Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Flow Injection Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82Linked to original sources

Kinetic mechanism of protease inhibition by alpha1-antitrypsin.

The native form of serine protease inhibitor (serpin) is kinetically trapped in a metastable state. Metastability in these proteins is critical to inhibit target protease by forming a stable covalent complex. Despite recent determination of the crystal structures of a Michaelis protease-serpin complex as well as a stable covalent complex, details on the kinetic mechanism remain unsolved. In this report, we examined the reaction mechanism of alpha1-antitrypsin toward elastase by a combination of stopped-flow experiments via fluorescence resonance energy transfer and rapid-quench studies. The results suggest a non-covalent complex intermediate other than Michaelis complex as an intermediate before the cleavage of P1-P1' scissile bond, whose formation is the rate-determining step of the overall reaction. This rate-limiting step represents rearrangement of the reactive site loop, and is regulated by a salt bridge between E354 and R196. The ionic interaction is unique to alpha1-antitrypsin, which suggests that protease inhibition mechanisms are varied among serpins.

Amino Acid Substitution↗

Peroxynitrite efficiently mediates the interconversion of redox intermediates of myeloperoxidase.

Nitric oxide-derived oxidants (e.g., peroxynitrite) are believed to participate in antimicrobial activities as part of normal host defenses but also in oxidative tissue injury in inflammatory disorders. A similar role is ascribed to the heme enzyme myeloperoxidase (MPO), the most abundant protein of polymorphonuclear leukocytes, which are the terminal phagocytosing effector cells of the innate immune system. Concomitant production of peroxynitrite and release of millimolar MPO are characteristic events during phagocytosis. In order to understand the mode of interaction between MPO and peroxynitrite, we have performed a comprehensive stopped-flow investigation of the reaction between all physiological relevant redox intermediates of MPO and peroxynitrite. Both iron(III) MPO and iron(II) MPO are rapidly converted to compound II by peroxynitrite in monophasic reactions with calculated rate constants of (6.8+/-0.1) x 10(6) M(-1)s(-1) and (1.3+/-0.2) x 10(6) M(-1)s(-1), respectively (pH 7.0 and 25 degrees C). Besides these one- and two-electron reduction reactions of peroxynitrite, which produce nitrogen dioxide and nitrite, a one-electron oxidation to the oxoperoxonitrogen radical must occur in the fast monophasic transition of compound I to compound II mediated by peroxynitrite at pH 7.0 [(7.6+/-0.1) x 10(6) M(-1)s(-1)]. In addition, peroxynitrite induced a steady-state transition from compound III to compound II with a rate of (1.0+/-0.3) x 10(4) M(-1)s(-1). Thus, the interconversion among the various oxidation states of MPO that is prompted by peroxynitrite is remarkable. Reaction mechanisms are proposed and the physiological relevance is discussed.

Flow Injection Analysis↗

Characterization of natural chitosan membranes from the carapace of the soldier crab Mictyris brevidactylus and its application to immobilize glucose oxidase in amperometric flow-injection biosensing system.

This study investigated characteristics of a chitosan membrane from the carapace of the soldier crab Mictyris brevidactylus intended to construct an amperometric biosensor. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were used in this study to characterize these chitosan membranes intended for constructing enzymatic biosensors. Chitosan membranes suffering various durations (>10 min) of deacetylation had small charge-transfer resistances (<7.88 kohms) but large double-layer capacitances (>0.55 microF). They were found in EIS where both the solution resistance and Warburg impedance upon electrode interface were almost independent of the durations and degree of deacetylation. The degree of deacetylation and the thickness of chitosan membranes were also determined. Membrane thickness was slightly dependent with the duration but degree of deacetylation was slightly dependent on the duration. Chitosan membranes with various thicknesses suffered various durations of deacetylation, but this did not influence their electrochemical characteristics. The chitinous membrane was covalently immobilized with glucose oxidase (EC 1.3.4.3) and then attached onto the platinum electrode of a homemade amperometric flow cell. Sensor signal was linearly related to glucose concentration (r=0.999 for glucose up to 1.0 mM). The system was sensitive (S/N>5 for 10 microM glucose) and reproducible (CV<1.3% for 50 microM glucose, n=5).

Acetylation↗

Real-time assay of immobilized tannase with a stopped-flow conductometric device.

