Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Poly T”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83Linked to original sources

Synthesis, characterization, and cytocompatibility of elastomeric, biodegradable poly(ester-urethane)ureas based on poly(caprolactone) and putrescine.

The engineering of tissue for mechanically demanding applications in the cardiovascular system is likely to require mechanical conditioning of cell-scaffold constructs prior to their implantation. Scaffold properties amenable to such an application include high elasticity and strength coupled with controllable biodegradative and cell-adhesive properties. To fulfill such design criteria, we have synthesized a family of poly(ester-urethane)ureas (PEUUs) from polycaprolactone and 1,4-diisocyanatobutane. Lysine ethyl ester (Lys) or putrescine was used as chain extenders. To encourage cell adhesion, PEUUs were surface modified with radio-frequency glow discharge followed by coupling of Arg-Gly-Asp-Ser (RGDS). The synthesized PEUUs were highly flexible, with breaking strains of 660-895% and tensile strengths from 9.2-29 MPa. Incubation in aqueous buffer for 8 weeks resulted in mass loss, from >50% (Lys chain extender) to 10% (putrescine chain extender). Human endothelial cells cultured for 4 days with medium containing the degradation products from PEUUs with either the Lys or putrescine chain extender showed no toxic effects. Cell adhesion was 85% of that measured on tissue-culture polystyrene for unmodified PEUU surfaces (p < 0.01) and >160% (p < 0.001) of polystyrene on RGDS-modified PEUUs. These biodegradable PEUUs demonstrate potential for future application as cell scaffolds in cardiovascular tissue-engineering or other soft-tissue applications.

Absorbable Implants↗

Sustained drug delivery systems. I. The permeability of poly(epsilon-caprolactone), poly(DL-lactic acid), and their copolymers.

The maximum steady state flux, diffusion coefficients, and solubilities of five contraceptive steroids in homopolymers and copolymers of epsilon-caprolactone and DL-lactic acid were determined. The permeabilities of polymers of epsilon-caprolactone were comparable to silicone rubber and, by inference, are suitable for the construction of drug delivery devices. Poly(DL-lactic acid) was 10(4) times less permeable, although its permeability was significantly enhanced by additives.

Delayed-Action Preparations↗

Poly(ethylene glycol) enhances cell motility on protein-based poly(ethylene glycol)-polycarbonate substrates: a mechanism for cell-guided ligand remodeling.

The regulation of cell motility on ligand-adsorbed poly(ethylene glycol) (PEG)-based polymeric biomaterials is governed by variables that are not well characterized. In this report, we examined keratinocyte migratory responsiveness to PEG-variant tyrosine-derived polycarbonates adsorbed with equivalent levels of the cell adhesion ligand, fibronectin. The equivalently adsorbed ligand adopted differential distributions, confirmed via atomic force microscopy, and the total number of exposed cell-binding domains (CBD), quantified through immunosorbent fluorometry, varied as a function of PEG concentration. Specifically, the CBD exposure was maximized at 4 mol % PEG and diminished at 8 mol % PEG, suggesting, based on our previous work (Tziampazis et al., Biomaterials 2000;21:511-520), that activation of cell adhesion and motility could be potentially promoted through increased CBD exposure at intermediate levels of PEG. This was confirmed through cell migration studies wherein cell speed values increased from 11 to 22 microm/h as the PEG concentration was increased from 0 to 4 mol %. Unexpectedly, however, high cell motility rates were sustained at 8 mol % PEG despite diminished levels of initial CBD exposure beyond 4 mol % PEG, suggesting that factors other than the initial CBD exposure may additionally have a role in activating cell migration at higher levels of PEG. Through studies of direct ligand mobility, cell-ligand-polymer interactions via atomic force microscopy, and CBD variation and integrin receptor roles in ligand remodeling, we offer evidence that cell motility is enhanced by a new mechanism for the regimen of higher PEG concentration: upon cell attachment and spreading, the ligand exhibits greater "slippage" at the polymer interface, and undergoes cell-engendered remodeling, which further activates cell motility, likely through enhanced exposure of hitherto encrypted sites for cell binding and signaling.

Antibodies↗

Water vapor absorption into amorphous sucrose-poly(vinyl pyrrolidone) and trehalose-poly(vinyl pyrrolidone) mixtures.

