Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “diagnostics”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82Linked to original sources

Spinal epidural metastasis as the initial manifestation of malignancy: clinical features and diagnostic approach.

The objective of our study was to delineate clinical features and specific diagnostic and therapeutic implications of spinal epidural metastasis (SEM) occurring as the initial manifestation of malignancy (IMM)-a less common event than SEM in the setting of previously established malignancy (PEM). We performed a retrospective review of the clinical histories of 337 patients seen at Mayo Clinic with a radiographically verified diagnosis of SEM between January 1, 1985, and December 31, 1993. Twenty percent of all cases of SEM occurred as SEM-IMM. Carcinoma of the lung, cancer of unknown primary site, multiple myeloma, and non-Hodgkin's lymphoma were disproportionately represented in SEM-IMM, together accounting for 78% of SEM-IMM patients and only 26% of SEM-PEM patients. Inversely, breast and prostate carcinoma contributed only 12% of SEM-IMM patients but 51% of SEM-PEM patients. Only 27% of patients with SEM-IMM had nonspecific symptoms suggesting malignancy, and in only 24% did the history or physical examination suggest the primary site of malignancy. Percutaneous needle biopsy of the vertebral lesion was diagnostic of malignancy in 18 of 19 patients (95%), and no complications ensued. Fifteen patients underwent diagnostic laminectomy with biopsy, and one had a fatal complication. Survival after the diagnosis of SEM did not differ between patients with SEM-IMM and those with SEM-PEM; the median survival was 6.6 months. SEM not uncommonly occurs as the presentation of malignancy, and often it produces the only symptoms or signs of malignancy. The great majority of neoplasms presenting with SEM are carcinomas of the lung, unknown primary lesions, and hematologic malignancies. Computed tomography-guided needle biopsy is a safe, efficacious means of diagnosing malignancy, allowing for rational diagnostic workup and staging. In most patients it obviates a diagnostic spinal surgical procedure.

Adolescent↗

Mass screening in low-income populations: the challenges of securing diagnostic and treatment services in a national cancer screening program.

Funding for many mass screening programs for low-income and uninsured populations provides resources for screening tests, yet only rarely does it provide coverage for necessary follow-up diagnostic and treatment services. The National Breast and Cervical Cancer Early Detection Program (NBCCEDP), a federally funded initiative that provides cancer screening to low-income uninsured and underinsured women, covers some diagnostic follow-up tests and no treatment services. We conducted in-depth case studies of seven state programs participating in the NBCCEDP to investigate the strategies and approaches being used to secure diagnostic and treatment services. The results suggest that the program relies on a patchwork of resources--at state and local levels--to provide diagnostic and treatment services. This includes a number of components of local safety nets, all of which are unstable and have uncertain futures. Public health disease-screening initiatives need to reconsider the feasibility of continued reliance on case-by-case appeals to the local safety net for diagnostic follow-up and treatment services.

Breast Neoplasms↗

Non-radical diagnostic biopsies do not negatively influence melanoma patient survival.

BACKGROUND: In fair-skinned Caucasian populations both the incidence and mortality rates of cutaneous melanoma have been increasing over the past decades. With adjuvant therapies still being under investigation, early detection is the only way to improve melanoma patient survival. The influence of incisional biopsies on melanoma patient survival has been discussed for many years. This study investigates both the influence of diagnostic biopsy type and the presence of residual tumor cells in the re-excision specimen on disease free and overall survival. METHODS: After (partial) removal of a pigmented skin lesion 471 patients were diagnosed with stage I/II melanoma and underwent re-excision and a sentinel node biopsy. All patients were followed prospectively, mean follow up >5 years. Patients were divided according to their diagnostic biopsy type (wide excision biopsy, narrow excision biopsy, excision biopsy with positive margins and incisional biopsy) and the presence of residual tumor cells in their re-excision specimen. Survival analysis was done using Cox's proportional hazard model adjusted for eight important confounders of melanoma patient survival. RESULTS: The diagnostic biopsy was wide in 279 patients, narrow in 109 patients, 52 patients underwent an excision biopsy with positive margins and 31 patients an incisional biopsy. In 41 patients residual tumor cells were present in the re-excision specimen. Both the diagnostic biopsy type and the presence of tumor cells in the re-excision specimen did not influence disease free and overall survival of melanoma patients. CONCLUSIONS: Non-radical diagnostic biopsies do not negatively influence melanoma patient survival.