A stopped-flow manifold was developed to assay and characterize immobilized tannase (EC 3.1.1.20). The immobilized enzyme reactor was inserted within the tube-type electrode pair (cell constant=103.2 cm(-1)) for a real-time conductometric measurement. Tris buffer (2 mM, pH=7.0) was used as the carrier for sensitivity improvement. The activities and kinetic parameters (Km values) for propyl gallate, methyl gallate and tannic acid were investigated.

Carboxylic Ester Hydrolases↗

Electrochemical modulation of antigen-antibody binding.

The label-free amperometric detection of a rabbit IgG antigen by an anti-rabbit IgG antibody is achieved by observing the electrochemistry at a glassy carbon electrode modified with antibody entrapped in an electrodeposited polypyrrole membrane. In a flow injection apparatus the electrode is pulsed between -0.2 and +0.4 V versus Ag/AgCl. The pulsing of the electrode switches the polypyrrole membrane between the oxidised and reduced states. When antigen is injected into the flow stream a change in current is observed at the electrode despite the antigen or antibody being redox inactive at the potentials employed. It is proposed that this current is due to a change in the flux of ions into and out of the polypyrrole matrix during a pulse when the poly-anionic antigen is present. The immunoreaction was reversible because the 200 ms pulse at each potential was too short to allow secondary bonding forces (hydrogen bonding and hydrophobic forces) which are responsible for the strength of the antibody-antigen complex to be established. The consequence of the reversibility of the antigen-antibody binding is a low apparent affinity constant but an easily regenerated recognition interface.

Animals↗

Respiratory response of cell-based sensors to toxicants measured by using pseudo-random signals.

Cell-based sensors using such as Pseudomonas putida and Bacillus subtilis were applied to examine the toxicity of chemicals. Both toxicant and substrate solutions were introduced into the sensor system according to M-series and anti-symmetric M-series pseudo-random binary signals, Xn (n=15, minimal pulse width 4 min, period 60 min) and Yn (n=30, minimal pulse width 4 min, period 120 min). Toxicants such as Ag+, formaldehyde, azide, and hypo-chlorite were used to demonstrate the proposed method. The individual responses of substrate and toxicant were obtained at a time by calculating the cross-correlation function between the input and the output signals. Effects of toxicant on the response of substrate and the response of toxicant itself can be observed at a time, so that the method appears to be useful in studying the behavior of microorganisms in the presence of toxicants.

Algorithms↗

One-step screen-printed electrode modified in its bulk with HRP based on direct electron transfer for hydrogen peroxide detection in flow injection mode.

The preparation and performances of screen-printed carbon electrodes modified in their bulk with HRP (HRP-SPCE) is reported. The resulting modified HRP-SPCE was prepared in a one-step procedure, and then was optimised as an amperometric biosensor operating at [0-100] mV versus Ag/AgCl in flow injection mode for hydrogen peroxide. The amperometric response was due to direct electron transfer (DET) between HRP and SPCE surface. Factors such as chemical modification of the enzyme or the nature and rate of the binder were investigated regards to their influence on the sensitivity, linear range and operational stability. The best performing HRP-SPCE in terms of sensitivity and operational stability was obtained when graphite powder was modified with HRP previously oxidised by periodate ion (IO(4)(-)).

Adsorption↗

Sub-second adsorptive fast Fourier transform coulometric technique as a novel method for the determination of nanomolar concentrations of sodium valproate in its pharmaceutical preparation in flowing solution systems.

In this work, a novel electrochemical technique has been developed for determination of nanomolar concentration of sodium valproate in flow-injection systems. The detection was done by adsorptive fast Fourier transform coulometric (AFFTC), in which the potential waveform consists of potential steps for cleaning, accumulation, and a potential ramp that was continuously applied on an Au disk microelectrode. Moreover, a special computer program is introduced based on numerical method, for calculation of the analyte signal (which is the partial and total charge exchanges at the electrode surface) and noise reduction. The optimum parameters were: pH value of 2.0, scan rate value of 40 Vs(-1), accumulation potential of 200 mV and accumulation time of 0.3 s. Detection limit of the method for sodium valproate was 9.0x10(-9) M. The relative standard deviation of the method at 1.3x10(-7) M was 2.0% for 10 runs.

