Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ARTIFICIAL LIMBS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84Linked to original sources

Clinical investigation of the pressure and shear stress on the trans-tibial stump with a prosthesis.

A system for measuring pressures and bi-axial shear stresses at the body support interfaces has been developed. This system has been used, in five unilateral trans-tibial amputees, to investigate the stresses at multiple points on the residual limb and prosthetic socket interface during standing and walking. The subjects investigated regularly used a patellar-tendon-bearing socket. The maximum peak pressure at the measured points was 320 kPa over the popliteal area during walking. The maximum shear stress was 61 kPa over the medial tibia area. Variable wave-forms of stress during walking were observed at the different measured points. The influence of the angular alignment on the stresses was investigated on one subject. It was found that a miss-alignment of +/- 8 degrees produced a change in peak longitudinal shear stress of between 8% and 11.5%.

Adult↗

A comparison of energy expenditure by a high level trans-femoral amputee using the Intelligent Prosthesis and conventionally damped prosthetic limbs.

Comparisons were made between the Intelligent Prosthesis (IP), Mauch and pneumatic swing phase control damping systems on the same prosthesis worn by a high level trans-femoral amputee. Speeds self selected by corridor walking (4.4-5.5 kmh-1) proved not to be sustainable for treadmill walking. Comfortable speeds were attained when the subject walked on a treadmill at 2.0, 2.6 and 3.2 kmh-1 in two tests for each prosthesis type. Oxygen uptake (VO2), cadence and heart rate were measured over 5 minute walks interspersed with rest periods. Spearman's correlation was used to test for differences between prosthesis types at each speed. At the two slower speeds no significant difference was found, but at the higher speed of 3.2 kmh-1, the IP was associated with a significantly lower VO2 (p < 0.05). A two way analysis of variance with replication (ANOVA) demonstrated a significant difference between VO2 for different limb types (p = 0.015). A square law function was fitted to the mean VO2 for each prosthesis type by the method of least squares regression. ANOVA demonstrated a significant difference between velocity coefficients for the different prosthesis types (p < 0.05). Cadence was almost constant during the period of each walk, varying by 1 step min-1 at most. However the test-retest differences in cadence were considerable. It is concluded that there was little difference in energy expenditure between prosthesis types at slower speeds, but at higher speeds (==> 3.2km h-1) the IP gave a lower oxygen uptake by about 10%.

Adult↗

Fractures in lower limbs with prior amputation. A study of ninety cases.

Eighty-five lower-limb amputees with ninety subsequent fractures of the residual limb were studied retrospectively. Most of the fractures were managed by non-operative methods, with the exception of unstable intertrochanteric fractures and displaced fractures of the femoral neck. Indications for operative and non-operative treatment in below-the-knee and above-the-knee amputees are outlined. No indication was found for reamputation through the fracture site. Before fracture, all amputees used a prosthesis. After healing of the fracture, 97 per cent of the patients with amputation below the knee and 82 per cent of those with amputation above the knee resumed use of a prosthesis.

Adolescent↗

Clinical field follow-up of high density polyethylene (HDPE)-Jaipur prosthetic technology for trans-tibial amputees.

The purpose of this study was to examine the outcome of the application of the High Density Polyethylene (HDPE)-Jaipur prosthetic construction in fitting trans-tibial amputees in a number of projects in the developing world. Projects in Honduras, Uganda and India were visited. Three hundred and twenty (320) patients had been provided with a HDPE-Jaipur prosthesis and of these 172 were seen for a technical and clinical follow-up after a median of 35 months. More than half the amputations were due to trauma, the remainder to disease. Fabrication and fitting in the three projects was carried out by individuals who had undertaken a twice week training course provided by Bhagwan Mahaveer Viklang Sahayata Samiti limb centre in Jaipur. The individuals involved had limited background training in prosthetics. Craftsmanship and fit were assessed as being poor in 56% of cases. The technical quality of the Jaipur foot was considered acceptable as its performance was better than previously observed results. Although there was patient satisfaction of 85% and compliance of 94% the HDPE-Jaipur trans-tibial system was not considered acceptable as 49% reported walking distances less than 1km and 36% discomfort. The major inadequacy in outcome relates to the use for fabrication and fitting of individuals with inadequate education and training.

