Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Compressive Strength”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84Linked to original sources

[Developments of the theory of skeletal adaptation to mechanical loading].

The primary mechanical function of bone is to provide rigid levers for limbs to act against mechanical loading and gravity, and to remain as light as possible to allow efficient locomotion. There are increasing evidence that mechanical loading is an important, if not the most important, factor influences bone mass and architecture. Many bones are exposed to thousands of repetitive loads every day, which always cause strains. Unusual strain distributions, high strains, and high strain rates seem to be particularly osteogenic. Bone modeling can increase bone strength and mass, bone remodeling can conserve or reduce them, and each can be turned ON or OFF in response to its own threshold range of bone strains. During growth and development, the skeleton optimizes its architecture and strength by (re)modeling to adapt to the largest voluntary loads on bones. The loads come from muscles, not body weight. A new standard of defining osteoporosis might relate bone strength to muscle strength that concerns the osteopenias pathogenesis and its severity, and it would be useful for prevention and cure of osteoporosis.

Aerospace Medicine↗

Adjacent tissues (cartilage, bone) affect the functional integration of engineered calf cartilage in vitro.

OBJECTIVE: An in vitro model was used to test the hypothesis that culture time and adjacent tissue structure and composition affected chondrogenesis and integrative repair in engineered cartilage. METHOD: Engineered constructs made of bovine calf chondrocytes and hyaluronan benzyl ester non-woven mesh were press-fitted into adjacent tissue rings made of articular cartilage (AC), devitalized bone (DB), or vital bone (VB) and cultured in rotating bioreactors for up to 8 weeks. Structure (light and electron microscopy), biomechanical properties (interfacial adhesive strength, construct compressive modulus), biochemical composition (construct glycosaminoglycans (GAG), collagen, and cells), and adjacent tissue diffusivity were assessed. RESULTS: Engineered constructs were comprised predominately of hyaline cartilage, and appeared either closely apposed to adjacent cartilage or functionally interdigitated with adjacent bone due to interfacial deposition of extracellular matrix. An increase in culture time significantly improved construct adhesive strength (P<0.001), modulus (P=0.02), GAG (P=0.04) and cellularity (P<0.001). The type of adjacent tissue significantly affected construct adhesion (P<0.001), modulus (P<0.001), GAG (P<0.001) and collagen (P<0.001). For constructs cultured in rings of cartilage, negative correlations were observed between ring GAG content (log transformed) and construct adhesion (R2=0.66, P<0.005), modulus (R2=0.49, P<0.05) and GAG (R2=0.44, P<0.05). Integrative repair was better for constructs cultured adjacent to bone than cartilage, in association with its solid architectural structure and high GAG content, and best for constructs cultured adjacent to DB, in association with its high diffusivity. CONCLUSIONS: Chondrogenesis and integrative repair in engineered cartilage improved with time and depended on adjacent tissue architecture, composition, and transport properties.

Animals↗

A randomized biomechanical study of zone II human flexor tendon repairs analyzed in an in vitro model.

To study the effect of dorsally placed flexor tendon repairs on human cadaver tendons, we used the Kessler, Strickland, Robertson, and modified Becker techniques. The strengths of the repairs were tested in a previously described human cadaveric curvilinear model. There were statistically significant increases in dorsal versus volar grasping strength with the Kessler repair (38 N vs 33 N) and the Robertson repair (51 N vs 43 N). There were no differences with the locking Strickland and modified Becker repairs. One may infer that the locking techniques are intrinsically tighter and may not be as susceptible to the different forces between the tensile and compressive surfaces of a dynamic flexor tendon.

Cadaver↗

Material changes in osteoporotic human cancellous bone following infiltration with acrylic bone cement for a vertebral cement augmentation.