Electrochemistry↗

Layer-by-layer hydroxymethyl ferrocene modified sensor for one-step flow/stop-flow injection amperometric immunoassay of alpha-fetoprotein.

A rapid one-step flow/stop-flow injection amperometric immunoassay for alpha-fetoprotein (AFP) using a novel home-produced electrochemical sensor was proposed. The sensor was prepared using layer-by-layer adsorption of positively charged poly(allylamine) (PAA) and negatively charged hydroxymethyl ferrocene on a screen-printed electrode (SPE). The electrochemistry of the immobilized ferrocene moieties showed a surface-controlled electrode process. Based on an electrochemical enzyme-linked immunoassay with the immobilized ferrocene moieties as an electron transfer mediator between the electrode and the horseradish peroxidase (HRP)-labeled anti-AFP antibody, a calibration curve with two linear ranges from 5 to 20 and 20 to 150 ng ml-1 and a detection limit of 2 ng ml-1 for AFP determination was obtained under the optimized conditions of 0.891 ml min-1 flow rate, 20 microl injection volume and +25 mV applied potential. The sensor showed good repeatability and reproducibility and retained more than 95% of its original signal after 15 days of storage. The proposed method eliminated the need for washing and addition of any substrate or mediator. The complete assay could be handled in less than 25 min with a one-step injection of a 40 microl sample solution. The proposed method would be valuable for the diagnosis and monitoring of carcinoma and its metastasis.

Biosensing Techniques↗

Simple and sensitive bacterial quantification by a flow-based kinetic exclusion fluorescence immunoassay.

A flow-based immunoassay system utilizing secondary-antibody coated microbeads and Cy5-secondary antibody for signal production was successfully developed to quantitate target bacteria with a kinetic exclusion assay (KinExA 3000 Instrument). It directly measured the concentration of unliganded antibody separated from the equilibrated mixture of antibody and bacteria through a 0.2 microm polyethersulfone membrane, enabling it to quantify the concentration of bacteria. The novel method demonstrated the qualities of rapidness, sensitivity, high accuracy and reproducibility, and ease to perform. Detection of Pseudomonas aeruginosa and Staphylococcus aureus was accomplished with low detection limits of 4.10 x 10(6) and 5.20 x l0(4)cells/mL, respectively, with an assay time of less than 15 min. The working ranges for quantification were 4.10 x l0(6) to 1.64 x l0(10)cells/mL for P. aeruginosa, and 5.20 x l0(4) to 1.04 x l0(9)cells/mL for S. aureus. It yielded an assay with at least 10-fold greater sensitivity than ELISA and could correctly assess the concentration of predominant bacterium spiked in the mixture of P. aeruginosa and S. aureus. With this reliable platform, the average amount of antibody bound by one cell in the maximum capability could be further provided: (1.6-2.5) x l0(5) antibodies for one P. aeruginosa cell and (2.2-2.7) x l0(8) antibodies for one S. aureus cell. The KinExA system is flexible to determine different kinds of bacteria conveniently by using anti-mouse IgG as the same immobilizing agent. However, a higher specificity of the antibodies to the target bacteria will be required for the use of this system with higher detection sensitivity.

Biosensing Techniques↗

Ultrasensitive assay of azithromycin in medicine and bio-fluids based on its enhanced luminol-H(2)O(2) chemiluminescence reaction using flow injection technique.

A simple flow injection chemiluminescence method with synergistic enhancement has been investigated for the rapid and sensitive determination of azithromycin. The synergistic action was significant in the chemiluminescence system of luminol-hydrogen peroxide with azithromycin as an enhancer. The enhanced chemiluminescence intensity was linear with the concentration of azithromycin over the range from 0.1 pg x mL(-1) to 1.0 ng x mL(-1) (r(2=)0.9988) with a detection limit (3sigma) of 0.04 pg x mL(-1). At a flow rate of 2.0 mL x min(-1), a complete analytical process could be performed within 0.5 min, including sampling and washing, with a relative standard deviation of less than 3.0%. The proposed method was applied successfully in the assay of azithromycin in pharmaceutical preparations, human urine and serum without any pre-treatment procedure.

Anti-Bacterial Agents↗

Dynamic pH junction technique for on-line preconcentration of peptides in capillary electrophoresis.

