Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Spectral estimation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83Linked to original sources

Spectral electromyographic changes during a muscular strengthening training based on electrical stimulation.

The aim of this study is to describe the effects of neuromuscular electrical stimulation on electromyographic power spectrum evolution through a program of muscle strengthening. Ten healthy subjects received electrical stimulation of the quadriceps femoris muscle. Surface EMG was obtained from rectus femoris during maximum voluntary isometric contractions of quadriceps. Directly from EMG the Zero Crossing Rate and Root Mean Square (RMS) were calculated. Afterwards, the Mean Power Frequency and Median Frequency from EMG power spectrum were obtained using the Maximum Entropy method to estimate the spectrum. An analysis of variance for repeated measures revealed a statistical significance for RMS through the sessions and for spectral shifts towards higher frequencies between, before and after electrical stimulation. The evolution of power spectrum through sessions showed a curvilinear evolution, first decreasing towards lower frequencies and then increasing. These results suggest that electrical stimulation produces immediate changes on the motor unit: increasing the recruitment number and action potential velocity and a selective recruitment of type II fibres. During the strengthening program sessions two main phases were detected: the appearance and recovery from fatigue.

Adolescent↗

Fractal analyses of HRV signals: a comparative study.

In this paper, we have investigated the scaling behavior of the heart rate variability signals using the power spectral density (PSD), the discrete wavelet transform (DWT), and dispersive analysis (DA), and the maximum likelihood estimator (MLE) method. Results suggested the lowest variance for the MLE method, greatest variance for the PSD methods, the other methods somewhere in between.

Fractals↗

Modeling the judgment of vowel quality differences.

The hypothesis of this study is that the auditory cues relevant to listeners' judgment of vowel quality are a spectral representation of loudness density versus pitch. A model is described that generates such patterns for steady-state vowels. In addition to the nonlinear transformations underlying the loudness density and pitch scales, it incorporates experimentally established characteristics associated with frequency resolution and masking, such as the critical band concept. This model is combined with a measure of auditory perceptual distance which, operating on pairs of vowels, treats each stimulus representation as a single spectral shape. In order to test the distance metric and the model, experimental data were gathered from listeners' numerical estimates of quality differences between stimulus pairs which compared four-formant and two-formant vowels. The correlation between experimental and theoretical results was 0.89. We interpret this value to indicate that the present definition of auditory cue and auditory distance can be said to account for the experimental behavior of our listeners only in a rather gross fashion. On the other hand, the theory was developed on the basis of rather conservative assumptions about the nature of auditory cues. For instance, the model ignores the possibility of temporal coding and certain nonlinear effects, and it does not pay special attention to spectral peaks. Seen in that light, the agreement between observed and predicted auditory distance is remarkably good.

Auditory Perception↗

Packing characteristics of highly unsaturated bilayer lipids: Raman spectroscopic studies of multilamellar phosphatidylcholine dispersions.

The thermotropic properties and acyl chain packing characteristics of multilamellar dispersions of highly unsaturated lipids were examined by Raman spectroscopy. Bilayer assemblies were composed of POPC (1-palmitoyl-2-oleoylphosphatidylcholine), PAPC (1-palmitoyl-2-arachidonylphosphatidylcholine), and PDPC (1-palmitoyl-2-docosahexaenoylphosphatidylcholine), lipid systems possessing saturated sn-1 chains and unsaturated sn-2 chains with one, four, and six double bonds, respectively. Raman spectra were recorded in the acyl chain 2800-3100-cm-1 carbon-hydrogen (C-H) stretching and 1100-1200-cm-1 carbon-carbon (C-C) stretching mode regions, spectral intervals reflecting both the inter- and intrachain order/disorder properties of the various lipid dispersions. In order to obtain C-H stretching mode spectra relevant solely to the sn-1 chains of PAPC and PDPC, liquid-phase spectra of arachidonic and docosahexaenoic acid, respectively, were subtracted from the observed phospholipid spectra. The unsaturated sn-2 chains of PAPC and PDPC undergo minimal conformational reorganizations as the bilayers pass from the gel to liquid-crystalline phases. Phase transition temperatures, Tm, derived from statistically fitting the temperature-dependent Raman spectral data are approximately -2.5, -22.5, and -3 degrees C for POPC, PAPC, and PDPC, respectively. As the degree of unsaturation increases from POPC to PAPC and PDPC, the cooperativity of the phase transition, as measured by its breadth, decreases. Estimates of the transition widths from the temperature profiles are approximately 15 degrees C for PAPC and 20 degrees C for PDPC. The behavior of various Raman spectral parameters for the lipid gel phase reflects the formation of lateral microdomains, or clusters, whose packing properties maximize the van der Waals interactions between sn-1 chains.(ABSTRACT TRUNCATED AT 250 WORDS)