Bone cement infiltration can be effective at mechanically augmenting osteoporotic vertebrae. While most published literature describes the gain in mechanical strength of augmented vertebrae, we report the first measurements of viscoelastic material changes of cancellous bone due to cement infiltration. We infiltrated cancellous core specimen harvested from osteoporotic cadaveric spines with acrylic bone cement. Bone specimen before and after cement infiltration were subjected to identical quasi-static and relaxation loading in confined and free compression. Testing data were fitted to a linear viscoelastic model of compressible material and the model parameters for cement, native cancellous bone, and cancellous bone infiltrated (composite) with cement were identified. The fitting demonstrated that the linear viscoelastic model presented in this paper accurately describes the mechanical behaviour of cement and bone, before and after infiltration. Although the composite specimen did not completely adopt the properties of bulk bone cement, the stiffening of cancellous bone due to cement infiltration is considerable. The composite was, for example, 8.5 times stiffer than native bone. The local stiffening of cancellous bone in patients may alter the load transfer of the augmented motion segment and may be the cause of subsequent fractures in the vertebrae adjacent to the ones infiltrated with cement. The material model and parameters in this paper, together with an adequate finite-element model, can be helpful to investigate the load shift, the mechanism for subsequent fractures, and filling patterns for ideal cement infiltration.

Bone Density↗

Dynamic relationships of trabecular bone density, architecture, and strength in a computational model of osteopenia.

A computational model was developed to study the effects of short- and long-term periods of disuse osteopenia and repair to elucidate the interrelationships between bone mass, architecture, and strength. The model is one in which the sequence of structural change events is followed in time. This temporal feature contrasts with studies of real trabecular tissue which are necessarily cross-sectional in nature and do not lend themselves to insights into the dynamic nature of the structural changes with time. In the model it was assumed that the stimulus for bone adaptation to mechanical load is the local mechanical strain rate, according to which the trabecular surfaces are differentially formed and resorbed. The effects of mechanical loading and unloading (disuse) on the cancelous bone properties were studied. The bone mass, architecture, and elastic stiffness were shown to be strongly dependent upon the period of the unloading phase, as well as the period of the reloading phase. Mechanical stiffness is demonstrated computationally to be a multivalued function of bone mass, if architecture is not accounted for. The model shows how the same value of trabecular bone mass can be associated with two or more distinct values of biomechanical stiffness. This result is the first explicit demonstration of how bone mass, architecture, and strength are related under dynamical load-bearing conditions. The results explain the empirical observation that bone mass can account for about 65% of the observed variation in bone strength, but that by incorporating measures of bony architecture into the analysis, the predictability is increased to 94%. The computational model may be used to explore the effects of different loading regimes on mass, architecture, and strength, and potentially for assistance in designing both animal and clinical bone loss studies.

Adaptation, Physiological↗

The influence of dispersant concentration on the pore morphology of hydroxyapatite ceramics for bone tissue engineering.

There is a clinical need for synthetic scaffolds that will promote bone regeneration. Important factors include obtaining an optimal porosity and size of interconnecting windows whilst maintaining scaffold mechanical strength, enabling complete penetration of cells and nutrients throughout the scaffold, preventing the formation of necrotic tissue in the centre of the scaffold. To address this we investigated varying slip deflocculation in order to control the resulting porosity, pore size and interconnecting window size whilst maintaining mechanical strength. Hydroxyapatite (HA) porous ceramics were prepared using a modified slip casting process. Rheological measurements of the HA slips were used to identify deflocculation conditions which resulted in changes in the cell and window sizes of the resulting ceramics. Sintered ceramics were characterised by X-ray diffraction (XRD) and scanning electron microscopy (SEM). Pore and window size distribution was determined by SEM. XRD analysis confirmed that the crystal structure remained HA after the sintering process. SEM showed that HA porous ceramics presented a highly interconnected porous network with average pore sizes ranging from 391+/-39 to 495+/-25 microm. The average window size varied from 73+/-5 to 135+/-7 microm. Pore diameters obtained were controllable in the range 200-500 microm. Window sizes were in the range 30-250 microm. The use of dispersant concentration allows pore and window size to be modified whilst maintaining control over porosity demonstrated by a porosity of 85% for seven different dispersant concentrations. The advantage of this approach allows the correlation between the rheological conditions of the slip and the resultant sintered ceramic properties. In particular, optimising the ceramic strength by controlling the agglomeration during the casting process.

