Improved methods for 1H-3H heteronuclear shift correlation.

A better understanding of the structure of complex 3H-labeled molecules can be obtained by complete assignment of their 1H and 3H solution-state NMR spectra. The assignment process is aided by the detection of heteronuclear chemical shift correlations between 1H and 3H nuclei. Heteronuclear correlation (HETCOR) experiments previously applied to this task exhibit several drawbacks caused by the nature of both the pulse sequences and 1H-3H spin systems. The range of J-couplings involved in 1H-3H coupling networks make it challenging to perform correlation experiments using methods that rely on coherences created during free precession periods and interrupted by transfer pulses. Two alternative HETCOR experiments are demonstrated for 1H-3H systems in the present work and are shown to have advantages over earlier methods. The first experiment is known as hetero-TOCSY and correlates heteronuclear chemical shifts using J-cross polarization. This experiment achieves both homonuclear and heteronuclear mixing and connects the chemical shifts of all 1H and 3H nuclei in a coupling network. A second HETCOR experiment uses the heteronuclear Overhauser effect to obtain through-space correlations between nearby nuclei. The 1H-3H HETCOR experiments are phase sensitive and typically contain more correlations than other methods, which is beneficial for assignment purposes, while being sensitive enough to be applicable to routine analytical samples. The experiments were used to analyze 3H incorporation in sub-milligram quantities of 3H-labeled pharmaceutical derivatives with complex labeling schemes.

Hydrogen↗

Breast tissue differentiation using arterial spin tagging.

An arterial spin tagging (AST) pulse sequence has been developed to measure T(1) and relative blood perfusion. This full sequence is composed of three sequences: selective tagging, nonselective tagging, and nontagging. Perfusion quantification error resulting from imperfect inversion and acquisition slice profiles has been addressed in the literature. In this work, the error is reduced through the application of optimized Shinnar-Le Roux (SLR) RF pulses and a semi-log linear regression data-processing technique. A threshold approach based on the breast tissue T(1) and relative blood perfusion is introduced to show that these two parameters can be applied to breast tissue differentiation and potentially to cancer detection.

Breast↗

MR imaging with hyperpolarized 3He gas.

Magnetic resonance images of the lungs of a guinea pig have been produced using hyperpolarized helium as the source of the MR signal. The resulting images are not yet sufficiently optimized to reveal fine structural detail within the lung, but the spectacular signal from this normally signal-deficient organ system offers great promise for eventual in vivo imaging experiments. Fast 2D and 3D GRASS sequences with very small flip angles were employed to conserve the norenewable longitudinal magnetization. We discuss various unique features associated with performing MRI with hyperpolarized gases, such as the selection of the noble gas species, polarization technique, and constraints on the MR pulse sequence.

Animals↗

Quantitative measurement and imaging of transport processes in plants and porous media by 1H NMR.

NMR and MRI have been applied to transport processes, that is, net flow and diffusion/perfusion, of water in whole plants, cells, and porous materials. By choosing proper time windows and pulse sequences, magnetic resonance imaging can be made selective for each of the two transport processes. For porous media and plant cells the evolution of the spatial distribution of excited spins has been determined by q-space imaging, using a 20 MHz pulsed 1H NMR imager. The results of these experiments are explained by including spin-relaxation and exchange at boundaries. A 10 MHz portable 1H NMR spectrometer is described, particularly suitable to study the response of net flow in plants and canopies to changing external conditions.

Biological Transport, Active↗

Evidence on precise time-coded symbols and memory of patterns in monkey cortical neuronal spike trains.

High-resolution examination of pulse sequences generated by single visual cortex cells of the rhesus monkey in response to precisely controlled visual stimuli has disclosed (i) that the outputs of such neurons contain highly improbable (P less than 10(-7) numbers of identical triplets of precisely repeating pulse patterns; (ii) that the precision of such matches is better than 1/6000th of a second; (iii) that there is a similarly improbable high number of precisely matching pairs of triplets and anti-triplets, about half of which are present in symmetrical quadruplets of the form A-B-A, and that precisely replicating quadruplets and quintuplets are similarly generated in improbably large numbers; (iv) that identical triplets occur highly preferentially during immediately succeeding presentation of the same stimulus to the eye; and (v) that identical triplet (and doublet) patterns occur much more frequently in the responses of the same nerve when the eye receives identical or similar stimuli in different experiments than when dissimilar stimuli are applied. From these findings it is concluded (i) that the high precision of pattern replication required for triplets of pulses in time to serve to encode specific inputs and to permit their decoding through spatial summation is met (observations i-iii); (ii) that stimulus-specific triplets symbolize components of responses to specific stimuli (observation iv); (iii) that a temporary memory store of previous responses exists (observations iv and v); and (iv) that the mammalian brain uses precise patterns of discharges in time to represent and store specific data, rather than statistical qualities associated with pulse trains to symbolize qualitative stimulus components.

