Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Compression Algorithms”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84Linked to original sources

Effect of filler content on mechanical and dynamic mechanical properties of particulate biphasic calcium phosphate--polylactide composites.

A bioabsorbable self-reinforced polylactide/biphasic calcium phosphate (BCP) composite is being developed for fracture fixation plates. One manufacturing route is to produce preimpregnated sheets by pulling polylactide (PLA) fibres through a suspension of BCP filler in a PLA solution and compression moulding the prepreg to the desired shape. To aid understanding of the process, interactions between the matrix and filler were investigated. Composite films containing 0-0.25 volume fraction filler, produced by solvent casting, were analysed using SEM, tensile testing and dynamic mechanical analysis (DMA). Homogeneous films could be made, although some particle agglomeration was seen at higher filler volume fractions. As the filler content increased, the failure strain decreased due to a reduction in the amount of ductile polymer present and the ultimate tensile strength (UTS) decreased because of agglomeration and void formation at higher filler content. The matrix glass transition temperature increased due to polymer chain adsorption and immobilization onto the BCP particles. Complex damping mechanisms, such as particle-particle agglomeration, may exist at the higher BCP volume fractions.

Algorithms↗

Temporal analysis of tissue displacement induced by a transient ultrasound radiation force.

One of the stress sources that can be used in dynamic elastography imaging methods is the acoustic radiation force. However, displacements of the medium induced by this stress field are generally not fully understood in terms of spatial distribution and temporal evolution. A model has been developed based on the elastodynamic Green's function describing the different acoustic waves generated by focused ultrasound. The function is composed of three terms: two far-field terms, which correspond to a purely longitudinal compression wave and a purely transverse shear wave, and a coupling near-field term which has a longitudinal component and a transverse component. For propagation distances in the shear wavelength range, the predominant term is the near field term. The displacement duration corresponds to the propagation duration of the shear wave between the farthest source point and the observation point. This time therefore depends on the source size and the local shear modulus of the tissue. Evolution of the displacement/time curve profile, which is directly linked to spatial and temporal source profiles, is computed at different radial distances, for different durations of force applications and different shear elastic coefficients. Experimental results performed with an optical interferometric method in a homogeneous tissue-mimicking phantom agreed with the theoretical profiles.

Acoustics↗

Nonlinear prediction for Gaussian mixture image models.

Prediction is an essential operation in many image processing applications, such as object detection and image and video compression. When the images are modeled as Gaussian, the optimal predictor is linear and easy to obtain. However, image texture and clutter are often non-Gaussian, and, in such cases, optimal predictors are difficult to obtain. In this paper, we derive an optimal predictor for an important class of non-Gaussian image models, the block-based multivariate Gaussian mixture model. This predictor has a special nonlinear structure: it is a linear combination of the neighboring pixels, but the combination coefficients are also functions of the neighboring pixels, not constants. The efficacy of this predictor is demonstrated in object detection experiments where the prediction error image is used to identify "hidden" objects. Experimental results indicate that when the background texture is nonlinear, i.e., with fast-switching gray-level patches, it performs significantly better than the optimal linear predictor.

Algorithms↗

Interspecies variation of compressive biomechanical properties of the meniscus.

Various animal models have been used to investigate the normal and reparative properties of the knee meniscus. Yet, only limited data on meniscal biomechanical properties of various animals are available. It was therefore the objective of this study to compare measurements of meniscal biomechanical properties between six species: human, bovine, monkey, canine, sheep, and porcine. Uniaxial confined compression tests were conducted on 1-mm-thick, 4-mm-diameter meniscal discs, and the viscoelastic creep deformation was obtained. Two biomechanical parameters, the aggregate modulus (HA) and permeability (K), were found by implementing the linear biphasic theory and a newly developed nonlinear regression scheme. A one-way analysis of variance was conducted along with Student-Newman-Keuls comparison tests to assess the differences in these parameters among the species. Sheep menisci exhibited HA and K values most similar to human menisci. The water content of each specimen was also measured and correlated significantly with K. The interspecies variations found in material properties of the knee meniscus indicate the need for caution in extrapolating data on the biomechanical behavior of the human meniscus from animal models.

Adult↗

ECG coding by wavelet-based linear prediction.