Bone Substitutes↗

An in vitro investigation of the effect of the addition of untreated and surface treated silica on the transverse and impact strength of poly(methyl methacrylate) acrylic resin.

Silica is a commonly used filler in dental materials and as a reinforcing agent in industry. The aim of this study was to further investigate the effect of the addition of untreated and a novel surface treated silica on the transverse bend and impact strength of acrylic resin denture base material. It was hypothesized that the silica/resin composite materials would have an improved flexural and impact strength than the conventional heat-cured acrylic resin. Three types of untreated and two of treated silica powder were used in this study. The range of percentages used were 1%, 0.5%, 0.2%, 0.1%. The treated particles were coated with hexamethyldisilazane or dimethyldichloridesilazane. Conventional heat cured acrylic resin was used as a control. The modulus of rupture for all groups of acrylic resin containing silica was significantly lower than for the control. The modulus of elasticity was not significantly greater than the control group. For the impact strength statistical analysis revealed a significant difference between the groups. There was a nonsignificant increase in the impact strength for specimens compared to the control. In conclusion the addition of silica to poly(methyl methacrylate) denture base materials did not produce a significant improvement in the transverse bend or impact strength compared to conventional heat-cured acrylic resin. The incorporation of untreated and surface treated silica cannot be recommended as a method of reinforcement.

Acrylic Resins↗

Contrast dependency of sacadic compression and suppression.

In the occurrence of a saccadic eye movement vision becomes suppressed. Supra-threshold visual stimuli that are briefly presented at that time become perceptually compressed towards the saccade target (saccadic compression) and shifted in saccade direction (saccadic shift). We show that the strength of saccadic compression, like the strength of saccadic suppression, varies with stimulus contrast. Low contrast stimuli lead to stronger compression than high contrast stimuli. The similarity of contrast dependence and time course suggests that saccadic compression is related to saccadic suppression. Because the saccadic shift did not depend on contrast we suggest that shift and compression are different effects.

Adult↗

Compression or tension? The stress distribution in the proximal femur.

BACKGROUND: Questions regarding the distribution of stress in the proximal human femur have never been adequately resolved. Traditionally, by considering the femur in isolation, it has been believed that the effect of body weight on the projecting neck and head places the superior aspect of the neck in tension. A minority view has proposed that this region is in compression because of muscular forces pulling the femur into the pelvis. Little has been done to study stress distributions in the proximal femur. We hypothesise that under physiological loading the majority of the proximal femur is in compression and that the internal trabecular structure functions as an arch, transferring compressive stresses to the femoral shaft. METHODS: To demonstrate the principle, we have developed a 2D finite element model of the femur in which body weight, a representation of the pelvis, and ligamentous forces were included. The regions of higher trabecular bone density in the proximal femur (the principal trabecular systems) were assigned a higher modulus than the surrounding trabecular bone. Two-legged and one-legged stances, the latter including an abductor force, were investigated. RESULTS: The inclusion of ligamentous forces in two-legged stance generated compressive stresses in the proximal femur. The increased modulus in areas of greater structural density focuses the stresses through the arch-like internal structure. Including an abductor muscle force in simulated one-legged stance also produced compression, but with a different distribution. CONCLUSION: This 2D model shows, in principle, that including ligamentous and muscular forces has the effect of generating compressive stresses across most of the proximal femur. The arch-like trabecular structure transmits the compressive loads to the shaft. The greater strength of bone in compression than in tension is then used to advantage. These results support the hypothesis presented. If correct, a better understanding of the stress distribution in the proximal femur may lead to improvements in prosthetic devices and an appreciation of the effects of various surgical procedures affecting load transmission across the hip.