Crystallography↗

Limited resolution of spectral contrast and hearing loss for speech in noise.

This paper examines the relations among the spectral contrast needed for speech intelligibility, hearing loss for speech in noise, and auditory filter bandwidth. Fifteen hearing-impaired listeners with relatively flat, mild-to-moderate sensorineural losses and eight normal-hearing listeners participated in the study. The spectral contrast needed for speech intelligibility was determined by reducing spectral contrast in the speech signal and measuring the reduction in contrast beyond which the speech-reception threshold (SRT) for sentences in noise increases. Reduction of spectral contrast was accomplished by smearing the envelope of the squared short-time fast Fourier transform by a convolution with a Gaussian-shaped filter, and overlapping additions to reconstruct a continuous signal. Auditory filter bandwidth was determined by estimating auditory filter shapes at center frequencies of 0.8, 1.6, and 3.2 kHz, using a notched-noise masking paradigm. The results show that limited resolution of spectral contrast is only loosely associated with hearing loss for speech in noise. Moreover, the correlations between the SRT for unsmeared speech and the auditory filter bandwidth at various frequencies were weak.

Acoustic Stimulation↗

Proximal isovelocity surface area (PISA) as a noninvasive method for the estimation of the shunt quantification in perimembranous ventricular septal defects.

This study was designed to assess the reliability of the proximal isovelocity surface area (PISA) method for the estimation of shunt quantification in perimembranous ventricular septal defects (PVSD). The study group was composed of 30 patients (age 11 +/- 7 years, 13 female) with PVSD. The shunt flow (Qp-Qs) and the ratio of the pulmonary flow to the systemic flow (Qp/Qs) were calculated by spectral Doppler and catheterization. The Qp-Qs, the defect area (DA), and the shunt volume (SV) were obtained by the PISA method. The PISA method estimated the DA (cm(2)/m(2)), the SV (cm(3)/m(2)), and the Qp-Qs (L/min/m(2)) to be equal to (2 x pi x R(2) x NL)/(V(max) x Body surface area), DA x TVI(shunt), and to SV x Heart rate, respectively (R is the distance of the maximal PISA from the first aliasing line to the left ventricular side of the defect, NL is the nyquist limit, and V(max) and TVI(shunt) are the peak velocity and time-velocity integral of transdefect Doppler tracing obtained by continuous-wave Doppler). The PISA method (3.4 +/- 1.5 L/min/m(2)) underestimated the Qp-Qs according to spectral Doppler (r = 0.96, P < 0.001; mean difference -0.74 +/- 0.61 L/min/m(2); SEE = 0.11 L/min/m(2), P < 0.001) and catheterization (r = 0.92, P < 0.001; mean difference -0.45 +/- 0.7 L/min/m(2); SEE = 0.13 L/min/m(2), P < 0.001). The correlations between the PISA findings (Qp-Qs, DA, SV) and the catheterization Qp/Qs (r = 0.86, 0.84, and 0.86; P < 0.001, respectively), or between these and the spectral Doppler Qp/Qs (r = 0.80, 0.80, and 0.79; P < 0.001, respectively) were significant. The accuracies of the PISA findings in identifying large defects were high (0.90, 0.93, and 0.90 for cut-off values of Qp-Qs = 3.67 L/min/m(2), DA = 0.44 cm(2)/m(2), and SV = 43 cm(3)/m(2), respectively). As a result, the PISA method can be a simple and reliable alternative to the spectral Doppler method in the identification of large shunts in PVSD.

Adolescent↗

Measurement of thermal contribution to photoreceptor sensitivity.