Previous studies from this laboratory suggested that a solution model (Flory-Huggins equation) modified by a free volume model (Vrentas equation) could satisfactorily describe water absorption into an amorphous solid composed of a sugar or a polymer. This paper has extended the studies of single solutes to binary mixtures of trehalose-and sucrose-poly(vinyl pyrrolidone) (trehalose-PVP and sucrose-PVP, respectively) either co-lyophilized or individually lyophilized and then physically mixed. Water vapor absorption isotherms of the binary mixtures were determined at 30 degrees C. Co-lyophilized PVP-sugar mixtures take up essentially the same amount of water as predicted by the weight average of individual isotherms, whereas sugar crystallization is significant retarded in the molecular dispersions. The sugar-PVP interaction, as reflected in the Flory-Huggins chi interaction parameter, was estimated by fitting the high relative pressure (p/p(0)) region of the isotherm, at which the system is in a liquid state, with a three-component Flory-Huggins-type model. The estimated sugar-water PVP-water, and sugar-PVP interaction parameters suggest that the solute-water interactions are not significantly affected by the sugar-PVP interaction; that is, the solute-water interaction parameters in a binary solute system are similar to those in the corresponding single solute systems. Based on these interaction parameters, the sucrose-PVP interaction appears to be stronger than that of trehalose-PVP. Manipulation of the interaction parameters suggest that the water vapor absorption isotherm is not a sensitive indicator of possible sugar-PVP interactions. Density, glass transition temperature, T(g), and the heat capacity change, DeltaC(p), at T(g) were determined to estimate the excess water absorption energy due to the plasticizing effect of water using the structural relaxation model, as described by Vrentas. Results suggest that PVP is a better antiplasticizer for sucrose than for trehalose. Consequently, the excess free energy arising from structural relaxation was disproportionally reduced by the presence of PVP in these molecular dispersions. Finally, the entire isotherms of co-lyophilized sugar-PVP mixtures are reasonably described with an extended three-component Flory-Huggins model and Vrentas glass structural relaxation model.

Absorption↗

Poly(epsilon-caprolactone)/chitin and poly(epsilon-caprolactone)/chitosan blend films with compositional gradients: fabrication and their biodegradability.

Poly(epsilon-caprolactone) (PCL)/chitin and PCL/chitosan blend films with compositional gradients were successfully fabricated by a dissolution/diffusion method; that is, repeatedly pouring the PCL/chitin (or PCL/chitosan) blend solutions, with variable composition, onto polysaccharide layers. The compositional gradient structure in the resulting films was characterized by polarized optic microscopy, ATR-FT-IR and trans-FT-IR microscopic spectroscopy. Enzymatic degradability of the PCL/chitin and PCL/chitosan blend films with compositional gradients in the presence of lysozyme was compared with those of homogeneous films and two-layer films. It was found that the degradation rate of PCL/chitin blend films with a compositional gradient was far lower than that of the neat chitin film, whereas the degradation rate of PCL/chitosan blend films with a compositional gradient was close to that of the neat chitosan film. The suppression of the chitosan crystallization, which accelerates the enzymatic degradation, at the surface of PCL/chitosan films with a compositional gradient was much more severe than that for PCL/chitin films with a compositional gradient.

Biodegradation, Environmental↗

Characterization of Silylated Silicas by Inverse Gas Chromatography: Modelization of the Poly(dimethylsiloxane) Monomer Unit/Surface Interactions Using Poly(dimethylsiloxane) Oligomers as Probes

Inverse gas chromatography (IGC) at infinite dilution was used to characterize the fumed silica surface. The silica was modified by chemical treatment with either dimethyldichlorosilane or trimethylchlorosilane. To observe the silica and poly(dimethylsiloxane) (PDMS) interactions, we used apolar (alkanes) and polar probes (chloroform, benzene, tetrahydrofuran, etc.), but also model molecules of PDMS such as linear and cyclic oligomers of PDMS with two to five monomer units. It is shown that PDMS oligomers are very appropriate to discriminate the silylated silicas.

Journal Article↗

The Effect of Poly(methyl vinyl ether-alt-maleic acid) Stabilizer on the Stability of Polyaniline-Poly(methyl vinyl ether-alt-maleic acid) Dispersions.

The polyaniline (PANI) dispersions have been prepared in acidic aqueous media by oxidative dispersion polymerization in the presence of a polymeric stabilizer. The polymeric stabilizer used in this study is the poly(methyl vinyl ether-alt-maleic acid) (PMVEMA) which contains acid groups (-COOH). The PANI-PMVEMA particles have a uniform size and a spherical shape. The PANI-PMVEMA dispersions show almost no desorption of the PMVEMA, even though the sonication at 500 W for 20 min and the centrifugation at 500 rpm for 60 min are performed 10 times. The existence of the PMVEMA on the surface is confirmed by X-ray photoelectron spectroscopy. The dispersion stability of the PANI-PMVEMA dispersions is extensively influenced by zeta potential which was governed by the acid group (-COOH) of the PMVEMA on the PANI-PMVEMA particle surface. Copyright 2000 Academic Press.

