Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Volatilization”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83Linked to original sources

Application of headspace solid-phase microextraction to the determination of sulphur compounds with low volatility in wines.

Headspace solid-phase microextraction (HS-SPME) has been used for determining sulphur compounds with low volatility in wines. With this technique, handling of samples is minimal so undesirable loses and reactions between compounds are prevented. Furthermore, this kind of extraction is fast and does not require any organic solvent. Under optimal conditions, the HS-SPME, using a new fibre coated with Stable Flex divinylbenzene-Carboxen-polydimethylsiloxane, makes possible the quantification of sixteen sulphur compounds with low volatility which may be present in wines. The limits of detection for the analytes studied ranged between 0.05 and 10 microg/l, and the recovery and repeatability found were acceptable. The method developed was successfully applied to determine the concentration of the target analytes in varietal wines from the Catalonian region (Spain) with some aromatic defects such as an odour of rubber, onion, rotten, unpleasant herbaceous, etc. The results show that the contents of the sulphur compounds studied in these wines are higher than in those without defects. This shows a relationship exists between the presence of sulphur compounds and the quality of the wine aroma.

Chromatography, Gas↗

Profiles of volatile metabolities in body fluids.

A method for the analysis of volatile metabolites present in plasma, urine, breast milk and amniotic fluid collected from mother-infant pairs has been developed which requires only 100 mul of plasma, 3 ml of urine, 20 mul of breast milk and 500 mul of amniotic fluid. After extraction with diethyl ether, the volatile compounds were absorbed on glass wool in a special concentration tube and subsequently desorbed and transferred to a 100-m nickel capillary column for analysis by gas chromatography and gas chromatography-mass spectrometry. The separations, carried out by temperature programming, were complete in 90 min.

Alcohols↗

Multicomponent analysis of volatile organic compounds in water by automated purge and trap coupled to gas chromatography-mass spectrometry.

The performance of an automated purge and trap concentrator coupled to gas chromatography-mass spectrometric detection was evaluated by analyzing 40 volatile organic compounds of different chemical families. Compounds chosen defined as toxic for the environment and for human health were selected according to Directive 76/464/CEE. The present work includes: (i) the optimization of the purge and trap conditions, (ii) the establishment of quality parameters and in last instance (iii) the analysis of surface waters. The analytical method consisted of a modification of the EPA Method 524.2 in which water was pumped, via an automated AquaTek 70 Liquid Autosampler to a 25-ml purging device, where samples were purged and trapped in a Tenax or Tenax-Silica and Charcoal column. Afterwards, helium was used to desorb the trapped analytes that flow directly into the GC column. Mass spectrometric analysis was carried out in selected ion monitoring and scan modes to ensure quantification and confirmation of the results. Parameters optimized were the sample volume analyzed, bubbling flow-rate and time and temperature of desorption. Optimal conditions lead to mean recoveries of 80%, limits of detection between 0.002 and 0.1 microg/l, linearity from 0.01 to 2.5 microg/l and maximum standard deviation of 10%, using a Tenax trap. This protocol permitted a high precision and sample throughput and was used to determine volatile organic compounds in surface river, effluents and coastal waters of Portugal, on a routine basis.

Calibration↗

Volatile components from Anthriscus sylvestris (L.) Hoffm.

The volatile components of fresh leaves and roots from Anthriscus sylvestris (L.) Hoffm., obtained through hydrodistillation, were analysed by GC and GC-MS. This was compared to dichloromethane extracts of both fresh and dried leaf and root material. The monoterpene fraction (69-70%) dominated, while beta-phellandrene (39-45%) was the main component in both the leaf and the root oil. Other components in the leaf oil were beta-myrcene (17%), sabinene (6.2%), Z-beta-ocimene (5.4%) and benzene acetaldehyde (4.1%). In the roots we found Z-beta-ocimene (16.9%) and alpha-pinene (4.6%) as other major components. These principle constituents of both essential oils were also present in the dichloromethane extracts of the fresh and dried leaves and the roots, although in much smaller percentages. Comparing hydrodistillation of fresh plant material with a dichloromethane extract, the latter yielded a considerably lower amount of constituents. In addition, air drying and freeze drying resulted in a significant loss of volatile constituents as compared to fresh material (dichloromethane extract).

Apiaceae↗

Role of the retaining precolumn in large-volume on-column injections of volatiles to gas chromatography.