Action Potentials↗

MRI lung perfusion 2D dynamic breath-hold technique in patients with severe emphysema.

BACKGROUND: Our aim was to prospectively evaluate a semi-quantitative pulmonary perfusion MR technique using a breath-hold 2D dynamic sequence in patients with severe pulmonary emphysema. MATERIALS AND METHODS: Thirty patients with severe emphysema were studied with pulmonary perfusion MRI. Results were compared with those obtained through lung scintigraphy, considered as the gold standard technique. We used Fast Field Echo (FFE) pulse sequences in the coronal and sagittal planes, with paramagnetic contrast agent administration. Ten healthy volunteers were studied as the control group. Three thoracic radiologists independently reviewed all the subjects, evaluating the site and entity of perfusional defects. Peak intensity and apparent mean transit time were calculated. RESULTS: MRI showed high sensitivity (86.7%) and good specifity (80.0%) in detecting perfusional defects. We observed lower peak signal intensities in emphysematous regions. CONCLUSION: Lung perfusion MR is a potential alternative to Nuclear Medicine in the evaluation of severe pulmonary emphysema.

Adult↗

Compressive myelopathy in fluorosis: MRI.

We examined four patients with fluorosis, presenting with compressive myelopathy, by MRI, using spin-echo and fast low-angle shot sequences. Cord compression due to ossification of the posterior longitudinal ligament (PLL) and ligamentum flavum (LF) was demonstrated in one and ossification of only the LF in one. Marrow signal was observed in the PLL and LF in all the patients on all pulse sequences. In patients with compressive myelopathy secondary to ossification of PLL and/or LF, fluorosis should be considered as a possible cause, especially in endemic regions.

Adult↗

An NMR study of the structural basis of the wide range of pharmacological functions of acetylsalicylic acid.

The interaction between acetylsalicylic acid (aspirin) and membrane was studied by NMR spectra. (1) NMR spectra showed acetylsalicylic acid did not insert into membrane; (2) 1H NMR spectrum recorded by spin-echo pulse sequence showed protons of the aromatic ring interacted with membrane; (3) the change of spin-lattice relaxation (T1) of 31P was ascribed to the association of acetylsalicylic acid to the polar head of lecithin; (4) the self-diffusion coefficient measured by pulsed field gradients NMR showed the mobility of acetylsalicylic acid was restricted by membrane and that acetylsalicylic acid changed membrane viscosity. Based on the results, the relationship between the interaction and the mechanism of the wide pharmacological functions of acetylsalicylic acid is discussed.

Aspirin↗

Sequence-specific assignments of the 1H nuclear magnetic resonance spectra of reduced high-potential ferredoxin (HiPIP) from Chromatium vinosum.

The 1H resonances of the high-potential [4Fe-4S]2+ ferredoxin from Chromatium vinosum have been assigned through conventional sequential methodology applied to 2D NMR spectra. Almost 80% of the residues were identified using standard 2D COSY, HOHAHA, and NOESY pulse sequences. These residues correspond to four segments of the primary structure that do not interact strongly with the iron-sulfur cluster. A minor correction to the amino acid sequence is strongly suggested by these NMR data. Additional protons more sensitive to the proximity of the cluster were assigned by a combination of NOESY experiments with fast repetition rates and short mixing times and of HOHAHA spectra recorded with reduced spin-lock duration aimed at compensating for the short relaxation rates. Hence, the contributions of 79 residues out of 85 were identified in NMR spectra, among which the assignments of 64 residues were completed. Even the fastest relaxing protons, like those of the cysteine ligands, could be correlated, partly because the strong hyperfine shifts isolate them from the crowded diamagnetic region. However, other protons, in particular those involved in NH-S hydrogen bonds with the iron-sulfur cluster, were more difficult to identify, most probably because their relatively broad signals overlapped with those of protons not or less perturbed by the active site. The availability of the major part of the 1H NMR assignments has enabled the detection and identification of many interresidue NOESY cross peaks. These data are in full agreement with the elements of secondary structure previously revealed by X-ray crystallographic analysis of the protein.(ABSTRACT TRUNCATED AT 250 WORDS)

Amino Acid Sequence↗

Enhanced sensitivity of rapidly exchanging amide protons by improved phase cycling and the constructive use of radiation damping.

