Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Separation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83Linked to original sources

Two-dimensional micro-separation technique for proteins and peptides, combining isoelectric focusing and gel gradient electrophoresis.

The two-dimensional combination of gel electrofocusing and gel gradient electrophoresis yields separate information about differences in net charge and molecular weight of macro-ions. A micro-version of this technique is described. The first dimension electrofocusing run is performed in cylindrical polyacrylamide gel of capillary size, using xylene cyanole FF as a reliable marker dye to indicate the final separation stage when proteins reach their isoelectric points. In the second-dimension run the focused proteins are separated in a continuous slab gel gradient of less than stamp size with total acrylamide concentration ranging from ca. 1% to more than 40%. Spreading of peaks in the gradient slab gel is shown to be related to the approach of protein to its pore limit in the gel. This spreading is a useful indicator of the final position of a protein in the gel if molecular weights are estimated according to the separation pattern in the gradient gel. The method described has been developed for the separation of proteins extracted from large single cells (i.e., neurons of the mollusc Aplysia californica.

Electrophoresis, Polyacrylamide Gel↗

Analysis of Dns-amino acids by liquid chromatography. I. Selection of optimum mobile phase composition for separation of Dns-amino acids on polyvinyl acetate gel.

The separation of a mixture of ten Dns-amino acids (Gns-Gly, -Ala, -Val, -Leu, -Pro, -Hypro, -Met, -Ser, -Asn and -Gln) was carried out by liquid chromatography by using macroreticular polyvinyl acetate gel as a packing material. Different mobile phase systems were investigated, based mainly on mixtures of n-hexane with ethanol, methanol, chloroform, acetone, methyl ethyl ketone, ethyl acetate, dioxane and tetrahydrofuran. The solvent composition was fixed so as to elute all of the components of the sample mixture in a practical period of 2 h. Satisfactory separation of the ten components was obtained with the n-hexane-ethanol (90:10) system. The presence of methanol as a modifier in the n-hexane was effective in reducing the elution time, but the separation was not as satisfactory. Chloroform or dioxane was useful only for the separation of Ser, Asn and Gln. Acetone, methyl ethyl ketone, ethyl acetate and tetrahydrofuran were not suitable for practical separations of Dns-amino acids.

Amino Acids↗

Separation of amino- and acetylamino-polycyclic aromatic hydrocarbons by reversed- and normal-phase high-performance liquid chromatography.

In the field of chemical carcinogenesis, amino- and acetylamino-polycyclic aromatic hydrocarbons (PAHs) are among the most studied compounds. Many of these compounds have recently been detected in the environment. Presently, knowledge permitting predictions of the high-performance liquid chromatographic (HPLC) retention order of amino- and acetylamino-PAHs, particularly among their geometric isomers is lacking. In order to obtain a better understanding of the separation of these types of compounds, we have studied the separation of a series of structurally related amino- and acetylamino-PAHs derived from naphthalene, phenanthrene, anthracene, pyrene, benz[a]anthracene, benzo[a]pyrene, and benzo[e]pyrene by using reversed-phase and normal-phase HPLC columns of different types (monomeric, polymeric, and chiral stationary phase). The results indicate: (i) Pirkle-type chiral stationary phase columns and the Zorbax SIL column can efficiently separate both the amino-PAHs and acetylamino-PAHs; (ii) in general, there was no correlation between retention time and molecular size; (iii) when acetylamino-PAHs were separated on the monomeric Zorbax ODS column, the isomer with the acetylamino group located at the carbon position of higher electron density has a shorter retention time; and (iv) separation of the parent PAHs was better than that of the amino-PAHs and acetylamino-PAHs. Our results thus may provide useful information for the analysis of amino-PAHs, particularly for distinguishing the geometric isomers of environmental samples.

Amines↗

Separation of carotenol fatty acid esters by high-performance liquid chromatography.

