Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ARTHROPLASTY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84Linked to original sources

What's all that noise? The effect of co-morbidity on health outcome questionnaire results after knee arthroplasty.

BACKGROUND: We modified the Charnley Classification for hips to facilitate its use with knee arthroplasty patients and investigated what affect the different classes of co-morbidity had on the results of a spectrum of outcome questionnaires. PATIENTS AND METHODS: 3600 patients from the Swedish Knee Arthroplasty Registry were surveyed by post with a variety of questionnaires ranging from multiple-item general health, to a single-item knee arthroplasty specific questionnaire. All patients also completed a co-morbidity questionnaire, from which a modified Charnley Classification was generated for each patient. We then investigated the correlation and relationship between the results of the questionnaires and the different classes of co-morbidity. RESULTS: The results of the questionnaires tested varied significantly by Charnley Class, regardless of the specificity of the questionnaire used. INTERPRETATION: We suggest that co-morbidity should be taken into account in outcome studies utilizing general health or disease/site specific questionnaires.

Aged↗

Total hip arthroplasty in Denmark: incidence of primary operations and revisions during 1996-2002 and estimated future demands.

BACKGROUND: The annual number of total hip arthroplasties (THA) has increased in Denmark over the past 15 years. There is, however, limited detailed data available on the incidence of THAs. METHODS: We calculated the incidence rates (IR) of primary THA and revision in Denmark between 1996 and 2002 and estimated the demands for primary THA in Denmark until 2020. We used data from the Danish Hip Arthroplasty Registry, a nationwide and population-based clinical database, to identify patients who had undergone primary THA (n = 37,144) or revision arthroplasties (n = 6446). Age and sex-specific data on the Danish population were obtained from the StatBank Denmark. All IRs were standardized according to two standards, i.e. the Danish population in 1996 and the European standard population (18 age groups). The future demands for primary THA were estimated using the age and sex-specific incidence of primary THA for 2002 as a reference, and taking into account the expected changes in the age distribution of the population and the trend in IRs seen in Denmark between 1996 and 2002. RESULTS: The annual overall standardized IRs of primary THAs and revisions increased from 101 (95% confidence interval (CI): 97.6-104) to 134 (CI: 131-138) and from 19.2 (CI: 17.9-20.5) to 21.1 (CI: 19.8-22.4) per 100,000 inhabitants from 1996 to 2002, respectively (IRs adjusted to the Danish population in 1996). The IRs of primary THAs and revisions increased by 30% and 10% during this period. The relative increase in IRs of primary THAs was found to be similar in both women and men. The increase was higher among patients aged 50-59 years, however. Furthermore, a decrease in IRs was seen in patients who underwent primary THA due to rheumatoid arthritis. IRs of primary THAs have been estimated to increase by 22% in 2020 compared with 2002, based only on the expected changes in the age distribution of the population. However, assuming that the annual age and sex-independent increase in the IRs seen in the period 1996-2002 will continue, the IR of primary THA is estimated to increase by as much as 210% in 2020. INTERPRETATION: The overall annual standardized IRs of primary THAs and revisions in Denmark increased during the period from 1996 to 2002. Moreover, the demands for THA procedures in the coming decades may exceed the current capacity due to the ageing population and a continued age and sex-independent increase in surgical activity.

Adolescent↗

Early death following primary total hip arthroplasty: 1,727 procedures with mechanical thrombo-prophylaxis.

BACKGROUND: The aims of this study were to quantify the risk and identify the causes of early postoperative mortality after total hip arthroplasty. This would help clinicians address preventable causes of death and help in accurate counseling and consenting of patients. METHODS: We determined the death rate at 90 days in an unselected consecutive series of 1,727 primary total hip arthroplasties where patients had not routinely received chemothromboprophylaxis. RESULTS: The mortality at 90 days was 17/1,727 (1%). The 90-day mortality was 0.2% in patients under 70 years of age, 1.3% in patients between 70 and 80, and 2.5% in those over 80. 7 patients died from ischemic heart disease, 4 died following cerebrovascular events, and 2 from pulmonary embolism. 4 patients died from non-vascular causes. Of the vascular deaths, ischemic heart disease outnumbered cerebrovascular events which, in turn, outnumbered pulmonary embolism (7 vs. 4 vs. 2). INTERPRETATION: Strategies aimed at reducing deaths should address all vascular causes, not just pulmonary embolism. Our findings can be used to inform patients as to the risk of early death after total hip arthroplasty.

