Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Solid Phase Extraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82Linked to original sources

Determination of metabolites of pyrethroids in human urine using solid-phase extraction and gas chromatography-mass spectrometry.

The described method permits the determination of the five most important metabolites of the pyrethroids permethrin, cypermethrin, deltamethrin, lambda-cyhalothrin, fenvalerate, phenothrin and beta-cyfluthrin in human urine in one run. The major urinary metabolites of these substances are cis-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (cis-Cl2CA), trans-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (trans-Cl2CA), cis-3-(2,2-dibromovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (Br2CA), fluoro-3-phenoxybenzoic acid (F-PBA) and 3-phenoxybenzoic acid (3-PBA). After acidic hydrolysis to release the conjugated carboxylic acid metabolites, the analytes were separated from the matrix by means of solid-phase extraction using a reversed-phase column. The components of the eluate were converted to their methyl esters and extracted in hexane. Separation and quantitative analysis of the pyrethroid metabolites was carried out by capillary gas chromatography and mass selective detection. 2-Phenoxybenzoic acid served as an internal standard. The detection limits lay between 0.3 and 0.5 microg per litre urine. The relative standard deviations of the within-series imprecision were between 1% and 6%. The relative recovery rates ranged between 90% and 98%. Using this method we determined the elimination of pyrethroid metabolites in 24-h urine samples from eight pest controllers after indoor application of permethrin. The detected concentrations ranged from 1 to 70 microg g(-1) creatinine.

Air Pollutants, Occupational↗

Simultaneous measurement of urinary bisphenol A and alkylphenols by automated solid-phase extractive derivatization gas chromatography/mass spectrometry.

Bisphenol A (BPA) and alkylphenols (APs) are widely used industrial chemicals. BPA is used to manufacture polycarbonate plastic and epoxy resins; APs are used to make alkylphenol ethoxylates, common nonionic surfactants. BPA and APs can leach into the environment during industrial production and after degradation of the polycarbonate plastics and nonionic surfactants. Environmental exposure to these phenolic compounds has been associated with adverse reproductive and developmental effects in wildlife. We developed a sensitive and robust method for measuring BPA and six APs; 3-tert-butylphenol, 4-tert-butylphenol, 4-n-octylphenol, 4-tert-octylphenol, 4-n-nonylphenol, and technical-grade nonylphenol in urine. The method is based on the use of automated solid-phase extraction (SPE) coupled to isotope dilution-gas chromatography/mass spectrometry (GC/MS). During the automated SPE process, the phenols are both extracted from the urine matrix and derivatized, using pentafluorobenzyl bromide, on commercially available styrene-divinylbenzene copolymer-based SPE cartridges. After elution from the SPE column, the derivatized phenols in the SPE eluate are analyzed by GC/MS. The method, validated on spiked pooled urine samples and on urine samples from exposed persons, has limits of detection of approximately 0.1 ng in 1 mL of urine.

Alkylation↗

Determination of aldicarb, carbofuran and some of their main metabolites in groundwater by application of micellar electrokinetic capillary chromatography with diode-array detection and solid-phase extraction.

This paper describes a UV detection method for the pesticides aldicarb and carbofuran, and some of their main metabolites, aldicarb-sulfoxide, aldicarb-sulfone and 3-hydroxy-carbofuran, in ground waters. Micellar electrokinetic chromatography (MEKC) with diode-array detection was developed for their determination at 210 nm. The experimental study was performed using sodium dodecyl sulfate (SDS) at a concentration level of 140 mM, and a buffer of borax/HCl 20 mM at pH 8 which gives the best resolution with an analysis time of less than 20 min. Different instrumental parameters such as voltage (23 kV), injection time (12 s) and temperature (25 degrees C) were optimized. The detection limits were in the range 2-7.4 microg glitre(-1) by solid-phase extraction (SPE) with a subsequent evaporation step. Groundwater spiked samples were pre-concentrated off-line with graphite carbon and subsequently analyzed by MEKC with diode-array detection yielding average recoveries between 77 and 97% (n = 4) with RSD between 2-7%.

Aldicarb↗

Fully automated determination of selective retinoic acid receptor ligands in mouse plasma and tissue by reversed-phase liquid chromatography coupled on-line with solid-phase extraction.