Two alternative, general methods are presented that lead to enhanced signal intensity of rapidly exchanging protons. Both methods work by avoiding saturation of the water resonance, and are convenient to implement since they do not use any selective pulses. One method carefully chooses proton pulse phases and gradient strength and position in such a way that the water is realigned along the +z axis at the beginning of the acquisition time. An alternative method is proposed for cases where the pulse sequence does not allow such phase cycling. The latter uses radiation damping to bring water back to the +z axis 20-30 ms after acquisition. The methods are applied to the triple-resonance experiments HNCA, HNCO and HN(CO)CA. Both methods require pulsed B0 field gradients and can result in higher signal intensity by a factor of two or more.

Magnetic Resonance Spectroscopy↗

Proton magnetic resonance microimaging of human trabecular bone.

Proton magnetic resonance (1H magnetic resonance imaging (MRI)) images of human trabecular bone were acquired and discussed for two samples with different porosity. Three-dimensional 3D Spin Echo (3D SE) and Multi-Slice Multi-Echo (MSME) pulse sequences were examined. A very high slice resolution of (38 microm)2 was achieved (MSME). The intensity histograms were found useful for the characterization of the bone porosity. A spatial distribution of the spin-spin relaxation time T2 was monitored with the MSME pulse program. The work demonstrates the great potential of the proton MRI technique in the study of the trabecular bone morphology.

Bone and Bones↗

Time-resolved MR imaging by automatic data segmentation.

A method for time-resolved imaging that provides a flexible trade-off between imaging time and temporal resolution is presented. It is based on a view order selection technique that automatically segments the acquired raw data into appropriate temporal frames. When used with cardiac monitoring and phase-contrast imaging, data similar to that obtained with a conventional gated phase-contrast sequence are acquired rapidly. For many applications, the temporal resolution can be reduced enough to permit imaging within a breath-hold interval, while still allowing accurate time-averaged flow quantitation. This is a general technique that can be implemented within a variety of pulse sequences and can resolve other motion cycles, including the respiratory cycle.

Algorithms↗

Magnetic resonance imaging of peripheral soft tissue hemangiomas.

Ten patients with soft tissue hemangiomas outside the central nervous system were studied with MR imaging. Eight patients were studied at 1.5 Tesla (T) with T1-weighted and triple echo T2-weighted sequences. Two additional patients were imaged on a 0.5-T system. The MR images were correlated with images from other modalities. Histologic diagnosis was obtained in all cases. It was found that prolonged T2-weighted imaging together with standard spin echo T1 and T2 pulse sequences is a good substitute for contrast-enhanced CT and arteriographic evaluation of soft tissue hemangiomas.

Adolescent↗

Adiabatic squeezing of molecular wave packets by laser pulses.

Strong pulse sequences can be used to control the position and width of the molecular wave packet. In this paper we propose a new scheme to maximally compress the wave packet in a quasistatic way by freezing it at a peculiar adiabatic potential shaped by two laser pulses. The dynamic principles of the scheme and the characteristic effect of the different control parameters are presented and analyzed. We use two different molecular models, electronic potentials modeled by harmonic oscillators, with the same force constants, and the Na(2) dimer, to show the typical yield that can be obtained in compressing the initial (minimum width) molecular wave function.

Journal Article↗

[Superparamagnetic iron particles. The clinical results in the MR diagnosis of liver metastases].

The diagnostic value of superparamagnetic iron particles as a tissue-specific MR contrast medium of the reticulo-endothelial system was studied in 30 patients. All patients had liver metastases (maximally 5 known metastases on MR). The patients were examined on a 1.5 Tesla scanner before and after a slow intravenous injection of iron particles (AMI-25) at a dose of 15 mumol/kg. Contrast injection led to a significant reduction of signal strength in the liver parenchyma (p < or = 0.001) but not in the metastases. Contrast enhanced spin echo sequences (SE 2300/45) provided the most marked liver/tumour contrast, greater than the contrast values of T1- and T2-weighted images (p < or = 0.01). After the intravenous injection of iron particles, small metastases in particular are more easily demonstrated. A new, rapid T2-weighted pulse sequence (PSIF 10/15/15 degrees) results in the elimination of vascular signals and leads to better differentiation between lesions and intrahepatic vessels. The use of superparamagnetic iron particles as an MR contrast medium improves the demonstration of liver metastases.