Biopsy↗

Evaluation of a training and diagnostic ultrasound service for general practitioners using narrowband ISDN.

We carried out a four-month pilot study of telemedicine for the delivery of training and diagnostic ultrasound services for general practitioners (GPs). Two health centres and a district general hospital were linked using ISDN (128 kbit/s) and PC-based videoconferencing units. Sixteen videoconferencing sessions were conducted, with 64 patients scanned over the ISDN link for a range of clinical conditions. Nine cases of pathology were demonstrated and confirmed by a consultant radiologist. A total of 229 images were transmitted using the store-and-forward facility, of which 194 (85%) images were of diagnostic quality and 35 (15%) were regarded as non-diagnostic. Allowing for sampling error, we would expect 79-89% of stored images to provide diagnostic information at a 95% confidence level. A total of 115 store-and-forward images (SAFI) were randomly selected and compared with hard-copy images (HCI) for technical quality. There was a significant difference in the quality of images. The results show that SAFI are far superior to HCI, traditionally used by clinicians for making primary diagnosis and that the superior quality of the SAFI improved diagnostic accuracy. This pilot study showed a high degree of confidence in videoconferencing for training GPs to carry out ultrasound clinics, enhancing their ability to make accurate diagnoses, and providing them with immediate access the second and higher opinion.

Education, Medical, Continuing↗

An economic evaluation of the use of rare earth screens to reduce the radiation dose from diagnostic X-ray procedures in Israel.

In Israel the diffusion of rare earth screen technology has been limited. These screens could halve the radiation dose to the patient from diagnostic X-ray radiography, with little managerial effort and without being detrimental to the quality of the diagnostic image. We estimated the total effective dose from diagnostic film radiography capable of reduction by the use of rare earth screens, based on the number of hospital and ambulatory diagnostic X-ray procedures. This number was multiplied by the computed radiation dose per body site for a series of diagnostic procedures. The annual dose was approximately 0.53 mSv per head, approximately half of which could be averted by the introduction of rare earth screen technology. Based on a fatality risk of 3% Sv-1, it is estimated that the adoption of rare earth screen technology might reduce the annual incidence of cancer by some 93 cases, half of which would be fatal after an average latency period of 18.4 years. The cost of purchasing rare earth screens on a nationwide basis is approximately $3.0 million. This cost is outweighed by a saving of $9.6 million in X-ray tube replacement costs over the period 1997-2006. Government legislation enforcing the use of rare earth screens is essential, because of the lack of prestige associated with acquiring rare earth technology, as well as institutional reluctance to accept the external benefits of reduced morbidity and mortality and/or to extend budgetary time horizons.

Cost-Benefit Analysis↗

Diagnostic agreement of two calcaneal ultrasound devices: the Sahara bone sonometer and the Achilles+.

Quantitative ultrasound for the assessment of skeletal status is an evolving method in the diagnosis of osteoporosis. In this cross-sectional study we investigated the diagnostic agreement between the Sahara bone sonometer and the Achilles+ with respect to broadband ultrasound attenuation (BUA), speed of sound (SOS) and stiffness/quantitative ultrasound index (QUI). 309 healthy females without diseases or medications known to influence bone metabolism (with the exception of oestrogen) were recruited at two participating centers (Erlangen and Berlin). 33% of subjects were taking oestrogens. There was no significant difference in BUA, SOS, and stiffness/QUI between oestrogen and non-oestrogen takers. In vivo precision (expressed as root mean square coefficient of variation) was calculated from two repeat measurements and analyzed in both centres. Mean values were 1.57% (BUA Achilles+), 3.64% (BUA Sahara), 0.35% (SOS Achilles+), 0.39% (SOS Sahara), 2.22% (stiffness Achilles+) and 3.04% (QUI Sahara). Between the two devices we observed a strong correlation for SOS (r=0.89, p<0.01) and stiffness/QUI (r=0.83, p<0.01), and a moderate correlation for BUA (r=0.68, p<0.01). All parameters were moderately negatively associated with age (r=-0.38 to -0.48; p<0.01 for all correlations). Kappa (kappa) scores used to report diagnostic agreement were calculated for tertiles and "equivalent T-scores". The tertiles divide the cohort on both scanners into the same number of subjects above and below a given T-score. Diagnostic agreement using tertiles was poor to moderate (kappa< or =0.51). Diagnostic agreement using equivalent T-score agreement, again, was poor to moderate for BUA but fair to good for SOS and stiffness/QUI (0.59< or =kappa< or =0.73). We conclude that diagnostic agreement between the two devices is at best comparable to the agreement of a dual X-ray absorptiometry measurement using the same densitometer at two different skeletal sites. It is therefore insufficient to compare directly two measurements of an individual patient on both ultrasound devices. Standardization of quantitative ultrasound is very much needed.