In the present study the retaining precolumn, which is commonly used in a set-up for large-volume on-column injections, or when solid-phase extraction (SPE) or liquid chromatography is coupled to gas chromatography (CC), was removed after varying its length from the standard length of 3 m down to zero. A dramatic increase of the evaporation rate of the injected organic solvent was obtained from a typical value of 100 microl/min up to 300 microl/min. The increased evaporation rate allowed (i) injection of a larger volume in the same retention gap, (ii) faster injection/transfer of the organic solvent and (iii) reduction of the transfer temperature. As volatile compounds under partially concurrent solvent evaporation conditions are easily lost once the organic solvent has been removed via a solvent-vapour exit (SVE), the parameters for large-volume injection, i.e. the evaporation rate and injection speed, were optimised using accurate measurements of the real flow-rate of the carrier gas into the GC system. All these options have been evaluated over the last 4 years. In order to demonstrate that omitting the retaining precolumn had no effect on the application range of the on-column interface, analytes as volatile as benzene were injected into GC-MS using 50-200 microl of n-pentane solutions. Contaminants were extracted from river water and wastewater into n-pentane using in-vial liquid-liquid extraction. The detection limits for benzene, toluene, ethylbenzene and m-xylene were approximately 10 ng/l. To obtain optimum results the SVE had to be closed 1 s before the end of evaporation. Several brands of n-pentane were analysed to check for the presence of benzene. Most of them contained interfering compounds and benzene at the low microg/l level and therefore had to be cleaned by means of column chromatography. As another example C8-C17 alkylphenones were extracted from wastewater with n-hexane. Detection limits were 10-40 ng/l.

Chromatography, Gas↗

Direct quantitation of volatile organic compounds in packaging materials by headspace solid-phase microextraction-gas chromatography-mass spectrometry.

The quantification of volatile organic compounds (VOCs) in flexible multilayer packaging materials using headspace solid-phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS) was studied. The analytes imclude 22 compounds such as aldehydes. ketones, carboxylic acids and hydrocarbons formed by thermooxidative degradation of polyethylene during the extrusion coating process in the manufacture of the packaging, and many of them are involved in the unpleasant and undesirable odour of these materials. External standard calibration using a solution of the analytes in an appropriate solvent was the first approach studied. Aqueous solutions of the analytes provided low reproducibility and the reduction of aldehydes to alcohols under the HS-SPME conditions. Hexadecane was chosen as the solvent since its polarity is similar to that of polyethylene and its volatility is lower than that of the analytes. However, hexadecane should be added to the sample before the analysis as it modifies the absorption capacity of the fibre. A 75-microm Carboxen-poly(dimethylsiloxane) fibre was used to extract the VOCs from the headspace above the packaging in a 15-ml sealed vial at 100 degrees C after 5 min of preincubation. The influence of the extraction time on the amount extracted was studied for a standard solution of the analytes in hexadecane, together with the influence of the volume of the standard solution and the amount of the sample placed in the vial. Standard addition and multiple HS-SPME were also studied as calibration methods and the results obtained in the quantitative analysis of a packaging material were compared.

Calibration↗

Use of solid-phase micro-extraction as a sampling technique in the determination of volatiles emitted by flowers, isolated flower parts and pollen.

The volatiles emitted by fresh whole flowers or isolated flower parts of mandarin, Citrus deliciosa Ten. (Rutaceae), were sampled using solid-phase micro-extraction (SPME). This technique offers several advantages over dynamic headspace sampling techniques used in previous investigations. In particular, SPME requires smaller sample sizes and very short sampling times, which can minimize the formation of artifacts due to damage to the plant, and contaminations or loss of compounds. This was especially applicable to the collection of volatiles from pollen.

Gas Chromatography-Mass Spectrometry↗

Headspace solid-phase microextraction analysis of volatile sulphides and disulphides in wine aroma.

Sulphur compounds (S-compounds) are important constituents of wine off-flavours. Headspace solid-phase microextraction (HS-SPME) combined with gas chromatography coupled to flame photometric detection (GC-FPD) was used to develop a suitable method to analyse volatile sulphides and disulphides. This is a very simple and fast technique which gives good reproducibility at microgram/l levels (relative standard deviations < 10%). The analytes were extracted from the headspace of the samples by using either polydimethylsiloxane or polyacrylate coated fused-silica fibers in an SPME unit. Then, the fiber was inserted into the injector of a gas chromatograph and the extracted S-compounds were thermally desorbed. The influence of different parameters, such as ionic strength, stirring, headspace volume, ethanol concentration, time and temperature of extraction, was studied. The extraction of the fibers varies considerably for the different sulphur compounds studied. The most volatile compounds were the least extracted by the coating fibers tested. The standard additions technique, applied to real samples, gave the recoveries > 94%. The detection limits range between 3 micrograms/l and 50 ng/l. The overall process was successfully applied to identify and quantify S-compounds in white and red wines.

Chromatography, Gas↗

Simultaneous measurement of volatile sulfur compounds using ascorbic acid for oxidant removal and gas chromatography-flame photometric detection.

