Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84Linked to original sources

Influence of the remaining coronal structure on the resistance of teeth with intraradicular retainer.

The aim of this study was to compare the resistance of endodontically treated teeth with intraradicular retainer different amounts of remaining coronal structure. Fifty freshly extracted maxillary canines were endodontically treated and randomly assigned to five groups (n=10), as follows: group 1 (control) = teeth with custom cast post and core; group 2 = teeth without remaining coronal structure; group 3, 4 and 5 = teeth with 1 mm, 2 mm and 3 mm of remaining coronal structure, respectively. All specimens in groups 2 to 5 were restored with prefabricated post and resin core. The teeth were embedded in acrylic resin and the fracture strength was measured on a universal testing machine at 45 degrees to the long axis of the tooth until failure. Data were analyzed statistically by one-way analysis of variance and Tukey's test. There was no significant differences (p>0.05) between the control group and group 2, and between groups 3, 4 and 5 (p>0.05). Control group and group 2 had significantly higher resistance strength than groups 3, 4 and 5 (p<0.00001). The findings of this study showed that teeth without remaining coronal structure had significantly higher fracture strength than those with remaining coronal structure (1 mm, 2 mm and 3 mm). When the dental crown was not completely removed, the amount of remaining coronal dentin did not significantly affect the fracture strength of endodontically treated teeth with intraradicular retainer.

Acetone↗

Porosity in resin composite core restorations: the effect of manipulative techniques.

Forty acrylic resin duplicates of an endodontically treated and extracted human molar were restored with two resin composite materials for core restorations. Two different manipulation techniques, bulk insertion and syringe application, were used. In a simulated clinical setup, the core buildups produced by the different manipulation techniques were investigated for voids. In 20 duplicates, a post was placed to simulate a metal post and resin composite core buildup. The syringe technique produced significantly fewer incorporated voids for both resin composite core materials than did the bulk insertion technique. It was not possible to demonstrate a relationship between the presence of voids and the presence of a metal post.

Analysis of Variance↗

A flexible moulage for the fabrication of an orbital prosthesis.

A technique is disucssed by which a flexible three-piece moulage may be fabricated. This procedure is a useful aid in the modeling of an orbital prosthesis. It permits the continued transfer of a wax pattern from the moulage to the patient utilizing the tissue undercuts for the retention and stabilization of the pattern. The critical task of properly positioning the ocular prosthesis is simplified by the increased stability of the entire pattern. This is of the utmost importance since even a slight error in the alignment of the eye can entirely negate the effect of an otherwise accurate prosthesis. In addition, the retention of the wax pattern simplifies the carving procedure, and accurate detail is easily secured. The acrylic resin surface on which the final silicone prosthesis is cured has proven to be accurate. Well-adapted, thin margins of the facial prosthesis have been consistently obtained.

Acrylic Resins↗

Acceptability of maxillary major connectors in removable partial dentures.

BACKGROUND: The choice of connector lies between plate, a bar or a combination of bars, which may cross the palate in various positions. Many opinions have been expressed concerning the acceptability to the patients of the various forms of palatal connectors but there have been few investigations. OBJECTIVES: The aim of this study is to compare subjective patients' reactions to three maxillary major connectors: metal bar, metal plate, and acrylic connectors and to establish the most acceptable and the least acceptable maxillary major connectors. METHODS: Fifteen consecutive patients attending the prosthetic out-patient clinic of Dental Center, University College Hospital, Ibadan who had never worn dentures were recruited into the study. Three dentures each with a different maxillary major connector design were fabricated for each patient. A questionnaire was administered to ascertain their reactions to each of the three denture designs. RESULTS: Fourteen patients (93.3%) preferred the denture with metal palatal bar major connector whereas only one patient preferred the denture with acrylic plate major connector design. No patient preferred the palatal metal plate connector design. CONCLUSIONS: The metal bar major connector was the most acceptable maxillary major connector while acrylic resin plate was more acceptable than metal plate maxillary major connector. It also confirmed the influence of connector design on patient acceptance of removable partial denture.

Acrylic Resins↗

Microleakage and marginal gap formation of glass ionomer resin restorations.

