Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Torque”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83Linked to original sources

Effects of detraining following short term resistance training on eccentric and concentric muscle strength.

Healthy males were examined before and after 12 weeks of accommodated resistance training (three week-1) and after 12 weeks of detraining. Training consisted of four to five sets of six coupled maximum voluntary bilateral concentric and eccentric (Grp ECCON; n = 10) or 12 concentric (Grp CON; n = 8) quadriceps muscle actions. Concentric and eccentric peak torque at various constant angular velocities and three repetition maximum half-squat and vertical jump height were measured. Grp ECCON showed greater (P less than 0.05) overall increase in peak torque after training and detraining than Grp CON. Thus, concentric peak torque (0.52 rad s-1) increased more (P less than 0.05) over the experimental period in Grp ECCON and increases in eccentric peak torque were preserved in Grp ECCON only. Increases in peak torque in response to training were greater (P less than 0.05) at 0.52 than at 2.62 rad s-1. Alterations in the torque-velocity patterns induced by training remained after detraining in Grp ECCON but not in Grp CON. The retained increases (P less than 0.05) in half-squat were 12 and 18% in Grps CON and ECCON, respectively. Neither group showed increased vertical jump height after detraining. This study showed greater preservation of concentric and eccentric peak torque after detraining following coupled concentric and eccentric than concentric resistance training. Only the former regime induced a change in the shape of torque-velocity curves that was manifest after detraining.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Factors limiting force during slow, shortening actions of the quadriceps femoris muscle group in vivo.

Speed-torque relations of the quadriceps femors muscle group were determined using eight healthy subjects. Isometric or isovelocity, shortening muscle actions were performed at 15 speeds (0-6.28 rad s-1) and torque was measured 0.78 and 0.52 rad below horizontal. Unilateral actions were evoked by surface electrical stimulation or by maximal voluntary effort. Stimulation current evoked a torque equal to approx. 70% of maximal voluntary isometric and was held constant across speeds. For the voluntary or stimulation tests, torque decreased (P < 0.05) with increasing speed. This response in relative terms was greater (P < 0.05) for the stimulation than for the voluntary tests. The difference in the decline in relative torque for the simulation vs. voluntary tests was not influenced by the angle at which torque was measured, and thereby muscle length. Speed-torque data for the two stimulation tests fit a linearized plot of a hyperbolic relation for the higher tests speeds. When torque was measured at the greater joint angle (0.78 rad), and thereby longer muscle length, the equation was Po-P/V = Po 0.724-1.078 (P < 0.05, r2 = 0.95) for speeds greater than 0.70 rad s-1. For the shorter muscle length, the equation for data collected at speeds greater than 1.13 rad s-1 was Po-P/V = Po 0.467 + 4.61 (P < 0.05, r2 = 0.91). Inclusion of data for the next slower speed markedly compromised the 'fit' for either linear relation.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

A constant-velocity cycle ergometer for the study of dynamic muscle function.

A cycle ergometer has been designed to measure the force exerted on the pedal cranks during maximum effort at a variety of constant velocities. Preset crank velocities of 13-166 rpm are established by a controlled 3-hp motor and cannot be overcome by the subject. Torque is measured by strain gauges bonded to the crank shafts; peak torque, peak power, work, and average power are derived for each pedal cycle. Studies in 30 healthy male subjects established reproducibility and normal standards. During exercise for 45 s at a constant velocity of 60 rpm, there was a wide intersubject variation in both maximal torque (118-226 N . m) and the percentage decline in torque (27.2-52.0%). The decline in torque was inversely related to maximal O2 intake (r = 0.84). During short (10-s) periods of exercise at six crank velocities between 60-160 rpm, a linear inverse relationship between maximal peak torque and pedal crank velocity was observed. The peak torque-velocity relationship and the percentage decline in peak torque during 30 s exercise at 60, 100, and 140 rpm were reproducible within a given subject, the coefficient of variation was less than 10%.