A fully automated reversed-phase HPLC method was developed for the quantitative assay of three retinoids (Am-580, CD-2019 and CD-437) which selectively activate the retinoic acid receptors RAR alpha, RAR beta and RAR gamma, respectively. Mouse plasma, embryo and maternal tissues were prepared for injection by on-line solid-phase extraction (SPE) and valve-switching techniques. Following automatic injection, the sample was loaded on preconditioned disposable cartridges, cleaned-up and then transferred onto the analytical column to be eluted in the backflush mode, separated by gradient elution and detected by UV, while a new cartridge was concomitantly conditioned. The overall recovery was quantitative allowing for external standardization. The calibration curves were linear in all biological samples tested so far, with a correlation coefficient (r) >0.99. The intra-day precision was < or = 7.8% (n = 5-6) and the inter-day variability was < or = 9.4% (n = 3). The lower limit of detection was 2.5 ng/ml or ng/g for CD-2019 and CD-437, and 5 ng/ml for Am-580 with a S/N ratio of 5 using a sample weight of 25 microliters or mg. The method is now in routine use in our laboratory for the assessment of the pharmacokinetic profiles of these retinoids. The small sample size required, the simple sample preparation and the rapid analysis with high degree of automation make this method convenient for microanalysis of biological samples both in animal and human studies.

Animals↗

Metathesis polymerization-derived monolithic membranes for solid-phase extraction coupled with diffuse reflectance spectroscopy.

Novel monolithic disks were prepared via ring opening metathesis polymerization (ROMP) from norborn-2-ene (NBE), a crosslinker, i.e., 1,4,5,8,8a-hexahydro-1,4,4,5,8, exo, endo-dimethanonaphthalene (DMN-H6) and tris(norborn-5-ene-2-ylmethylenoxy)methylsilane, respectively, 2-propanol and toluene (25:25:41:9, all %, w/w) using RuCl2(PCy3)2(CHPh) (Cy=cyclohexyl) as initiator and triphenylphosphine (PPh3) as modulator. Disks 1-2 mm thick were prepared by polymerization in a mold, disks thinner than 1mm were prepared by impregnation of nylon or other porous filters prior to the polymerization step. These disks were evaluated for the preconcentration of iodine and selected organic solutes from dilute aqueous samples by solid-phase extraction (SPE). Quantitative measurement of the extracted solutes was achieved by diffuse-reflectance spectroscopy (DRS) directly on the surface of the disk.

Bridged Bicyclo Compounds↗

Determination of alentamol hydrobromide, a novel antipsychotic agent, in human blood plasma and urine by high-performance liquid chromatography with fluorescence detection and solid-phase extraction.

Alentamol hydrobromide, (+)-2-(dipropylamino)-2,3-dihydro-1H-phenalen-5-ol monohydrobromide, is a selective dopamine agonist currently being investigated for the treatment of schizophrenia. This paper describes a reversed-phase high-performance liquid chromatographic-based method for the quantification of alentamol in blood plasma and urine. The method utilizes solid-phase extraction with carboxylic acid-derivatized silica columns. A limit of quantitation of 0.1 ng/ml in plasma was achieved by virtue of selective extraction and fluorescence detection. Example chromatograms of plasma and urine specimens from clinical trials demonstrate the utility of the method.

Chromatography, High Pressure Liquid↗

On-line preconcentration of organic anions in capillary electrophoresis by solid-phase extraction using latex-coated monolithic stationary phases.

Quaternary ammonium functionalised polymeric latex particles were coated onto the wall of a fused-silica capillary or onto a methacrylate monolithic bed synthesised inside the capillary in order to create ion-exchange stationary phases of varying ion-exchange capacity. These capillaries were coupled in-line to a separation capillary and used for the solid-phase extraction (SPE), preconcentration and subsequent separation of organic anions by capillary electrophoresis. A transient isotachophoretic gradient was used for the elution of bound analytes from the SPE phase using two modes of separation. The first comprised a low capacity SPE column combined with a fluoride/octanesulfonate discontinuous electrolyte system in which peak compression occurred at the isotachophoretic gradient front. The compressed anions were separated electrophoretically after elution from the SPE preconcentration phase and resolution was achieved by altering the pH of the electrolyte in which the separation was performed. In the second approach, a latex-coated monolithic SPE preconcentration stationary phase was used in combination with a fluoride/perchlorate electrolyte system, which allowed capillary electrochromatographic separation to occur behind the isotachophoretic gradient front. This method permitted the removal of weakly bound anions from the SPE phase, thereby establishing the possibility of sample clean-up. The effect of the nature of the strong electrolyte forming the isotachophoretic gradient on the separation and also on the preconcentration step was investigated. Capillary electrochromatography of inorganic and organic species performed on the latex-coated monolithic methacrylate column highlighted the presence of mixed-mode interactions resulting from the incomplete coverage of latex particles onto the monolithic surface. Analyte preconcentration prior to separation resulted in compression of the analyte zone by a factor of 300. Improvement in the limit of detection of up to 10400 times could be achieved when performing the preconcentration step and the presented methods had limits of detection (S/N=3) ranging between 1.5 and 12 nM for the organic anions studied.

