme cases led to cessation of distalisation. The rate of distalisation was not affected by the forces generated by the springs. For physiological reasons, therefore, springs developing smaller forces should be used preferentially.

Biomechanical Phenomena↗

Reconstruction of the flexor pulley. The effect of the tension and source of the graft in an in vitro dog model.

Flexor pulleys in the hindpaw digits of twenty-eight adult mixed-breed dogs were reconstructed in order to investigate the influence, on the reconstruction, of the source of the autogenous tissue (intrasynovial compared with extrasynovial tendon) and the tension applied during the repair. The ipsilateral peroneus longus tendon was used to reconstruct the A2 pulley with an around-the-bone technique in twenty-one digits; the graft was sutured at a tension of 0.49, 0.98, and 1.96 newtons in seven digits each. The flexor digitorum profundus tendon of an adjacent digit was used to reconstruct the A2 pulley, at a tension of 0.98 newton, in seven additional digits. The contralateral digits were used as controls for all twenty-eight treated digits. The digits were tested in a custom apparatus designed to measure the frictional force generated between the reconstructed pulley and the tendon beneath it. The frictional force did not differ significantly (p > 0.5) among the three groups repaired with peroneus longus tendon; however, the average value was more than five times that produced in the contralateral, control digits. The average frictional forces created by the flexor digitorum profundus grafts were similar to those in the contralateral, control digits. Reconstruction with the flexor digitorum profundus at a tension of 0.98 newton produced significantly less frictional force (p < 0.05) than that produced by the peroneus longus graft at the same tension. This in vitro model of reconstruction of the A2 pulley demonstrated that tendon from an intrasynovial source (the flexor digitorum profundus) produced less frictional resistance to gliding of the tendon than did tendon from an extrasynovial source (the peroneus longus). This result is consistent with previously published findings that intrasynovial tendons may make better grafts than extrasynovial tendons for the reconstruction of gliding flexor tendons because of decreased friction and better healing qualities. Intrasynovial tendons may also make better grafts for the reconstruction of flexor pulleys.

Animals↗

The influence of playing surfaces on the load on the locomotor system and on football and tennis injuries.

The purpose of this paper is to discuss the influence of playing surfaces on the forces and moments acting on the human body and the injuries they may cause for 2 selected sports activities, American football and tennis. The review is based on data from the literature and from our own investigations. A review of the effect of sports surfaces on injuries in American football leads to the conclusion that surfaces with artificial turf produce non-severe injuries more frequently than surfaces with natural grass. However, severe injuries seem to occur as frequently on natural grass as on artificial turf. It has been speculated that the shoe-surface combination which determines the frictional forces is connected with the injury frequency, i.e. the higher the frictional resistance the higher the injury frequency. Tennis surfaces have been shown to influence the occurrence and frequency of tennis injuries dramatically. The injury frequency on 'clay' and 'synthetic sand' is significantly lower than on other selected artificial surfaces. It is speculated that the differences in injury frequency are directly related to the differences in the frictional properties of the surfaces. Surfaces with low frictional resistance are assumed to cause fewer injuries than surfaces with high frictional resistance. In general, it can be concluded that the frictional property of a surface is one of the main factors to be considered when studying the aetiology of acute and/or chronic pain and injury in sports. Compliance or stiffness of surfaces, surprisingly, could not be related to the frequency of injuries on particular playing surfaces. However, it is speculated that compliance properties of surfaces are a factor which must be considered when studying chronic injuries.

Ankle↗

Wear of the acetabular socket. Comparison of polyacetal and polyethylene.

Frictional characteristics of polyacetal (Delrin) sockets and of ultra-high molecular weight polyethylene sockets retrieved in revision after aseptic loosening were compared with measurements of friction in new sockets. Friction in retrieved polyacetal sockets was twice as great as in retrieved polyethylene sockets. We also found that frictional characteristics of polyacetal changed as the material aged in vivo. In contrast, friction in polyethylene sockets remained fairly constant, even though most of them contained bone-cement particles. Friction in polyacetal sockets may be important for the relatively high incidence of socket loosening of the Christiansen prosthesis. Measurements of wear of the polyacetal sockets showed a mean annual dimensional change of 240 mm3, four times greater than that reported for the Charnley polyethylene acetabular prosthesis.

Acetabulum↗