Exercise Test↗

Age and gender comparisons of muscle strength in 654 women and men aged 20-93 yr.

To assess age and gender differences in muscle strength, isometric, concentric (Con), and eccentric (Ecc) peak torque was measured in the knee extensors at a slow (0.52 rad/s) and fast (3.14 rad/s) velocity in 654 subjects (346 men and 308 women, aged 20-93 yr) from the Baltimore Longitudinal Study of Aging. Regression analysis revealed significant (P < 0.001) age-related reductions in Con and Ecc peak torque for men and women at both velocities, but no differences were observed between the gender groups or velocities. Age explained losses in Con better than Ecc peak torque, accounting for 30% (Con) vs. 19% (Ecc) of the variance in men and 28% (Con) vs. 11% (Ecc) in women. To assess age and gender differences in the ability to store and utilize elastic energy, the stretch-shortening cycle was determined in a subset of subjects (n = 47). The older women (mean age = 70 yr) showed a significantly greater enhancement in the stretch-shortening cycle, compared with men of similar age (P < 0.01) and compared with younger men and women (each P < 0.05). Both men and women showed significant declines in muscle quality for Con peak torque (P < 0.01), but no gender differences were observed. Only the men showed a significant decline in muscle quality (P < 0.001) for Ecc peak torque. Thus both men and women experience age-related losses in isometric, Con, and Ecc knee extensor peak torque; however, age accounted for less of the variance in Ecc peak torque in women, and women tend to better preserve muscle quality with age for Ecc peak torque. In addition, older women have an enhanced capacity to store and utilize elastic energy compared with similarly aged men as well as with younger women and men.

Adult↗

Adaptive control for backward quadrupedal walking VI. metatarsophalangeal joint dynamics and motor patterns of digit muscles.

1. We compared the dynamics of the metatarsophalangeal (MTP) joint of the cat's hind paw and the motor patterns of two short and four long muscles of the digits for two walking forms, forward (FWD) and backward (BWD). Kinematic (angular displacements) data digitized from high-speed ciné film and electromyographic (EMG) data were synchronized and assessed for bouts of treadmill walking. Kinetic data (joint forces) were calculated from kinematic and anthropometric data with the use of inverse-dynamic calculations in which the MTP joint net torque was divided into gravitational, motion-dependent, ground contact (absent for swing), and muscle torque components. Swing-phase kinetics were calculated from treadmill steps and stance-phase kinetics from overground steps in which one hind paw contacted a miniature force platform embedded in the walkway. 2. The plantar angle at the intersection of the metatarsal and phalangeal segmental lines was used to measure MTP angular displacements. During swing for both walking forms, the MTP joint flexed (F) and then extended (E); however, the F-E transition occurred at the onset of FWD swing and at the end of BWD swing. For FWD walking, the MTP joint extended at a constant velocity during most of stance as the cat's weight rotated forward over the paw. During the unweighting phase at the end of stance, the MTP joint flexed rapidly before paw lift off. For BWD walking, the MTP joint extended briefly at stance onset (similar to a yield) and then flexed at a constant velocity as the cat's weight rotated backward over the paw. At the end of stance, the MTP joint extended and then flexed slightly as the paw was unweighted before paw lift off. 3. For both forms of walking, three of the six muscles tested were recruited just before paw contact and remained active for most (75-80%) of stance for both walking forms: plantaris (PLT), flexor hallucis longus (FHL), and flexor digitorum brevis (FDB). Their recruitment contributed to the flexor muscle torque at the MTP joint during most of FWD and BWD stance and was responsible for the absorption of mechanical power at the MTP joint for FWD stance and generation of mechanical power at the MTP joint during BWD stance. Also, the FHL and PLT, along with the soleus (SOL; also recorded in this study), contributed to an extensor muscle torque (described in paper IV of this series) and the generation of mechanical power at the ankle joint during stance of FWD and BWD walking. 4. The timing of activity for three muscles recruited during FWD swing was distinct for the two walking forms. The hallmark burst of the flexor digitorum longus (FDL)--a single burst, brief in duration and high in amplitude--occurred at the end of FWD swing (as the toes flexed rapidly) but shifted to the onset of BWD stance (as the claws protruded and toes extended) during paw weighting. The extensor digitorum longus (EDL) was recruited after paw off and was active for most of FWD swing; its activity contributed to an extensor muscle torque at the MTP joint and a flexor muscle torque at the ankle joint. For BWD walking, EDL recruitment shifted to an earlier phase in the step cycle and coincided with toe extension, which occurred at the end of stance before paw lift off. This pre-lift off activity continued into the first part of swing and contributed to an extensor muscle torque at the MTP joint and a flexor muscle torque at the ankle.(ABSTRACT TRUNCATED AT 250 WORDS)