This paper presents a novel coding scheme for electrocardiogram (ECG). Following beat delineation, the periods of the beats are normalized by multirate processing. After amplitude normalization, discrete wavelet transform is applied to each beat. Due to the period and amplitude normalization, the wavelet transform coefficients bear a high correlation across beats at identical locations. To increase the compression ratio, the residual sequence obtained after linear prediction of the significant wavelet coefficients is transmitted to the decoder. The difference between the actual period and the mean beat period, and that between the actual scale factor and the average amplitude scale factor are also transmitted for each beat. At the decoder, the inverse wavelet transform is computed from the reconstructed wavelet transform coefficients. The original amplitude and period of each beat are then recovered. The approximation achieved, at an average rate of 180 b/s, is of high quality. We have evaluated the normalized maximum amplitude error and its position in each cycle, in addition to the normalized root mean square error. The significant feature of the proposed technique is that, while the error is nearly uniform throughout the cycle, the diagnostically crucial QRS region is kept free of maximal reconstruction error.

Algorithms↗

Factors influencing the accuracy of biomechanical breast models.

Recently it has been suggested that finite element methods could be used to predict breast deformations in a number of applications, including comparison of multimodality images, validation of image registration and image guided interventions. Unfortunately knowledge of the mechanical properties of breast tissues is limited. This study evaluated the accuracy with which biomechanical breast models based on finite element methods can predict the displacements of tissue within the breast in the practical clinical situation where the boundaries of the organ might be known reasonably accurately but there is some uncertainty on the mechanical properties of the tissue. For two datasets, we investigate the influence of tissue elasticity values, Poisson's ratios, boundary conditions, finite element solvers and mesh resolutions. Magnetic resonance images were acquired before and after compressing each volunteer's breast by about 20%. Surface displacement boundary conditions were derived from a three-dimensional nonrigid image registration. Six linear and three nonlinear elastic material models with and without skin were tested. These were compared to hyperelastic models. The accuracy of the models was evaluated by assessing the ability of the model to predict the location of 12 corresponding anatomical landmarks. The accuracy was most sensitive to the Poisson's ratio and the boundary condition. Best results were achieved for accurate boundary conditions, appropriate Poisson's ratios and models where fibroglandular tissue was at most four times stiffer than fatty tissue. These configurations reduced the mean (maximum) distance of the landmarks from 6.6 mm (12.4 mm) to 2.1 mm (3.4 mm) averaged over all experiments.

Algorithms↗

A new radiographic method for evaluating the degree of sliding in devices used in hip-fracture surgery.

PURPOSE: To find a practical method for estimating the degree of sliding that occurs in screw-plate devices used in hip-fracture surgery. Greater understanding of the sliding mechanisms in different fracture types should improve surgical technique and reduce the failure rate. METHODS AND RESULTS: In dynamic screw-plate devices, the lag screw slides inside the barrel of the plate. A recent innovation allows the barrel-plate to slide inside a side-plate, thus making possible a combined fracture compression along the neck and the shaft of femur. The lengths of the different parts and the angle of a device in vivo, measured on a radiograph, depend on the position of the femur relative to the photographic film and the roentgen source. We obtained these measurements with a ruler and a protractor from sequential a.p. radiographs of the hip and implemented them in a special computerized program that used the principles of the scaled orthographic and the central projection models. These calculations provided the correct amount of sliding by the lag screw and by the barrel-plate within the side-plate. CONCLUSION: The method presented here can establish the real degree of sliding in screw-plate devices from standard a.p. radiographs independently of the position of the hip.

Algorithms↗

A comparison of the transient hyperemic response test and the static autoregulation test to assess graded impairment in cerebral autoregulation during propofol, desflurane, and nitrous oxide anesthesia.