Adolescent↗

Prosthetic use: correlation of clinic team and ergonomic laboratory in predicting its success.

A group of 92 patients with lower limb amputations were evaluated in an effort to determine whether an appropriate clinical decision to prescribe a prosthesis could be made without using elaborate evaluation testing. The assessments were made independently by a clinic team and by an ergonomic laboratory, each applying its own criteria for predicting successful prosthetic use. The high correlation between the two areas indicated that the ergonomic laboratory made no additional contribution toward the decision to supply a patient who had no complicating features with a prosthesis. Nineteen patients had significant ST depressions during exercise testing and of these, nine died within one year. Two patients with no ST segment depressions died within one year.

Adult↗

Mechanical properties of shock-absorbing pylons used in transtibial prostheses.

Prosthetic manufacturers have developed shock-absorbing pylons to attenuate the transient forces of foot-ground contact in order to supplement the residual capacity of lower limb amputees. The purpose of this study was to measure the elastic and damping properties of two frequently prescribed pylons (the ICON Shock Pylon and the Mercury TT Pyramid Pylon) at frequencies enveloping those observed during gait using pseudo-static compressive and dynamic cyclic testing methods. Results showed that the spring constants were linear functions of deformation (ranging from 74 to 110 N/mm and 91 to 157 N/mm for the ICON and the TT Pylons, respectively) while the damping force was a function of the square root of velocity combined with a coulomb element (1.6x0.5 + 21 and 7.4x0.5 + 102 N for the ICON and the TT Pylon, respectively).

Artificial Limbs↗

Speed-dependent variations of lower-limb joint angles during walking. A graphic computerized method showing individual patterns.

A method for obtaining a synthetic representation of the joint angle time-courses at different walking velocities is presented, based on a computerized procedure. Hip, knee and ankle joint angles are measured by electrogoniometric devices and checked on line for their reliability. One stride only for each walking speed is selected as representative of the adopted cadence. For each joint a tridimensional representation of angle time-course versus stride frequency or versus gait speed is performed so that speed-dependent variations can be analyzed. Ten normal (seven males and three females) and three prosthetized subjects have been tested by this method. In normal as well as in pathological subjects individual features could be easily detected and the method proved to be useful for a functional gait evaluation.

Adult↗

Amputation for reflex sympathetic dystrophy.

We have reviewed 28 patients with reflex sympathetic dystrophy (RSD) who had 34 amputations in 31 limbs. The amputations had been performed for untenable pain (5), recurrent infection (14) or to improve residual function (15). Only two patients were relieved of pain by amputation, and this could not be predicted. Ten of 14 patients were cured of infection and 9 of 15 patients had improvement of residual function. In 28 of the amputations, RSD recurred in the stump, especially after amputation at a level which was not free from symptoms. Because of recurrence of RSD in the stump or severe hyperpathia only two patients wear a prosthesis. Despite this 24 patients were satisfied with the results.

Activities of Daily Living↗

Myoelectric signal processing for control of powered limb prostheses.

Progress in myoelectric control technology has over the years been incremental, due in part to the alternating focus of the R&D between control methodology and device hardware. The technology has over the past 50 years or so moved from single muscle control of a single prosthesis function to muscle group activity control of multifunction prostheses. Central to these changes have been developments in the means of extracting information from the myoelectric signal. This paper gives an overview of the myoelectric signal processing challenge, a brief look at the challenge from an historical perspective, the state-of-the-art in myoelectric signal processing for prosthesis control, and an indication of where this field is heading. The paper demonstrates that considerable progress has been made in providing clients with useful and reliable myoelectric communication channels, and that exciting work and developments are on the horizon.

Artificial Limbs↗

Custom design in lower limb prosthetics for athletic activity.