Activation of a visual pigment molecule to initiate phototransduction requires a minimum energy, Ea, that need not be wholly derived from a photon, but may be supplemented by heat. Theory predicts that absorbance at very long wavelengths declines with the fraction of molecules that have a sufficient complement of thermal energy, and that Ea is inversely related to the wavelength of maximum absorbance (lambda(max)) of the pigment. Consistent with the first of these predictions, warming increases relative visual sensitivity to long wavelengths. Here we measure this effect in amphibian photoreceptors with different pigments to estimate Ea (refs 2, 5-7) and test experimentally the predictions of an inverse relation between Ea and lambda(max). For rods and 'red' cones in the adult frog retina, we find no significant difference in Ea between the two pigments involved, although their lambda(max) values are very different. We also determined Ea for the rhodopsin in toad retinal rods--spectrally similar to frog rhodopsin but differing in amino-acid sequence--and found that it was significantly higher. In addition, we estimated Ea for two pigments whose lambda(max) difference was due only to a chromophore difference (A1 and A2 pigment, in adult and larval frog cones). Here Ea for A2 was lower than for A1. Our results refute the idea of a necessary relation between lambda(max) and Ea, but show that the A1 --> A2 chromophore substitution decreases Ea.

Animals↗

Modeling the spatiotemporal organization of velocity storage in the vestibuloocular reflex by optokinetic studies.

1. A generalized three-dimensional state space model of visual vestibular interaction was developed. Matrix and dynamical system operators associated with inputs from the semicircular canals, otolith velocity estimator, and the visual system have been incorporated into the model, which focus on their relationship to the velocity storage integrator. 2. A relationship was postulated between the eigenvalues and the direction of the eigenvectors of the system matrix and the orientation of the spatial vertical. It was assumed that the system matrix for a tilted position was a composition of two linear transformations of the system matrix for the upright position. One transformation modifies the eigenvalues of the system matrix, whereas another rotates the eigenvectors of the system matrix. The pitch and roll eigenvectors rotate with the head, whereas the yaw axis eigenvector remains approximately spatially invariant. 3. Based on the three-dimensional model, a computational procedure was formulated to identify the eigenvalues and eigenvectors of the system matrix with the use of a modification of the marquardt algorithm. With the use of data obtained from a monkey, it was shown that the three-dimensional behavior of velocity storage cannot be predicted solely in terms of its time constants, i.e., the inverse of its eigenvalues. With the use of the same eigenvalues the data could either be fit or not fit, depending on the eigenvector directions. Therefore, it is necessary to specify eigenvector directions when characterizing velocity storage in three dimensions. 4. Parameters found with the use of the Marquardt algorithm were incorporated into the model. Diagonal matrices in a head coordinate frame were introduced for coupling the visual system to the integrator and to the direct optokinetic pathway. Simulations of optokinetic nystagmus (OKN) and optokinetic after-nystagmus (OKAN) were run. The model predicted the behavior of yaw and pitch OKN and OKAN when the animal is upright. It also predicted the cross-coupling in the side down position. The trajectories in velocity space were also accurately simulated. 5. One of the predictions of the model is that when the stimulus direction is along an eigenvector, the trajectory in velocity space is a straight line. Using the "spectral width" of the residuals from a straight line sequence during OKAN, we developed a methodology to estimate how close the OKAN decay was to an eigenvector trajectory. 6. Thus we have developed a model-based approach for studying and interpreting the response characteristics of velocity storage in three dimensions.(ABSTRACT TRUNCATED AT 400 WORDS)

Algorithms↗

Extrapolation of time series of EMG power spectrum parameters in isometric endurance tests of trunk extensor muscles.

The aim of the present study was to test the viability of using short isometric contractions of trunk extensor muscles to perform an assessment of their endurance capacity. To this aim two types of analysis were performed. First, electromyographic (EMG) mean power frequency (MPF) slopes with respect to time as estimated over shorter fixed periods were compared to slopes estimated over the full contraction period of a contraction sustained until the endurance time. Second, the relationship between MPF slope estimates as estimated over various periods and the endurance time of the muscle group was evaluated. Five subjects performed three isometric trunk endurance tests at 25%, 50% and 75% of their maximum voluntary contraction (MVC), respectively. EMG signals of the left and right multifidus, iliocostalis and longissimus muscles were continuously recorded and spectral parameters were calculated. The MPF appeared to decrease consistently during all endurance tests. The extrapolation from a MPF time series of half the estimated contraction period to the time series of the complete contraction period gave reasonable results at all force levels, when data from several electrode locations were incorporated in a single slope estimate (mean or steepest slope). The accuracy of the prediction of trunk extensor endurance on the basis of these parameters describing the MPF time series over half the estimated contraction period was satisfactory. Endurance time predictions from yet shorter periods were unreliable.