UNLABELLED: The transient hyperemic response (THR) test has been used to assess cerebral autoregulation in anesthesia and intensive care. To date it has not been compared with the static autoregulation test for assessing graded changes in cerebral autoregulation. We compared the two tests during propofol, desflurane, and nitrous oxide anesthesia. Seven subjects were studied. For the THR test, changes in the middle artery blood flow velocity were assessed during and after a 10-s compression of the ipsilateral common carotid artery. Two indices of autoregulation--THR ratio (THRR) and strength of autoregulation (SA)--were calculated. For the test of static autoregulation, changes in the middle cerebral artery flow velocity after a phenylephrine-induces increase in mean arterial pressure were assessed, and the static rate of regulation (sROR) was calculated. The tests were performed before induction and after equilibrium at 0.5 minimum alveolar anesthetic concentration (MAC) and then at 1.5 MAC of desflurane. THRR, SA and sROR decreased significantly (P < 0.001) at 0.5 MAC and then at 1.5 MAC desflurane. CHanges in THRR and SA reflected the changes in sROR with a sensitivity of 100%. IMPLICATIONS: When compared with the established test of static autoregulation, the transient hyperemic response test provides a valid method for assessing graded impairment in cerebral autoregulation.

Adolescent↗

Comparison of muscle forces and joint load from an optimization and EMG assisted lumbar spine model: towards development of a hybrid approach.

The purpose of this study was to determine whether the same estimates of individual muscle and L4/L5 lumbar joint compressive forces result from an optimization (OPT) compared to an electromyography (EMG) assisted approach for solving the inderminate moment equilibrium equations in the same anatomical model. Four male subjects performed near maximum, isometric, ramp efforts in trunk flexion, extension and lateral bending in a testing apparatus. The EMG approach was sensitive to subject and trial differences in the magnitudes of individual muscle forces needed to produce the same reaction moment. In contrast, the OPT method converged on a similar estimate of muscle forces for all subjects and trials producing the same moment. The OPT method predicted lower L4/L5 joint compression values, on average, by 32, 43 and 23% in trunk extension, flexion and lateral bending, respectively, because, unlike the EMG method, it could not predict co-contraction of anatomically antagonistic muscles. We incorporated the OPT method's advantage of forcing an equilibrium in the reaction moments into the EMG method in a new approach we have called 'EMG assisted optimization' (EMGAO). Muscle force estimates from the EMG and EMGAO methods differed from those from the OPT method, on average, by 123% (RMS) for flexion and extension and by 218% for lateral bends. Data from the two approaches result in different conclusions about spine mechanics. We have more confidence in the EMG assisted methods because they respond to variation in muscle synergy and co-contraction patterns commonly observed in different trials and subjects for the same reaction moments.

Adult↗

Small intrapulmonary artery lung prototypes. Mathematical modeling of gas transfer.

Two diffusion models have been developed to analyze gas transfer data previously measured in an intravascular artificial lung consisting of a central gas supply catheter from which are tethered a large number of blind-ended microporous fibers of equal length. A convective-diffusion model (CD) describes the countercurrent transfer of a binary gas pair when gas is supplied at constant pressure conditions, and a well mixed (WM) cycled pressure model predicts transfer when the gas supply pressure is time cycled between compression and vacuum conditions. Regression of gas to gas and liquid to gas excretion data with the CD model resulted in estimates of the liquid phase mass transfer coefficient kAI. Because these values were intermediate between the kAI expected for flow parallel to a cylinder and for flow normal to a cylinder, gas transfer was influenced by both the tethered region of the fiber that was nearly perpendicular to the axis of the test section and the free end of the fiber that rested along the wall of the test section. With a time cycled gas supply pressure, the enhanced carbon dioxide and oxygen excretion predicted by the WM model was similar to the data, but a loss in transfer efficiency with fiber length was not accounted for by the theory.

Algorithms↗

Modeling visual attention's modulatory aftereffects on visual sensitivity and quality evaluation.

With the fast development of visual noise-shaping related applications (visual compression, error resilience, watermarking, encryption, and display), there is an increasingly significant demand on incorporating perceptual characteristics into these applications for improved performance. In this paper, a very important mechanism of the human brain, visual attention, is introduced for visual sensitivity and visual quality evaluation. Based upon the analysis, a new numerical measure for visual attention's modulatory aftereffects, perceptual quality significance map (PQSM), is proposed. To a certain extent, the PQSM reflects the processing ability of the human brain on local visual contents statistically. The PQSM is generated with the integration of local perceptual stimuli from color contrast, texture contrast, motion, as well as cognitive features (skin color and face in this study). Experimental results with subjective viewing demonstrate the performance improvement on two PQSM-modulated visual sensitivity models and two PQSM-based visual quality metrics.

Algorithms↗

Optimal nonlinear codes for the perception of natural colours.