Age Factors↗

Bone grafting in total hip arthroplasty for insufficient acetabulum.

We assessed the effectiveness of total hip arthroplasty (THA) supplemented with autologous bone grafts in patients with congenital disease of the hip (CDH). 2 groups of patients were evaluated: In Group A, 33 patients with a mean age of 54 years underwent arthroplasties using a threaded ceramic conical acetabular cup without cement (Autophor). In Group B, 85 patients with a mean age of 55 years underwent arthroplasties using a threaded, noncemented, titanium cup (CST). Bone grafts were supplemented the THA in 3 ways: 1) intrapelvic application using the cotyloplasty technique, 2) as bone chips in order to cover small defects around the upper and lateral part of the cup, and 3) as a bulky corticocancellous graft which was secured with screws. Follow-up averaged 11 and 9 years for patients in Groups A and B, respectively. All the grafts in Group A had consolidated by the end of 6th month. Only 2 partial absorptions were observed, 1 intrapelvic graft and 1 corticocancellous graft. 2 revisions were performed in this group of patients, but neither were related to bone graft absorption. By the end of 6 month, 63 of 85 in Group B had consolidated bone grafts. In 16 patients with intrapelvic cotyloplasty, 3 demonstrated complete and 1 partial absorption of the grafts. 3 cup revisions were performed in this group of patients, all with complete graft absorption. Our findings indicate that autologous bone grafts are strong adjunct for satisfactory fixation of THA in patients with CDH, a particularly demanding group of patients to manage. In addition, the ceramic threaded cup was found to be superior to the titanium threaded cup in terms of both bone graft consolidation and the number of revisions required.

Acetabulum↗

Relationship of the functional recovery after hip arthroplasty to the neuroendocrine and inflammatory responses.

We studied the relationship between the neuroendocrine and inflammatory responses to hip arthroplasty and functional recovery in 102 patients undergoing elective arthroplasty for osteoarthritis. Blood samples were collected for up to 7 days after surgery and analysed for concentrations of norepinephrine, epinephrine, cortisol, interleukin-6 and C-reactive protein. The primary outcome measures were milestones in hospital, times to walk 10 and 25 m, pain on discharge from hospital, and function 1 and 6 months after surgery. Walking distances in hospital were significantly delayed in patients with greater interleukin 6 and C-reactive protein concentrations, but few neuroendocrine measures had significant correlations with functional recovery in hospital. Multivariate analysis showed that the interleukin 6 concentration on day 1 was the unique predictor of time to walk 10 and 25 m, and that the day 2 concentration of C-reactive protein was the unique predictor of pain on discharge from hospital. No significant correlations were found between the inflammatory and neuroendocrine variables and recovery at 1 and 6 months. We conclude that the inflammatory response affects immediate functional recovery after hip arthroplasty.

Adult↗

Shoulder arthroplasty in rheumatoid arthritis.

Replacement arthroplasty for the shoulder in rheumatoid arthritis is an operation which is being performed increasingly often. Several types of arthroplasty may be performed. One type is a true total shoulder replacement which involves replacing both the head of the humerus and the glenoid fossa. In a second type of arthroplasty, the articular surface of the humeral head is replaced. A modification of this type is the addition of a polyethylene spacer. Indictations for surgery, the surgical procedure, and the postoperative management are duscussed. The primary goal in the rheumatoid shoulder is a pain-free joint with a functional range of motion.

Arthritis, Rheumatoid↗

Extended "three-in-one" block after total knee arthroplasty: continuous versus patient-controlled techniques.