Adaptation, Physiological↗

Hydroxyapatite-coated external fixation pins.

The aim of this review is to report on studies of hydroxyapatite-coated external fixation pins as a solution to enhance pin fixation. In a highly loaded animal study, three tapered pin types were compared: Type A uncoated, Type B coated with hydroxyapatite and Type C coated with titanium. There was a 13-fold increase in the extraction torque of Type B pins compared with Type A, and a twofold increase compared with Type C pins. Extraction torque was significantly lower compared with the corresponding insertion torque in both Types A (p < 0.001) and C (p = 0.003). Conversely, with the hydroxyapatite-coated pins there was no difference between extraction and insertion torque. In a clinical study of 76 external fixation pins in 19 patients treated with hemicallotasis for osteoarthritis on the medial side of the knee, pin insertion and extraction torque forces were measured. The patients were randomized to be treated with either standard tapered pins or tapered pins coated with hydroxyapatite. Extraction torque of the hydroxyapatite-coated pins was higher than the extraction torque of the standard pins in both cancellous and cortical bone (p < 0.005). In a prospective, randomized clinical study of osteoporotic wrist fractures, extraction torque of the coated pins was higher than with standard pins (p < 0.0001). These studies demonstrate that with the use of hydroxyapatite-coated pins, no deterioration of pin fixation occurs, and that there is no significant pin loosening and infection, regardless of bone type and loading conditions.

Animals↗

Optimal isokinetic loads and velocities producing muscular power in human subjects.

The torque values of the quadriceps muscles of 16 college football players were tested by means of an isokinetic dynamometer in order to determine the optimal loads and velocities producing muscular power. The men were tested at velocities ranging from 5 to 25 rpm and throughout a range of knee extension between the positions of 85 degrees to 50 degrees of knee flexion. Isometric measures were also recorded at corresponding angles. The muscular torque values recorded isokinetically at the various velocities were then compared to the isometric forces at the corresponding angles of knee extension to ascertain the arithemtic proportion of isokinetic to isometric torque which produced maximum muscular power. The results indicated that the proportionate values of isokinetic to isometric torque and isokinetic velocities which produced maximum power were not directly comparable to similar loads and velocities found in vitro. The weight of the leg may have contributed to submaximal isometric recordings, thus resulting in higher proportionate values of isokinetic to isometric force. Changes in these values as the knee was extended were deemed to be a result of variance in the isometric torque since the isokinetic torque stayed relatively constant throughout the range of movement. The data suggested that a plateau of isokinetic torque may have been reached in the production of maximum power. Maximum isokinetic torque values tended to shift to more extended joint positions as the speed of knee extension increased. This shift may have been due to the momentum of the leg during the faster isokinetic speeds overcoming some of the inertia of the weight of the leg as it was extended.

Adolescent↗

Isokinetic study of muscle strength in osteoarthritic knees of females.