Adult↗

Factors determining the diagnostic accuracy of digitized conventional intraoral radiographs.

A number of factors may determine the diagnostic accuracy of digitized intraoral radiographs. Conventional film radiographs were digitized with three different digitizers, a laser-scanner, a drum-scanner and a TV camera. Digital images, varying in pixel size, grey level and image processing, were displayed on three different video-monitors and assessed by 10 dentists. The detectability of incipient proximal surface caries was used as an index of the diagnostic accuracy and the effect of the different factors compared by means of receiver operating characteristic (ROC) analysis. Images digitized by the drum-scanner were found to have the best diagnostic accuracy. Sufficient diagnostic accuracy could be attained on the low-cost video monitor of a personal computer. Digital images with a pixel size of 100 microns and 32 grey levels were found to be acceptable for intraoral radiographs for diagnostic purposes. These results provide a practical guide for establishing a digital image acquiring system for any intraoral radiographs, reducing demands on data storage to a minimum.

Analysis of Variance↗

Diagnostic performance of general dental practitioners after lecture in identifying post-menopausal women with low bone mineral density by panoramic radiographs.

OBJECTIVES: Mandibular cortical erosion detected on panoramic radiographs may be useful for identifying post-menopausal women with low skeletal bone mineral density (BMD). The purposes of this study were to calculate the diagnostic performance of general dental practitioners (GDPs) who attended a lecture on identifying post-menopausal women with low BMD from findings on panoramic radiographs and to evaluate the influence of GDPs' age on diagnostic performance. METHODS: After a 1 h lecture, 111 GDPs were asked to classify the mandibular cortex (normal or eroded) on panoramic radiographs obtained from 100 post-menopausal women who have had skeletal BMD assessment. Low BMD was defined as a BMD T score of -1.0 or less. Diagnostic performance was analysed by comparing two groups classified by mandibular cortex (women with normal cortex and women with any eroded cortex) with those classified by BMD (women with normal BMD and women with low BMD). RESULTS: The mean sensitivity, specificity, positive predictive value, negative predictive value, accuracy and likelihood ratio for a positive risk result were 73.0% (95% confidence interval [CI]; 71.3 to 74.7%), 49.0% (95% CI; 46.4 to 51.5%), 66.9% (95% CI; 66.0 to 67.8%), 57.0% (95% CI; 55.8 to 58.2%), 62.9% (95% CI; 62.1 to 63.7%) and 1.51 (95% CI; 1.44 to 1.58), respectively. GDPs' age did not influence diagnostic performance. CONCLUSIONS: Our results suggest that 73.0% of women who had low skeletal BMD can be identified by GDPs after a lecture on the use of panoramic radiographs as an aid in diagnosing low BMD; however, the diagnostic performance may not be influenced by GDPs' age.

Adult↗

Diagnostic accuracy of two software modalities for detection of caries lesions in digital radiographs from four dental systems.

OBJECTIVE: To compare the caries diagnostic accuracy of two software modalities used in the assessment of digital radiographs obtained with four different dental systems, and to evaluate whether the software used for image assessment influenced the mutual comparison of those four dental systems relating to their caries diagnostic accuracy. METHODS: Under in vitro and standardized conditions 122 teeth (with 228 unrestored approximal and 99 occlusal surfaces) were radiographed in blocks of 3 test teeth and 2 non-test teeth using two storage phosphor plate systems: Digora (Soredex, Helsinki, Finland) and DenOptix (Gendex, Dentsply, Milan, Italy) and two charge coupled device (CCD)-based sensor systems: Dixi (Planmeca, Helsinki, Finland) and Sidexis (Sirona, Bensheim, Germany). The images were displayed and examined in two software modalities: their own dedicated software and a general software. Three observers examined all images for the presence of approximal enamel and dentine and occlusal dentine caries lesions using a 5-point confidence scale. The true presence of caries was validated by ground section histology. The diagnostic accuracy of the software modalities was expressed as ROC curve areas (A(z)) and differences between modalities were tested by paired t-test. Comparison of systems was analysed by post hoc t-test. RESULTS: Results of approximal and occlusal surfaces assessed together revealed nearly identical mean A(z) with the two software modalities on images obtained with the Digora (A(z)=0.71) and DenOptix (A(z)=0.72) systems. On Dixi images the mean A(z) was 0.75 using the system's own software and 0.73 using the general software. On Sidexis images the corresponding mean A(z)s were 0.79 and 0.75. None of those differences were significant. CONCLUSION: No significant difference in caries diagnostic accuracy was found between two software modalities used for examination of digital radiographs obtained with four different digital systems, and the software modality did not influence the mutual rank of the four systems relating to their diagnostic accuracy.