UNLABELLED: This prospective, randomized, double-blinded study assessed the efficacy of patient-controlled analgesia (PCA) techniques for extended "3-in-1" block after total knee arthroplasty. A total of 45 patients were divided into three groups of 15. Over 48 h, all patients received 0.125% bupivacaine with 1 microg/mL clonidine via a femoral nerve sheath catheter in the following manner: as a continuous infusion at 10 mL/h in Group 1; as a continuous infusion at 5 mL/h plus PCA boluses (2.5 mL/30 min) in Group 2; or as PCA boluses only (10 mL/60 min) in Group 3. Pain scores, sensory block, supplemental analgesia, bupivacaine consumption, side effects, and satisfaction scores were recorded. Pain scores and supplemental analgesia were comparable in the three groups. Bupivacaine consumption was significantly less in Groups 2 and 3 than in Group 1 (P < 0.01), and in Group 3 than in Group 2 (P < 0.01). Side effects and satisfaction were comparable in the three groups. We conclude that extended "3-in-1" block provides efficient pain relief after total knee arthroplasty and that, compared with a continuous infusion, PCA techniques reduce the local anesthetic consumption without compromise in patient satisfaction or visual analog scale scores. Of the two PCA techniques tested, PCA boluses (10-mL lockout; time, 60 min) of 0.125% bupivacaine with 1 microg/mL clonidine was associated with the smallest local anesthetic consumption, and is, therefore, the recommended extended "3-in-1" block technique. IMPLICATIONS: We demonstrated that, after total knee arthroplasty, an extended "3-in-1" block consisting of patient-controlled analgesia boluses (10 mL/60 min) of 0.125% bupivacaine with 1 microg/mL clonidine provides efficient postoperative analgesia and significantly minimizes local anesthetic consumption.

Aged↗

Aggressive warming reduces blood loss during hip arthroplasty.

UNLABELLED: We evaluated the effects of aggressive warming and maintenance of normothermia on surgical blood loss and allogeneic transfusion requirement. We randomly assigned 150 patients undergoing total hip arthroplasty with spinal anesthesia to aggressive warming (to maintain a tympanic membrane temperature of 36.5 degrees C) or conventional warming (36 degrees C). Autologous and allogeneic blood were given to maintain a priori designated hematocrits. Blood loss was determined by a blinded investigator based on sponge weight and scavenged cells; postoperative loss was determined from drain output. Results were analyzed on an intention-to-treat basis. Average intraoperative core temperatures were warmer in the patients assigned to aggressive warming (36.5 degrees +/- 0.3 degrees vs 36.1 degrees +/- 0.3 degrees C, P< 0.001). Mean arterial pressure was similar in each group preoperatively, but was greater intraoperatively in the conventionally warmed patients: 86+/-12 vs 80+/-9 mm Hg, P<0.001. Intraoperative blood loss was significantly greater in the conventional warming (618 mL; interquartile range, 480-864 mL) than the aggressive warming group (488 mL; interquartile range, 368-721 mL; P: = 0.002), whereas postoperative blood loss did not differ in the two groups. Total blood loss during surgery and over the first two postoperative days was also significantly greater in the conventional warming group (1678 mL; interquartile range, 1366-1965 mL) than in the aggressively warmed group (1,531 mL; interquartile range, 1055-1746 mL, P = 0.031). A total of 40 conventionally warmed patients required 86 units of allogeneic red blood cells, whereas 29 aggressively warmed patients required 62 units (P = 0.051 and 0.061, respectively). We conclude that aggressive intraoperative warming reduces blood loss during hip arthroplasty. IMPLICATIONS: Aggressive warming better maintained core temperature (36.5 degrees vs 36.1 degrees C) and slightly decreased intraoperative blood pressure. Aggressive warming also decreased blood loss by approximately 200 mL. Aggressive warming may thus, be beneficial in patients undergoing hip arthroplasty.

