[Femoral nerve palsy due to excessive granuloma in aseptic cup loosening in cementless total hip arthroplasty].

AIM: Femoral nerve palsy after total hip arthroplasty can result from several causes. Delayed neuropathies of the femoral nerve because of excessive granuloma in loosened implants are a rare condition. CASE REPORT: We report the case of delayed neuropathy of the femoral nerve after cementless total hip arthroplasty because of aseptic loosening of the cup. Electrophysiologic evaluation revealed a severe lesion of the femoral nerve with sensomotoric deficits. An abdominopelvic computed tomography (CT) scan revealed an excessive granuloma with a large intrapelvic portion. After revision of the loosened acetabular component and the femoral nerve and removal of the granuloma the neurologic symptoms improved. CONCLUSION: Regular (1-2 years) clinical and radiological follow-ups are requested after total hip arthroplasty to prevent excessive loosening of implants, excessive granuloma and severe sequelae like nerve damage.

Arthroplasty, Replacement, Hip↗

[Risk factors associated with heterotopic ossifications in primary total hip arthroplasty].

AIM: The purpose of this study was to determine the important predisposing factors associated with heterotopic ossifications (HO) after total hip arthroplasty. METHOD: 589 patients were examined 6 months after primary total hip arthroplasty with regard to periarticular ossifications. Several predetermining factors were evaluated using the hospitalization records and preoperative X-ray examination. RESULTS: A significantly increased frequency of heterotopic ossifications was found for male gender, patients with very high body mass index (BMI), low preoperative range of motion (ROM), long duration of operation and large preexistent osteophytes (p < 0.05). Only one out of the one hundred patients with an BMI < 22.6 developed severe HO (Brooker III). Out of the one hundred patients with the best preoperative ROM (> or = 140 degrees ) only one case developed severe ossifications (Brooker III). There was no correlation with the use of acrylic bone cement or the patient's age. The frequency of HO was significantly reduced both as well by nonsteroidal antiinflammatory drugs as from postoperative radiation prophylaxis. CONCLUSION: In patients undergoing total hip arthroplasty with low preoperative ROM in the hip joint, large osteophytes and a very high BMI an efficient prophylaxis against HO is of great importance.

Arthroplasty, Replacement, Hip↗

[Clinical outcome following robotic assisted versus conventional total hip arthroplasty: a controlled and prospective study of seventy-one patients].

AIM: Robotic assisted total hip arthroplasty remains controversial, since wider exposure of the proximal femur and placement of the leg in maximal hip adduction and external rotation using a rigid leg-holder apparatus may impair significantly the hip abductors. Consequently, it is the purpose of this study to analyse and report both clinical outcome and hip abductor function following robotic assisted versus conventional total hip arthroplasty. MATERIAL AND METHODS: 36 robotic-assisted (CASPAR, Orto-Maquet, Rastatt, Germany) and 35 conventional cementless total hip arthroplasties were followed on average for 18 months regarding incidence of complications, Harris hip score, the scoring system according to Merle d'Aubigné and Postel, hip abductor function (using a spring-balance), and incidence of Trendelenburg's sign (according to the Kuhfuss-classification). Statistical analysis was performed in case of continuous data using the t test and the Mann-Whitney test, respectively, and in case of categorical data using Fisher's exact test and the chi-squared test, respectively. The level of significance was set as p < 0.05. RESULTS: Average duration of surgery (CASPAR: 100.6 min; conventional: 51.5 min; p < 0.0001) as well as average loss of haemoglobin (CASPAR: 4.5 mg/dL; conventional: 3.3 mg/dL; p = 0.0002) differed significantly, whereas the incidence of complications (CASPAR: two dislocations, one sciatic paresis, one deep infection; conventional: one dislocation, two fissures), revision rate (CASPAR: 5.6 %; conventional: 2.9 %), and incidence of heterotopic ossifications (CASPAR: 30.6 %; conventional: 17.1 %) was comparable following both procedures (p > 0.05). Improvement of the Harris hip score also was comparable in both groups (CASPAR: 40.9 to 86.1 points; conventional: 39.5 to 88.0 points; p = 0.21), whereas improvement of the score according to Merle d'Aubigné and Postel was significantly greater following the manual procedure (CASPAR: 10.1 to 16.0 points; conventional: 8.3 to 16.6 points; p < 0.0001). Differences between the two groups were also significant regarding hip abductor function (CASPAR: 76.1 %; conventional: 93.8 % of the contralateral hip; p < 0.0001) and incidence of Trendelenburg's sign (CASPAR: 61.1 %; conventional: 25.7 %; p = 0.0014). CONCLUSION: The significant functional impairment following robotic assisted THA should be taken critically into consideration prior to initiating such procedure.