Data Display↗

The clinical and diagnostic imaging findings of osteosarcoma of the jaw.

OBJECTIVE: To clarify the valuable clinical features and diagnostic imaging findings regarding the diagnosis of osteosarcoma of the jaw (OSJ). MATERIALS AND METHODS: The initial symptoms and diagnostic imaging findings of 10 patients with OSJ were analysed. The points analysed on the diagnostic images were as follows: any widening of the periodontal ligament space of the teeth on the periphery of the OSJ; the presence of radial spicules and Codman's triangle; any signs of bone destruction; and the patterns of osteogenesis. RESULTS: All patients had pain and/or swelling of the affected site, and all OSJs, except for one edentulous case, showed a widening of the periodontal ligament space of the teeth on the periphery of the OSJ. Radial spicules or Codman's triangle were observed in only three cases (30%). Four out of five mandibular OSJs were osteolytic or osteolytic dominant with bone destruction, while, in contrast, four out of five maxillary OSJs were osteogenic or osteogenic dominant, and three out of the four maxillary OSJs did not show bone destruction. The osteogenic OSJ without bone destruction was similar to some benign cemento-osseous lesions of the jaw and thus was difficult to diagnose as OSJ based on the diagnostic imaging findings alone. CONCLUSION: Even though some OSJ showed features similar to the benign tumours of the jaw bone based on the diagnostic imaging findings, the pain and swelling of the affected site, and the widening of the periodontal ligament space of the teeth on the periphery of OSJ were considered to be common findings, which may help in making an accurate diagnosis of OSJ in this limited series.

Adolescent↗

[Diagnostic values of BAL and TBLB in patients with interstitial lung diseases].

In order to evaluate the diagnostic values of bronchoalveolar lavage (BAL) and transbronchial lung biopsy (TBLB) in interstitial lung diseases, we made a retrospective study of a total of 43 patients all of whom underwent examinations for both conditions at the same time. In the BAL examination, fractional analyses of cell differential counts were applied to the first 30 ml lavage (FBAL-I, bronchial lavage) and to the following 50 ml aliquot of the second and third lavages (FBAL-II and -III, the latter supposedly alveolar lavage) lavages respectively. This technique revealed the unique characteristics of bronchial and alveolar inflammations in a separate data and this is assumed to be a precise reflection of the pathogenesis of interstitial lung diseases. The evaluation values (EV) were graded from 1 to 5 for both results according to the following diagnostic significance: EV1: not useful, EV2: normal or only slight changes from normal level, EV3: moderate changes although not diagnostic, EV4: quite compatible findings for diagnosis and EV5: definitely diagnostic. The 19 patients (43%) whose EV in TBLB were either 4 or 5 were diagnosed as having sarcoidosis (3), hypersensitivity pneumonitis (1), tuberculosis (2), pneumoconiosis (6), histiocytosis X (3), pulmonary infiltration with eosinophilia syndrome (PIE) (1), collagen vascular diseases (1), panbronchiolitis (1) or lymphagiomyomatosis (1). Thirteen of them had a BAL EV 4 which consisted of rather characteristic patterns of cell differential counts: thus their diagnoses were reconfirmed. In the other 4 patients with hypersensitivity pneumonitis, tuberculosis or PIE, the diagnoses were established by the findings of BAL EV 4 although the EV of TBLB were 3 or 2. These results indicate that BAL alone hardly establishes a diagnosis but it can support the TBLB findings and increase a diagnostic ability by 10% in total. Basophilic leukocytes, mast cells and Langerhans cells in BAL were rather non-specific, but the former two frequently appeared in allergic states and the latter two were often present in fibrotic lungs. Histiocytosis X is indicated if Langerhans cells are recovered from more than a small percentage of the total cell counts.

