Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Engineering”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82Linked to original sources

Glucocorticoid-inducible retrovector for regulated transgene expression in genetically engineered bone marrow stromal cells.

Transplantable bone marrow stromal cells can be utilized for cell therapy of mesenchymal disorders. They can also be genetically engineered to express synthetic transgenes and subsequently serve as a platform for systemic delivery of therapeutic proteins in vivo. Inducible production of therapeutic proteins would markedly enhance the usefulness of stromal cells for cell therapy applications. We determined whether synthetic corticosteroid hormones can be used to tightly control transgene expression via the glucocorticoid response pathway in primary bone marrow stromal cells. This regulatory mechanism does not require the presence of potentially immunogenic prokaryotic or chimeric "Trans-activators." Further, synthetic corticosteroids are pharmaceutical agents that can be readily used in vivo. We designed a self-inactivating retroviral vector in which expression of the green fluorescent protein (GFP) reporter is controlled by a minimal synthetic promoter composed of five tandem glucocorticoid response elements upstream of a TATAA box. Vesicular stomatitis virus G-pseudotyped retroparticles were synthesized and utilized to transduce cultured cell lines and primary rat bone marrow stromal cells. We have shown that primary rat bone marrow stromal cells could be efficiently engineered with our GRE-containing retrovector, basal reporter expression was low in the absence of exogenous synthetic corticosteroids, and GFP expression was dexamethasone inducible and reversible. To summarize, this strategy allows dexamethasone-induced, "on-demand" transgene expression from transplantable genetically engineered bone marrow stromal cells.

Animals↗

Silicon micromachining to tissue engineer branched vascular channels for liver fabrication.

To date, many approaches to engineering new tissue have emerged and they have all relied on vascularization from the host to provide permanent engraftment and mass transfer of oxygen and nutrients. Although this approach has been useful in many tissues, it has not been as successful in thick, complex tissues, particularly those comprising the large vital organs such as the liver, kidney, and heart. In this study, we report preliminary results using micromachining technologies on silicon and Pyrex surfaces to generate complete vascular systems that may be integrated with engineered tissue before implantation. Using standard photolithography techniques, trench patterns reminiscent of branched architecture of vascular and capillary networks were etched onto silicon and Pyrex surfaces to serve as templates. Hepatocytes and endothelial cells were cultured and subsequently lifted as single-cell monolayers from these two-dimensional molds. Both cell types were viable and proliferative on these surfaces. In addition, hepatocytes maintained albumin production. The lifted monolayers were then folded into compact three-dimensional tissues. Thus, with the use microfabrication technology in tissue engineering, it now seems feasible to consider lifting endothelial cells as branched vascular networks from two-dimensional templates that may ultimately be combined with layers of parenchymal tissue, such as hepatocytes, to form three-dimensional conformations of living vascularized tissue for implantation.

Animals↗

Fabrication of a trileaflet heart valve scaffold from a polyhydroxyalkanoate biopolyester for use in tissue engineering.

Previously, we reported the implantation of a single tissue engineered leaflet in the posterior position of the pulmonary valve in a lamb model. The major problems with this leaflet replacement were the scaffold's inherent stiffness, thickness, and nonpliability. We have now created a scaffold for a trileaflet heart valve using a thermoplastic polyester. In this experiment, we show the suitability of this material in the production of a biodegradable, biocompatible scaffold for tissue engineered heart valves. A heart valve scaffold was constructed from a thermoplastic elastomer. The elastomer belongs to a class of biodegradable, biocompatible polyesters known as polyhydroxyalkanoates (PHAs) and is produced by fermentation (Metabolix Inc., Cambridge, MA). It was modified by a salt leaching technique to create a porous, three-dimensional structure, suitable for tissue engineering. The trileaflet heart valve scaffold consisted of a cylindrical stent (1 mm X 15 mm X 20 mm I.D.) containing three valve leaflets. The leaflets were formed from a single piece of PHA (0.3 mm thick), and were attached to the outside of the stent by thermal processing techniques, which required no suturing. After fabrication, the heart valve construct was allowed to crystallize (4 degrees C for 24 h), and salt particles were leached into doubly distilled water over a period of 5 days to yield pore sizes ranging from 80 to 200 microns. Ten heart valve scaffolds were fabricated and seeded with vascular cells from an ovine carotid artery. After 4 days of incubation, the constructs were examined by scanning electron microscopy. The heart valve scaffold was tested in a pulsatile flow bioreactor and it was noted that the leaflets opened and closed. Cells attached to the polymer and formed a confluent layer after incubation. One advantage of this material is the ability to mold a complete trileaflet heart valve scaffold without the need for suturing leaflets to the conduit. Second advantage is the use of only one polymer material (PHA) as opposed to hybridized polymer scaffolds. Furthermore, the mechanical properties of PHA, such as elasticity and mechanical strength, exceed those of the previously utilized material. This experiment shows that PHAs can be used to fabricate a three-dimensional, biodegradable heart valve scaffold.