Contrast Media↗

Compensation for spin-lock artifacts using an off-resonance rotary echo in T1rhooff-weighted imaging.

The origin of image artifacts in an off-resonance spin-locking experiment is shown to be imperfections in the excitation flip angle. A pulse sequence for off-resonance spin locking is implemented that compensates for imperfections in the excitation flip angle through an off-resonance rotary echo. The off-resonance rotary echo alternates the frequency offset and phase of the RF transmitter during two spin-locking pulses of equal duration. The underlying theory is detailed, and MR images demonstrate the effectiveness of the technique in agarose gel phantoms and in in vivo human brain at 3T.

Algorithms↗

Inter-sequence and inter-imaging unit variability of diffusion tensor MR imaging histogram-derived metrics of the brain in healthy volunteers.

BACKGROUND AND PURPOSE: Diffusion tensor MR imaging has the potential to improve our ability to monitor several neurologic conditions. As a preliminary step to the assessment of the role of diffusion tensor MR imaging in the context of longitudinal and multicenter studies, we evaluated the effect of sequence-, imaging unit-, and imaging-reimaging-induced variations on diffusion tensor MR imaging quantities derived from histogram analysis of a large portion of the central brain of healthy volunteers. METHODS: Each of eight healthy volunteers underwent imaging on two MR imaging units using three different pulsed gradient spin-echo single shot echo-planar pulse sequences (each of them having a different diffusion gradient scheme). Four additional healthy participants underwent imaging twice on the same imaging unit to assess imaging-reimaging variability. RESULTS: For mean diffusivity histograms, the differences between inter-sequence and inter-imaging unit coefficients of variation were significant for all the considered quantities with P values ranging from.003 to <.001. Also, the inter-imaging unit coefficient of variation for average fractional anisotropy was significantly higher than the corresponding inter-sequence coefficient of variation (P =.002). In general, inter-sequence mean diffusivity histogram-derived metrics (coefficients of variation ranging from 1.72% to 5.56%) were more reproducible than were fractional anisotropy histogram-derived metrics (coefficients of variation ranging from 5.45% to 7.34%). Imaging-reimaging variability was found to fall in the range of inter-sequence coefficients of variation for all the considered quantities. CONCLUSION: This study shows that inter-sequence, imaging-reimaging, and inter-imaging unit variabilities of diffusion tensor MR imaging-derived measurements are relatively low, suggesting that diffusion tensor MR imaging might provide additional measures of outcome with which to assess the evolution of brain structural damage in large scale studies of various neurologic conditions.

Analysis of Variance↗

Continuous arterial spin labeling using a train of adiabatic inversion pulses.

PURPOSE: To develop a simple and robust magnetic resonance imaging (MRI) pulse sequence for the quantitative measurement of blood flow in the brain and cerebral tumors that has practical implementation advantages over currently used continuous arterial spin labeling (CASL) schemes. MATERIALS AND METHODS: Presented here is a single-coil protocol that uses a train of hyperbolic secant inversion pulses to produce continuous arterial spin inversion for perfusion weighting of fast spin echo images. Flow maps of normal rat brains and those containing a 9L gliosarcoma orthotopic tumor model conditions were acquired with and without carbogen. RESULTS: The perfusion-weighted images have reduced magnetization transfer signal degradation as compared to the traditional single-coil CASL while avoiding the use of a more complex two-coil CASL technique. Blood flow measurements in tumor and normal brain tissue were consistent with those previously reported by other CASL techniques. Contralateral and normal brain showed increased blood flow with carbogen breathing, while tumor tissue lacked the same CO(2) reactivity. CONCLUSION: This variation of the CASL technique is a quantitative, robust, and practical single-coil method for measuring blood flow. This CASL method does not require specialized radiofrequency coils or amplifiers that are not routinely used for anatomic imaging of the brain, therefore allowing these flow measurements to be easily incorporated into traditional rodent neuroimaging protocols.

Anesthetics, Inhalation↗