Employing isocratic and gradient-elution high-performance liquid chromatography (HPLC) a number of straight-chain fatty acid esters (decanoate, laurate, myristate, palmitate) of violaxanthin, auroxanthin, lutein, zeaxanthin, isozeaxanthin, and beta-cryptoxanthin, prepared by partial synthesis, have been separated on a C18 reversed-phase column. Several chromatographic conditions were developed that separated a mixture of di-fatty acid esters (dimyristate, myristate palmitate mixed ester, dipalmitate) of violaxanthin, auroxanthin, lutein, and zeaxanthin in a single chromatographic run. Hydroxycarotenoids such as lutein, zeaxanthin, and isozeaxanthin that are not easily separated by HPLC on C18 reversed-phase columns, can be readily separated after derivatization with fatty acids and chromatography of their esters. Chromatographic conditions for optimum separation of carotenoids from various classes are discussed.

Carotenoids↗

Capillary electrophoretic separation of protease inhibitors used in human immunodeficiency virus therapy.

The scope of this work was to investigate the migration behavior of the currently used protease inhibitors for antiretroviral therapy of people infected with the human immunodeficiency virus and to develop a method for their capillary electrophoretic separation and determination. All of the protease inhibitors (indinavir, saquinavir, nelfinavir, amprenavir, and ritonavir) contain at least one basic amino functional group. As a consequence, they can be separated by capillary zone electrophoresis using acidic buffer electrolytes. A fast electroosmotic flow is established in order to increase separation speed, by adding a cationic electroosmotic flow modifier to the electrolyte. After using conventional serum pretreatment procedures it is possible to separate all five protease inhibitors within less than 5 min. In addition, a non-aqueous CE method is also presented which enables the separation of three protease inhibitor compounds within less than 3 min.

Electrophoresis, Capillary↗

Separation of chondroitin sulfate and hyaluronic acid fragments by centrifugal precipitation chromatography.

Centrifugal precipitation chromatography (CPC) was applied for the first time to the separation of fragments of chondroitin sulfate (ChS) and hyaluronic acid (HA). The separation was performed using a gradient elution system between ethanol and water since solubility of these biopolymers highly depends on the concentration of ethanol in aqueous solution. ChS and HA were each eluted into several peaks through a flow-through UV detector at 275 nm, despite they have almost no absorbance at this wavelength in an aqueous solution. The separation was also confirmed by redissolving the dried fraction in water and measuring the absorbance at 210 nm. These results suggest that the CPC system can detect small precipitates of these biopolymers by light scattering at 275 nm. The separated fragments of biopolymers are not easily characterized because no suitable analytical method is available for identification of these compounds. However, the overall results demonstrate that CPC may be a useful separation of biopolymers such as glycosaminoglycans which quantitatively produce precipitates in an organic solvent mixture.

Centrifugation↗

Effect of glycerol-induced DNA conformational change on the separation of DNA fragments by capillary electrophoresis.

The effect on DNA separation of adding glycerol to the running buffer was studied using linear polyacrylamide (LPA) or poly(ethylene oxide) (PEO) as separation medium. For both LPA and PEO, it was found that the addition of 25% (v/v) glycerol to the running buffer enhanced the separation of large double-stranded DNA fragments and increased the migration time. The two buffers used, 1 x TBE (Tris-boric acid-EDTA) and 1 x TTE (Tris-N-tris(hydroxymethyl)methyl-3-aminopropanesulfonic acid (TAPS)-EDTA), showed similar improvement, but the effect on the 1 x TBE buffer was more amplified. The difference in buffer properties, such as viscosity, conductance, and pH, had little effect on the separation. We attribute the improvements made in the separation to the ability of glycerol to induce a conformational change in DNA as demonstrated by dynamic light scattering results. The presence of glycerol can increase the electrostatic interactions between the phosphate groups, decrease the hydration sphere of the polynucleotides, and compete with water to form hydrogen bonds with the side group of bases. These interactions increase the DNA contour length and reduce the effective charge over weight ratio, which can explain the experimental data. The complex formed by boric acid and glycerol had a stronger effect on the DNA conformation change than glycerol itself. This enhancement was also observed in DNA sequencing analysis.