In summary, the prosthetist is the best source of information with regard to the fast-changing lower extremity prosthetics technology for sports. The needs and desires of the amputee should be outlined and balanced with the cost of the desired components and design. In many cases, one carefully designed prosthesis can serve in dual roles for everyday ambulation and certain athletic activities. In other cases, the amputee is limited severely by a prosthesis that is not designed for a specific activity. Using a prosthesis for activities that it was not designed to accommodate can cause physical injury to the amputee as well as structural failure of the device. A properly designed and fitted prosthesis can open a whole new world of activity to the amputee and helps him or her to reach the desired a vocational goals.

Activities of Daily Living↗

The mechanics of landing when stepping down in unilateral lower-limb amputees.

BACKGROUND: The ability to successfully negotiate stairs and steps is an important factor for functional independence. While work has been undertaken to understand the biomechanics of gait in lower-limb amputees, little is known about how amputees negotiate stairs and steps. This study aimed to determine the mechanics of landing in unilateral lower-limb amputees when stepping down to a new level. A secondary aim was to assess the effects of using a shank-mounted shock-absorbing device (Tele-Torsion Pylon) on the mechanics of landing. METHODS: Ten unilateral amputees (five transfemoral and five transtibial) and eight able-bodied controls performed single steps down to a new level (73 and 219 mm). Trials were repeated in amputees with the Tele-Torsion Pylon active and inactive. The mechanics of landing were evaluated by analysing peak limb longitudinal force, maximal limb shortening, lower extremity stiffness, and knee joint angular displacement during the initial contact period, and limb and ankle angle at the instant of ground-contact. Data were collected using a Vicon 3D motion analysis system and two force platforms. FINDINGS: Amputees landed on a straightened and near vertical limb. This limb position was maintained in transfemoral amputees, whereas in transtibial amputees knee flexion occurred. As a result lower extremity stiffness was significantly greater in transfemoral amputees compared to transtibial amputees and able-bodied controls (P<0.001). The Tele-Torsion Pylon had little effect on the mechanics of landing in transtibial amputees, but brought about a reduction in lower extremity stiffness in transfemoral amputees (P<0.05). INTERPRETATION: Amputees used a stepping strategy that ensured the direction of the ground reaction force vector was kept anterior of the knee joint centre. Using a Tele-Torsion Pylon may improve the mechanics of landing during downward stepping in transfemoral amputees.

Adult↗

Daily functioning of the lower extremity amputee: an overview of the literature.

The aim of this paper is to review the existing literature on the incidence, morbidity and mortality of lower limb amputation. The functional level of the lower limb amputee and the predictive factors for functioning with a prosthesis are reviewed, both for unilateral and for bilateral amputees. The reported incidence of lower extremity amputation (LEA) varies considerably between different Western countries. The mean survival of LEA patients ranges between two and five years. Assessment of functional outcome is carried out differently. Studies are not comparable and most concern selected groups of amputees. Increasing age, concurrent disease and poor compliance are prognostic factors for a low functional level. For optimal planning of rehabilitation it is necessary to study a complete cohort of amputees with respect to these prognostic factors.

Activities of Daily Living↗

[Functional evaluation of elderly patients with lower limb amputation followed at a university hospital].

We studied 40 elderly with lower limb amputation (above the malleolus), who attended a hospital outpatient clinic (Orthoses and Prostheses Unity, University Hospital, State University of Campinas), from June 1994 to June 1999. Our objectives were to evaluate the independence level according to the Barthel's Index and to identify relationships between the mentioned Index and the type and level of amputation, as well as the prosthetic use. The subjects had a high degree of independence, according to the Barthel's Index. We found statistical significance only for the relationship between the Barthel's Index and the type of amputation, suggesting that the elderly with unilateral amputation were more independent than those who had undergone bilateral amputation.

Activities of Daily Living↗

Centre of pressure displacements in trans-femoral amputees during gait.