We discuss how visual nonlinearity can be optimized for the precise representation of environmental inputs. Such optimization leads to neural signals with a compressively nonlinear input-output function the gradient of which is matched to the cube root of the probability density function (PDF) of the environmental input values (and not to the PDF directly as in histogram equalization). Comparisons between theory and psychophysical and electrophysiological data are roughly consistent with the idea that parvocellular (P) cells are optimized for precision representation of colour: their contrast-response functions span a range appropriately matched to the environmental distribution of natural colours along each dimension of colour space. Thus P cell codes for colour may have been selected to minimize error in the perceptual estimation of stimulus parameters for natural colours. But magnocellular (M) cells have a much stronger than expected saturating nonlinearity; this supports the view that the function of M cells is mainly to detect boundaries rather than to specify contrast or lightness.

Algorithms↗

A new formalism for the quantification of tissue perfusion by the destruction-replenishment method in contrast ultrasound imaging.

A new formalism is presented for the destruction-replenishment perfusion quantification approach at low mechanical index. On the basis of physical considerations, best-fit methods should be applied using perfusion functions with S-shape characteristics. These functions are first described for the case of a geometry with a single flow velocity, then extended to the case of vascular beds with blood vessels having multiple flow velocity values and directions. The principles guiding the analysis are, on one hand, a linearization of video echo signals to overcome the log-compression of the imaging instrument, and, on the other hand, the spatial distribution of the transmit-receive ultrasound beam in the elevation direction. An in vitro model also is described; it was used to confirm experimentally the validity of the approach using a commercial contrast agent. The approach was implemented in the form of a computer program, taking as input a sequence of contrast-specific images, as well as parameters related to the ultrasound imaging equipment used. The generated output is either flow-parameter values computed in regions-of-interest, or parametric flow-images (e.g., mean velocity, mean transit time, mean flow, flow variance, or skewness). This approach thus establishes a base for extracting information about the morphology of vascular beds in vivo, and could allow absolute quantification provided that appropriate instrument calibration is implemented.

Algorithms↗

A new correction technique for measuring respiratory impedance through an endotracheal tube.

Measurement of respiratory impedance (Zrs) in intubated patients requires corrections for flow-dependent resistance and air compression inside the endotracheal tube (ET). The purpose of this study was to test a new correction technique for these effects. We therefore studied 110 patients in two conditions: breathing normally (C1), or breathing through an ET placed at the mouth (C2). In C1, we measured pressure and flow signals at the mouth, and in C2, at the ET inlet, during application of a pseudorandom forced excitation (4-32 Hz). In C1, respiratory impedance was calculated directly as Z1. In C2, pressure data were first corrected for the flow-dependent resistance of the ET, and respiratory impedance was then corrected both for gas compression inside the set-up and ET inertance (impedance Z2). Strong linear relationships were found between the reference and corrected estimates of the resistance at 6 Hz, the frequency dependence of resistance and the resonant frequency. The mean normalized distance between Z1 and Z2 observed in the patients over the 4-32 Hz frequency range was about 14% for resistance and 12% for reactance (-9% and -4%, respectively, when considering the algebraic value of the distance). This slight underestimation of both components of impedance might be due to an overcorrection of pressure for the flow-dependent resistance of the ET. We conclude that, in intubated patients, newly tested corrections for the mechanical contribution of the endotracheal tube may yield a fair estimate of respiratory impedance when pressure is measured at the inlet of the endotracheal tube.

Airway Resistance↗

LF-NMR and multivariate data analysis: compression of data to classify hydrogel contact lenses.

Hydrogel contact lenses swollen in viscoelastic artificial tears solution have been studied, measuring transversal relaxation times of water molecules using LF-NMR techniques. Data were processed by classical multiexponential fitting, by principal component analysis and by SLICING, a multi-way analysis method. The reason for using multivariate data analysis was not to obtain a better fitting, but rather more effective data description. The single-sample relaxation curves were projected in a space spanned by the loading curves, and in this space it was simpler to compare data. In particular, it contributed to the description of the variability of motion characteristics of the water molecule 'families' contained in the studied samples. Applying multivariate techniques, we were able to group lenses with different Equilibrium Water Content (EWC) and with the same water content but different compositions. Accordingly, we were able to point out that, if the lenses are swollen first in physiological solution and then in viscoelastic artificial tears solution, hydration characteristics remained unchanged in all the studied samples, except for 38% EWC lenses.