Adult↗

[Postoperative autologous retransfusion of collected shed blood after total knee arthroplasty with the cell saver].

AIM: The purpose of this study was to examine if it is possible to reduce transfusion of blood units by collecting shed blood with the Cell Saver for autologous retransfusion in total knee arthroplasty (TKA). METHOD: In 186 patients drainage blood was collected over a 6-h period after total knee arthroplasty with a Cell Saver system in order to make retransfusions if necessary. A tourniquet was used routinely throughout the operation. No preoperative blood donation was performed. In 19 patients preoperative haemoglobin levels were below 12 g/dL (group A, anaemic patients). In the other 167 patients (group B) the preoperative haemoglobin levels were higher. RESULTS: 4 patients (21 %) in group A received a homologous blood transfusion. Only 1 patient (0.6 %) in group B received one unit of erythrocyte concentrate (difference statistically significant, P < 0.001). In group A 8 patients (42 %) received 284 ml (145-621 ml) Cell-Saver concentrate on average, 38 patients (23 %) in group B received 358 mL (147-776 ml) Cell-Saver concentrate on average. CONCLUSION: With a risk lower than 1 % for patients without anaemia to get a homologous blood transfusion one can do without the more expensive preoperative blood donation in total knee arthroplasty if a tourniquet is used for the operation and a Cell Saver is used for facultative retransfusion of drainage blood.

Aged↗

[Effects of bisphosphonates in arthroplasty].

AIM: This study presents an overview of the general effects of bisphosphonates and in particular of their effects on different problems in joint arthroplasty. METHOD: First the chemical properties are described, then the biological effects. It is already known that bisphosphonates have effects on orthopaedic diseases and an increasing number of studies are investigating what effects can be achieved in joint arthroplasty with these substances. RESULTS: The bisphosphonates group was derived from industrial pyrophosphate which is used to prevent calcification. Bisphosphonates inhibit bone mineralisation and resorption. Several direct and indirect mechanisms are responsible for these effects. The inhibition of bone resorption is used to benefit patients suffering from various diseases causing increased bone resorption. Treatment with bisphosphonates results in greater bone density and improved mechanical bone quality. Indications for this treatment include osteoporosis, tumour-associated osseo-destruction, fibrous dysplasia and Paget's disease. Recent studies have shown that osseo-integration of metal implants is accelerated and periprosthetic bone loss, which is caused by various different mechanisms during the lifetime of an implant, can be reduced. CONCLUSION: Bisphosphonates have been an established element in the treatment of bone metabolic disorders for many years. Their use in joint arthroplasty could become increasingly important.

Animals↗

[Postoperative autologous transfusion from blood drainage after total hip joint arthroplasty--how much value is really there?].

AIM: Are autologous blood transfusions sufficient or do we need the transfusion of unwashed or washed wound drainage blood in total hip arthroplasty? METHOD: 253 patients undergoing total hip arthroplasty were retrospectively randomized to autologous blood transfusion or transfusion of unwashed wound drainage. We compared the haemoglobin and haematocrit levels as well as the rate of complications. RESULTS: Postoperative blood salvage and reinfusion after total hip joint arthroplasty didn't show any advantages. In 10 % we saw complications after transfusion of unwashed wound drainage. CONCLUSION: We do not recommend the transfusion of wound drainage.

Arthroplasty, Replacement, Hip↗

Rates of total hip arthroplasty; a population-based study.

Three hundred eighty-one total hip arthroplasties were performed on residents of Olmsted County, Minnesota, during the period from 1969 to 1980, for a rate (adjusted for sex and age) of 44.6 per 100,000 person-years. Rates rose with age, were higher for women than men, and were higher among urban than rural residents of the county. If we assume that the Olmsted County experience is medically optimal and apply it to the 1980 United States population, we calculate a national requirement of over 100,000 total hip arthroplasties per year, well above the current actual figure. If this calculated number of total hip arthroplasties were actually performed each year, over 1.4 million hospital days would be required, and direct medical costs would probably exceed $1 billion annually.

