Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PATENTS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82Linked to original sources

Combined aortic valve replacement and closure of patent ductus arteriosus in the elderly.

Two cases of patent ductus arteriosus (PDA) and aortic stenosis are presented. Both were diagnosed at routine cardiac catheterization and significant aortic gradient was concomitantly encountered. The first patient had subacute bacterial endocarditis due to B. cereus infection. Eventually it was proven to be localized on the PDA on the pulmonary artery side. Both patients underwent closure of PDA through endopulmonary closure and aortic valve replacement. Postoperative courses were uneventful. These cases demonstrated the technically easy closure of the PDA in the elderly. The literature has documented only six cases including our two cases.

Age Factors↗

Surgical closure of the patent ductus arteriosus with an intravascular prosthesis: clinical experience.

The authors developed a new prosthesis for patent ductus arteriosus (PDA) closure, using a delivery device inserted through the main pulmonary artery (MPA) avoiding ductal dissection and use of cardiopulmonary bypass. The prosthesis was inserted in 19 consecutive patients between 1985 and 1992. They have been followed for a mean of 4.8 years (minimum 30 days, maximum 7.5 years). There were 14 women (72%) and the average age was 11 years (16 months to 38 years). All patients presented with pulmonary hypertension (4 severe, 5 moderate, and 10 mild). Simultaneous surgical procedures for congenital heart disease were performed in two cases. One patient had a diffuse calcified PDA. The average diameter of the inserted prosthesis was 7.5 mm (3.5 to 12.5 mm). Neither hemorrhage nor prosthesis dislocation/embolization occurred during the implantation or in the postoperative period. In a newborn (30 days) with severe cardiomegaly and thin MPA, we decided to ligate the ductus. Chronic cor pulmonale contributed to death in one patient 3.7 years after operation. The remaining patients recovered well, without clinical evidence of residual shunt. Therefore, we recommend the use of this new prosthesis for PDA closure in cases of large ductus or ductus complicated with calcification, pulmonary hypertension, and when associated open heart surgery is required.

Adolescent↗

Application of pusher in mini-invasive patent ductus arteriosus ligation.

The possibility of a residual shunt is a major drawback to current minimally invasive procedures for the treatment of patent ductus arteriosus (PDA). From April 1997 to October 1999, 30 patients (10 males, 20 females) underwent PDA ligation by a modified technique that uses a pusher for securing the ligate of PDA via posterolateral minithoracotomy at our hospital. No complication or mortality occurred. Postoperative echocardiography also revealed no residual shunt. In this article, we introduce this simple, safe procedure for PDA ligation.

Child, Preschool↗

Minimally invasive surgical closure of patent ductus arteriosus in premature infants: a novel approach.

Recent advancement of minimally invasive cardiac surgical procedures have prompted the use of minimal incisions to perform operations on patients with congenital heart defects. In this report, we describe a new technique for closure of a patent ductus arteriosus, using an anterior extrapleural approach. We present our technique and results in five low-weight infants. This approach is safe and effective, shortens hospital stay, and is less invasive than classical approaches.

Aorta, Thoracic↗

Fatal haemorrhagic gastritis associated with oral sulindac treatment for patent ductus arteriosus.

We report the first case in a preterm infant given oral sulindac for treatment of symptomatic patent ductus arteriosus who subsequently developed severe acute haemorrhagic gastritis leading to disseminated intravascular coagulation, massive pulmonary haemorrhage and death. The postmortem examination suggested that the mechanism was likely a direct irritant insult causing ischaemia on the gastric mucosa. Although sulindac is supposed to be a renal-sparing non-steroidal anti-inflammatory prodrug associated with minimal renal and gastrointestinal adverse effects, clinicians should be alerted to this potential life-threatening complication in preterm infants. Until the question of safety could be adequately addressed, the use of sulindac for ductal closure should remain experimental.

Cyclooxygenase Inhibitors↗

Spontaneous intestinal perforation after oral ibuprofen treatment of patent ductus arteriosus in two very-low-birthweight infants.

AIM: To discuss intestinal side effects of ibuprofen in the treatment of patent ductus arteriosus, after having observed two cases of spontaneous intestinal perforation following ibuprofen treatment. METHODS: Clinical and laboratory records of two preterm infants, who developed intestinal perforation after ibuprofen administration, were evaluated. RESULTS: Gestational ages of infants were 29 wk (male) and 30 wk (female). Both infants developed intestinal perforations without signs of necrotizing enterocolitis. The perforations cured with Penrose drainage alone. CONCLUSION: Although ibuprofen is a reasonable treatment alternative to indomethacin, randomized controlled trials, which address potential adverse effects including spontaneous intestinal perforation, are needed.

Administration, Oral↗

Iatrogenic cardiovocal syndrome caused by transcatheter coil closure of patent ductus arteriosus.