Anions↗

High-performance liquid chromatographic determination of ursodeoxycholic acid after solid phase extraction of blood serum and detection-oriented derivatization.

Ursodeoxycholic acid (3 alpha,7 beta-dihydroxy-5 beta-cholanoic acid, UDCA) is a therapeutically applicable bile acid widely used for the dissolution of cholesterol-rich gallstones and in the treatment of chronic liver diseases associated with cholestasis. UDCA is more hydrophilic and less toxic than another therapeutically valuable bile acid, chenodeoxycholic acid (CDCA), the 7 alpha-epimer of UDCA. Procedures for sample preparation and HPLC determination of UDCA in blood serum were developed and validated. A higher homologue of UDCA containing an additional methylene group in the side chain was synthetized and used as an internal standard (IS). Serum samples with IS were diluted with a buffer (pH=7). The bile acids and IS were captured using solid phase extraction (C18 cartridges). The carboxylic group of the analytes was derivatized using 2-bromo-2'-acetonaphthone (a detection-oriented derivatization), and reaction mixtures were analyzed (HPLC with UV 245 nm detection; a 125--4 mm column containing Lichrospher 100 C18, 5 microm; mobile phase: acetonitrile--water, 6:4 (v/v)). Following validation, this method was used for pharmacokinetic studies of UDCA in humans.

Adult↗

Detection of flunixin in equine urine using high-performance liquid chromatography with particle beam and atmospheric pressure ionization mass spectrometry after solid-phase extraction.

A normal-phase HPLC method combined with particle-beam mass spectrometry (PB-MS) was developed for the analysis of non-steroidal anti-inflammatory drugs (NSAIDs). The forty one NSAIDs analysed responded in one or more (electron impact, positive and negative chemical ionisation) modes and highly characteristic spectra were produced. A mixed-mode solid-phase extraction (SPE) method for isolating acidic NSAIDs was developed using the Bond Elut Certify II cartridge. The average recovery was 88.5%. Flunixin, extracted by SPE from urine of a mare to which the meglumine salt had been administered was positively identified by HPLC-PB-MS and HPLC-atmospheric pressure ionization (API) MS methods.

Animals↗

Determination of selected herbicides and phenols in water and soils by solid-phase extraction and high-performance liquid chromatography.

A high-performance liquid chromatography procedure or the determination of the herbicides simazine, propazine, bromacil, metoxuron, and hexazinone is elaborated. Stationary phases RP8 and RP18 and mixtures of methanol-water (2:1 and 1:1, v/v) as a mobile phase are applied for this purpose. The conditions for solid-phase extraction are established, allowing the separation of phenols and herbicides in their mixtures and the extraction of phenols (from river and coke plant water) and herbicides (from the soil samples).

Adsorption↗

Quantification of the anti-leukemia drug STI571 (Gleevec) and its metabolite (CGP 74588) in monkey plasma using a semi-automated solid phase extraction procedure and liquid chromatography-tandem mass spectrometry.

Signal Transduction Inhibitor 571 (STI571, formerly known as CGP 57148B) or Gleevec received fast track approval by the US Food and Drug Administration (FDA) for treatment of chronic myeloid leukemia (CML). STI571 (Gleevec) is a revolutionary and promising new oral therapy for CML, which functions at the molecular level with high specificity. The dramatic improvement in efficacy compared with existing treatments prompted an equally profound increase in the pace of development of Gleevec. The duration from first dose in man to completion of the New Drug Application (NDA) filing was less than 3 years. In addition, recently, FDA approved Gleevec for the treatment of gastrointestinal stromal tumor (GIST). In order to support all toxicokinetic (TK) studies with sufficient speed to meet various target dates, a semi-automated procedure using solid phase extraction (SPE) was developed and validated. A Packard Multi-Probe I and a SPE step in a 96-well plate format were utilized. A 3M Empore octyl (C(8))-standard density 96-well plate was used for plasma sample extraction. A Sciex API 3000 triple quadrupole mass spectrometer with an atmospheric pressure chemical ionization (APCI) interface operated in positive ion mode was used for detection. Lower limits of quantification of 1.00 and 2.00 ng/ml were attained for STI571 and its metabolite, CGP 74588, respectively. The method proved to be rugged and allowed the simultaneous quantification of STI571 and CGP 74588 in monkey plasma. Herein, assay development, validation, and representative concentration-time profiles obtained from TK studies are presented.