Age Factors↗

Predictors of rehospitalization for symptomatic venous thromboembolism after total hip arthroplasty.

BACKGROUND: Recent studies have shown that symptomatic venous thromboembolism after total hip arthroplasty most commonly develops after the patient is discharged from the hospital. Risk factors associated with these symptomatic thromboembolic events are not well defined. METHODS: Using administrative data from the California Medicare records for 1993 through 1996, we identified 297 patients 65 years of age or older who were rehospitalized for thromboembolism within three months after total hip arthroplasty. We compared demographic, surgical, and medical variables potentially associated with the development of thromboembolism in these patients and 592 unmatched controls. RESULTS: A total of 89.6 percent of patients with thromboembolism and 93.8 percent of control patients were treated with pneumatic compression, warfarin, enoxaparin, or unfractionated heparin, alone or in combination. In addition, 22.2 percent and 29.7 percent, respectively, received warfarin after discharge. A body-mass index (the weight in kilograms divided by the square of the height in meters) of 25 or greater was associated with rehospitalization for thromboembolism, with an odds ratio of 2.5 (95 percent confidence interval, 1.8 to 3.4). In a multivariate model, the only prophylactic regimens associated with a reduced risk of thromboembolism were pneumatic compression in patients with body-mass indexes of less than 25 (odds ratio, 0.3; 95 percent confidence interval, 0.2 to 0.6) and warfarin treatment after discharge (odds ratio, 0.6; 95 percent confidence interval, 0.4 to 1.0). CONCLUSIONS: In patients who underwent total hip arthroplasty, a body-mass index of 25 or greater was associated with subsequent hospitalization for thromboembolism. Pneumatic compression in patients with a body-mass index of less than 25 and prophylaxis with warfarin after discharge were independently protective against thromboembolism.

Aged↗

Correlates with comfort and function after total shoulder arthroplasty for degenerative joint disease.

Although most patients are improved after shoulder arthroplasty, the degree of improvement is variable. The factors contributing to this variability are not well understood. In particular, little information is available regarding the preoperative characteristics of the patient that may influence the quality of the result. This study correlated patient demographics, preoperative health status, and preoperative shoulder function with 3 outcome metrics: comfort, physical role function, and shoulder-specific function. One hundred thirty-four shoulders having total shoulder arthroplasty for degenerative glenohumeral joint disease had an average follow-up of 3.4 +/- 1.8 years. The SF-36 Comfort score improved from 39 to 61 (P < .0001). The SF-36 Physical Role Function score improved from 30 to 52 (P < .0001). The average number of Simple Shoulder Test functions performable (out of 12) improved from 4 to 9 (P < .0001). The strongest correlates with postoperative comfort included preoperative physical function (P < .0001), general health (P < .0001), and social function (P < .001). The strongest correlates with postoperative physical role function included preoperative physical function (P < .0001) and general health (P < .001). The strongest correlates with postoperative shoulder function included male gender (P < .0001), and preoperative physical function (P < .0001), social function (P < .0001), mental health (P < .0001) and shoulder function (P < .0001). These data indicate that the overall well-being of the patient before surgery is strongly correlated with the quality of the outcome from total shoulder arthroplasty for degenerative glenohumeral joint disease.

Adult↗

Functional outcome comparison of semiconstrained and unconstrained total elbow arthroplasties.