Adult↗

Regional hemostatic status and blood requirements after total knee arthroplasty with and without tranexamic acid or aprotinin.

UNLABELLED: Antifibrinolytics seem to reduce postoperative blood loss after total knee arthroplasty. Few studies have shown the impact of these drugs on the mechanisms of coagulation. The purpose of this study was to examine coagulation/fibrinolysis variables as well as blood loss after total knee arthroplasty with and without antifibrinolytics in the operated limb on a regional level. Thirty-six patients were randomized into one of three groups to receive aprotinin, tranexamic acid, or no medication. We took blood samples of the femoral vein before deflating the tourniquet and after 5, 10, 30, 60, 120 min and on the first postoperative day. The implantation of a knee prosthesis in artificial ischemia caused a significant activation of coagulation and fibrinolysis in the regional circulation. Tranexamic acid and aprotinin did not cause a significant modulation of fibrinolysis variables or a significant reduction of postoperative bleeding and transfusion requirements. One of the differences in comparison to other studies was the decreased total blood loss. The use of bone cement as well as surgical hemostasis before wound closure may be regarded as reasons for this. Therefore, primarily these methods should be used because there is no increased risk of adverse drug effects. IMPLICATIONS: After total knee arthroplasty total blood loss may be kept in a low range if methods such as cemented knee prosthesis and surgical hemostasis are used. In this case aprotinin and tranexamic acid did not cause a significant modulation of fibrinolysis variables or a significant reduction of postoperative bleeding.

Adult↗

Continuous psoas compartment block for postoperative analgesia after total hip arthroplasty: new landmarks, technical guidelines, and clinical evaluation.

UNLABELLED: A computed tomographic scan was obtained in 35 patients to measure the depth and the relationship of the branches of the lumbar plexus to the posterior superior iliac spine projection and the vertebral column. In addition, we prospectively studied 80 patients scheduled for total hip arthroplasty who received a continuous psoas compartment block (CPCB) in the postoperative period. CPCB was performed after surgical procedures by using modified Winnie's landmarks and nerve stimulation. From 5 to 8 cm of catheter was inserted. Radiographs were obtained after injection of 10 mL of contrast medium. An initial loading dose (0.4 mL/kg) of 0.2% ropivacaine was injected, followed by continuous infusion of 0.2% ropivacaine for 48 h. The depth of the lumbar plexus and the distance between the lumbar plexus and the L4 transverse process were measured. Visual analog scale values of pain at 1, 12, 24, and 48 h were obtained at rest and during mobilization. Amounts of rescue analgesia were also recorded. Sensory blockade of the principal branches of the lumbosacral plexus was noted at 1 and 24 h, as were adverse events related to the technique. There was a significant difference between men and women in depth of the lumbar plexus (median values, 85 vs 70 mm for men and women, respectively). There was a positive correlation between the body mass index and skin-lumbar plexus distances. In contrast, there was no difference regarding the distance between the transverse process of L4 and the lumbar plexus. The catheter tip lay within the psoas major muscle in 74% of the patients and between the psoas and quadratus lumborum muscles in 22%. In three patients, the catheter was improperly positioned. At 1 h, sensory blockade of the femoral, obturator, and lateral femoral cutaneous nerves was successful in, respectively, 95%, 90%, and 85% of patients. At 24 h, these rates were 88%, 88%, and 83%, respectively. During the 48-h study period, median visual analog scale values of pain were approximately 10 mm at rest and from 18 to 25 mm during physiotherapy. Five patients received 5 mg of morphine at 1 h. Five cases of unilateral epidural anesthesia were noted after the bolus injection. We conclude that CPCB with 0.2% ropivacaine allows optimal analgesia after hip arthroplasty, with few side effects and a small failure rate. Before lumbar plexus branch stimulation and catheter insertion, anesthesiologists should be aware of the L4 transverse process location and lumbar plexus depth. IMPLICATIONS: Lumbar plexus depth is correlated with the patient's body mass index and differs between men and women, but this is not true of the lumbar plexus-transverse process distance. Considering new landmarks, a continuous psoas compartment block promotes optimal analgesia after hip arthroplasty, with few side effects.