The present investigation was aimed at assessing the difference in peak torque between normal and osteoarthritic (OA) knees in females. Fifty-five female osteoarthritic patients with 85 osteoarthritic knees were studied. Thirty-three normal females of similar age were also collected as a control group. The muscle torque of the knee flexor and extensor was assessed by a Cybex II dynamometer. The speed of isokinetic contraction was set at 30 RPM, 5 RPM, and 0 RPM. The muscle torque of the affected knee in patients with unilateral osteoarthritis was found to be significantly greater than that of those with bilateral osteoarthritis (p less than 0.05). The peak torque of OA patients at the faster speed (30 RPM) showed significant deterioration with age. Compared with the value for controls, the deficit of peak torque in geriatric patients was significant (p less than 0.05), especially at the faster speed (30 RPM). The decrease in extensor torque in OA knees tended to be greater than that of flexor torque, especially in patients less than 51 years of age at 5 RPM and 0 RPM. Age, duration of illness and the grading of X-ray change accounted for isokinetic torque differences in osteoarthritic knees.

Adult↗

Static pre-load effect on knee extensor isokinetic concentric and eccentric performance.

The effect of two static pre-load levels on isokinetic concentric (CON) and eccentric (ECC) performance of the knee extensors at 90 degrees.s-1 was evaluated in 35 healthy subjects. The low pre-load level was 50 N, and the high level was 75% of a maximal voluntary isometric contraction, performed at the start angles of 100 degrees (CON) and 30 degrees (ECC) of knee flexion. A two-way ANOVA with two repeated measures (load and angle) and a Newman-Keuls post hoc analysis were performed to compare the interaction of pre-load and angle at every 5 degrees in the ROM. The differences in average torque, peak torque, and peak torque angle between the pre-load levels were also analyzed with repeated-measures t-tests. The high pre-load condition had a significant increase in torque at 99, 95, 90, and 85 degrees concentrically and 31, 35, 40, 45, and 50 degrees eccentrically. In comparing the two pre-load conditions over the whole torque curve, there was a significant difference in average torque values of both CON and ECC, no significant difference in peak torque in either contraction, and a significant shift in peak torque angle with CON contractions only.

Adult↗

Torsional strength of the ankle in vitro. The supination-external-rotation injury.

Nineteen fresh-frozen anatomic specimens of the ankle were mounted in an experimental test device with the foot in supination. Torque versus rotation curves were recorded as each foot was rotated externally to failure. The mean failure torque was 45.3 Nm, the mean rotation to failure was 41.4 degrees, and the mean energy absorbed to failure was 10.6 Nm. Twelve specimens failed by fracture of the fibula, five by failure of lateral ligaments with no fibular fracture, one by a subtalar dislocation, and one by fracture of the calcaneous through a fixation screw hole. There were no statistically significant differences in torque or energy to failure between those specimens that failed by fibular fracture and those with ligamentous failure alone. Rotation to failure was 6 degrees greater in the ligamentous failure group. Ankles with less initial rotatory laxity tended to fail at higher torque levels. The mean ankle fracture torque measured in this study is similar to previously reported mean ligamentous failure torque for the knee flexed to 20 degrees and rotated externally to failure. In a prior in vivo study, approximately 10 Nm of external foot torque and 20 degrees of foot rotation could be tolerated prior to the initiation of pain. The present study indicates that these in vivo pain threshold levels represent approximately 50% of the rotation to failure and 25% of the torque to failure.

Ankle Injuries↗

The relationship between strength and function in females with juvenile rheumatoid arthritis.