Journal Article↗

Effect of inactivation of poly(hydroxyalkanoates) depolymerase gene on the properties of poly(hydroxyalkanoates) in Pseudomonas resinovorans.

The phaZ gene of Pseudomonas resinovorans codes for a poly(hydroxyalkanoates) (PHA) depolymerase. Two phaZ mutants of Pseudomonas resinovorans NRRL B-2649, FOAC001 and FOAC002, were constructed by an in vitro transposition procedure followed by chromosomal integration via homologous recombination. A detailed mapping of the transposon insertion sites and an analysis of the resultant sequences showed that putative fusion polypeptides PhaZ(FOAC001) (239 amino-acid residues) and PhaZ(FOAC002) (85 amino-acid residues) could result from the mutant phaZ genes of FOAC001 and FOAC002, respectively. In vivo PHA degradation data indicated that PhaZ(FOAC001) might still retain a partial PHA depolymerization activity, while PhaZ(FOAC002) is completely devoid of this function. The cell yields and PHA contents of B-2649, FOAC001, and FOAC002 were similar when the cells were grown either under a limiting nitrogen-source (low-N) condition for up to 5 days or in excess N-source (high-N) for 3 days. A dramatic decrease in PHA content was observed in the PhaZ-active B-2649 and FOAC001 cells during prolonged cell growth (5 days) in high-N medium or in response to a shift-up in nitrogen-source. The repeat-unit compositions of the PHAs from FOAC001 and FOAC002 contained slightly lower amounts of beta-hydroxyoctanoate and higher beta-hydroxytetradecenoate than that of the wild-type B-2649 when grown under a high-N condition. While the molecular masses of the PHAs from FOAC001 and FOAC002 did not vary under any conditions used in this study, those of the wild-type B-2649 were markedly increased in cells either grown for 5 days under a high-N condition or subjected to a nitrogen-source shift-up. These phaZ mutants thus provide a valuable system to study the influence of PHA depolymerase on the accumulation and properties of medium-chain-length PHA.

Carboxylic Ester Hydrolases↗

Production of poly(L-lactide)-degrading enzyme by Amycolatopsis orientalis for biological recycling of poly(L-lactide).

Efficient production of poly(L-lactide)(PLA)-degrading enzyme was achieved by addition of 0.1% (w/v) silk fibroin powder into a liquid culture medium of an actinomycete, Amycolatopsis orientalis, without other complex nitrogen sources, such as yeast extract and peptone. Scaled-up production of the enzyme in a 5-l jar fermenter showed the possibility of producing this enzyme on an industrial scale at low production cost. The extracellular PLA-degrading enzyme showed potent degrading activity, which is effective for biological recycling of PLA, i.e., 2,000 mg/l of PLA powder was completely degraded within 8 h at 40 degrees C using 20 mg/l purified enzyme. An optically active L-lactic acid with 600 mg/l was obtained as degradation product of PLA without undesirable racemization.

Actinomycetales↗

An unusual suppression of immune response: pretreatment with Poly(Glu60,Phe40) suppresses response to poly(Glu60,Phe40).

The synthetic random copolymer poly( Glu60 , Phe40 ) ( GPhe ) is an excellent immunogen in SWR/J (H-2q) mice. The intravenous injection of soluble GPhe by itself led to antibody production and GPhe -specific T-lymphocyte proliferation. The proliferating lymphocyte was sensitive to anti-Thy 1.2 and anti-Ly 1 antisera. A subsequent immunization with GPhe should therefore lead to an enhanced response. Yet, a single intravenous injection of an aqueous solution of GPhe suppressed the immune response to a subsequent immunization with GPhe in CFA as measured by GPhe -specific plaque-forming colonies, ELISA, T-cell proliferation, and delayed-type hyper-sensitivity. The suppression was not transferable from pretreated mice into normal or irradiated syngeneic recipients with either sera or lymphoid cells. The antibody generated from the pretreatment could not be responsible for the suppression as injection of SWR anti- GPhe antibody into SWR/J mice enhanced, rather than suppressed, the response to the subsequent immunization with GPhe . Pretreatment of mice with a rabbit anti-idiotypic antiserum produced against (SWR anti- GPhe antisera) had no effect on the immune response to GPhe . Thus, the suppression cannot be explained by a simple B-cell tolerance mechanism. This type of unusual suppression was observed only with mice of H-2q haplotype and not with mice of H-2 haplotypes a and k which are also responders to GPhe .