Adult↗

Ambulatory continuous interscalene nerve blocks decrease the time to discharge readiness after total shoulder arthroplasty: a randomized, triple-masked, placebo-controlled study.

BACKGROUND: A continuous interscalene nerve block (CISB) may be used to provide analgesia after shoulder arthroplasty. Therefore, inpatient stays may be shortened if CISB (1) provides adequate analgesia without intravenous opioids and (2) improves shoulder mobilization. This study investigated the relationship between ambulatory CISB and the time to reach three discharge criteria after shoulder arthroplasty. METHODS: Preoperatively, patients received a CISB. All patients received a perineural 0.2% ropivacaine infusion from surgery until 06:00 the following morning, at which time they were randomly assigned either to continue perineural ropivacaine or to switch to normal saline. The primary endpoint was the time from the end of surgery until three discharge criteria were attained (adequate analgesia, independence from intravenous analgesics, and tolerance to 50% of shoulder motion targets). Patients were discharged home as early as the afternoon after surgery with their CISB using a portable infusion pump. RESULTS: Patients receiving perineural ropivacaine (n = 16) attained all three discharge criteria in a median (10th-90th percentiles) of 21 (16-41) h, compared with 51 (37-90) h for those receiving perineural normal saline (n = 13, P < 0.001). Unlike patients receiving perineural ropivacaine, patients receiving perineural normal saline often required intravenous morphine, but still experienced a higher degree of pain and tolerated less external rotation. CONCLUSIONS: An ambulatory CISB considerably decreases the time until readiness for discharge after shoulder arthroplasty, primarily by providing potent analgesia that permits greater passive shoulder movement and the avoidance of intravenous opioids. Additional research is required to define the appropriate subset of patients and assess the incidence of complications associated with earlier discharge.

Aged↗

Perioperative exercise programs improve early return of ambulatory function after total hip arthroplasty: a randomized, controlled trial.

OBJECTIVE: Patients with endstage hip arthritis have poor ambulatory function. The aim of this study was to determine if perioperative exercise programs are well tolerated by these elderly patients and if a customized program can achieve an earlier recovery of normal ambulatory function after total hip arthroplasty. DESIGN: Twenty-eight subjects scheduled for total hip arthroplasty were randomized to either the exercise group and received a perioperative customized exercise program or the control group and received the routine perioperative care. Ambulatory function was assessed by measurement of gait parameters during a 25-m walk test, and walking endurance was assessed by a 6-min walk test. RESULTS: Exercise group subjects attended 97.3% of scheduled exercise sessions with no training injuries. Exercise group subjects demonstrated greater stride length and gait velocity at 3 wk postsurgery. At 12 and 24 wk postsurgery, gait velocity was greater, and the 6-min walking distance was significantly greater than the control group. CONCLUSION: The study indicates that perioperative customized exercise program are well tolerated in the elderly patient with endstage hip arthritis and are effective in improving the rate of recovery in ambulatory function in the first 6 mo after total hip arthroplasty.

Aged↗

In vivo anteroposterior femorotibial translation of total knee arthroplasty: a multicenter analysis.