OBJECTIVE: To describe the relationship between isokinetic concentric and eccentric quadriceps strength and function in females with juvenile rheumatoid arthritis (JRA). METHODS: Twenty girls with JRA aged 6 to 16 years participated in the study. Function and strength were measured on one occasion. Isokinetic concentric and eccentric quadriceps torque was measured on the Kin-Com dynamometer. Function was measured with the Childhood Health Assessment Questionnaire (CHAQ) and the Canada Fitness Award 50 m run. Pain and joint count were taken as measures of disease activity. Pain was assessed on a visual analog scale through parent- and self-report. Correlations between function, standardized torque values, pain, and joint count were determined. Stepwise multiple regression analyses with function as the predicted variable were performed. RESULTS: Correlations between standardized torque and CHAQ scores were moderate (r = -0.48, p = 0.03 for concentric torque and r = -0.43, p = 0.06 for eccentric). Correlations between torque and run scores were also moderate (r = -0.48, p = 0.03 for concentric, r = -0.31, p = 0.19 for eccentric). Pain and total joint count were the best predictors of CHAQ score (r2 = 0.80), while concentric torque was the best predictor of running ability (r2 = 0.23). CONCLUSION: Quadriceps torque was moderately correlated to function in girls with JRA. Function as determined on the CHAQ was best predicted from measures of disease activity, while function as determined on the 50 m run was best predicted from concentric quadriceps torque. Further research is required to determine a cause-effect relationship between strength and function in girls with JRA.

Adolescent↗

Mechanomyographic and electromyographic responses to stimulated and voluntary contractions in the dorsiflexors of young and old men.

The effect of age on mechanomyography (MMG) has not been examined for electrically evoked contractions. Similar to torque, we expected that postactivation potentiation of the MMG would differ between young and old subjects. Additionally, under voluntary conditions, we compared normalized MMG and electromyographic (EMG) signals in relation to torque, and expected that MMG, unlike EMG, would be affected by age. In 10 young and 10 old men, electrical stimulation was delivered before and after a 10-s maximal voluntary contraction (MVC) to assess potentiation of contractile (twitch torque; Pt), electrical (M-wave amplitude), and mechanical (MMG amplitude) properties of the dorsiflexors. Subsequently, subjects performed voluntary contractions at 20%, 40%, 60%, 80%, and 100% MVC for calculation of normalized MMG-torque and EMG-torque relationships. Following the MVC, Pt and evoked MMG were larger than at rest in both groups, but M-wave amplitude was unchanged. Twitch potentiation was greater in young than old, whereas evoked MMG was unaffected by age. Under voluntary conditions, values for MMG and EMG were similar between groups, except for greater MMG at MVC in young men. The shape of MMG and EMG relationships to torque was similar only in young men. Using the aging model, our results indicate that potentiation of the mechanical components (MMG) differ from those of twitch torque. Furthermore, the comparison of normalized voluntary MMG with age provides additional support for the concept of age-related motor unit remodeling.

Action Potentials↗

Prerequisites and limitations to isokinetic measurements in humans. Investigations on a servomotor-controlled dynamometer.

Physical and technical limitations have to be considered when measuring small torques over a wide range of angles during joint movements in humans using isokinetic methods, i.e. at constant angular velocities. In the concentric mode, during the initial phase, the subject must actively accelerate the lever of the isokinetic dynamometer to a present velocity. To guarantee an adequate duration of the isokinetic phase at high present velocities, greater torques are necessary to produce appropriate accelerations, otherwise the isokinetic phase will be increasingly shortened until the preset velocity can no longer be attained. The servomotor-controlled dynamometer used (LIDO-Active 2.1) continuously records torque during the whole movement, irrespective of differences between the actual and the preset velocity, but the user is not informed about which torques have been recorded outside the isokinetic phase and at which actual velocity. Thus, in the evaluation of torques in the nonisokinetic range, errors occur due to assigning torque measurements to incorrect velocities and due to the non-negligible accelerations involved. In exploratory tests on the dynamometer using physical methods to produce constant torques, an attempt has been made to ascertain the range over which isokinetic conditions were satisfied, hence providing a reliable basis for isokinetic studies in sports medicine and sports sciences.

Biomechanical Phenomena↗

Biomechanic changes in passive properties of hemiplegic ankles with spastic hypertonia.