Adolescent↗

Preliminary screening of urinary host protein biomarkers for Schistosomiasis haematobium: A proteome profiling study identifying candidate diagnostic targets in school-aged children.

Schistosomiasis is a major public health challenge and a globally neglected tropical disease. Schistosoma haematobium, the causative agent of urogenital schistosomiasis, is endemic in African countries; with school-aged children ages 7-15 years being the most vulnerable population. Current diagnostic methods rely on microscopy to identify parasite eggs in urine; which is labor-intensive, requires specialized skills, and often lacks sensitivity, especially in mild infections. To address these limitations, we explored host disease-related biomarkers as a promising avenue for advancing diagnosis and detection. We recruited 135 children ages 7-15 years from Zanzibar, a known transmission hotspot, and used data-independent acquisition (DIA) proteomics combined with machine learning to identify potential host protein biomarkers in urine samples from individuals infected with Schistosoma haematobium. Proteomic analysis identified 823 common host proteins in urine samples from the infected group. Machine learning algorithms highlighted candidate discriminative proteins; which were validated using enzyme-linked immunosorbent assays (ELISA). Machine learning emphasized SYNPO2, CD276, &#x3b1;2M, LCAT, and hnRNPM as the most discriminating biomarkers for Schistosoma haematobium infection. ELISA validation confirmed the differential expression trends of these proteins, while machine learning further validated LCAT and &#x3b1;2M, underscoring their diagnostic potential. Our study focused on host-derived proteins and identified key urinary protein biomarkers associated with Schistosoma haematobium infection, and offers new insights into host-parasite interactions and potential tools for non-invasive diagnostics. While validated in African pediatric populations from transmission hotspots, this host-protein approach inherently overcomes geographic limitations of parasite-based diagnostics; which is a critical advantage for surveillance in non-endemic regions where imported cases threaten gains toward elimination. These findings lay the groundwork for developing novel diagnostic approaches that could significantly improve the detection and surveillance of schistosomiasis, particularly in high-risk populations.

Humans↗

Methodology in diagnostic laboratory test research in clinical chemistry and clinical chemistry and laboratory medicine.

BACKGROUND: The application of epidemiologic principles to clinical diagnosis has been less developed than in other clinical areas. Knowledge of the main flaws affecting diagnostic laboratory test research is the first step for improving its quality. We assessed the methodologic aspects of articles on laboratory tests. METHODS: We included articles that estimated indexes of diagnostic accuracy (sensitivity and specificity) and were published in Clinical Chemistry or Clinical Chemistry and Laboratory Medicine in 1996, 2001, and 2002. Clinical Chemistry has paid special attention to this field of research since 1996 by publishing recommendations, checklists, and reviews. Articles were identified through electronic searches in Medline. The strategy combined the Mesh term "sensitivity and specificity" (exploded) with the text words "specificity", "false negative", and "accuracy". We examined adherence to seven methodologic criteria used in the study by Reid et al. (JAMA1995;274:645-51) of papers published in general medical journals. Three observers evaluated each article independently. RESULTS: Seventy-nine articles fulfilled the inclusion criteria. The percentage of studies that satisfied each criterion improved from 1996 to 2002. Substantial improvement was observed in reporting of the statistical uncertainty of indices of diagnostic accuracy, in criteria based on clinical information from the study population (spectrum composition), and in avoidance of workup bias. Analytical reproducibility was reported frequently (68%), whereas information about indeterminate results was rarely provided. The mean number of methodologic criteria satisfied showed a statistically significant increase over the 3 years in Clinical Chemistry but not in Clinical Chemistry and Laboratory Medicine. CONCLUSIONS: The methodologic quality of the articles on diagnostic test research published in Clinical Chemistry and Clinical Chemistry and Laboratory Medicine is comparable to the quality observed in the best general medical journals. The methodologic aspects that most need improvement are those linked to the clinical information of the populations studied. Editorial actions aimed to increase the quality of reporting of diagnostic studies could have a relevant positive effect, as shown by the improvement observed in Clinical Chemistry.

Chemistry, Clinical↗

Discordance analysis characteristics as a new method to compare the diagnostic accuracy of tests: example of complexed versus total prostate-specific antigen.