Compressive Strength↗

The effect of pressure during sintering on the strength and the fracture toughness of hydroxyapatite ceramics.

Hydroxyapatite (HA) is known to be biocompatible and osteoconductive, and can be synthesized chemically. The objective of the present study is to clarify the effect of pressure during sintering on the mechanical properties of HA. HA was sintered using a hot press system at a uniaxial pressure ranging from 7.81 to 62.5 MPa at a maximum temperature of 1200 degrees C with a heating rate of 10 degrees C/min. The density of the HA increased with increasing pressure and peaked at the sintering pressure of 31.2 MPa. Four-points bending tests and fracture toughness measurements with indentation method were conducted to clarify the effect of sintering pressure. Bending strength decreased at the pressure > 31.2 MPa. This result indicates that residual stress generated during sintering process became larger with increasing pressure. Fracture toughness were also lower with high density HA.

Ceramics↗

Exercise and muscle strength training and their effect on quality of life in patients with chronic heart failure.

BACKGROUND: There is now evidence that moderate training plays an important role in the treatment of chronic heart failure. No clear instructions exist to date as to how such training programs should be carried out. AIM: to assess the efficiency of a training program including bicycle ergometer training, moderate muscle strength training and the 6-min walk test and their influence on quality of life, anxiety and depression. METHODS AND RESULTS: Patients (67 male, 21 female) underwent a standardized 4-week training program. BASELINE DATA: LVEF=31+/-8%; LVEDD=143+/-59 ml; peak VO(2)=13.9+/-4.6 kg/ml. No adverse side effects could be observed. At discharge LVEF was 37+/-9%, (P=0.001); LVEDD=131+/-44ml (P=0.01); and peak VO(2)=15.4+/-5.0 kg/ml. Quality of life improved significantly in nearly all domains and in summary score. There were no significant changes in anxiety and depression. There is a negative correlation between the initial workload and changes in physical health (r=-0.42, P=0.001) and only a weak correlation between age and positive changes in physical health (r=0.26, P=0.05). CONCLUSIONS: A standardized training program including moderate muscle strength training could be performed safely and demonstrated improvement in clinical parameters and quality of life.

Adult↗

The effect of formulation composition and dissolution parameters on the gel strength of controlled release hydrogel tablets.

The impact of hydrogel polymers and dissolution media on tablet gel strength, Gamma, of controlled release (CR) hydrogel tablets was investigated. CR tablets containing either hydroxypropyl methylcellulose (HPMC), hydroxypropyl cellulose (HPC), or carbomer were formulated with theophylline and Fast Flo lactose, to produce tablets with a polymer content of 8, 15, and 30% w/w. Gamma was measured using a previously reported method. The drug dissolution profiles were similar, irrespective of polymer type or dissolution media (DI water, 0.1 N HCl, and pH 6.8 phosphate buffer), at the same % w/w level of polymer. Gamma, however, showed large and significant differences (p < or = 0.05) between tablets containing different polymers and between different dissolution media. Gamma values were HPMC KI00MP > HPC HXF > carbomer 971P (same % w/w) with absolute Gamma values at 30% w/w in DI water of 6600, 4600, and 1600 ergs/cm3, respectively. Gamma for HPMC based tablets was independent of changes in dissolution media, while the Gamma values for HPC tablets were 18% lower in acid and buffer than in DI water. Of the polymers tested, carbomer based tablets had the lowest Gamma values in all dissolution media and an unexpected 58% lower Gamma in buffer compared with DI water or acid. Gamma provides a quantitative measure of the effect of formulation and dissolution parameter changes on tablet gel layer strength, under in vitro stress conditions that may parallel in vivo tablet performance, but which cannot be deduced from a comparison of dissolution profiles or polymer viscosity.

Chemistry, Pharmaceutical↗

Sintering temperature effects on the in vitro bioactive response of tape cast and sintered bioactive glass-ceramic in Tris buffer.