Animals↗

Heparin adsorbing capacities at physiological pH of three poly(amido-amine) resins, and of poly(amido-amine)-surface-grafted glass microspheres.

Three poly(amido-amine)s of similar structure in the form of highly hydrophilic crosslinked resins, have been prepared, and tested for their heparin-adsorbing capacity at physiological pH. They showed different capacities, and their capacities were related to their basicities. One of the same polymers was grafted on the surface of glass microspheres. After treatment, it was shown that the microspheres could adsorb significant amounts of heparin. In all cases most of the adsorbed heparin was hardly eluted with saline, plasma, or blood, but could be recovered by eluting with 0.1 M NaOH. The resins were found to have some haemolytic properties, but no haemolysis was observed with the grafted microspheres.

Adsorption↗

Heparin-like anticoagulant activity of sulphonated poly(ethylene oxide) and sulphonated poly(ethylene oxide)-grafted polyurethane.

Sulphonated poly(ethylene oxide) (PEO-SO3) and PEO-SO3-grafted polyurethane (PU-PEO-SO3) were prepared by bulk modification and their anticoagulant and heparin-like activities were investigated. Anticoagulant activity measured by activated partial thromboplastin time of PU-PEO-SO3 displayed 2%, whereas that of PEO-SO3 itself reached 14% as compared to free heparin. In addition, the anticoagulant effects of these sulphonated polymers were not due to factor Xa inhibition but mainly thrombin inhibition. From the clotting time measurements using reptilase instead of thrombin and antithrombin III (AT III), PEO-SO3 and PU-PEO-SO3 indicated heparin-like activity which represents both prolonged thrombin time (TT) and normal reptilase time and increased TT in the presence of AT III. Thrombin was also neutralized by sulphonated polymers to a great extent. Therefore, the anticoagulant and heparin-like activities of PEO-SO3 and PU-PEO-SO3 seem to contribute to their improved blood compatibility.

Anticoagulants↗

Yeast cell debris and protein partitioning in the poly(ethylene glycol)-poly(vinyl alcohol) biphasic system.

Yeast cells, cell debris and protein partitioning have been investigated in the poly(ethylene glycol) (PEG) 8000/poly(vinyl alcohol) (PVA) 10,000 system. Cells and cell debris partition into the lower (PVA) phase over the pH range 4.8-7.5, and with up to 0.37 M KCl at pH 5.9. Protein partitioning is more pH-dependent in the PEG/PVA system than in the PEG/dextran system, and a significant fraction of the total protein is found at the interface at lower pH values. Significant, rapid purification of overproduced pyruvate kinase in a PEG/PVA system containing Blue Sepharose CL-6B particles is demonstrated.

Cell Fractionation↗

Protein partitioning equilibrium between the aqueous poly(ethylene glycol) and salt phases and the solid protein phase in poly(ethylene glycol)-salt two-phase systems.

True partitioning behaviour, which is independent of the protein concentration in aqueous two-phase systems, only occurs at relatively low protein concentration. The actual concentration limit depends on the properties of the protein. When the concentration of a protein exceeds relatively low values, precipitation at the interface can be observed. This protein precipitate is in equilibrium with the protein solubilized in each of the phases. This paper discusses the effect of protein solubility in view of the equilibrium of the protein concentration between the aqueous poly(ethylene glycol) and salt phases and the solid protein phase using three proteins. It was found that only rarely will the proteins be completely in solution as the concentration is increased until a solubility limit is reached and then the protein precipitates fully out of solution. A behaviour that came close to this was only seen in one case out of six. In virtually all cases, a third phase is formed which represents a solid aggregate phase which is in equilibrium with the other two, largely aqueous, phases. As the overall concentration of protein in the system is increased and the concentration in the top and bottom aqueous phases increases, the pseudo concentration in the solid-phase, C's, also increases. This could have interesting implications in terms of the amount of water associated with this phase and it certainly means that in this particular case, the solid phase is not a crystal.

Aspergillus niger↗

Graft laceration and pullout strength of soft-tissue anterior cruciate ligament reconstruction: in vitro study comparing titanium, poly-d,l-lactide, and poly-d,l-lactide-tricalcium phosphate screws.