Adult↗

UV Raman spectral intensities of E. coli and other bacteria excited at 228.9, 244.0, and 248.2 nm.

Resonance Raman spectral intensities per average bacterial cell have been measured quantitatively for Gram-negative Escherichia coli, Citrobacter freundii, and Enterobacter aerogenes, as well as Gram-positive Bacillus subtilis and Staphylococcus epidermidis. Spectra have been obtained from cultures in the lag, log, and stationary growth phases excited in turn by 228.9, 244.0, and 248.2 nm light. Although Raman spectral peak positions (cm(-1)) excited by a given wavelength are very similar for all five bacterial species, the organisms are characterized by significantly different spectral intensity values. Intensity changes are associated with growth phase changes in all of the species as well. A comparison of measured with estimated average intensities has been made for spectra of log-phase E. coli. It is possible to compare measured intensities with intensities estimated for log-phase E. coli on the basis of the knowledge of its known average cellular molecular composition. A significant degree of hypochromism is observed in E. coli nucleic acid spectra. In contrast, strong average hyperchromism characterizes all aromatic amino acid peaks belonging to the same E. coli cells. Results suggest that knowledge of spectral intensity values will enhance significantly the capability to identify bacteria by means of their UV resonance Raman spectra.

Bacillus subtilis↗

Biocompatible polyester macroligands: new subunits for the assembly of star-shaped polymers with luminescent and cleavable metal cores.

The synthesis of a series of star-shaped, biocompatible polyesters--polylactides (PLAs), polycaprolactones (PCLs), and various copolymer analogues--with either labile iron(II) tris-bipyridyl or luminescent ruthenium(II) tris-bipyridyl cores is described. These polymers were readily assembled by a convergent, metal-template-assisted approach that entailed the synthesis of bipyridine (bpy) ligands incorporating PLA- and PCL-containing arms and subsequent chelation of the "macroligands" to iron(II) or ruthenium(II). Specifically, the polyester macroligands bpyPLA(2) and bpyPCL(2) were prepared by a stannous octoate catalyzed ring-opening polymerization of DL- or L-lactide and epsilon-caprolactone, using bis(hydroxymethyl)-2,2'-bipyridine as the initiator. Copolymers bpy(PCL-PLA)(2) and bpy(PLA-PCL)(2) were generated in an analogous manner using bpyPLA(2) and bpyPCL(2) as macroinitiators. Polymers with narrow molecular weight distributions and with molecular weights close to values expected based upon monomer/initiator loading were produced. The macroligands were subsequently chelated to iron(II) to afford six-armed, iron-core star polymers, which were characterized by UV-vis and (1)H NMR spectroscopy. Estimated chelation efficiencies for formation of the star polymers (M(n) calcd: 20-240 kDa) were high, as determined by UV-vis spectral analysis. Within the molecular weight range investigated, differential scanning calorimetry and thermogravimetric analysis revealed that the small amounts of metal in the polyester stars and differences in polymer architecture had little effect on the thermal properties of the PLA/PCL materials. However, thin films of the red-violet colored iron-core stars exhibited reversible, thermochromic bleaching. Solutions and films of the polymers also responded (with color loss) to a variety of chemical stimuli (e.g., acid, base, peroxides, ammonia), thus revealing potential for use in diverse sensing applications. Likewise, the polyester macroligands were chelated to ruthenium(II) to produce both linear and star-shaped polymers, which were characterized by UV-vis and (1)H NMR spectral analysis. Molecular weights of the polymers were determined by gel permeation chromatography (M(n)(MALLS): 6-30 kDa) with in-line, UV-vis diode-array detection, confirming the presence of the [Ru(bpy)(3)](2+) core in the eluting polymer fractions. As was the case with the corresponding iron-core polyesters, estimated chelation efficiencies were high.