Tape casting procedures were used to form thin polymeric sheets (100 microm thickness) loaded with bioactive glass particulate. Blanks were punched from the sheets, stacked, laminated, and heated in air to 500 degrees C to remove the organic phase. The resulting bioactive glass discs were sintered at 800 degrees C, 900 degrees C, or 1000 degrees C. Because the material is built up in layers and can be machined in the green state, such a processing technique can be used to form complex-shaped materials. The in vitro bioactivity of the tape cast sintered (TCS) bioactive glass-ceramic discs was then assessed in Tris buffer. The sample surface area to volume buffer (SA/V) ratio was approximately 0.1 cm(2)/mL. Tape cast bioactive glass-ceramic sintered at 900 degrees C and 1000 degrees C formed crystalline hydroxyapatite layers after 24 h in Tris buffer as indicated by FTIR, SEM, and EDS analysis. Decreasing the SA/V ratio to 0.013 cm(2)/mL allowed for the formation of crystalline hydroxyapatite layers on the surface of 800C TCS bioactive glass-ceramic. Given the dependence of the bioactive response as a function of the processing schedule and SA/V ratio, it may be possible to tailor the response to that desired in vivo or in vitro for tissue engineering studies. Biaxial flexural strength of TCS bioactive glass-ceramic increased with increasing sintering temperature. Strength of samples sintered at 1000 degrees C for 3 h increased from 87 to 120 MPa after 2 weeks' immersion in Tris buffer.

Biocompatible Materials↗

Comparison of the mechanical destructive force in the small intestine of dog and human.

The purpose of this study was to evaluate the destructive force that oral solid dosage forms receive in the small intestine of dogs and humans. Information on the mechanical destructive forces of the gastrointestinal tract (GI) helps formulation design research in the following way: (1) to improve the predictability of the dissolution test since in vivo drug release is affected by not only agitation intensity but also mechanical stress; (2) to design safe and robust products by avoiding dose-dumping or unintended drug release at an inadequate site; (3) to better understand the species difference in bioavailability by comparing the destructive forces against dosage forms in the GI of dogs with those of humans. "Destructive force Dependent Release System" (DDRS) was developed to measure the mechanical destructive forces of the GI tract by using highly hydrophobic Teflon powder. In a DDRS, a marker drug contained in the core tablet is released only when the DDRS receives a force larger than its pre-determined crushing strength. DDRS-Small Intestine (DDRS-SI), a modified DDRS, was prepared for targeting the small intestine. DDRS-SI was encapsulated in starch capsules (Capill) and then the capsules were coated with an enteric film (DDRS-SI-Ecap). The capsules were administered to six dogs and nine human volunteers. Both dogs and human volunteers crushed a DDRS-SI having a crushing strength of 1.2 N. Therefore, these controlled-release formulations should withstand a destructive force of 1.2 N when they pass through the small intestine.

Administration, Oral↗

Preparation and characterization of macroporous chitosan/wollastonite composite scaffolds for tissue engineering.

Chitosan/wollastonite composite scaffolds were prepared by a thermally induced phase separation method. The microstructure, mechanical performance and in vitro bioactivity of the composite scaffolds were investigated. The composite scaffolds were macroporous and wollastonite particles were dispersed uniformly on the surface of the pore walls. Scanning electron microscope images of the composite scaffolds demonstrated that the scaffolds had interconnected pores with diameters from 60 to 200 microm. Both the pore size and structure were affected by freezing temperature. The mechanical performance of the composite scaffolds was improved compared to that of pure chitosan scaffolds. The in vitro bioactivity of the scaffolds was evaluated by soaking samples in simulated body fluid and the apatite layer was observed on the surface of the pore walls of the composite scaffolds. Our results suggest that the incorporation of wollastonite into chitosan could enhance both the mechanical strength and the in vitro bioactivity of the resultant composite. The macroporous chitosan/wollastonite scaffolds may be a potential candidate for application in tissue engineering.

