Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83Linked to original sources

Surface treatments to improve bond strength in removable partial dentures.

The metal and resin interface of removable partial dentures is weakened by the poor bond strength between the two materials. This study was designed to test the hypothesis that surface treatments--consisting of air abrasion, with aluminum oxide, tin plating and oxidation, and silanation, either alone or in combination--will improve the bond strength of acrylic resin to metal. Statistical analysis revealed that air abrasion, tin plating/oxidation, and silanation all showed significantly higher bond strength than either abrasion and tin plating, abrasion and silanation, or abrasion alone. Air abrasion demonstrated the greatest effect on improving bond strength. The mean bond strength of samples subjected to a combination of air abrasion, tin plating and oxidation, and silanation was significantly greater than any other combination treatment.

Acrylic Resins↗

Heat-released stress in acrylic dentures.

Dimensional changes in an acrylic resin denture blank that are sufficient to cause changes in fit on a gypsum cast occur primarily when the dentures are heated in water to a temperature of 90 degrees C or more. The poor correlation between observed fit and the intermolar distance change indicates that the dimensional change of dentures is much more complex than suggested previously and may be the product of factors that are not as yet fully understood. Enough heat to cause distortion of the denture can be produced during the process of grinding the denture. It should be recognized by the dentist, the dental assistant, and the dental laboratory technician that denture resins are sensitive to the techniques that are used in finishing. Overheating even small regions may allow localized dimensional changes that result in distortion of the denture.

Acrylic Resins↗

Residual methyl methacrylate monomer, water sorption, and water solubility of hypoallergenic denture base materials.

STATEMENT OF PROBLEM: Denture base materials have the potential to cause irritation and allergic reaction to the oral mucosa. Water sorption and water solubility of denture base resins affect dimensional behavior and denture stability. A correlation between residual monomer and water sorption exists. PURPOSE: This in vitro study compared the amount of residual monomer, quantity of water sorption, and solubility of 4 denture base materials purported to be hypoallergenic with those of a polymethyl methacrylate-based (PMMA) heat-polymerizing acrylic resin. MATERIAL AND METHODS: The denture base resins Sinomer (heat-polymerized, modified methacrylate), Polyan (thermoplastic, modified methacrylate), Promysan (thermoplastic, enterephthalate-based), and Microbase (microwave polymerized, polyurethane-based), which are purported to be hypoallergenic, and Paladon 65 (heat-polymerized, methacrylate, control group) were examined. Specimens of each material were tested for residual methyl methacrylate (MMA) monomer (% wt, n=3), amount of water sorption (microg/mm3, n=5) and water solubility (microg/mm3, n=5), according to ISO 1567:2000. The residual MMA monomer concentrations were determined by gas chromatography (GC). The data were analyzed with 1-way ANOVA and the Bonferroni-Dunn multiple comparisons post hoc analysis for each test variable (alpha=.05). RESULTS: Significantly lower residual MMA monomer was shown for Sinomer and Polyan compared to the PMMA control group (0.90 +/- 0.20% wt, P<.05). Sinomer contained 0.31% +/- 0.00% wt MMA monomer, and Polyan exhibited residual MMA monomer content of 0.44% +/- 0.01% wt. Promysan and Microbase did not contain detectable residual MMA. Water sorption of Promysan (16.21 +/- 0.96 microg/mm3) was significantly lower than Paladon 65 (23.04 +/- 3.13 microg/mm3, P<.0001), whereas water solubility of the hypoallergenic denture base materials (0.34-0.84 +/- 0.05-0.09 microg/mm3) was not significantly lower than the PMMA material (0.40 +/- 0.06 microg/mm3, P>.05). Except for Sinomer, the tested denture base resins passed the requirements of ISO 1567 regarding residual MMA monomer (<2.2% wt). Sinomer failed to comply with the requirements for residual MMA monomer because the manufacturer claimed that the material did not contain any MMA. The tested denture base materials fulfilled the requirements regarding water sorption (<32 microg/mm3) and solubility (<1.6 microg/mm3). CONCLUSION: The tested hypoallergenic denture base materials exhibited significantly lower residual monomer content than PMMA. Promysan and Microbase showed no detectable residual MMA.

Absorption↗

An impression tray hanger for disinfection.

This article describes in detail a method for making a holder for impression trays. The procedure uses a pattern that can easily be made in the office. A mold is made from the pattern and parts are processed in acrylic resin. Many parts can be made from the same mold and several holders can be made before it is necessary to remake the mold.

Acrylic Resins↗

Effect of metal strengthener's surface roughness on fracture resistance of acrylic denture base material.

The aim of this study was to clarify the effect of the surface roughness of various metal wires on the fracture resistance of the acrylic test specimens. The number of test groups compared were 16, and there were 30 test specimens in each group. The investigation showed that the surface roughening of the metal wires used to reinforce acrylic resin denture base material increased the fracture resistance of the test specimens. The best results were achieved by sandblasting. The differences in resistance were also statistically significant.