A study was conducted to determine in vivo femorotibial contact patterns for subjects having a posterior cruciate retaining or posterior cruciate substituting total knee arthroplasty. Femorotibial contact of 72 subjects implanted with a total knee replacement, performed by five surgeons, was analyzed using video fluoroscopy. Thirty-one subjects were implanted with a posterior cruciate retaining total knee replacement with a flat polyethylene posterior lipped insert, 12 with a posterior cruciate retaining total knee replacement with a curved insert, and 29 with a posterior cruciate substituting total knee replacement. Each subject performed successive deep knee bends to maximum flexion. Video images at 0 degree, 30 degrees, 60 degrees, and 90 degrees flexion were downloaded onto a workstation computer. Femorotibial contact paths were determined for the medial and lateral condyles using an interactive model fitting technique. Femorotibial contact anterior to the tibial midline in the sagittal plane was denoted as positive and contact posterior was denoted as negative. Analysis of average femorotibial contact pathways of both posterior cruciate retaining designs revealed posterior femorotibial contact in full extension with anterior translation of femorotibial contact commonly observed in midflexion and terminal flexion. In posterior cruciate substituting designs, anterior femoral translation was seen medially at 30 degrees to 60 degrees flexion but rarely was observed laterally. Posterior femoral rollback laterally from full extension to 90 degrees flexion was seen in 100% of subjects implanted with a posterior cruciate substituting total knee replacement, versus 51.6% (posterior lipped polyethylene insert) and 58.3% (curved insert) of those with a posterior cruciate retaining total knee replacement. Data from this multicenter study are remarkably similar to previous fluoroscopy data from a single surgeon series, showing a lack of customary posterior femoral rollback in both posterior cruciate retaining designs, and conversely showing an average anterior femoral translation with knee flexion. Posterior femoral rollback, less than in normal knees, routinely was observed in posterior cruciate substituting total knee arthroplasty, attributed to engagement of the femoral component cam with the tibial post. The abnormal anterior femoral translation observed in posterior cruciate retaining total knee arthroplasty may be a factor in premature polyethylene wear observed in retrieval studies.

Arthroplasty, Replacement, Knee↗

Cement versus cementless fixation in total knee arthroplasty.

A prospectively studied group of 55 uncemented Press Fit Condylar total knee arthroplasties was compared retrospectively with a matched group of 51 cemented Press Fit Condylar total knee arthroplasties at a mean of 10 years after operation. For the cemented group, the pain and function scores improved from 32 and 45 preoperatively to 95 and 77, respectively. For the uncemented group the scores improved from 33 and 50 preoperatively to 93 and 60, respectively. There were 10 revisions in the uncemented group for femoral or tibial aseptic loosening or osteolysis compared with two revisions in the cemented group. Exclusive of problems related to patellar metal backing, survival to revision for aseptic failure or radiographic loosening was 72% in the uncemented group and 94% in the cemented group at 10 years. A significantly higher revision rate was found in the uncemented compared with cemented total knee arthroplasty of the Press Fit Condylar design.

Arthralgia↗

Intramedullary pressure and pulmonary function during total knee arthroplasty.

Twenty-eight patients who underwent unilateral total knee arthroplasty and 20 patients who underwent simultaneous bilateral total knee arthroplasties participated in this study and were randomized to have either a fluted or round 10-mm diameter femoral intramedullary alignment rod used during surgery. The intramedullary rods were cannulated and connected with pressure tubing to a monitor which provided measurements of pressure at the tip of each rod. Arterial blood gas measurements on room air were obtained before and on the morning after surgery. An arterial line was placed and an arterial blood gas measurement was obtained at the time of skin incision and again after tourniquet release. Pulmonary shunt was calculated from the arterial blood gas measurements. Intramedullary pressure during rod insertion was significantly higher for the groups of patients having the round compared with the fluted rod. The change in pulmonary shunt during surgery was lowest for the patients in the unilateral group having the fluted rod and highest for the patients in the bilateral group having the round rod. A fluted rather than a round intramedullary alignment rod should be used to minimize intramedullary pressure and pulmonary shunting during unilateral and bilateral total knee arthroplasties.

Analysis of Variance↗

Knee arthroplasty in hemophilic arthropathy.