Twenty-six patients, each of whom had undergone either a semiconstrained (linked) or an unconstrained (unlinked) total elbow arthroplasty, were examined specifically to evaluate the restoration of function with respect to activities of daily living. The functional outcomes of these 2 groups were then compared to identify any significant differences. All of the unlinked/unconstrained prostheses were Ewald total elbow arthroplasties; the linked/semiconstrained prostheses, all of which were performed by a single surgeon, were Mayo-Coonrad prostheses. Follow-up radiographs, taken to rule out loosening or failure of the prosthesis as a cause for functional deficits, were available for review for 25 elbows. There were 14 elbows in 13 patients who had semiconstrained prostheses and 12 elbows in 10 patients who had unconstrained total prostheses. Average age at the time of elbow replacement surgery was 62.8 years (range, 47-75 years) for the semiconstrained group and 63.1 years (range, 54-74 years) for the unconstrained group. The semiconstrained group consisted of 8 female and 6 male elbows; the unconstrained group consisted of 10 female and 2 male elbows. Follow-up averaged 35.5 months (range, 24-73 months) in the semiconstrained group and 73 months (range, 27-110 months) in the unconstrained group. Twenty-two operations were performed for rheumatoid arthritis, 3 for posttraumatic humeral nonunion, and 1 for posttraumatic degenerative arthritis. Two elbows required revision, one (in the semiconstrained group) for aseptic loosening and the other (in the unconstrained group) for metal synovitis and pain from a chronically dislocated prosthesis; both of these elbows were considered failures and excluded from the functional comparison. No significant differences in functional performance were found, and no elbows demonstrated progressive radiolucencies suggestive of loosening. With the exception of 1 patient (in addition to the patients who had revisions) with a dislocated unconstrained prosthesis, all patients were satisfied with the procedure. It appears that when it is properly performed, total elbow arthroplasty with either type of prosthesis yields satisfactory functional results.

Activities of Daily Living↗

The effect of articular malposition after total shoulder arthroplasty on glenohumeral translations, range of motion, and subacromial impingement.

The articular surface of the normal humeral head has a variable posterior and medial offset with respect to the central axis of the humeral shaft. Recreation of the normal humeral head shaft offset is postulated to be an important consideration during shoulder arthroplasty. However, the effect of humeral head malposition is unknown. The purpose of this study was to determine the effect of articular malposition after total shoulder arthroplasty on glenohumeral translation, range of motion, and subacromial impingement. Twenty-one human cadavers were dissected and tested with the use of an active or passive shoulder model. Range of motion and translation were recorded by means of an electromagnetic tracking device. The experiment was performed in 2 phases. For kinematics study, 11 cadaver shoulders were positioned both passively and actively from maximum internal rotation to maximum external rotation at 90 degrees of total elevation in the scapular plane. Three rotator cuff and 3 deltoid muscle lines of action were simulated for active joint positioning. Passive joint positioning was accomplished with the use of a torque wrench and a nominal centering force. The testing protocol was used for the natural joint as well as for 9 prosthetic head locations: centered and 2- and 4-mm offsets in the anterior, posterior, inferior, and superior directions. Repeated-measures analysis of variance was used to test for significant differences in the range of motion and translation between active and passive positioning of the natural joint as well as all prosthetic head positions. (2) For impingement study, 10 cadaver shoulders were used in a passive model, loading the tendons of the rotator cuff with a 30-N centering force. The humerus was passively rotated from maximum internal rotation (1500 Nmm) to maximum external rotation (1500 Nmm) by means of a continuous-recording digital torque wrench. Trials were performed with the use of centered, 4-, 6-, and 8-mm offset heads in the anterior, posterior, superior, and inferior positions before and after removal of the acromion and coracoacromial ligament. The relation between change in mean peak torque (with and without acromion), passive range of motion, and humeral head offset was analyzed by means of repeated-measures analysis of variance. In the kinematics study, total range of motion and all humeral translations were greater with passive joint positioning than with active positioning (P =.01) except for total superior-inferior translation and superior-inferior translation in external rotation. Anterior to posterior humeral head offset was associated with statistically significant changes in total range of motion (P =.02), range of internal rotation (P =.02), range of external rotation (P =.0001), and total anterior-posterior translation (P =.01). Superior to inferior humeral head offset resulted in statistically significant changes in total range of motion (P =.02), range of internal rotation (P =.0001), anterior-posterior translation during external rotation (P =.01), and total superior-inferior translation (P =.03). In the impingement study, there was a significant increase in torque from centered to 4-mm inferior offset (P =.006), 6-mm inferior offset (P <.001), and 8-mm inferior offset (P <.001). There was no significant increase in torque with superior, anterior, and posterior offsets. Glenohumeral motion significantly decreased from 129 degrees for centered head to 119 degrees for 8-mm superior (P =.002), 119 degrees for 8-mm anterior (P =.014), 118 degrees for 8-mm inferior (P <.001), and 114 degrees for 8-mm posterior (P =.001). Humeral articular malposition of 4 mm or less during prosthetic arthroplasty of the glenohumeral joint may lead to small alterations in humeral translations and range of motion. Inferior malposition of greater than 4 mm can lead to increased subacromial contact; offset of 8 mm in any direction results in significant decreases in passive range of motion. Therefore if subacromial contact is to be minimized and glenohumeral motion maximized after shoulder replacement, anatomic reconstruction of the humeral head-humeral shaft offset to within 4 mm is desirable.