Acrylic Resins↗

Separation and quantitative analysis of some carotenoid fatty acid esters of fruits by liquid chromatography.

The adsorption and partition properties of several fatty acid esters of capsanthin, capsorubin, beta-cryptoxanthin, lutein, violaxanthin and beta-citraurin isolated from fruits were studied by normal-phase (silica) and reversed-phase (octadecylsilane) liquid chromatography using Sudan 1 as internal standard. The separation on a normal phase was based on the functional group of the carotenoids and individual esters of the same carotenoid did not resolve. The separation on a reversed phase was more dependent on the number of acyl carbons than the functional group, and individual esters of the same carotenoid differing only two acyl carbons were separated with a resolution of 3. There was a linear relationship between number of acyl carbons and retention times of the same carotenoid on reversed phase. The separation on a normal phase was the reverse of that on a reversed phase, and a combination of normal-phase followed by reversed-phase chromatography was used for the separation of esters with the same or close retention times.

Carotenoids↗

Separation and purification of oligonucleotides using a new bonded-phase packing material.

We describe a new bonded-phase packing material, based upon surface-stabilised microparticulate silica, suitable for the rapid separation and purification of oligonucleotides. Columns packed with this material were demonstrated to give rapid separations of individual oligonucleotide species of up to 44 base units with high purity; agarose gel electrophoresis showed that the products were essentially single bands, with only trace quantities of the (n-1)-mer present. Baseline resolution of the desired oligomer from (n +/- 1)-mer was achieved under preparative loading conditions, where up to 200-300 micrograms of oligonucleotide could be separated. The separation was essentially independent of structure or sequence of the oligonucleotides. The retention mechanism of the oligonucleotides was investigated, and the results used to determine the optimum column configuration and separation conditions.

Base Sequence↗

Studies on the preparative capability of the horizontal flow-through coil planet centrifuge and high-performance liquid chromatography in the separation of polar compounds from Oxytropis ochrocephala Bunge.

Horizontal flow-through coil planet centrifuge (CPC) and high-performance liquid chromatography (HPLC) techniques were used for separation of polar compounds from a crude ethanol extract of Oxytropis ochrocephala Bunge, a poisonous legume plant widely distributed in northwestern China. The performance of these two chromatographic methods was compared in terms of column efficiency, peak resolution, separation time, sample loading capacity, etc. The results indicated that two polar compounds in the crude extract were equally well separated by these two methods. HPLC gave comparable peak resolution in shorter separation time while its sample loading capacity was limited to the mg range. The CPC method required a long separation time, but yielded a higher purity of fractions with a much greater capacity.

Centrifugation↗

Predicting bandwidth in the high-performance liquid chromatographic separation of large biomolecules. II. A general model for the four common high-performance liquid chromatography methods.

A general model for describing gradient elution separations of peptides and proteins by reversed-phase high-performance liquid chromatography (HPLC) has been presented previously. This model has now been modified so that it can be applied to any of the four HPLC methods used for separating biological macromolecules: reversed-phase, ion-exchange, hydrophobic-interaction and size-exclusion chromatography, carried out in either an isocratic or gradient elution mode. The role of sample molecule structure and the particular column used has been further studied, so that previous empirical parameters for different column/sample choices can now be estimated from three physical properties of the sample and the column: sample molecular weight, native vs. denatured sample, column packing pore diameter. This eliminates much of the empiricism of our preceding model, and minimizes the number of experimental runs now required in order to apply the model in practice. The final model has been tested for several hundred runs involving peptides and proteins in the molecular weight range 600-162,000, all four of these HPLC methods, in both isocratic and gradient elution modes, and using data from several different laboratories (including our own). The model is able to predict bandwidth in HPLC separations of proteins and peptides with an accuracy of +/- 17% (1 standard deviation), for the case of "well-behaved" separations. Separations that are not "well-behaved" will give wider bands than predicted by the model.