Twenty-three total knee arthroplasties in 15 patients with severe hemophilia were performed between February 1974 and September 1988. Thirteen patients had Factor VIII deficiency and two had Factor IX deficiency. The mean followup period was 7.5 years, with a minimum of 4 years for patients who were alive (eight) at the time of this review. Seven patients had died before this report, and all were seropositive for the human immunodeficiency virus. Using the Hospital for Special Surgery knee scoring system, the result was excellent in one knee, good in three, fair in two, and poor in 17. One patient was seropositive for the human immunodeficiency virus at the time of the index procedure, and 12 were seropositive at the most recent followup; the human immunodeficiency status of three patients was unknown. There were two early and two late deep infections, all in patients who were seropositive for the human immunodeficiency virus. The most recent postoperative radiographs for all knees were reviewed using the Knee Society radiographic scoring system. Ten femoral components were well fixed, 11 were possibly loose, and two were probably loose. Eight tibial components were well fixed, 10 possibly loose, three probably loose, and two definitely loose. One knee had been revised for aseptic loosening. There are few published studies of the long term results of total knee arthroplasties in patients with hemophilia. In this series of 23 knees, there was a high rate of loosening and infection. Total knee arthroplasty may be a useful treatment for the relief of pain attributable to end stage hemophilic arthropathy, but there is a high rate of complications, especially in patients who are seropositive for the human immunodeficiency virus.

Adolescent↗

Omnifit cementless total hip arthroplasty. A 10-year average followup.

Seventy-six hips in 67 patients were evaluated an average of 119 months (range, 61-150 months) after total hip arthroplasty with porous coated Omnifit femoral and acetabular components. The patients were young (average age, 45 years), and most were male (67%). Two stems and one cup were revised for aseptic loosening, for aseptic revision rates of 2.6% on the femoral side and 1.3% on the acetabular side. Thigh pain was present in three cases, one of which was activity limiting. Twenty-five (35.7%) hips had evidence of osteolysis confined to proximal Gruen Zone 1 or 7 or to the acetabulum (22 proximal femoral, three both). There were no cases of intramedullary osteolysis in surviving stems. Thirteen (17.1%) hips have undergone reoperation for bone grafting of progressive proximal osteolysis without component revision, at an average 93 months after the total hip arthroplasty. At an average 40 months after reoperation, all stems remain well fixed, and there has been no recurrence of osteolysis of grafted femoral lesions. These results suggest that a circumferentially proximally porous coated femoral component in cementless total hip arthroplasty can provide stable fixation for as long as 12 years after implantation and caseal the canal from distal osteolysis. Serious concerns remain about the incidence of proximal femoral osteolysis.

Adult↗

Use of a polyglycolide lactide cement plug restrictor in total hip arthroplasty.

The use of a polyglycolide lactide cement plug restrictor in cemented femoral fixation during total hip arthroplasty was evaluated. Femoral cement pressurization was evaluated in vitro in a cadaveric model and the host response to polymer degradation was evaluated in vivo in a canine total hip arthroplasty model. Sixteen embalmed anatomic specimen femurs were prepared for cement femoral fixation. The intramedullary canal was plugged with either an ultrahigh molecular weight polyethylene cement plug restrictor or a polyglycolide lactide cement plug restrictor. Peak pressures in the proximal, mid, and distal portions of the cement mantle were recorded during cement insertion, cement pressurization, and implant insertion. There was no difference between the two plug groups in peak pressures throughout the cement mantle during cement insertion, pressurization, or implant insertion. Total hip arthroplasty using a cementless acetabular component and a cemented femoral stem was performed in 24 dogs. The femoral intramedullary canal was plugged with a polyethylene or a biodegradable cement plug restrictor. The dogs were sacrificed at 7 weeks, 10 months, or 15 months. Radiographically, no osteolytic lesions were seen around either plug type. Histomorphometrically, the polyglycolide lactide plugs appeared intact at 7 weeks and partially degraded by 10 and 15 months. In both plug groups, a mild fibrohistiocytic reaction with infiltration of fibrocytes, histocytes, and endothelial cells was seen. No osteolysis was observed. The results of the current study show that femoral cement pressurization can be attained in vitro using a biodegradable cement plug restrictor and that for as long as 15 months in the in vivo canine model there were no adverse reactions associated with use of these plugs compared with conventional ultrahigh molecular weight polyethylene plugs.

Animals↗