The purpose of this in vitro study was to compare microleakage and marginal gap formation of three light-cured glass ionomer cements (LCGI). Thirty non-carious human premolar teeth were used in this study. A Class V cavity was prepared in the buccal surface of each tooth. The teeth were randomly divided into three experimental groups of 10 teeth each and restored with three LCGI materials. The teeth in each group were processed for microleakage study using 5% methylene blue. Subsequently, each tooth was embedded in acrylic resin and sectioned longitudinally in a buccolingual direction. Examination of the specimens for dye penetration was done. Later, evaluation of marginal gap formation and analysis of adhesion mechanism were done using SEM. The results indicated that LCGI restorations placed in vitro without thermocycling did not consistently prevent microleakage. Vari Glass VLC showed the least leakage. There was no significant difference in the microleakage between the occlusal and gingival margins. Marginal gap formation was found only in one LCGI material. Generally, the presence of a clearly identified ion-exchange layer was not found.

Acrylic Resins↗

The use of silicon elastomer in maxillofacial rehabilitation as a substitute for or in conjunction with resins.

Maxillofacial prosthetic rehabilitation aims to restore anatomic function when serious tissue defects are present, as a result of congenital factors, trauma, or surgery. The aims are both aesthetic and functional, and results are obtained using devices that contain, reconstruct, and fill. This study introduces a technique using methods and materials that are acceptable to the patient in that they satisfy chewing, phonetic, and aesthetic functions, while respecting bone structure and restoring function to the soft tissues without causing trauma to them. Our techniques do not use innovative materials, but ones that are structurally different and that, until now, have not been connected with attachment systems. Acrylic resin, acetylic resin, and silicon are used, each in such a way as to take maximum advantage of each material's characteristics and thus give the best results.

Acrylic Resins↗

Modified custom tray.

The use of a custom tray is highly desirable for accurate impression making in situations with multiple abutments. This article describes a modified custom tray fabrication method using autopolymerizing acrylic resin. The custom tray is fabricated by intraoral relining with autopolymerizing resin that is polymerized extraorally. The final impression is obtained during the same session after tray polymerization at 100 degrees C for 5 minutes. Relined areas are refined by trimming excess resin with burs of a known diameter to create a 2-mm clearance for the elastomer. For areas with subgingival finish lines, only 0.5 mm of resin is removed to direct the elastomer into the gingival sulcus. The procedure is time-saving because it reduces the need for a retraction cord and minimizes inaccuracies that would necessitate another impression.

Acrylic Resins↗

LR White embedding allows a multi-method approach to the analysis of brain tissue from patients with Alzheimer's disease.

Light (LM) and electron (EM) microscope comparisons of the cytochemistry and immunocytochemistry of neuritic plaques and neurofibrillary tangles, the main histopathological changes in the brains of Alzheimer's disease sufferers, have been almost impossible because of the disparity between the two technologies. By embedding unosmicated brain tissue in the acrylic resin LR White, direct comparisons can be made between techniques applied at the LM level with those at the EM level. After partial dehydration in 70% ethanol, the tissue is embedded by rapid infiltration and polymerization at 0 degrees C, which has been shown to maximally preserve tissue immunoreactivity. Semithin sections are then receptive to routine LM stains, silver stains e.g. Gomori's methenamine silver, and immunocytochemistry with immunoperoxidase or immunocolloidal gold. Serial thin sections are stable in the EM and can be immunolabelled and directly compared with their LM counterparts. Results from the use of a mouse monoclonal antibody against beta-amyloid and a rabbit polyclonal antibody against ubiquitin are presented. LR White resin includes no elements other than carbon, oxygen and nitrogen, of which it is composed, so that sections of it are valuable for sensitive X-ray energy dispersive microanalysis.

Acrylic Resins↗

Accuracy of adaptation of thermoformed poly(methyl methacrylate).

Thermoformed poly(methyl methacrylate) (PMMA) sheet is used to produce a number of different dental appliances such as stents, occlusal splints and baseplates for occlusal rims. The purpose of the present study was to measure the accuracy of adaptation of Perspex PMMA sheet and to determine the effect of annealing on the accuracy of the thermoformed specimens. The results of the study showed that PMMA can produce specimens that are accurately adapted to the cast. Immersion in water resulted in an increase in the space between the cast and the specimen for both thermoformed and thermoformed and annealed acrylic resin. Annealing of the thermoformed specimens had significantly less increase in space between the cast and the specimens when immersed in water over a period of 3 months.

Acrylic Resins↗

Esthetic options for the fabrication of removable partial dentures: a clinical report.

This clinical report describes a procedure for influencing the esthetics of a Kennedy Class III-Modification 1 removable partial denture. The acrylic resin base is eliminated, and the retentive clasp placed on the first premolars is modified. This technique is simple and inexpensive, and in the treatment presented, it resulted in complete patient satisfaction.