PURPOSE: The aim of part 1 of this study was to compare the structural properties of tibia-graft-interference screw constructs of soft-tissue graft fixation via the anterior cruciate ligament (ACL) by use of different interference screws. In part 2 the influence of graft laceration as a result of 1 single interference screw insertion on the mechanical properties of the graft was evaluated. METHODS: In part 1 of the study, in a bovine knee model, soft-tissue graft fixation with titanium, biodegradable poly-D,L-lactide (PLDLA), and PLDLA-tricalcium phosphate (TCP) interference screws was performed, and the structural properties were determined by use of a materials testing machine at a rate of 12.5 mm/s. In part 2 the bone was cut after 1 single insertion of titanium, PLDLA, or PLDLA-TCP interference screws, and the mechanical properties of the graft were determined. RESULTS: Soft-tissue graft fixation with a biodegradable PLDLA interference screw showed a statistically significantly higher maximum load when compared with PLDLA-TCP and titanium interference screws. PLDLA-TCP screw fixation revealed a significantly higher ultimate load than titanium screw fixation. The mechanical properties of the grafts after 1 single insertion of PLDLA-TCP interference screws showed a statistically significantly higher stiffness, yield load, and maximum load when compared with the PLDLA and titanium interference screw groups. CONCLUSIONS: The results of this study suggest that the use of a titanium screw to fix a soft-tissue graft in cruciate ligament reconstruction surgery may cause damage to the graft. Soft-tissue ACL reconstruction fixed with a PLDLA interference screw resulted in a significantly higher pullout strength than ACL reconstructions fixed with a PLDLA-TCP or titanium interference screw. CLINICAL RELEVANCE: In contrast to fixation with a biodegradable interference screw, fixation with a titanium interference screw may damage the integrity of a soft-tissue graft in cruciate ligament reconstruction and should therefore be avoided.

Absorbable Implants↗

Bone-like apatite-forming ability and mechanical properties of poly(epsilon-caprolactone)/silica hybrid as a function of poly(epsilon-caprolactone) content.

Effect of poly(epsilon-caprolactone) (PCL) content on the bioactivity and mechanical properties of PCL/silica hybrid was investigated. The PCL/silica hybrids with different PCL contents were prepared through co-condensation reaction with triethoxysilane end capped PCL and tetraethyl orthosilicate. The higher the PCL content in the hybrid, the lower the apatite-forming rate and showed polymer-like ductile-tough fracture behavior. On the contrary, the lower the PCL content in the hybrid, the higher the apatite-forming rate and showed ceramic-like hard-brittle fracture behavior. At the intermediate PCL content, the apatite-forming rate and its mechanical properties showed also intermediate behaviors. The highest tensile strength and Young's modulus could be obtained at intermediate PCL content and they were around 20 and 600 MPa, respectively, while the strain at failure was around 50%. This new kind of hybrid material is likely to have the potential to be used as a bone repairing material because of its apatite-forming ability and the mechanical properties comparable to human cancellous bone.

Apatites↗

Preferential interactions in pigmented, polymer blends - C.I. Pigment Blue 15:4 and C.I. Pigment Red 122 - as used in a poly(carbonate)-poly(butylene terephthalate) polymer blend.

Some important characteristics of selected pigments have been evaluated, using the inverse gas chromatography (IGC) technique, that indicate the occurrence of preferential interactions in pigmented polymer blends. Attention has been given to copper phthalocyanine pigments and to quinacridone pigments incorporated in polycarbonate-poly(butylene terephthalate) blends. Selected supporting techniques were used to provide supplementary information concerning the pigments of interest, C.I. Pigment Blue 15:4 and C.I. Pigment Red 122. For C.I. Pigment Red 122 and for C.I. Pigment Blue, the dispersive component of the surface free energy decreases as the temperature increases, indicating the relative ease with which the molecules can be removed from the surface.

Azo Compounds↗

Effect of poly(ethylene oxide) on the release behaviors of poly(epsilon-caprolactone) microcapsules containing erythromycin.

The biodegradable poly(epsilon-caprolactone) (PCL)/poly(ethylene oxide) (PEO) microcapsules and the analyzing of form and features for the manufacturing conditions were investigated in a prospective drug delivery systems (DDS) through drug release. The effects of emulsifier, emulsifier concentration, and stirring rate on the diameter and form of the microcapsules were examined using image analyzer (IA) and scanning electron microscope (SEM). The role of interfacial adhesion between PCL/PEO and drug was determined by contact angle measurements, and the drug release rate of the microcapsules was characterized by UV-vis spectroscopy. As a result, the microcapsules were made in spherical forms with a mean particle size of 170 nm approximately 68 microm. And the work of adhesion between water and PCL/PEO was increased with increasing the PEO content, which is due to higher hydrophilicity of PEO. The drug release rate of the microcapsules was significantly increased as the PEO content increased, which could be attributed to the increasing of the hydrophilic groups or the degree of adhesion at the interfaces.

Adhesiveness↗