A method for the simultaneous measurement of volatile sulfur compounds (COS, H2S, CS2, CH3SH, DMS) is established with preconcentration and GC-flame photometric detection (FPD). Prior to preconcentration of ambient air, it was necessary to remove SO2, water vapor and atmospheric oxidant. SO2 and water vapor were removed using a glass fiber filter and a cooled PTFE water trap loop, respectively. In order to remove atmospheric oxidant, the efficiency of an ascorbic acid scrubber was examined. It was found that an ascorbic acid scrubber enabled measurement of volatile sulfur compounds without adsorption and reaction loss. The detection limits for COS, H2S, CS2, CH3SH and DMS were 20, 34, 35, 263 and 44 pg of S, respectively.

Air↗

Automated gas chromatography with cryogenic/sorbent trap for the measurement of volatile organic compounds in the atmosphere.

An automated gas chromatographic system was constructed to easily adapt either the cryogenic trap or chemical sorbent trap for preconcentrating ambient levels of volatile organic compounds. Remarkable similarity in chromatograms from C3 to C10 was found between these two enrichment methods, except that the sorbent trap did not quantitatively trap the C2-hydrocarbons. In contrast to cryogenic trapping, the chromatographic conditions for more volatile compounds were substantially improved using the sorbent trap. Water interference on the porous-layer open tubular column was also better managed using the sorbent trap for the continuous analysis of humid room air. The similarity in peak profiles between the GC-flame ionization detection (FID) and a commercial GC-MS system, regardless of concentration levels, facilitated compound identification on the FID chromatograms based on a field mission involving analysis of 106 air samples.

Adsorption↗

Volatiles from rhizomes of Rhodiola rosea L.

Terpenes and aroma volatiles from rhizomes of Rhodiola rosea L. from Norway have been isolated by both steam distillation and headspace solid-phase micro-extraction coupled with gas chromatography and mass spectrometry analysis. The dried rhizomes contained 0.05% essential oil with the main chemical classes: monoterpene hydrocarbons (25.40%), monoterpene alcohols (23.61%) and straight chain aliphatic alcohols (37.54%). n-Decanol (30.38%), geraniol (12.49%) and 1,4-p-menthadien-7-ol (5.10%) were the most abundant volatiles detected in the essential oil, and a total of 86 compounds were identified in both the SD and HS-SPME samples. Geraniol was identified as the most important rose-like odour compound besides geranyl formate, geranyl acetate, benzyl alcohol and phenylethyl alcohol. Floral notes such as linalool and its oxides, nonanal, decanal, nerol and cinnamyl alcohol highlight the flowery scent of rose root rhizomes.

Acyclic Monoterpenes↗

Volatile organic components migrating from plastic pipes (HDPE, PEX and PVC) into drinking water.

High-density polyethylene pipes (HDPE), crossbonded polyethylene pipes (PEX) and polyvinyl chloride (PVC) pipes for drinking water were tested with respect to migration of volatile organic components (VOC) to water. The odour of water in contact with plastic pipes was assessed according to the quantitative threshold odour number (TON) concept. A major migrating component from HDPE pipes was 2,4-di-tert-butyl-phenol (2,4-DTBP) which is a known degradation product from antioxidants such as Irgafos 168(R). In addition, a range of esters, aldehydes, ketones, aromatic hydrocarbons and terpenoids were identified as migration products from HDPE pipes. Water in contact with HDPE pipes was assessed with respect to TON, and values > or =4 were determined for five out of seven brands of HDPE pipes. The total amount of VOC released to water during three successive test periods were fairly constant for the HDPE pipes. Corresponding migration tests carried out for PEX pipes showed that VOC migrated in significant amounts into the test water, and TON >/=5 of the test water were observed in all tests. Several of the migrated VOC were not identified. Oxygenates predominated the identified VOC in the test water from PEX pipes. Migration tests of PVC pipes revealed few volatile migrants in the test samples and no significant odour of the test water.

Manufactured Materials↗

Volatile organic compounds (VOCs) in urban atmosphere of Hong Kong.

The assessment of volatile organic compounds (VOCs) has become a major issue of air quality network monitoring in Hong Kong. This study is aimed to identify, quantify and characterize volatile organic compounds (VOCs) in different urban areas in Hong Kong. The spatial distribution, temporal variation as well as correlations of VOCs at five roadside sampling sites were discussed. Twelve VOCs were routinely detected in urban areas (Mong Kok, Kwai Chung, Yuen Long and Causeway Bay). The concentrations of VOCs ranged from undetectable to 1396 microg/m3. Among all of the VOC species, toluene has the highest concentration. Benzene, toluene, ethylbenzene and xylenes (BTEX) were the major constituents (more than 60% in composition of total VOC detected), mainly contributed from mobile sources. Similar to other Asian cities, the VOC levels measured in urban areas in Hong Kong were affected both by automobile exhaust and industrial emissions. High toluene to benzene ratios (average T/B ratio = 5) was also found in Hong Kong as in other Asian cities. In general, VOC concentrations in the winter were higher than those measured in the summer (winter to summer ratio > 1). As toluene and benzene were the major pollutants from vehicle exhausts, there is a necessity to tighten automobile emission standards in Hong Kong.