UNLABELLED: Two infants developed hoarseness unexpectedly the day after transcatheter coil closure of a slender patent ductus arteriosus (PDA). The pathogenesis of this complication appears to be similar to that of the classic cardiovocal syndrome. During the intervention, the inappropriately implanted coil might have distorted the slender PDA, thereby causing angulation of the pliable PDA itself and precipitating impingement on the left recurrent laryngeal nerve. Fortunately, both infants recovered spontaneously from the hoarseness within several weeks. At present, the definite underlying neuropathology of this complication is unknown as we have not yet confirmed recovery of the left vocal cord movement by follow-up fibreoptic bronchoscopy. CONCLUSION: Iatrogenic cardiovocal syndrome could occur in infants after transcatheter coil closure of a slender PDA, using the currently popular 0.038-inch coil. A coil with a smaller diameter might prevent the occurrence of this syndrome.

Ductus Arteriosus, Patent↗

A wire loop technique for ligation of patent ductus arteriosus.

A novel, yet simple and inexpensive, technique is described for the safe passage of suture material for closure of patent ductus arteriosus in small animals. The risk of haemorrhage is reduced by minimising dissection with forceps and by preventing inadvertent grasping of perivascular connective tissue.

Animals↗

Treatment of patent ductus arteriosus by placement of two intravascular embolisation coils in a puppy.

A 14-week-old border collie with a history of exercise intolerance was confirmed to have a patent ductus arteriosus (PDA) from colour flow Doppler echocardiography. Under general anaesthesia, angiography was performed to gauge accurately the width of the ductus, and then two intravascular embolisation coils were introduced into the ductus via percutaneous catheterisation of the femoral vein. The coils were both 8 mm in diameter, each with four loops. This led to an immediate disappearance of the murmur. Some slight residual flow was detected at the time of the procedure by angiography, but by 10 days postoperatively there was no PDA flow detectable. The time taken to complete the procedure was 55 minutes, with a total fluoroscopy time of 15 minutes. Placement of intravascular embolisation coils represents a viable alternative to traditional surgical methods of ductus closure.

Animals↗

Closure of large patent ductus arteriosus with a self-expanding duct occluder in two dogs.

Of the different catheterisation methods described for closure of patent ductus arteriosus (PDA), coil embolisation is most commonly used in dogs. However, for a PDA larger than 4 to 5 mm in diameter, coil implantation is difficult. For these cases, the Amplatzer duct occluder (ADO) offers an alternative method. This report describes the successful implantation of an ADO in two dogs with large PDAs of approximately 6 mm diameter. The self-expandible device attached to an implantation wire was advanced through a long sheath antegrade to the femoral vein through the right heart and pulmonary artery to the duct and delivered into the PDA. Thereafter the device was released by unscrewing it from the delivery cable. The large PDA in both dogs was totally occluded by these means without any residual shunt. Thus, the ADO is a controlled release implant that also allows occlusion of a large PDA. Its high costs limit its general use in veterinary medicine at the present time.

Angiography↗

Review of left-to-right shunting patent ductus arteriosus and short term outcome in 98 dogs.

The case records of 98 dogs with a left-to-right shunting patent ductus arteriosus (PDA) were reviewed. There were 35 breeds represented, with a female to male ratio of 3:1. Forty per cent of the dogs were older than one year at initial presentation and 31 per cent had clinical signs attributable to PDA. A left heart base continuous murmur of grade IV/VI or higher was noted in 90 per cent of the dogs. On electrocardiography, the most common abnormalities were tall R waves (63 per cent) and deep QII waves (62 per cent). The radiographic triad of dilation of the descending aorta with enlargement of the main pulmonary artery segment and left atrium, typical of PDA, was noted in only 26 per cent of cases. Two-dimensional (2D) and M-mode echocardiography detected left atrial enlargement (35 per cent) and an increased left ventricular diameter in diastole (82 per cent) and systole (84 per cent) as the most common abnormalities. Doppler echocardiography demonstrated increased aortic outflow velocities in 66 per cent of cases. The overall short-term successful outcome in this study was 95 per cent. There was no significant difference between surgical ductal ligation using a standard technique or the Jackson-Henderson technique in terms of survival, occurrence of haemorrhage or residual shunting. The number of interventional procedures used in this study was too low for statistical comparison, but there appeared to be a trend towards a higher rate of residual shunting and a lower fatality rate using a coil occlusion technique.

Animals↗

Long-term follow-up of dogs with patent ductus arteriosus.

Postocclusion survival data from dogs with left-to-right shunting patent ductus arteriosus (PDA) was available from 80 dogs, diagnosed from 1990 to 2000. Of these, 37 had undergone a procedure to close the ductus and were re-evaluated at the time of this study; clinical data from the follow-up examination was compared with that from the original examination. Radiographically, the right ventricle remained apparently enlarged, and the aortic bulge associated with dilation of the descending aorta did not disappear after closure. On M-mode echocardiography, left ventricular chamber diameter in diastole and systole and left ventricular posterior wall in systole decreased significantly. Mitral endocardiosis was a common feature. Residual flow was evident in 46 per cent of the animals. Late closure occurred in 8 per cent of the dogs, and trivial recanalisation in 19 per cent. The maximum survival time postclosure was 168 months and, after non-occlusion, 114 months, suggesting that dogs with PDA follow an unpredictable course. However, there was a significant difference in survival times between the corrected and non-corrected group.