Acrylic Resins↗

Fluoride-releasing dental restorative materials.

In the 1940s, dentists observed that secondary caries was rarely associated with silicate cement restorations. While the relatively stable dimensional properties of those restorations were undoubtedly a factor in this fortunate circumstance, the fact that fluoride was inherent in the composition of the material received the greater credit. By the mid-1980s, a wide variety of fluoride-releasing dental restorative materials were available to dentists and dental consumers, and the cariostatic effect of fluoride ions on enamel caries had been demonstrated in many studies. This paper reviews much of the fluoride-related research conducted on fluoride-releasing amalgam, glass-ionomer cements, composites, primers, sealants, liners, acrylic resins, and orthodontic bracket bonding materials. The need for standardization of test methods is addressed, as is the need for more controlled clinical trials and additional research.

Acrylic Resins↗

In vitro wear of resin denture teeth.

STATEMENT OF PROBLEM: One of the most important physical properties of artificial teeth used in the restoration of the edentulous patient is wear resistance, and the ability of these teeth to maintain a stable occlusal relationship over time. PURPOSE: This study compared the in vitro wear of four different resin denture teeth against human enamel. MATERIAL AND METHODS: Five denture tooth samples opposing five enamel abraders were positioned in a mechanical wear testing device for two 5,000 cycle wear periods (total of 10,000 cycles) under a 13.4 N load. All tests were conducted in human saliva, and the wear was measured at the end of each test period. RESULTS: The wear of the Classic and Kenson acrylic resin denture teeth was much greater than the DB Plus and MLI composite teeth after 10,000 cycles. The wear of the KENSON denture tooth was also greater than the Classic tooth. No wear differences were found between the two composite teeth. CONCLUSIONS: The wear of DB Plus and MLI resin denture teeth was approximately 50% less than the wear of Classic and Kenson teeth when opposed by human enamel.

Acrylic Resins↗

Immunohistochemistry of matrix markers in Technovit 9100 New-embedded undecalcified bone sections.

Trabecular bone is routinely analysed by histomorphological-histometrical and immunohistochemical techniques as means of assessing the differentiation status of bone deposition and growth. Currently few embedding resins exist for which both morphological and immunohistochemical analyses can be performed on mineralised tissue. Paraffin, the standard embedding medium for bone enzyme and immunohistochemistry, can only be used on demineralised tissue, but then trabecular structure may be badly preserved. Methyl methacrylate (MMA), the resin of choice for undecalcified bone histology can only be used for bone immunohistochemistry if the usual, highly exothermic polymerisation procedure is avoided which destroys tissue antigenicity. Consequently, most current practices involve cutting samples in half to be processed in separate resins when more than one type of analysis is required. Technovit 9100 New is a low temperature MMA embedding system that is purported to significantly improve tissue antigenicity preservation allowing polymerisation at -20 degrees C. In this study, Technovit 9100 New-embedded undecalcified trabecular bone samples (adult human, young bovine and ovine) yielded immunolabelling with several bone matrix markers and preserved morphological features in 7 microm sections when stained with Masson-Goldner, von Kossa, or toluidine blue. Bone samples from all resins used were immunolabelled with antibodies against osteocalcin, alkaline phosphatase, osteopontin, osteonectin, bone sialoprotein and procollagen type I amino-terminal propeptide. Technovit-embedded bone yielded more reliable immunolabelling of the matrix proteins when compared with heat or cold-cured LR White or standard embedded MMA samples. Technovit 9100 New provided better routine histology than LR White, and was comparable to MMA. Results demonstrated that Technovit 9100 New can be used as a low-temperature acrylic resin embedding method for routine undecalcified bone histology, as well as for immunohistochemistry.

Acrylic Resins↗

The theoretical ratio of immunogold labeling of deplasticized epoxy sections and acrylic sections.

The purpose of this study was to predict the ratio of immunogold labeling of deplasticized epoxy sections and LR-White sections on the basis of theoretical considerations. Tissues used in experiments were pancreas, pituitary, kidney, thyroid, and fibrin. Antigens used as test proteins were glucagon, somatostatin, thyroglobulin, chromogranin A, ACTH (= Adrenocorticotropt hormone), amyloid A, and fibrinogen. These are proteins of different sizes. The quotient labelingdeplasticized/labelingLR-white was deduced theoretically and compared to measurements based on immunogold experiments to obtain a theoretical model with acceptable correlation to the measurements. This study describes a theory--expressed mathematically--for what happens at the molecular level in immunoelectron microscopy at the surface of deplasticized epoxy sections and acrylic sections. The theory explains why we normally get about the same amount of immunogold labeling using LR-White sections (acrylic resin) and deplasticized epoxy sections. Taking the nuances into account, the theory indicates increased usefulness of deplasticized epoxy sections when the diameter of the protein carrying the epitopes decreases.

Acrylic Resins↗

Fabrication of complete denture bases reinforced with polyethylene woven fabric.