Air Pollutants↗

On the cytotoxicity of some microbial volatile organic compounds as studied in the human lung cell line A549.

The cytotoxicity of 13 microbial volatile organic compounds (MVOC) was studied using a human lung carcinoma epithelial cell line A549 in a colony formation assay and two colorimetric assays: the microculture tetrazolium assay (MTT assay) and the cellular protein assay (methylene blue-MB assay). For comparison, two known cytotoxic substances: the non-volatile mycotoxin gliotoxin and the mono-functional alkylating agent methyl methanesulfonate (MMS) were studied. Concentration-response curves for each agent were established and the IC50 value (concentration resulting in 50% inhibition of colony growth or absorbance) was estimated. There are differences in toxicity levels between the MVOC tested and gliotoxin and MMS. The most toxic MVOC was 1-decanol which was as effective as MMS in all test systems. 1-decanol was about 10-fold more toxic than the other MVOC. All MVOC tested were more than 1000-fold less toxic than gliotoxin.

Bacteria↗

Volatile and semivolatile organo-halogen trace analysis in surface water by direct aqueous injection GC-ECD.

A procedure for simultaneous determination of volatile and semivolatile chloroorganic compounds (from trichloromethane to di- and trichlorobenzenes to hexachlorobutadiene) in aqueous samples was developed. The procedure is based on a DAI-GC-ECD technique widely used for trihalomethanes determination in drinking water. The DAI technique application could have been extended to semivolatile chloroorganic compounds by using a Rtx-624 (60 m x 0.32 mm I.D., df 1.8 microns (6% cyanopropyl, 94% dimethyl polysiloxane). Precision (R.S.D.) and detection limits of the DAI-GC-ECD procedure with respect to 12 volatile and semivolatile chloroorganics were determined. Relative standard deviations (R.S.D.) were lower than 22% and the detection limits (concentration equivalent to a peak height three times the baseline noise) range from 0.02 microgram L-1 for trichloroethene and tetrachloroethene to 0.25 microgram L-1 for hexachlorobutadiene to 1.6 micrograms L-1 for 1,2-dichlorobenzene. The method was successfully used to determine chloroorganic pollutants in river water.

Chromatography, Gas↗

Analysis of volatile fatty acids in wastewater collected from a pig farm by a solid phase microextraction method.

The main purpose of this study is to develop a reliable Solid Phase Microextraction (SPME) method for monitoring the concentration of volatile fatty acid (VFA) in the wastewater collected from pig farms. Ten volatile fatty acid species were spiked in 2 ml of swine wastewater and extracted with a carbowax coated extraction fiber to evaluate the accuracy and precision of the method. The fiber was introduced into a gas chromatography system by thermal desorption and detected by a mass spectrometer detector. The estimated method detection limits ranged from 11.5 mM/L for formic acid to 0.03 mM/L for heptanoic acid. The method is more sensitive than the sample direct injection method. The percentage recovery of analytes ranged from 77.3 for propanoic acid to 114.1 for formic acid at the spike level of 19.09 mM/L. The compound absorption rate varied significantly with the fiber absorption time for n-Valeric, isocaproic, n-caproic and heptanoic acids. An SPME method with twenty minutes fiber absorption and three minutes thermal desorption was tested in this study and resulted in good reproducibility for analyzing VFAs in swine wastewater. The method may be applied for scanning a wide spectrum of polar organic compounds in environmental samples.

Acrylic Resins↗

Biogenic volatile organic compound emissions (BVOCs). I. Identifications from three continental sites in the U.S.

Vegetation composition and biomass were surveyed for three specific sites in Atlanta, GA; near Rhinelander, WI; and near Hayden, CO. At each research site emissions of biogenic volatile organic compounds (BVOCs) from the dominant vegetation species were sampled by enclosing branches in bag enclosure systems and sampling the equilibrium head space onto multi-stage solid adsorbent cartridges. Analysis was performed using a thermal desorption technique with gas chromatography (GC) separation and mass spectrometry (MS) detection. Identification of BVOCs covering the GC retention index range (stationary phase DB-1) from approximately 400 to 1400 was achieved (volatilities C4-C14).

Air Pollution↗

Volatile metabolites from mold growth on building materials and synthetic media.

Mold species which were isolated from damp buildings were grown on sterile building materials and some synthetic media in order to study the microbial volatile organic compounds produced. Patterns of the microbial volatile organic compounds (MVOC) were very media dependent but media which favor terpene biosynthesis may give patterns unique enough for identification of dominant indoor molds.

Air Pollutants↗