Animals↗

Fundamentals of biomechanics in tissue engineering of bone.

The objective of this review is to provide basic information pertaining to biomechanical aspects of bone as they relate to tissue engineering. The review is written for the general tissue engineering reader, who may not have a biomechanical engineering background. To this end, biomechanical characteristics and properties of normal and repair cortical and cancellous bone are presented. Also, this chapter intends to describe basic structure-function relationships of these two types of bone. Special emphasis is placed on salient classical and modern testing methods, with both material and structural properties described.

Animals↗

The design of scaffolds for use in tissue engineering. Part I. Traditional factors.

In tissue engineering, a highly porous artificial extracellular matrix or scaffold is required to accommodate mammalian cells and guide their growth and tissue regeneration in three dimensions. However, existing three-dimensional scaffolds for tissue engineering proved less than ideal for actual applications, not only because they lack mechanical strength, but they also do not guarantee interconnected channels. In this paper, the authors analyze the factors necessary to enhance the design and manufacture of scaffolds for use in tissue engineering in terms of materials, structure, and mechanical properties and review the traditional scaffold fabrication methods. Advantages and limitations of these traditional methods are also discussed.

Animals↗

Potential use of chitosan as a cell scaffold material for cartilage tissue engineering.

One of the most important factors in any tissue-engineering application is the cell substrate. The purpose of this study was the initial evaluation of chitosan, a derivative of the abundant, naturally occurring biopolymer chitin, as a cell scaffold for cartilage tissue engineering. Chitosan scaffolds having an interconnecting porous structure were easily fabricated by simple freezing and lyophilization of a chitosan solution. After rehydration of scaffolds, porcine chondrocytes were seeded onto scaffolds and cultured for up to 28 days in a rotating-wall bioreactor. Chitosan scaffolds supported cell attachment and maintenance of a rounded cell morphology. After 18 days, cells within the scaffolds had synthesized extracellular matrix in which proteoglycan and type II collagen were detected by toluidine blue staining and immunohistochemistry, respectively. Abundant extracellular matrix was found almost exclusively in the periphery of the scaffolds, as scaffold microstructure prevented cells from penetrating to interior regions. Nonetheless, the results suggest that chitosan scaffolds may be a useful alternative to synthetic cell scaffolds for cartilage tissue engineering.

Animals↗

Salt fusion: an approach to improve pore interconnectivity within tissue engineering scaffolds.

Macroporous scaffolds composed of biodegradable polymers have found extensive use as three-dimensional substrates either for in vitro cell seeding followed by transplantation, or as conductive substrates for direct implantation in vivo. Methods abound for creation of macroporous scaffolds for tissue engineering, and common methods typically employ a solid porogen within a three-dimensional polymer matrix to create a well-defined pore size, pore structure, and total scaffold porosity. This study describes an approach to impart improved pore interconnectivity to polymer scaffolds for tissue engineering by partially fusing the solid porogen together prior to creation of a continuous polymer matrix. Three dimensional, porous scaffolds of the copolymer 85:15 poly(lactide-co-glycolide) were fabricated via either a solvent casting/particulate leaching process, or a gas foaming/particulate leaching process. Prior to creation of a continuous polymer matrix the NaCl crystals, which serve as the solid porogen, are partially fused via treatment in 95% humidity. Scanning electron micrographs clearly display fused salt crystals and an enhancement in pore interconnectivity in the salt fused scaffolds prepared via both solvent casting and gas foaming, and the extent of pore interconnectivity is enhanced with longer treatment times. Fusion of salt crystal for 24 h increased the radius of curvature of salt crystals, and led to a twofold increase in the compressive modulus of solvent cast scaffolds (total porosity of 97 +/- 1%). Fusion of NaCl crystals prior to gas foaming resulted in a decrease in scaffold compressive modulus from 277 +/- 60k Pa to 187 +/- 30k Pa (total porosity of 94 +/- 1%). The resulting highly interconnected scaffolds have implications for facilitated cell migration, abundant cell-cell interaction, and potentially improved neural and vascular growth within tissue engineering scaffolds.