BACKGROUND: ROC curve analysis is used to compare the overall diagnostic accuracy of tests, but its application to subgroups selected by a concentration range of only one marker may show severe biases. We developed a new approach, which we have named discordance analysis characteristics (DAC). METHODS: The DAC method is based on a generalization of the McNemar test so that for a given pair of cutoff values only those patients are analyzed who are categorized differently by the two tests compared. The analyses are performed for all cutoff pairs that deliver identical sensitivities for both tests. We used data for total (tPSA) and complexed prostate-specific antigen (cPSA) from a recently published multicenter study to demonstrate the DAC method. RESULTS: The example shows that ROC analyses of subgroups can give contradictory results about the diagnostic accuracy of two markers, depending on the marker used for the selection of subgroups. The DAC method avoids artifacts attributable to questionable selection of subgroups and facilitates overall and local comparisons of the diagnostic accuracy of tests. The DAC results of the analyzed data set suggest that cPSA has higher diagnostic accuracy than does tPSA. CONCLUSIONS: The DAC method is a suitable tool for comparing the clinical usefulness of laboratory markers. The DAC method could be considered as an additional tool to ROC analysis and could replace comparative ROC analyses of diagnostic tests, especially within subgroups defined by only one of the markers.

Humans↗

Transbronchial lung biopsy. Histopathologic and morphometric assessment of diagnostic utility.

The diagnostic utility of transbronchial lung biopsy (TBB) is partly a function of its size. However, objective parameters that reflect biopsy specimen size have not yet been well-defined. We studied clinical records and histopathologic lung tissue slides of 116 patients who underwent diagnostic TBB, aiming to define the possible significance of association between seven parameters and three categories of pathologic diagnoses. Three of the seven parameters were clinical: age, sex, and chest roentgenographic infiltrates (localized vs diffuse). The remaining four parameters were histopathologic and morphometric: total number of tissue fragments, total number of alveoli (per biopsy specimen), total tissue area (alveolated plus nonalveolated), and lung total area (alveolated tissue alone). The three categories of pathologic diagnoses were as follows: infection, tumor, and nonspecific diagnoses. The nonspecific diagnoses included diagnoses of fibrosis and/or chronic inflammation. The alveoli were microscopically counted by one of us (S.D.G.). The number of biopsy fragments, the total tissue area, and the total lung area were measured in square millimeters by a computer-assisted digitizing system using specific (Bio-Quant) software (R and M Biometrics Inc). The significance of the associations between the seven parameters and the three diagnostic categories were assessed by the chi2 test for association. Overall, the following four possible associations were found to be statistically significant: (1) age--a lower percentage of patients with infection was found among patients with increasing age (p less than 0.001); (2) roentgenographic findings--a greater percentage of tumor diagnoses were found in patients with localized infiltrates (p = 0.006); (3) number of biopsy fragments--a greater percentage of patients with diagnoses of infection was identified among patients whose biopsy specimens contained the highest number of tissue fragments (p = 0.04); and (4) number of alveoli--a greater percentage of diagnosis of infection was made in patients whose biopsy specimens contained greater than or equal to 20 alveoli (p = 0.01). Our findings support the notion that the diagnostic utility of TBB is related to its size. However, this relationship between TBB size and diagnostic utility was apparent only for diagnoses of infection and not for diagnoses of tumor. We conclude that TBB specimens containing 20 or more alveoli may (1) be declared to be adequate for diagnosis, (2) in the appropriate clinical setting, they will be most likely to yield a diagnosis of infection, and (3) the number of alveoli does not appear to be associated to the diagnosis of tumor.

Biopsy↗

Diagnostic value of tests that discriminate between exudative and transudative pleural effusions. Primary Study Investigators.

STUDY OBJECTIVE: To (1) determine appropriate decision thresholds and diagnostic accuracies for pleural fluid (PF) tests that discriminate between exudative and transudative pleural effusions, and (2) evaluate the quality of the primary investigations. DESIGN: Formal meta-analysis of studies that report the diagnostic value of pleural fluid tests. SETTING: Data collected from international academic medical centers. PATIENTS: Hospitalized patients undergoing thoracentesis for pleural effusions. INTERVENTIONS: Primary investigators were requested to transmit original data from patients described in their studies. MEASUREMENTS AND RESULTS: Eight primary studies described 1,448 patients with one or more of the following tests: protein (P)-PF, P-PF/serum ratio (R), bilirubin (BILI)-R, lactate dehydrogenase (LDH)-PF, LDH-R, cholesterol (C)-PF, C-R, and albumin gradient. We found that all eight tests had similar diagnostic accuracies when evaluated by receiver operating characteristic (ROC) analysis except for BILI-R, which was less diagnostically accurate. Decision thresholds determined by ROC analysis differed from previously reported values for LDH-PF (>0.45 upper limits of normal) and C-PF (>45 mg/dL). Paired and triplet test combinations tended to have higher diagnostic accuracies compared with individual tests, but examination of the odds ratios with 95% confidence intervals did not identify a clearly superior test combination. Limitations of the primary studies presented a high likelihood of bias affecting their results. CONCLUSIONS: Several strategies exist for clinicians in utilizing PF tests to classify effusions as exudates or transudates but accurate interpretations of these test results will require better designed studies.