Animals↗

Right-to-left shunting patent ductus arteriosus with pulmonary hypertension in a cat.

A 16-month-old, neutered female domestic shorthaired cat had tachypnoea, inappetence and a heart murmur, which had been first detected at eight weeks old. Diagnosis of reverse shunting patent ductus arteriosus and pulmonary hypertension was based on a detailed two-dimensional and Doppler echocardiographic examination. This report documents the clinical and imaging findings in this rare feline condition.

Animals↗

Etiology of patent ductus arteriosus in dogs.

Patent ductus arteriosus (PDA) is the most common congenital heart disease in dogs and usually causes heart failure and death unless corrected at a young age. Previous histologic studies in a line of dogs derived from Miniature Poodles with hereditary PDA identified varying degrees of hypoplasia and asymmetry of ductus-specific smooth muscle and the presence of aortalike elastic tissue in the ductus wall sufficient to cause patency. To determine if similar structural abnormalities cause PDA in other dogs, serial-section, 3-dimensional histology of ductal architecture was studied in 8 non-Poodle purebred dogs with PDA with no immediate family history of PDA. Morphologic abnormalities were observed in 7 of 8 dogs with PDA and essentially were the same as those in dogs known to have a hereditary form of PDA. These findings suggest that apparently sporadic PDA in these breeds is caused by a genetic defect in the structure of the ductus arteriosus that is similar or identical to that in the Poodle. The relatives of dogs with PDA, particularly parents, offspring, and siblings, should be screened for evidence of PDA. Dogs with PDA should not be used for breeding, regardless of breed.

Animals↗

Cerebral blood flow velocity during occlusive manipulation of patent ductus arteriosus in children.

Patent ductus arteriosus (PDA) with left-to-right shunting modifies the Doppler flow pattern of the intracranial circulation. The ability of increases in cerebral blood flow velocity (CBFV) to predict shunt resolution during PDA occlusion was evaluated. A 2 MHz transcranial Doppler (TCD) monitored diastolic and mean CBFV, plus the systolic/mean CBFV ratio in the middle cerebral artery from before (baseline) to immediately after PDA occlusion. Shunt resolution was verified by echocardiography and/or angiography. A minimum of 40% increase in diastolic-CBFV from baseline was considered successful resolution. Patients were age-stratified into group I (< 15 months; n = 23) and group II (> 15 months; n = 10). Thirty-three children were studied (age, 0.1 to 109 months) during surgical (n = 22) or coil occlusions (n = 11). Transcranial Doppler successfully identified shunt resolution in 78% of cases in group I, as compared to 0% in group II (p < 0.01). Identification rate decreased from 79% in cases of minimum ductal diameter of 3 mm (n = 19) to 21% in smaller ductuses (n = 14) (p < 0.01). Body weight and left-atrium size (p = 0.004) in group I and PDA diameter in group II (p = 0.02), were the only preoperative ductal parameters associated with diastolic-CBFV changes after ductus occlusion. Transcranial Doppler detects shunt resolution in infants with moderate to large PDAs.

Blood Flow Velocity↗

Does patent ductus arteriosus affect feed tolerance in preterm neonates?

Patent ductus arteriosus (PDA), especially PDA with sepsis, has been reported as a risk factor for feed intolerance in preterm neonates. In this study, the start to full feeds interval was found to be longest in preterm neonates (<or=28 weeks' gestation) with sepsis, followed by that in preterm neonates with sepsis and PDA, and in those with PDA alone.

Age Factors↗

Conservative treatment for patent ductus arteriosus in the preterm.

BACKGROUND: A patent ductus arteriosus (PDA) is common among preterms, and prophylactic medical treatment has been advocated as the first-line approach. Conservative treatment may result in similar outcome, but without exposure to the harmful side effects of medication. A retrospective analysis revealed a ductal closure rate of 94% after conservative treatment with adjustment of ventilation (lowering the inspiratory time and increasing positive end expiratory pressure) and fluid restriction. OBJECTIVE: To study prospectively over one year the rate of PDA closure, and morbidity and mortality following conservative treatment. METHOD: Prospective study (1 January 2005 - 31 December 2005) including 30 newborns <or=30 weeks' gestation, all of whom were being ventilated and required surfactant. Echocardiography was performed 48-72 h after birth. Clinically important PDA was conservatively treated as described above. The percentage of children with PDA, ductal ligation and major complications was determined. RESULTS: Ten neonates (33%) developed a clinical important PDA. Following conservative treatment the duct closed in all neonates (100%), and none required ductal ligation or medical treatment. The rates of major complications were no higher than those reported by the Vermont Oxford Network and in the literature. CONCLUSION: The managed care plan resulted in an overall ductal closure rate of 100%. These results suggest that conservative treatment of PDA is a worthy alternative to prophylactic medical treatment.

Anti-Inflammatory Agents, Non-Steroidal↗