Algorithms↗

Ultrasonic evaluation of residual stresses in flat glass tempering by an original double interferometric detection.

In industrial thermal tempering of glass, the knowledge of the homogeneity of compressive residual stress field on the glass product is fundamental to guarantee the quality of the tempered glass product. In this paper, we use the acoustoelasticity phenomenon in order to estimate the residual stress distribution by using acoustic surface wave. We present an experimental setup based on a double interferometric detection in which an aspheric lens is associated with a beam splitter and a YAG laser whose power is 100 mW. This relative high power enables us to carry out measurements on surface flat glass although optical reflection coefficient is typically weak (< 10%). Using these two points of detection, the evolution of relative surface wave velocity is obtained with a good accuracy. At last, a comparison between the numerical modeling and experimental results shows the potentiality of an ultrasonic method to estimate stress distribution in flat glass tempering.

Algorithms↗

Clinical evaluation of a full-digital in-the-ear hearing instrument.

In this study we measured the efficacy of a digital hearing aid with compression and noise reduction in a well-controlled clinical field trial in two independent centres. The experiments focused on a number of aspects of the application of the digital hearing aids. The study combines a field test of 2x4 weeks with laboratory experiments. We used objective measurements (speech perception tests in background noise, loudness scaling) and subjective assessments (questionnaires). The measurements were performed before and after the field test. The questionnaires were collected after each field test. The results of the digital hearing aids were compared to the results of similar tests with newly fitted analogue reference aids. The study involved 27 sensorineural hearing-impaired subjects, wearing new hearing aids. They comprised a representative sample of in-the-ear users. We used a crossover design in which the subjects used successively digital hearing aids and analogue reference aids in a randomized order. On average, the subjective data are more positive than the objective data. In the end, 20 out of 27 subjects had an overall preference for the digital hearing aid. The financial implications were not taken into consideration. However, objective data do not support this strong subjective preference. A reason could be that the method of analysis (short sentences in a short-duration background noise) is not suited for the digital hearing aid; the testing procedure does not allow the noise-reduction algorithm to adapt to the background noise. There was a striking difference between the results for the two centres. This difference can, to at least a certain extent, be attributed to the timing of speech relative to the background noise in the objective tests. This illustrates that the test conditions are critical in modern non-linear signal-processing hearing aids with long time constants. New evaluation techniques should be developed for this new generation of active non-linear hearing aids.

Adult↗

Airway resistance due to alveolar gas compression measured by barometric plethysmography in mice.

We developed a method for measuring airway resistance (R(aw)) in mice that does not require a measurement of airway flow. An analysis of R(aw) induced by alveolar gas compression showed the following relationship for an animal breathing spontaneously in a closed box: R(aw) = A(bt)V(b)/[V(t) (V(e) + 0.5V(t))]. Here A(bt) is the area under the box pressure-time curve during inspiration or expiration, V(b) is box volume, V(t) is tidal volume, and V(e) is functional residual capacity (FRC). In anesthetized and conscious unrestrained mice, from experiments with both room temperature box air and body temperature humidified box air, the contributions of gas compression to the box pressure amplitude were 15 and 31% of those due to the temperature-humidity difference between box and alveolar gas. We corrected the measured A(bt) and V(t) for temperature-humidity and gas compression effects, respectively, using a sinusoidal analysis. In anesthetized mice, R(aw) averaged 4.3 cmH(2)O.ml(-1).s, fourfold greater than pulmonary resistance measured by conventional methods. In conscious mice with an assumed FRC equal to that measured in the anesthetized mice, the corrected R(aw) at room temperature averaged 1.9 cmH(2)O.ml(-1).s. In both conscious mice and anesthetized mice, exposure to aerosolized methacholine with room temperature box air significantly increased R(aw) by around eightfold. Here we assumed that in the conscious mice both V(t) and FRC remained constant. In both conscious and anesthetized mice, body temperature humidified box air reduced the methacholine-induced increase in R(aw) observed at room temperature. The method using the increase in A(bt) with bronchoconstriction provides a conservative estimate for the increase in R(aw) in conscious mice.

Airway Resistance↗