Incorporation of 5 layers of woven, high-modulus polyethylene fiber into acrylic resin denture bases produces substantial improvements in mechanical properties and dimensional changes. A modified split-pack technique has been developed using conventional dental-laboratory compression molding to accommodate multiple layers of woven fabric in complete denture bases. A recess formed in the resin by a spacer allows the reinforcement to be embedded in the denture base without exposing the fibers. Embedded fibers do not compromise the esthetics of complete dentures.

Acrylic Resins↗

A new technique for determining the denture tooth bond.

Defective bonds between resin teeth and denture base material remain a continuing source of failure. Findings from the limited number of studies on this topic are diminished by the numerous experimental approaches adopted. National and international standard specifications also adopt different methods of specimen preparation and physical straining. A critical appraisal of the various standards is carried out and a new procedure for determining the denture tooth to acrylic resin bond is described. A study using this technique found that physical modification and alginate contamination of the tooth had no significant effect on the bond strength. Ineffectual wax elimination was the main cause of failure.

Acrylic Resins↗

Contact leukoderma caused by patch testing with dental acrylics.

Several chemicals are capable of inducing contact leukoderma. Here we report on a dental nurse who had been investigated elsewhere at a dermatology clinic 2.8 years earlier because of suspected occupational fingertip dermatitis. She had been patch tested on her upper arm with dental acrylic resins "as is." These strong concentrations of patch test substances caused a severe allergic reaction in the upper arm, and the patch test sites have remained vitiliginous for 2.8 years. Active sensitization did not take place because the patient had been sensitized earlier as shown by the allergic 2-day readings with acrylics during the first patch test session. It is assumed that acrylates induced contact vitiligo, but the dental acrylics may have also contained other chemicals (eg, hydroquinone or phenolic substances) capable of causing vitiligo. The main point to be learned from the present results is that dental acrylics should never be patch tested "as is." We also discourage the practice of use tests, open tests, or repeated open patch tests with undiluted dental acrylics because of the risk of active sensitization from single exposure.

Acrylic Resins↗

Potential risk of serious oral infections in the diabetic patient: a clinical report.

Diabetes has many manifestations, including increased vulnerability to bacterial and fungal infections, that may be of concern to the dental profession. Oral candidosis and other opportunistic fungal infections may be early, nonspecific signs of uncontrolled diabetes. Rhinocerebral involvement often extends to the paranasal sinuses, pharynx, palate, orbit, and brain, causing severe tissue destruction and necrosis. This clinical report describes a young woman with diabetes who developed mucormycosis of the maxilla. Tissue destruction resulted in loss of the entire premaxilla, the anterior half of the hard palate, and all maxillary teeth except for the right and left second molars. An interim clear acrylic resin prosthesis was fabricated to restore facial contours and speech and to allow mastication. This prosthesis subsequently was duplicated, and teeth were added for improved lip support, esthetics, and mastication.

Acrylic Resins↗

The attempts of retarding the release of nitroglycerin from granules.

The effect of Eudragit S, RL, or RS and ethylcellulose on the rate of release of nitroglycerin from granules has been studied. It was shown that Eudragits (acryl resins) and ethylcellulose decrease the rate of release of nitroglycerin from granules. The retarding effect depends on the amount and the kind of a retarding agent. Eudragit RS was the most effective one.

Acrylic Resins↗

Plaque retention on teeth restored with full-ceramic crowns: a comparative study.

Plaque accumulation was determined by using the plaque index of Silness and Löe on 150 crowns in 19 patients. The plaque indices for individual crowns in a quadrant were compared to the average plaque index of the quadrant in which the crowns were inserted (quadrant plaque index = 100%). This comparative study showed that Cerestore full-ceramic crowns have little soft debris retention (32%). Ceramometal crowns (90%), natural teeth (110%), cast gold restorations (148%), and acrylic resin veneer crowns (152%) have increasing plaque retention. The results indicate that ceramics are easily cleaned and exhibit low plaque retention. Increasing the area of ceramic surfaces on restorations decreases plaque retention.

Acrylic Resins↗

Soft tissue neck radiography for displaced dental prostheses.

Modern dental prostheses continue to be made of acrylic resins which can be difficult or impossible to recognize by conventional radiography. We discuss the difficulties that can arise and the recognition of such objects in the neck using three illustrative cases.

Acrylic Resins↗

Posterior peripheral seal distortion related to height of the maxillary ridge.

A statistically significant positive relationship exists between ridge height of a cast and dimensional changes in the posterior peripheral seal region of its denture base. This dimensional change might be clinically insignificant, but it should not be ignored. The relationship between distortion of the denture base and composition of the denture teeth is not significant. The relationship of distortion of the denture base at the region of the posterior peripheral seal and variables of ridge height and tooth composition were studied. A positive relationship exists between ridge height and distortion, but no significant relationship was found between dimensional change and the use of porcelain or acrylic resin teeth. Using computer analysis, an equation, table, and curve were derived for values of expected dimensional change in the posterior peripheral seal region related to various ridge heights.

Acrylic Resins↗