Biocompatible Materials↗

High-resolution imager for digital mammography: physical characterization of a prototype sensor.

The physical performance characteristics of a high-resolution sensor module for digital mammography were investigated. The signal response of the imager was measured at various detector entrance air kerma and was found to be linear. The spatial resolution was determined by measuring the presampling modulation transfer function, MTF(f), of the system. The noise power spectra, NPS(f), of the system were estimated using 26 kVp: Mo/Mo, 28 kVp: Mo/Rh and 30 kVp: Rh/Rh, with polymethyl methacrylate (PMMA) 'tissue equivalent material' of thickness 20, 45 and 57 mm for each of three x-ray spectra at detector entrance air kerma in the range between approximately 80.2 and 92.3 microGy. The noise equivalent quanta, NEQ(f), and detective quantum efficiencies, DQE(f), for the various spectral conditions were computed. In addition, dose dependence of NPS(f) and DQE(f) was studied at various detector entrance air kerma ranging from 9.4 to 169.7 microGy. A spatial resolution of about 10 cycles mm(-1) was obtained at the 10% MTF(f) level. A small increase in NEQ(f)was observed under higher energy spectral conditions while the DQE(f) decreased marginally. For a given spectrum, increasing PMMA filtration produced negligible change in DQE(f). The estimated DQE values at zero frequency were in the range between 0.45 and 0.55 under the conditions investigated in this study.

Equipment Design↗

Static and dynamic myoelectric measures of shoulder muscle fatigue during intermittent dynamic exertions of low to moderate intensity.

Despite extensive research on muscular fatigue during prolonged static efforts, there have been relatively few studies of more complex tasks (dynamic and intermittent). A laboratory study of overhead work tasks was conducted to investigate whether electromyographic (EMG) measures can potentially serve as indicators of fatigue, particularly for ergonomic tasks analysis. Sixteen participants performed the tasks until they either developed substantial discomfort or reached a 3-h limit. EMG signals were obtained at intervals throughout the experiment from four shoulder muscles, both statically (during fixed-level test contractions) and dynamically (during task performance). Both EMG root mean square (RMS) amplitude and spectral content (mean and median power frequencies) were examined and compared in terms of their variability and sensitivity. In addition, a new fatigue index was developed to allow for the estimation of substantial fatigue onset. Variability was found to differ significantly between muscles and EMG measures, and was generally lowest for mean power frequencies obtained during static test contractions. Sensitivity was typically greatest for RMS versus spectral measures, and slightly higher for median than mean power frequencies. The results suggest that fatigue during dynamic tasks, while a complex phenomenon, can be monitored and quantified using EMG.

Adolescent↗

Qscore: an algorithm for evaluating SEQUEST database search results.

A scoring procedure is described for measuring the quality of the results for protein identifications obtained from spectral matching of MS/MS data using the Sequest database search program. The scoring system is essentially probabilistic and operates by estimating the probability that a protein identification has come about by chance. The probability is based on the number of identified peptides from the protein, the total number of identified peptides, and the fraction of distinct tryptic peptides from the database that are present in the identified protein. The score is not strictly a probability, as it also incorporates information about the quality of the individual peptide matches. The result of using Qscore on a large test set of data was similar to that achieved using approaches that validate individual spectral matches, with only a narrow overlap in scores between identified proteins and false positive matches. In direct comparison with a published method of evaluating Sequest results, Qscore was able to identify an equivalent number of proteins without any identifiable false positive assignments. Qscore greatly reduces the number of Sequest protein identifications that have to be validated manually.

Algorithms↗

Detection of aortic porcine valve dysfunction by maximum entropy spectral analysis.

A high-resolution method of spectral analysis, of the class generally called "maximum entropy method," was used in a study of aortic porcine valve closing sounds in 37 patients (ages 19 to 76). Spectra from 27 normal xenografts, implanted from 2 weeks to 61 months previously, were characterized by a dominant frequency peak, F1, at 89 +/- 15 Hz (mean +/- SD), with a lower amplitude peak, F2, at 154 +/- 25 Hz. Eight of nine patients with aortic porcine valve dysfunction were proved surgically to have leaflet degeneration or infection and had either F1 (139 +/- 54 Hz) and/or F2 (195 +/- 74 Hz) significantly higher than normal (p less than .001). In two patients with paravalvar leak but no leaflet abnormality, F1 and F2 were in the normal range. Estimation of F1 and F2 was highly reproducible and was unaffected by duration of implant up to 5 years. Spectral analysis of aortic porcine valve closing sounds by the maximum entropy method may be useful for detection of intrinsic xenograft dysfunction.