Administration, Oral↗

Simultaneous determination of GTS-21 and its metabolite in rat plasma by high-performance liquid chromatography using solid-phase extraction.

It has been suggested that GTS-21 can improve the learning deficits and inhibit the neuro-degeneration in patients with Alzheimer's disease. This paper describes a reversed-phase high-performance liquid chromatographic assay with visible detection at 405 nm for determination of GTS-21 and its metabolite, 4-hydroxy-GTS-21 in rat plasma. The method uses solid-phase extraction with a Bond Elut C18 column. A quantitation limit of 1.0 ng/ml was achieved using 0.5 ml of rat plasma. In the validation study, the coefficients of variation and the relative errors of each compound were less than 10%. Also freeze-thaw and storage stability were confirmed. This method has proved to be applicable to the pharmacokinetic study of GTS-21 in rats.

Animals↗

Solid-phase extraction for the decontamination of alkali metal, alkaline Earth metal, and ammonium salts from heavy metal ions.

Salicylaldoxime-immobilized silica gel was characterized and used as a potential sorbent for heavy metal ions, viz. Cu(II), Ni(II), Co(II), and Zn(II). The experimental conditions were optimized both in batch and column processes to achieve the maximum efficiency. Kinetic and thermodynamic parameters as well as isotherm constants were evaluated to test the feasibility of the process. The role of various metal ions and different anions were tested in order to monitor the process in case of real samples. The alkali metal, alkaline earth metal, and ammonium salts do not have any effect on the said process. This differential behavior can be effectively used for the decontamination of alkali metal, alkaline earth metal, and ammonium salts from Cu(II), Ni(II), Co(II), and Zn(II) ions via solid phase extraction following AAS measurement. The purification of the salts was confirmed by voltammetric experiment.

Journal Article↗

Improved rapid identification of mycobacteria by combining solid-phase extraction with high-performance liquid chromatography analysis of BACTEC cultures.

Identification of mycobacteria from BACTEC 12B cultures is achieved in 7 to 21 days by reverse-phase high-performance liquid chromatography (HPLC) using a UV spectrophotometer to detect nonpolar p-bromophenylacyl mycolic acid derivatives. However, cultures grown in BACTEC and other liquid media seldom contain sufficient mycolic acids to permit reliable identification under usual HPLC assay conditions, so the sample size must be increased. Unfortunately, samples prepared from cultures in liquid media such as BACTEC cultures also contain large amounts of extraneous polar and strongly nonpolar contaminants that interfere with the analysis and hasten deterioration of the HPLC column. The contaminants were removed from 10 samples simultaneously by solid-phase extraction (SPE), i.e., by passing the crude suspension containing the mycolic acid derivatives into disposable 500-mg tC18 SPE columns in place of the usual final filtration step used to prepare specimens for HPLC. Fifteen milliliters of 20% (vol/vol) dichloromethane in methanol was passed through the columns (< 3 ml/min) to wash through the undesired contaminants and bind the mycolic acid derivatives. The mycolates were quantitatively eluted in 3 ml of dichloromethane for analysis by HPLC. Treating a panel of 31 strains of frequently isolated mycobacteria by SPE reduced the content of contaminants by 89.3 to 99.9% without altering the chromatographic patterns compared with the same strains grown on conventional solid media and processed without SPE. Peak heights of mycolates prepared from BACTEC cultures were increased from < or = 6 to > or = 25 absorbance milliunits with SPE, sufficient for reliable interpretation by visual inspection of chromatograms obtained with a UV detector. Also, removal of the contaminants improved column longevity.

Chromatography, High Pressure Liquid↗

Development of solid-phase extraction method and its application for determination of hydrochlorothiazide in human plasma using HPLC.

A high-performance liquid chromatographic method was developed, validated and applied for the determination of hydrochlorothiazide in human plasma. The effects of mobile phase composition, buffer concentration, mobile phase pH and concentration of organic modifiers on retention of hydrochlorothiazide and internal standard were investigated. The method involves solid-phase extraction on RP-select B cartridges followed by isocratic reversed-phase chromatography on a Hibar Lichrospher 100 RP-8 column with UV detection at 230 nm. The recovery, selectivity, linearity, precision and accuracy of the method were evaluated from spiked human plasma samples. Limit of quantification was 10 ng mL(-1). The method has been implemented to monitor hydrochlorothiazide levels in patient samples.