A method based on the presence of a dynamic pH junction within the capillary to induce band narrowing for enhanced detection sensitivity for some peptides is presented. This technique is predicated on a sharp reduction in an analyte's migration velocity following a reversal of its electrophoretic direction from the acidic sample zone to the basic BGS zone. Larger-than-usual injection volumes of samples in relatively high-conductivity matrices were enabled, without degrading peak shape, resolution and efficiency. The size of the original sample plug was reduced by as much as 38-fold, and improvement in detector response in terms of peak height by as much as 124-fold was obtained. The effects of pH and concentration of the sample matrix, and the length of sample injection on the efficiency of the technique are discussed.

Angiotensin I↗

Combining restricted access material (RAM) and turbulent flow for the rapid on-line extraction of the cyclooxygenase-2 inhibitor rofecoxib in plasma samples.

Restricted access material (RAM) has been used in the packing of a solid-phase extraction (SPE) column for on-line extractions under turbulent flow conditions. The bio-compatible RAM material works by the principle of size exclusion in addition to conventional reversed-phase chromatography, thereby allowing the extraction and preconcentration of small analyte molecules from biological samples such as plasma. Using small column dimensions (0.76 mm x 50 mm) and a consequently high linear velocity, turbulent flow was achieved during online sample extractions. The improved mass-transfer rate characteristic of turbulent flow allows fast sample cleanup without decreased extraction efficiency. The novel use of the RAM column, connected upstream to a C18 monolithic column, allowed the direct injection, extraction, separation, and MS/MS detection of plasma samples spiked with rofecoxib in a span of 5 min. Calibration curves obtained using this RAM turbulent flow coupled column method showed good linearity (R2 > 0.99) and reproducibility (%RSD < or = 7%). The lower limit of quantitation of rofecoxib in plasma samples was found to be 40 ng/ml. The extraction method showed good recovery of rofecoxib from a plasma matrix with minimal signal loss and robustness after more than 200 plasma injections.

Chromatography, High Pressure Liquid↗

Determination of antiretroviral agents in human serum by capillary electrophoresis.

In this work, a simple and rapid electrokinetic chromatography method for the simultaneous separation of different protease inhibitors (indinavir, ritonavir, saquinavir, nelfinavir), nucleoside reverse transcriptase inhibitors (stavudine, zidovudine, didanosine) and non-nucleoside reverse transcriptase inhibitors (nevirapine, efavirenz) was developed. The analyses were performed in a 75 microm i.d. uncoated fused-silica capillary with 48.5 cm length (effective length of 40 cm) using a running buffer consisting of 20 mmol L(-1) sodium dodecyl sulfate, 10 mmol L(-1) sodium tetraborate, 30% acetonitrile and 5% ethanol. Samples were injected hydrodynamically by applying 50 mbar pressure during 6 s. All analytes were separated within 10 min with a voltage of 20 kV. The proposed method was validated for zidovudine, didanosine and efavirenz in human serum. Serum samples were prepared using a solid-phase extraction procedure (Waters Oasis HLB cartridges). For quantitative purposes, stavudine was chosen as the internal standard (IS). Method validation parameters were determined revealing good migration time repeatability (<0.7% RSD) and peak area repeatability (<1.2% RSD). Intra- and inter-day precisions were less than 1.7% and 4.4% RSD, respectively. Matrix matching analytical curves for each drug were linear in the 1.0-20.0 microg mL(-1) interval (r > 0.998). Limits of detection (LOD) were in range of 0.3-0.5 microg mL(-1). The extraction recoveries were higher than 90% with exception of efavirenz, which was 77.4%. Based on the performance characteristics, the proposed method was found suitable for the determination of zidovudine, didanosine and efavirenz in serum samples.

Acetonitriles↗

Microfluidic chip with electrochemiluminescence detection using 2-(2-aminoethyl)-1-methylpyrrolidine labeling.