Albumins↗

Empiric treatments impair the diagnostic yield of BAL in HIV-positive patients.

OBJECTIVE: To investigate the influence of empiric treatments prior to fiberoptic bronchoscopy (FOB) on the diagnostic yield of BAL in HIV-positive patients with respiratory symptoms. METHOD: We studied 123 consecutive FOBs with BAL in HIV-positive patients; 101 of these patients (82%) had received previous antimicrobial treatment from 1 to 60 days. Diagnostic yield of BAL for Pneumocystis carinii, Mycobacterium tuberculosis, and bacterial pneumonia was compared between patients with and without previous empiric treatments. RESULTS: A diagnosis was obtained in 85 patients (69%), of whom 17 (20%) had multiple infections. Diagnostic yield was higher in patients without previous treatment, 91% (20/22) compared with 64% (65/101), p < 0.03. Diagnostic yield was also higher for bacterial pneumonia: seven isolations from 22 patients not receiving previous empiric treatment (32%), compared with 11 of those who had (11%; p < 0.02). The duration of empiric treatment against P carinii in patients in whom it was isolated was significantly shorter than in those in whom P carinii was not detected (3.5 +/- 1.8 days compared with 5.2 +/- 2.4 days; p = 0.003). FOB permitted a change in treatment in 62% of patients with a final diagnosis. CONCLUSION: This study demonstrates that empiric treatments prior to FOB significantly impair the diagnostic yield of BAL in detecting common pathogens in HIV-infected patients with respiratory symptoms.

AIDS-Related Opportunistic Infections↗

Diagnostic value of transbronchial needle aspiration by Wang 22-gauge cytology needle in intrathoracic lymphadenopathy.

OBJECTIVES: The aim of this study was to investigate the diagnostic value of transbronchial needle aspiration (TBNA) performed with a Wang 22-gauge cytology needle in patients with mediastinal and/or hilar adenopathy. DESIGN: Cross-sectional study. SETTING: Tertiary care training hospital. PATIENTS: TBNA procedures were performed using a flexible bronchoscope and a 22-gauge Wang needle in 60 consecutive patients (36 women and 24 men; mean age, 39 +/- 16 years [+/- SD]) who had mediastinal or hilar adenopathy identified on CT of the chest. RESULTS: Adequate lymph node sampling was obtained from 59 of 60 patients (98%). We were able to make a diagnosis in 45 of 60 patients (75%). TBNA was the only tool of diagnosis in 30 of the 60 patients (50%). Diagnoses included tuberculosis (n = 21), sarcoidosis (n = 21), carcinoma (n = 15), and lymphoma (n = 3). Adequate material was obtained from 20 of 21 patients with tuberculosis. The diagnosis made by TBNA was tuberculosis in 13 of 20 cases (65%). In 12 patients, diagnosis of tuberculosis was made cytologically; for the remaining 1 patient, mycobacterial culture was used. TBNA was the only diagnostic tool utilized in 8 of 20 patients with tuberculosis (40%). Diagnostic material was obtained from 16 of 21 patients with sarcoidosis (76%). In sarcoidosis, TBNA provided the only diagnostic specimen in 13 of 21 patients (62%). In all 15 patients with carcinoma (100%), diagnostic materials were obtained. Adequate but nondiagnostic samples were obtained from two patients with lymphoma, and one patient had lymphoma successfully diagnosed with TBNA. No complications were seen except minimal bleeding. CONCLUSION: TBNA performed with a Wang 22-gauge cytology needle is an effective and safe way of obtaining cytologic specimens from intrathoracic lymph nodes and can rapidly provide diagnosis, both in malignant and benign mediastinal diseases. Hopefully, this technique will reduce further need for more invasive surgical procedures.

Adult↗