OBJECTIVE: To investigate quantitatively biomechanic changes in the passive properties of hemiplegic spastic ankles. DESIGN: Evaluation of spastic hypertonia by moving the ankle joint slowly between dorsiflexion and plantarflexion extreme positions under controlled joint torque and position. SETTING: Institutional research center. PARTICIPANTS: Twenty-four stroke patients with spastic ankles and 32 healthy controls. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Passive resistance torque at controlled dorsiflexion and plantarflexion positions, dorsiflexion and plantarflexion range of motion (ROM) at controlled torques, and quasistatic stiffness and energy loss in dorsiflexion and plantarflexion. RESULTS: Spastic hypertonic ankles showed significant alterations of the passive properties in plantarflexion (P=.041) as well as in dorsiflexion (P=.016) directions. Compared with healthy controls, spastic ankles showed higher resistance torque (9.51+/-4.79Nm vs 6.21+/-3.64Nm, P=.016), higher quasistatic stiffness (.54+/-.19Nm/deg vs .35+/-.20Nm/deg, P=.001) at 10 degrees of dorsiflexion, larger normalized dorsiflexion energy loss (.068+/-.04J/deg vs .04+/-.02J/deg, P=.037), and decreased dorsiflexion ROM at 10Nm of resistance torque (10.77 degrees +/-8.69 degrees vs 20.02 degrees +/-11.67 degrees , P=.014). The resistance torque, ROM, and stiffness of spastic hypertonic ankles in plantarflexion showed similar changes (P<.05) to those in dorsiflexion. The passive ROM, joint stiffness, and resistance torque at controlled positions correlated with each other and also correlated with the Modified Ashworth Scale (P<.01). CONCLUSIONS: Various biomechanic changes in both plantar- and dorsiflexors are associated with spastic hypertonia of chronic stroke patients, and they can be evaluated quantitatively under well-controlled conditions. With simplifications, the various measures in this study can potentially be used to obtain more comprehensive and quantitative evaluations of spastic hypertonia in a clinical setting.

Analysis of Variance↗

Effects of keyswitch design and finger posture on finger joint kinematics and dynamics during tapping on computer keyswitches.

OBJECTIVE: To examine the effects of postural and keyswitch characteristics on musculoskeletal tissue loading during tapping on computer keyswitches. DESIGN: We hypothesized that joint torques, stiffness and work parameters differ across keyswitch designs and finger postures typical of those observed during computer keyboard typing. We experimentally measured joint kinematics and calculated joint torques while tapping on different keyswitches in different postures, and analyzed the data using mechanical impedance models. METHODS: Sixteen human subjects tapped with the index finger on computer keyswitches mounted on a sensor which measured vertical and horizontal forces. Miniature electro-optical goniometers mounted dorsally across each finger joint measured joint kinematics. Joint torques were calculated from endpoint forces and joint kinematics using an inverse dynamics algorithm. A linear spring-damper impedance model was fitted to joint torque, position, and velocity during the contact period of each tap. Subjects tapped in three postures approximating those employed during tapping on three rows of a computer keyboard, on four different keyswitches, resulting in 12 conditions. RESULTS: More extended finger posture was associated with greater joint torques, energies, and stiffnesses, despite minimal differences in endpoint forces across posture. Greater keyswitch make forces were associated with increased forces, joint torques and joint stiffnesses, however this relationship was not monotonic. CONCLUSIONS: Joint torques and stiffness parameters differed across keyswitch designs and finger postures. Estimates of joint impedance and work provided a unique perspective into finger dynamics. RELEVANCE: Determining the causes of work-related musculoskeletal disorders is facilitated by characterizing workplace task biomechanics, which can be linked to specific injury mechanisms.

Adult↗

Short vs. long length of rectus femoris during eccentric exercise in relation to muscle damage in healthy males.