Chromatography, High Pressure Liquid↗

Simultaneous determination of degradation products of nonylphenol polyethoxylates and their halogenated derivatives by solid-phase extraction and gas chromatography-tandem mass spectrometry after trimethylsilylation.

An efficient method for the simultaneous determination of the degradation products of nonylphenol polyethoxylates (NPnEOs, n = number of ethoxy units), i.e., nonylphenol (NP), NPnEOs (n = 1-3), nonylphenoxy carboxylic acids (NPnECs, n = 1-2, number of ethoxy units plus an acetate) and their halogenated derivatives (XNP, XNP1EO and XNP1EC; X = Br or Cl), in water samples were developed. After trimethylsilylation with N,O-bis(trimethysilyl)acetamide, all the analytes were determined by gas chromatography-tandem mass spectrometry (GC-MS-MS) with electron ionization (EI). The ion peaks of [M - 85]+ of the derivatives were selected as precursor ions and their product ions showing the highest intensities were used for the quantitative analysis. The instrumental detection limits were in the range from 2.1 to 11 pg. The recoveries of the analytes from the water samples were optimized by using solid-phase extraction (SPE). The deuterated reagents of octylphenol, octylphenol monoethoxylate and octylphenoxyacetic acid were used as the surrogates. The method detection limits (500 ml water sample) using C18 SPE were from 2.5 to 18 ng/l. The recoveries from spiked pure water and the environmental water samples were greater than 78%. The method was successfully applied to environmental samples. Remarkably, the concentrations of the halogenated compounds (CINP, CINP1EO and BrNP1EO) were detected at the hundreds of ng/l levels in the Neya river.

Gas Chromatography-Mass Spectrometry↗

A solid phase extraction reversed-phase HPLC method for the simultaneous determination of methoprene, permethrin and selected metabolites in rat plasma and urine.

A method was validated and applied for the analysis of the insect growth regulator methoprene [Isopropyl (2E,4E)-11-methoxy-3,7,11-trimethyldodeca-2,4-dienoate], its metabolite methoprene acid, the insecticide permethrin [3-(2,2-dichloro-ethenyl)-2,2-dimethylcyclopropanecarboxylic acid(3-phenoxyphenyl)methylester], and two of its metabolites, m-phenoxybenzyl alcohol and m-phenoxybenzoic acid, in rat plasma and urine using solid-phase extraction and reversed-phase high performance liquid chromatography. The analytes were separated using gradient of 55-100% acetonitrile in water (pH 4.0) at a flow rate ranging between 0.6 and 1.0 mL/min over a period of 20 min, and UV detection at 210 and 254 nm. The retention times ranged from 7.3 to 18.4 min. The limits of detection ranged between 50 and 100 ng/ml, while limits of quantitation were 100-150 ng/mL. Average percentage recovery of five spiked plasma samples was 83.6 +/- 3.9, 80.1 +/- 5.4, 82.1 +/- 4.4, 83.7 +/- 3.9 and 83.1 +/- 4.7, and from urine 79.3 +/- 4.3, 82.0 +/- 5.4, 80.7 +/- 4.2, 78.9 +/- 5.7 and 83.9 +/- 4.5 for methoprene, methoprene acid, permethrin, m-phenoxybenzyl alcohol and m-phenoxybenzoic acid, respectively. The method was linear and reproducible over the range of 100-1000 ng/mL. This method was applied to analyze the above chemicals and metabolites following their combined administration in rats.

Animals↗

Liquid chromatographic determination of ampicillin in bovine and dog plasma by using a tandem solid-phase extraction method.

The determination of ampicillin in plasma and serum by reversed-phase high-performance liquid chromatography with UV detection suffers from poor selectivity and sensitivity. Currently, the most common approach to overcoming these problems consists of improving the compound's detectability via pre- or postcolumn derivatization. In the method that we describe, however, enhanced selectivity is afforded by sample purification by a tandem solid-phase extraction method (ion-exchange and reversed-phase). This approach permits detection at wavelengths of as low as 210 nm, which results in enhanced sensitivity (detection limit, 0.01 microgram/ml). A second factor that affects selectivity is the addition to the chromatographic eluent of a crown ether to optimize the separation between ampicillin and polar endogenous plasma constituents. This combination of improved sample pretreatment and a more selective chromatographic system in conjunction with internal standardization forms the basis of a new assay for the quantitation of ampicillin in plasma. The overall recovery of ampicillin was 76.4% +/- 4.9% (n = 24), and the within-run and between-run coefficients of variation ranged from 1.6 to 7.2%. The method was applied to pharmacokinetic studies in cows and dogs after intramuscular or oral administration of the drug.

Ampicillin↗