The aim of this study was to describe and quantify centre of pressure (CoP) displacement during walking in 12 unilateral trans-femoral amputees who had worn a prosthesis for at least 10 years. All subjects wore the same type of prosthesis and seven healthy subjects acted as controls. The CoP was acquired by an F-scan system and the displacements along the longitudinal axis of the foot versus time were quantified. An asymmetry of both temporal and spatial parameters of CoP patterns occurred between the sound and the prosthetic foot. The double support time and the time during which the CoP remained in the heel and mid-foot region were longer for the prosthetic limb. Conversely, the stance phase was longer for the sound limb, as was the time spent by the CoP in the forefoot. There was a redistribution of the time during which the CoP remained within the different zones of the sound foot with respect to the normal feet of the control subjects. The asymmetry seen in trans-femoral amputee stance is due not only to an abnormal spatio-temporal distribution of the CoP under the prosthetic leg, but also to a modification of the spatio-temporal distribution of the CoP under the sound foot compared to the normal foot. We conclude that an adaptation occurs in the control of the stance phase on the sound side during amputee gait.

Adaptation, Physiological↗

Outcome of prosthetic management of bilateral lower-limb amputees.

This study was designed to evaluate the outcome in 41 bilateral lower-limb amputees admitted to an inpatient unit for prosthetic rehabilitation. Outcome measures were obtained using a simple activities of daily living score, the Frenchay Activities Index, mobility grading, and assessment of home adaptations. Though excellent success rates were obtained after completion of physiotherapy, the majority of the above-knee amputees had abandoned their prostheses by the time of review. Bilateral below-knee amputees, however, continued to do well regarding their prosthetic mobility, and prosthesis users were more independent in their activities of daily living. We believe that inpatient rehabilitation programmes for bilateral amputees are likely to prove more satisfactory than prolonged outpatient physiotherapy.

Activities of Daily Living↗

[Expert system of choosing lower limb (thigh) prosthesis and diagnosis of the quality of prosthetics (II)].

The authors review an expert system (ES) of diagnosing the prosthetics quality, elucidate problems of the ES functioning within the framework of the general ES. Special attention is paid to the description of the knowledge and datum surface, to the algorithms of direct and reverse illegible logical data output in taking decisions as to defects of the patient's prosthesis in accordance with the signs observable. The work of the ES is demonstrated with special reference to concrete cases. Analysis is made of the estimates of the sensitivity to the initial data. The ES presents knowledge in depth, being designed in two versions: for practical (individual and mass) prosthetics and training purposes.

Algorithms↗

Modification of the skin incision for the Van Nes limb rotationplasty.

The survival of patients with bone sarcomas has improved dramatically with the advent of modern chemotherapeutic regimens, fostering a present trend toward limb sparing procedures. In skeletally immature patients, prosthetic replacement of resected bones and joints is unrealistic because of continued expected growth in the limbs. A stump-lengthening procedure, the reduction-rotation-plasty, has become a valuable alternative to high above-knee amputation. A rhombus-shaped skin incision around the thigh and calf, originally described by Kotz and Salzer, led to a significant discrepancy of the circumference of the proximal and distal skin borders. A circumferential skin incision at the midthigh and a fishmouth-shaped incision at the upper calf was designed to decrease this disproportion. This incision has been used in five consecutive patients with osteosarcoma about the knee. The cosmetic results were excellent, prosthetic fittings were facilitated, and neither vascular nor wound healing problems were encountered.

Artificial Limbs↗

The application of shape memory actuators in anthropomorphic upper limb prostheses.

In recent years, single crystal Cu-Al-Ni alloys with shape memory behavior (SMB) became generally commercialized. They achieved the level of extended application, including upper limb human prosthesis with anthropomorphic characteristics. An actuator based in single crystal Cu-Al-Ni alloy was tested as a prototype for prosthetic actuators. Their thermal cycle times remarkably define the actuator dynamics and the idea of preheating to reduce its response time was tested. To elaborate the heating conditions, the chemical composition of martensitic and austenitic single crystals, Cu-Al-Ni alloy samples were examined. The dynamic response of a martensitic actuator made with SMB and the power consumed with preheating was analyzed. It demonstrates that the presence of more elements in alloys may be fundamental to displace the heating diagram and to reduce the power consumed.

Alloys↗