BACKGROUND: We investigated the effects of short vs. long length of rectus femoris during eccentric exercise of similar range of motion on selected muscle damage indicators. METHODS: Using an isokinetic dynamometer at 1.05 rad/s, 12 healthy male [mean (standard deviation), 21 (2) years] volunteers randomly underwent two exercise sessions, one on each leg, 14 days apart. During each session, subjects had to accomplish 12 sets of 10 maximal voluntary efforts in seated and prone positions to achieve short and long length of rectus femoris, respectively. Muscle damage indicators [serum creatine kinase activity, delayed onset muscle soreness, range of motion, eccentric peak torque, concentric peak torque and isometric peak torque] were assessed pre-exercise and 24, 48, 72 as well as 96 h post-exercise. FINDINGS: Compared to baseline data, creatine kinase, delayed onset muscle soreness, and range of motion disclosed significant changes at all time points after both exercise sessions (P<0.05). However, these muscle damage indicators demonstrated greater changes following exercise at short compared to long length of rectus femoris (P<0.05). Torque assessments also revealed that nine out of 12 and only two out of 12 measurements decreased significantly following short and long length eccentric exercise of rectus femoris, respectively (P<0.05). Short length eccentric exercise resulted in greater torque declines compared to long length during concentric and isometric evaluations (P<0.05). No such differences were observed when torque changes were evaluated eccentrically. INTERPRETATION: Short length of rectus femoris eccentric exercise induces greater muscle damage and peak torque declines than the corresponding long length in healthy adults.

Adult↗

Mechanics of the taper integrated screwed-in (TIS) abutments used in dental implants.

The tapered implant-abutment interface is becoming more popular due to the mechanical reliability of retention it provides. Consequently, understanding the mechanical properties of the tapered interface with or without a screw at the bottom has been the subject of a considerable amount of studies involving experiments and finite element (FE) analysis. This paper focuses on the tapered implant-abutment interface with a screw integrated at the bottom of the abutment. The tightening and loosening torques are the main factors in determining the reliability and the stability of the attachment. Analytical formulas are developed to predict tightening and loosening torque values by combining the equations related to the tapered interface with screw mechanics equations. This enables the identification of the effects of the parameters such as friction, geometric properties of the screw, the taper angle, and the elastic properties of the materials on the mechanics of the system. In particular, a relation between the tightening torque and the screw pretension is identified. It was shown that the loosening torque is smaller than the tightening torque for typical values of the parameters. Most of the tightening load is carried by the tapered section of the abutment, and in certain combinations of the parameters the pretension in the screw may become zero. The calculations performed to determine the loosening torque as a percentage of tightening torque resulted in the range 85-137%, depending on the values of taper angle and the friction coefficient.

Bone Screws↗

Time-of-day effect on patella tendon stiffness alters vastus lateralis fascicle length but not the quadriceps force-angle relationship.

AIM: To examine the time-of-day (TOD) effect on torque-force/angle, fibre length (FL), tendon stiffness (K), stress, and strain using the quadriceps muscle-tendon complex as a model. METHODS: Twelve healthy young men (aged 27+/-2.0 years) were studied at AM (7h45) and PM (5h45). Maximal isometric contractions were carried out on an isokinetic dynamometer, with real-time recordings of vastus lateralis (VL) FL and patella tendon K using B-mode ultrasonography. Percutaneous electrical twitch doublets superimposed on maximal torque were used to test for muscle activation capacity (AC). RESULTS: At PM, torque and force increased by 16+/-3.0% (P<0.01) over 30-90 degrees knee angles. Where the load was standardised (at 250N) in order to discriminate between torque generation capacity and tendon K changes, PM relative to AM, there were 8% and 13% (P<0.01) reductions in relaxed and contracted FL, respectively. Average K decreased by 21% (P<0.001) and the maximal stress and strain were increased at PM by 11% and 16%, respectively (P<0.01). No TOD effect on AC was seen. CONCLUSION: The quadriceps torque or force-angle relationships shift upwards at PM vs. AM, with no shift in the position of the optimal knee angle. This torque or force increase appears not to be centrally modulated. Although K decreases with TOD thereby potentially shortening the working length of the sarcomeres, these changes overall do not affect the ability of the muscle to produce greater torque in the evening.

Adult↗