Adult↗

The magnitude and durability of functional improvement after total shoulder arthroplasty for degenerative joint disease.

So that patients with degenerative glenohumeral joint disease who wish to consider total shoulder arthroplasty will be better informed, we sought to document the magnitude and durability of the improvement in shoulder function after this procedure. The function of 124 shoulders with primary degenerative joint disease was documented by patient self-assessment with the Simple Shoulder Test before and sequentially after total shoulder arthroplasty performed with a standardized technique. Patients reported that they could perform 3.8 +/- 0.3 (SEM) of the 12 Simple Shoulder Test functions before surgery. The total number of performable functions was consistent at different follow-up intervals: 8.0 +/- 0.4 at 6 months, 9.5 +/- 0.4 at 1 year, 10.0 +/- 0.3 at 2 years, 9.2 +/- 0.4 at 3 years, 9.6 +/- 0.4 at 4 years, and 10.0 +/- 0.4 at 5 years. We conclude that total shoulder arthroplasty can provide substantial and durable improvement in shoulder function.

Aged↗

Shoulder arthroplasty for proximal humeral malunions: long-term results.

Between 1976 and 1997, 50 shoulders with proximal humeral malunions in 50 patients were treated with hemiarthroplasty or total shoulder arthroplasty and followed up for a mean of 9 years (range, 2-21 years) or until the time of revision surgery. Of these, 13 had a 4-part malunion, 24 had a 3-part greater tuberosity malunion, 6 had a 2-part greater tuberosity malunion, and 7 had a 2-part head segment malunion. Articular incongruity resulted from an articular surface step-off in 5 shoulders, from osteonecrosis in 19, and from secondary degenerative arthritis in 26. Shoulder arthroplasty resulted in significant pain relief (P <.005). At most recent follow-up, shoulder pain was more intense in patients who had initial operative treatment of their fracture, in those with osteonecrosis, and in those who had arthroplasty less than 2 years after their fracture. Active elevation improved from 65 degrees to 102 degrees on average, and external rotation improved from 12 degrees to 35 degrees on average. There was significantly less postoperative motion in those who had initial operative treatment of their fracture or who underwent tuberosity osteotomy. Of the 24 shoulders undergoing tuberosity osteotomy, 14 healed in good position, 4 had a nonunion develop, 3 had some degree of malunion develop, and in 3 the tuberosity resorbed. On the basis of the Neer result rating, 12 shoulders had an excellent result, 13a satisfactory result, and 25 an unsatisfactory result. Unsatisfactory results occurred in 8 who underwent reoperation with component revision or removal and because of lack of postoperative motion in 14, moderate pain in 2, and patient dissatisfaction in 1. All shoulders with tuberosity nonunion or resorption had an unsatisfactory result.

Arthroplasty↗

The influence of the implant size on the outcome of unconstrained total knee arthroplasty.

INTRODUCTION: The influence of implant size on the results in unconstrained total knee arthroplasty has never been investigated before. PATIENTS AND METHODS: 133 patients with unconstrained total knee arthroplasty were examined (HSS Score, Knee Society Score) with consideration of the different sizes of femoral and tibial components and the thicknesses of the tibial inlays. The medium follow up was 41.2 months (8 months to 74 months). RESULTS: Although the different component sizes gained different results, the differences were not significant. The combination of two component sizes did not lead to a significant change of the results. The results of the Knee Society Score seemed to become worse with thinner polyethylene tibial inlays although these differences were not significant. CONCLUSIONS: In conclusion, implant size had no significant influence on the outcome of total knee arthroplasty. The combination of two implant sizes showed no disadvantage.