Chemical Phenomena↗

Separation of major phospholipid classes by high-performance liquid chromatography and subsequent analysis of phospholipid-bound fatty acids using gas chromatography.

A sensitive high-performance liquid chromatographic method for the separation of major phospholipid (PL) classes in biological materials is described. Using this method it was easy to separate P-cholin, P-ethanolamine, P-serine, P-inositol, cardiolipin, sphingomyelin, lyso-P-choline and lyso-P-ethanolamine from skeletal and cardiac muscle samples. The method is based on the simultaneous use of a pH gradient and a polarity gradient. This procedure can easily be modified to optimize the separation of PLs from very different tissues. Subsequent analysis of the PL-bound fatty acids (FAs) by gas chromatography resulted in a well separated FA pattern. Following this FA separation it was possible to recalculate the specific PL content in the original sample.

Animals↗

Hyperlayer separation in hollow fiber flow field-flow fractionation: effect of membrane materials on resolution and selectivity.

Hollow fiber flow FFF (HF FlFFF) has recently shown its capability to separate and characterize the size of submicrometer particles and has demonstrated the potential to be developed into a disposable flow FFF channel. In this work, HF FIFFF was used for the hyperlayer separation of micron-sized particles and the separation capability was examined by using various hollow fiber membrane materials (Polysulfones, cPVC, and PAN). From the experiments, PAN (polyacrylonitriles) showed an outstanding performance in particle separation compared to the other membranes. By orienting the fiber module in an upright direction, the upstream flow migration reduced band broadening of eluted peaks. When the efficiency of the PAN hollow fiber system was tested by varying the ratio of outflow-rate to radial flow-rate, it was found that optimum separation in hyperlayer HF FlFFF can be obtained at the ratio of about 6-7. From the examination of retention at or around steric inversion diameter, it was observed that experiments showed a good agreement with predictions by semi-empirical calculation. In hyperlayer HF FlFFF the diameter based selectivity values were shown to be 1.2-1.7 depending on the type of membranes and the field strength (the radial flow-rate) conditions.

Chemical Fractionation↗

Separation of chiral sulfoxides by liquid chromatography using macrocyclic glycopeptide chiral stationary phases.

A set of 42 chiral compounds containing stereogenic sulfur was prepared. There were 31 chiral sulfoxide compounds, three tosylated sulfilimines and eight sulfinate esters. The separations were done using five different macrocyclic glycopeptide chiral stationary phases (CSPs), namely ristocetin A, teicoplanin, teicoplanin aglycone (TAG), vancomycin and vancomycin aglycone (VAG) and seven eluents, three normal-phase mobile phases, two reversed phases and two polar organic mobile phases. Altogether the macrocyclic glycopeptide CSPs were able to separate the whole set of the 34 sulfoxide enantiomers and tosylated derivatives. Five of the eight sulfinate esters were also separated. The teicoplanin and TAG CSPs were the most effective CSPs able to resolve 35 and 33 of the 42 compounds. The three other CSPs each were able to resolve more than 27 compounds. The normal-phase mode was the most effective followed by the reversed-phase mode with methanol-water mobile phases. Few of these compounds could be separated in the polar organic mode with 100% methanol mobile phases. Acetonitrile was also not a good solvent for the resolution of enantiomers of sulfur-containing compounds, neither in the reversed-phase nor in the polar organic mode. The structure of the chiral molecules was compared to the enantioselectivity factors obtained with the teicoplanin and TAG CSP. It is shown that the polarity, volume and shape of the sulfoxide substituents influence the solute enantioselectivity factor. Changing the oxidation state of the sulfur atom from sulfoxides to sulfinate esters is detrimental to the compound's enantioselectivity. The enantiomeric retention order on the teicoplanin and TAG CSPs was very consistent: the (S)-(+)-sulfoxide enantiomer was always the less retained enantiomer. In contrast, the (R)-(-)-enantiomer was less retained by the ristocetin A, vancomycin and vancomycin aglycone columns, showing the complementarity of these CSPs. The macrocyclic glycopeptide CSPs provided broad selectivity and effective separations of chiral sulfoxides.