Adult↗

Classification of human liposarcoma and lipoma using ex vivo proton NMR spectroscopy.

Prognostication in patients with liposarcoma is a complex and controversial subject based on recognition of lipoblasts, adipocyte nuclear atypia, and qualitative estimations of cellularity and cell size. We show here that for 30 patients with liposarcoma and 5 patients with lipoma, spectral differences on high-resolution, magic angle spinning proton nuclear magnetic resonance (hr-MAS 1H-NMR) spectroscopy relate to known biochemical changes and correlate with adipocyte tissue differentiation, histologic cell type, and cellularity. The NMR-visible level of triglyceride is shown to correlate with liposarcoma differentiation, since the triglyceride level in well-differentiated liposarcoma is 33-fold higher on average than for myxoid/round cell liposarcoma, which in turn is 6-fold higher than the dedifferentiated and/or pleomorphic subtypes. The NMR-visible phosphatidylcholine level serves as an estimate of total tissue cell membrane phospholipid mass and was found to correlate with liposarcoma subtype. Pleomorphic liposarcoma, the most aggressive and metastatic subtype, was found to have a threefold increase in NMR-visible phosphatidylcholine level compared with dedifferentiated liposarcoma. The level of NMR-visible phosphatidylcholine was twofold greater in well-differentiated liposarcoma compared with lipoma and was threefold larger for the hypercellular myxoid/round cell subtype compared with the pure myxoid histology. Thus, NMR-derived parameters of tissue lipid may be used for objective distinction of liposarcoma histologic subtype/grade and lipoma from liposarcoma. These biochemical parameters may ultimately improve prognostication in patients with liposarcoma.

Humans↗

Electron probe microanalysis (EPMA) measurement of thin-film thickness in the nanometre range.

The thickness of thin films of platinum and nickel on fused silica and silicon substrates has been determined by EPMA using the commercial software STRATAGEM for calculation of film thickness. Film thickness ranged in the order 10 nm. An attempt was made to estimate the confidence range of the method by comparison with results from other methods of analysis. The data show that in addition to the uncertainty of the spectral intensity measurement and the complicated fitting routine, systematic deviation caused by the underlying model should be added. The scattering in the results from other methods does not enable specification of a range of uncertainty, but deviations from the real thickness are estimated to be less than 20%.

Journal Article↗

Statistical data evaluation in mobile gamma spectrometry: an optimization of on-line search strategies in the scenario of lost point sources.

There is a potential risk that hazardous radioactive sources could enter the environment, e.g., via satellite debris, smuggled radioactive goods, or lost metal scrap. From a radiation protection point of view there is a need for rapid and reliable methods for locating and identifying sources. The methods could also be used to locate hot spots after radioactive fallout. Carborne and airborne gamma spectrometry systems are suitable for the task. This work focuses on a situation where the radionuclide to search for is known, which is not an unlikely scenario. The possibility that the source is located near a road can be high, and thus motivating a carborne spectrometer system. The main object is to optimize on-line statistical methods in order to achieve a high probability for locating the point source and still have reasonably few false alarms caused by variations in the natural background radiation. Data were obtained from a carborne 3-L NaI(Tl) detector and two point sources located at various distances from the road. The nuclides used were 137Cs and 131I. Spectra were measured stationary on the road. From these measurements we have reconstructed counts in spectral windows applicable to different speed and sampling times; the time 3 s and speeds 32 and 54 km h(-1) are used in this work. The maximum distance a source can be located from the road and still be detected is estimated with four different statistical analysis methods. This distance is called the critical distance, CD. The method is applied on gross counts in the full energy peak spectral window. For each method alarm levels have been calculated from background data obtained in Scania (Skåne), in the south of Sweden. The results show large differences in CD. With the best approach, the two sources could be detected from about 180 m (137Cs, 6 GBq) and 170 m (131I, 4.5 GBq).

Automobiles↗