Adult↗

Outcome after total hip arthroplasty: Part I. General health evaluation in relation to definition of failure in the Swedish National Total Hip Arthoplasty register.

The Swedish National Total Hip Arthroplasty register, which was started in 1979, is one of the oldest national quality registers in the world and consists of over 160,000 primary operations and 12,500 revisions. The register identifies risk factors for poor outcomes related to the patient, implant and surgical techniques. The end-point for failure, i.e., revision, does not provide information about the patient's general health after the primary procedure. The aim of this study was twofold. First, to validate the end-point for failure in the Swedish National Total Hip Arthroplasty register and secondly, to study general health after total hip arthroplasty. We validated the outcome of 1,056 primary THRs randomly selected from the Discharge register in Sweden by comparing the data to the Swedish THA register. These patients had answered the SF-36 and Nottingham Health Profile questionnaires. By comparing the clinical outcome, measured as general health, with the results obtained from the register, we evaluated the importance of the end-point for failure. We found that the end-point was useful, but further evaluations are desirable. Patients operated on with hip replacement do very well up to 10 years postoperatively and those who are not revised have good general health. The findings in this study can be used as a reference for others as it shows results from a national register, with a random selection of the study cohort.

Activities of Daily Living↗

Debridement arthroplasty for osteoarthrosis of the elbow: 50 patients followed mean 5 years.

The characteristics and surgical outcome of debridement arthroplasty were investigated in athletes and manual laborers with osteoarthrosis of the elbow. There were 26 elbows in athletes, and 24 elbows in laborers. The mean age was 32 years in athletes and 50 years in laborers. The osteoarthrosis was mainly mild in athletes, but moderate or severe in laborers. Debridement arthroplasty, consisting of resection, osteophytes and removal of loose bodies, was performed in all cases. The medial approach was most frequently employed. Surgery relieved pain and improved range of motion at an average follow-up of 59.5 months. Evaluation of the long-term outcomes at more than 5 years showed recurrence of mild osteoarthrosis with minimal symptoms. Debridement arthroplasty is an effective treatment in athletes and manual laborers with osteoarthrosis of the elbow.

Adolescent↗

The Richards type II patellofemoral arthroplasty: 26 cases followed for 1-20 years.

We followed 26 Richards type II patellofemoral arthroplasties in 24 patients (19 women) for a mean of 11 (1-20) years. Their mean age was 59 (22-90) years. The preoperative diagnoses were primary patellofemoral arthrosis in 17 cases and secondary arthrosis in 9 (8 malalignment, 1 patellar fracture). Patellectomy was later performed for persistent pain or patellar malalignment in 3 cases and a conversion to a total knee arthroplasty for progressive tibio-femoral degeneration or patella malalignment in 2. The mean Knee Society knee score for 21 knees at follow-up was 90 (65-100) points. The patients rated the results of surgery in 9 knees as excellent, 7 good, 4 improved, and 1 unimproved at follow-up. None of the implants showed signs of loosening or infection. The Richards type II patellofemoral arthroplasty yields acceptable long-term results in patients with isolated end-stage patellofemoral osteoarthrosis. Patient selection and patella alignment are important.

Adult↗

No functional impairment after Robodoc total hip arthroplasty: gait analysis in 25 patients.

The Robodoc total hip replacement procedure requires a wider exposure of the proximal femur, especially of the greater trochanter, than the standard procedure. Moreover, the leg must be placed in a rigid leg-holder apparatus to obtain fixation in maximal hip adduction and external rotation. This may impair the hip abductors and reduce hip abduction in the mid- and terminal stance phase of the cycle. In this study we compared patients after Robodoc and conventional total hip arthroplasty with three-dimensional gait analysis (VICON System, Oxford Metrics, Oxford, U.K.) to assess the kinematics of the pelvis and hip. 25 patients underwent total hip replacement by means of the Robodoc total hip arthroplasty system, 25 patients were treated with conventional total hip replacement, and 40 healthy volunteers served as controls. None of the patients undergoing total hip replacement, robotic or conventional, obtained normal kinematic gait patterns 6 months after surgery. However, the reduction in hip abduction did not differ significantly in patients undergoing robotic or conventional total hip arthroplasty, which suggests that the robotic procedure did not impair hip abductor function more than the conventional method.

Aged↗