Acrylic Resins↗

The effect of three different recording materials on the reproducibility of condylar guidance registrations in three semi-adjustable articulators.

Sagittal condylar guide settings of three semi-adjustable articulators: WhipMix, Hanau 158 and Denar Mark II were compared using registrations of base plate wax, copper wax and self-curing acrylic resin in two subjects. Four-way ANOVA showed differences between instruments (P < 0.0001), materials (P < 00001), registrations (P < 0.0001), and no difference between operators. Mean differences between materials were 3 degrees and 6 degrees within the range of registration and articulator variability. Denar Mark II gave the highest values, Hanau 158 the lowest with pantronic values generally lower than articulator settings. Neither acrylic nor copper wax were superior to base plate wax. This and previous studies show low reproducibility and variability between instruments, occlusal records and registration material.

Acrylic Resins↗

Silane coupling agents in stainless steel and polymethyl methacrylate systems.

Smooth stainless steel rods coated with silanes were embedded in acrylic resin dough. The strength of the bond between treated rods and polymerized resin was improved compared with that found in the untreated rods under all conditions of the tests. The strength increased with age when specimens were left in air; immersion in water lessened the increase in strength.

Acrylic Resins↗

Review of methods for removing cast gold restorations.

Most techniques and devices described for crown removal, in one way or another, destroy the integrity of today's precision cast crowns. There were only three techniques described that do not require drilling a hole, cutting a notch or slot, clamping with claws or jaws, prying with instruments, or grasping with forceps and pliers. These are the copper band filled with cement, the coping of cold-curing acrylic resin, and the Richwil crown remover. The safest and least traumatic of all crown removal devices and techniques is to cut a slot and pry the crown loose. Although the crown is destroyed, damage to the tooth is avoided.

Acrylic Resins↗

Techniques for making spacers in interstitial brachytherapy for tongue cancer.

The use of a spacer has been recommended in interstitial brachytherapy for tongue cancer to reduce the radiation dose to the mandible. This article describes the development of two types of acrylic resin spacers, a mouth guard-type spacer for dentate patients, and a replica denture-type spacer for edentulous patients. These spacers can be used without suture retention and are comfortable for patients.

Acrylic Resins↗

Observation of horizontal mandibular positions in an edentulous patient using a digital gothic arch tracer: a clinical report.

Dentures were fabricated for a 73-year-old woman using porcelain 20-degree maxillary posterior teeth and acrylic resin flat planes in the mandibular posterior region. A digital gothic arch tracing device was used to observe the horizontal mandibular positions before insertion and to evaluate the therapeutic effect of the diagnostic dentures at 1 and 3 months after insertion.

Acrylic Resins↗

Temporary prosthetic base materials: reproduction of surface detail.

The baseplate material that best reproduced the most grooves in a gypsum cast was filled cold cure acrylic resin, followed in turn by modelling wax, grey shellac and finally the pink shellac material. These latter three thermoplastic materials performed best when softened in a water bath and subsequently adapted to a prewarmed cast.

Acrylic Resins↗

Marginal accuracy of interim restorations fabricated from four interim autopolymerizing resins.

STATEMENT OF PROBLEM: One of the most important requirements for interim restorations is good marginal adaptation. Polymerization shrinkage of interim restorative materials can jeopardize the marginal integrity of interim restorations. PURPOSE: The purpose of this study was to compare the marginal accuracy of interim restorations made with 4 interim materials. MATERIAL AND METHODS: A direct technique was used to fabricate 44 interim restorations with 4 materials: Protemp 3 Garant, Trim II, Tempron, and Acropars (n=11). The interim restorations were made on a prepared molar-shaped metal die with a vinyl polysiloxane impression as a matrix. Marginal discrepancy of interim restorations was measured at the midpoint of buccal, palatal, mesial, and distal surfaces of metal die finish line with a microscope at x100 magnification. Comparisons were made with 1-way analysis of variance and the Duncan multiple range test (alpha=.05). RESULTS: The mean marginal discrepancies of Protemp 3 Garant, Trim II, Tempron, and Acropars were 0.059, 0.063, 0.068, and 0.102 mm, respectively. Acropars exhibited the most marginal discrepancies and was significantly different from the other materials tested (P<.001). However, there were no statistical differences between the other 3 materials tested. CONCLUSIONS: Interim restorations made from the Bis-GMA and conventional acrylic resins tested produced comparable marginal fit. Acropars demonstrated significant increases in marginal gap size.

Acrylic Resins↗