A tertiary amine derivative, 2-(2-aminoethyl)-1-methylpyrrolidine (AEMP) was successfully developed as electrochemiluminescence (ECL) probe within microfluidic chip using ECL detection in this paper. The system was characterized by the interaction between biotin and avidin. In principle, tertiary amine derivatives containing active group can be used as a potential alternative of traditional tris(2,2'-bipyridine)ruthenium(II) [Ru(bpy)3(2+)] label. Firstly, The ECL efficiency of AEMP was characterized via comparing with that of two coreactants enhancing Ru(bpy)3(2+) ECL, TPA and proline. At same condition, AEMP has a similar ECL efficiency to TPA, and much higher than proline. After AEMP reacted with NHS-LC-biotin (succinimidyl-6-(biotinamido) hexanoate), the products and their ECL were analyzed by directly injecting it in the microfluidic chip. A 4.5 cm microchannel was used to separate the mixture of AEMP and biotinylated AEMP. The present works indicated that AEMP has a good reactivity to the analytes containing carboxyl group with a similar ECL efficiency to TPA. Under optimal condition, the detection limits (based on 3 S/N) of AEMP was 2.7 microM. The system was also validated by the reaction between biotin and avidin. The calculated binding ratio between avidin and biotin based on the present method was 4.4.

Aminocaproates↗

Microchip capillary electrophoresis with amperometric detection for rapid separation and detection of seleno amino acids.

This article describes an effective microchip capillary-electrophoresis protocol for rapid and effective measurements of food-related seleno amino acids, including Se-methionine (Se-Met), Se-ethionine (Se-Eth), Se-methyl cysteine (Se-Cys), utilizing o-phtaldialdeyde/2-mercaptoethanol (OPA/2-ME) derivatization. Relevant parameters of the chip separation and amperometric detection are examined and optimized using a response surface methodology (RSM). Under optimum conditions, the analytes could be separated and detected in a 30 mM borate buffer (pH 9.3, with 28 mM sodium dodecul sulfate) within 300 s using a separation voltage of 2000V and a detection voltage of +0.9 V. Linear calibration plots are observed for micromolar concentrations of the Se-amino acid compounds. The negligible sample volumes used in the microchip procedure obviates surface fouling common to amperometric measurements of selenoamino-acid compounds. The new microchip protocol offers great promise for a wide range of food applications requiring fast measurements and negligible sample consumption.

Amino Acids↗

Indirect chemiluminescence detection for capillary zone electrophoresis of monoamines and catechol using luminol-k3[Fe(CN)6] system.

Indirect chemiluminescence (ICL) detection for capillary electrophoresis (CE) of monoamines and catechol using luminol-K3 [Fe(CN)6] system was described. A strong and stable background chemiluminescence (CL) signal can be generated by luminol-K3 [Fe(CN)6] reaction. Based on the principle of that some phenolic compounds may be oxidized in the presence of K3 [Fe(CN)6], quenching effect of catecholamines for luminol-K3[Fe(CN)6] CL reaction results in a quantifiable decrease in the background signal. The conditions for CE separation and the CL detection for four standard catecholamines were systematically investigated using a homemade CE-ICL system. Under the optimum conditions, the detection limits of dopamine (DA), epinephrine (EP), norepinephrine (NE) and catechol (CA) were determined to be 0.18 mciroM 0.39 microM 0.48 microM and 0.09 microM, respectively. It also has been successfully applied to analyze seven pharmaceutical samples and seven human urine samples.

Adult↗

Pulsed electrochemical detection of orotic acid by an activated potential waveform at a gold working electrode following anion-exchange chromatography.

The application of activated pulsed amperometric detection (APAD) for the determination of orotic acid (OrA) in real samples at a gold working electrode in alkaline solutions, in combination with anion-exchange chromatography, is reported. Such an activated potential waveform was designed with an initial step that involves the formation of redox active species (e.g., adsorbed AuOH/AuO), which in turn is halted upon lowering the applied potential at the detection value while the adsorbed gold hydroxide/oxide species are still catalytically active. A direct comparison between the activated potential waveform and the more commonly used pulsed amperometric detection showed roughly a 20-fold increase in sensitivity. The chromatographic separation of OrA was accomplished by using a microbore anion-exchange column eluted with an isocratic mobile phase composed of 100 mM NaOH+40 mM NaNO(3). Orotic acid was determined at the concentration ranges of 0.2-30 microM (r=0.9997) with an absolute detection limit of 80 pg (10 microL injected). The levels of OrA in cows' milk samples evaluated by standard additions, using 5-aminoorotic acid as an internal standard, ranged from 56 to 126 mg/L. Lower levels were found in raw sheep's milk (<20 mg/L). The assay is shown to be very useful in clinical investigations where relatively high levels of OrA in human urine are correlated to metabolic diseases.

Animals↗