Chromatography, Liquid↗

New triazine spectroscopic reagent for the separation of DL-amino acids by micellar electrokinetic chromatography.

An approach to the chiral separation of racemic mixtures of amino acids by means of micellar electrokinetic chromatography after derivatization with a new triazine spectroscopic reagent, 3-(4,6-dichloro-1,3,5-triazinylamino)-7-dimethylamino-2-methylphenazine (DTDP), has been evaluated. It was found that the derivatives of the aliphatic amino acids such as serine, valine and arginine, could produce a strong UV absorption at 282 nm, whose apparent molar absorptivities are of 10(-4) M(-1) cm(-1), and thus the concentration of the amino acids down to 3 x 10(-7) M can still give a detectable signal (S/N = 3). Beta-Cyclodextrin (beta-CD) added to the buffer system was used as a chiral selector, and separation conditions were optimized. The presence of an organic modifier (2-propanol) was also a prerequisite for the chiral separation. The best results for the chiral separation of DTDP-amino acids were achieved in a mixed sodium dodecylsulfate-beta-CD-borate-2-propanol medium at pH 9.0. Compared to some of the commonly used derivatization methods, the present one offers a relatively stable derivative and strong UV absorption for the spectroscopically inert amino acids, thus enabling amino acids to be separated and detected by CE even with a simpler UV detector.

Amino Acids↗

Comparative evaluation of three alpha-hydroxycarboxylic acids for the separation of lanthanides by dynamically modified reversed-phase high-performance liquid chromatography.

The resolution for the three homologues of alpha-hydroxycarboxylic acids viz. lactic acid, alpha-hydroxyisobutyric acid (alpha-HIBA) and alpha-hydroxy-alpha-methylbutyric acid (alpha-H-alpha-MBA), was compared for the individual separation of 14 lanthanide elements under identical experimental conditions. Alpha-HIBA was found to be the best for separation of heavier lanthanides (Tb to Lu) while alpha-H-alpha-MBA led to a better separation for lighter lanthanides (La to Eu). All the 14 lanthanides were separated by gradient HPLC employing both alpha-HIBA and alpha-H-alpha-MBA so that there was reasonable resolution among all the peaks and the separation was completed in a short time.

Carboxylic Acids↗

Capillary electrophoretic separations of proteins using carrier ampholytes.

Capillary separations of proteins using carrier ampholytes are performed between an anolyte and a catholyte of same pH (pH 3). Depending upon the concentration of carrier ampholytes used, two different separation processes take place. At a 10% concentration, the high-resolution separation of six model proteins is achieved, which can be described as a transient capillary isoelectric focusing (cIEF) system moving isotachophoretically. The isotachophoretic (ITP) behaviour of the system is evidenced by the influence of the catholyte concentration on the separation. The separation is neither pure cIEF nor pure cITP and the migration order of the proteins results from the influence of both their isolelectric points and their mobilities.

Electrolytes↗

Preparative separation of isomeric sulfophthalic acids by conventional and pH-zone-refining counter-current chromatography.

Two modes of high-speed counter-current chromatography (HSCCC) were applied to separate 3- and 4-sulfophthalic acid from a mixture. Conventional HSCCC was useful for the separation of up to several hundred milligram quantities of these positional isomers, while pH-zone-refining CCC was implemented successfully to separations at the multigram level. The conventional HSCCC separations were performed with a standard J-type HSCCC system that has a superior resolution but a lower level of retention of the stationary phase of the biphasic solvent system used (acidified n-butanol-water). The pH-zone-refining CCC separations were performed with an X-type HSCCC system (a cross-axis system) that has a higher capability for retention of the stationary phase. The purified positional isomers (over 99% pure as determined by HPLC) were characterized by 1H NMR and negative ion electrospray ionization mass spectrometry.

Chromatography, High Pressure Liquid↗