Biocompatible Materials↗

Comparative physico-mechanical characterization of new hybrid restorative materials with conventional glass-ionomer and resin composite restorative materials.

The recently developed hybrid restorative materials contain the essential components of conventional glass ionomers and light-cured resins. The objective of this study was to determine several physical and mechanical properties of eight such materials in comparison with two conventional glass ionomers, one micro-filled, and one ultrafine compact-filled resin composite. The two resin composites and two of the three polyacid-modified resin composites could be polished to a higher gloss than the conventional as well as the resin-modified glass ionomers. After abrasion, surface roughness increased for all materials, but not at the same extent, being the least for the conventional resin composites and one polyacid-modified resin composite, Dyract. In contrast to the later resin composites, of which the surface roughness is principally determined by the presence of protruding filler particles above the resin matrix, roughness of conventional and resin-modified glass ionomers results from both protruding filler particles and intruding porosities. The mean particle size of the hybrid restorative materials fell between the smaller mean particle size of the resin composites and the larger one of the conventional glass ionomers. The micro-hardness and Young's modulus values varied substantially among all eight hybrid restorative materials. For all the resin-modified glass-ionomer restorative materials, the Young's modulus reached a maximum value one month after mixing and remained relatively stable thereafter. The Young's modulus of the conventional and the polyacid-modified resin composites decreased slightly after one month. The conventional glass-ionomer materials undoubtedly set the slowest, since their Young's modulus took six months to reach its maximum. The flexural fatigue limit of the hybrid restorative materials is comparable with that of the micro-filled composite. From this investigation, it can be concluded that the physico-mechanical properties vary widely among the eight hybrid restorative materials, indicating that these materials probably have yet to achieve their optimum properties. Their mechanical strength is inadequate for use in stress-bearing areas, and their appearance keeps them from use where esthetics is a primary concern.

Acrylic Resins↗

An inclusion technique for marking dentures.

The importance of placing identification markers in dentures is well documented and this paper describes a simple and inexpensive technique for doing it. Twenty marked upper acrylic simulated dentures and 20 controls (unlabelled) were constructed in a standardized mould. Clear laminated labels were produced in a P-touch 300 electronic lettering system and contained both the patient's identification number and suffix ZA (international code for South Africa). The markings were both clear and aesthetically acceptable. Strength tests were carried out to establish the effect of the mark with the result that no significant difference (p70.05) was demonstrated. The routine marking of all dentures by this method is advocated.

Acrylic Resins↗

Roller compaction and tabletting of St. John's wort plant dry extract using a gap width and force controlled roller compactor. I. Granulation and tabletting of eight different extract batches.

The purpose of this study was to investigate the influence of roller compaction parameters on granule and tablet quality of a dry herbal extract from St. John's wort (Hypericum perforatum L.), which is widely used in the treatment of mild to moderate depressive disorders. Eight different extract batches were blended with 0.5, 2, and 5% of magnesium stearate and were compacted at different compaction forces using a gap width and force controlled roller compactor. The ribbon formed was milled into granules having mean particle sizes up to 700 microns. The roller compaction of the extracts decreased significantly the angle of repose from about 45 to 32 degrees and the Hausner ratio from about 1.2 to 1.1. Tabletting of granulated extract instead of extract powder effectively reduced not only dust and feeding problems during the tabletting process but also prevented capping. The incorporation of 2 and 5% of magnesium stearate into the roller compacted extract reduced significantly the sticking of the dry herbal extracts to the punch faces without affecting the crushing strength of the tablets. Tablets containing granulated extracts exhibited a 3-fold lower disintegration time of about 12 min compared to tablets containing extract powder. Dissolution studies revealed that hyperforin, hypericin, and rutin were more rapidly released from tablets containing granulated extract. Therefore, roller compaction leveled out the differences in technological properties between the eight dry herbal extracts and compression of granulated extract significantly improved tablet quality.

Compressive Strength↗