Biocompatible Materials↗

In vivo vascular engineering: directed migration of smooth muscle cells to limit neointima.

Pathologic neointima formation requires directional smooth muscle cell (SMC) migration from media to intima. The very direction of SMC migration thus becomes a potential therapeutic target. Here, we hypothesize that proliferating SMC after injury can be redirected using engineered chemotactic gradients of elastin degradation to limit late pathologic neointima formation. Buffered bioerodible polymeric microspheres (MS) were constructed to provide 4-week sustained release of elastase, heat-killed elastase, or polymer only. In vitro elastase function and timecourse of release at 37 degrees C, physiologic pH, and shear was determined. Curves revealed an initial bolus followed by sustained linear release for elastase MS, while controls exhibited baseline hydrolysis of substrate. We then employ controlled perivascular release of elastase after angioplasty to engineer modified in vivo gradients of elastin degradation in rabbit femoral arteries. NZW rabbits (n = 8 each) underwent balloon angioplasty of the common femoral artery followed by perivascular distribution of MS. Significant early perivascular elastin degradation resulted. Concurrently, proliferating SMC were guided peripherally (further from lumen) with treatment without significant changes in total proliferation or inflammation. At 28 days, treatment significantly reduces neointima by 42% relative to controls. These results confirm that directionally guiding SMC responses after injury achieves favorable arterial remodeling and limits development of pathologic neointima. Thus, a potential class of therapeutics and the paradigm of in vivo vascular engineering emerge from this work.

Angioplasty, Balloon, Coronary↗

Novel cell-scaffold interactions encountered in tissue engineering: contractile behavior of musculoskeletal connective tissue cells.

Methods employed in the course of tissue engineering often offer unique opportunities to observe cell-matrix interactions that cannot otherwise be viewed. These observations may provide insights into cell behavior than can contribute important new knowledge about cell biology. One such set of observations led to the discoveries that musculoskeletal connective tissue cells express a contractile muscle actin isoform, alpha-smooth muscle actin, and can contract. This knowledge may help to explain how these cells generate forces required for certain physiological and pathological functions, and this information may inform future approaches to regulate this function to advance tissue engineering. Tissue engineering science is thus emerging as an importance force that can both contribute to cell and molecular biology and add to the fund of knowledge supporting the production of tissue in vitro or in vivo to improve the management of a wide variety of disorders.

Actins↗

Mechanical strain-stimulated remodeling of tissue-engineered blood vessel constructs.

Progress in tissue-engineering research has renewed optimism about the possibility of constructing a physiologically functional blood vessel substitute in the laboratory. To this end, we have explored the use of defined mechanical stimulation to further the development of vascular tissue analogs. We now report our findings on smooth muscle cell and fibroblast-seeded collagen constructs exposed to 10% cyclic strain for 4 or 8 days. Our results demonstrate that 4-day strained constructs exhibit an enhancement of mechanical properties, likely through the remodeling actions of matrix metalloproteinase 2 (MMP-2). Strain-stimulated expression of MMP-2 is accompanied by alterations in elastin and collagen gene expression. In the context of tissue engineering a blood vessel construct, we report that strain-stimulated regulation of MMP-2 activity could have a favorable impact on the structural development of the constructs whereas overexpression of MMP-2 during prolonged exposure to strain (8 days) could have adverse consequences on the structural integrity of the tissue analogs. Taken together, these results illustrate the importance of mechanical stimulus as a major regulatory component of tissue-engineered blood vessel remodeling.

Animals↗

Tissue engineering using magnetite nanoparticles and magnetic force: heterotypic layers of cocultured hepatocytes and endothelial cells.

Novel technologies to establish three-dimensional, in vivo-like tissue consisting of various types of cells are required for tissue engineering. We applied magnetic force to construct a heterotypic, layered coculture system of rat hepatocytes and human aortic endothelial cells (HAECs) that was not limited by cell type. Magnetite cationic liposomes carrying a positive surface charge to improve adsorption accumulated in HAECs at a concentration of 38 pg of magnetite per cell. Magnetically labeled HAECs specifically accumulated onto hepatocyte monolayers at sites where a magnet (4000 G) was positioned, and then adhered to form a heterotypic, layered construct with tight and close contact. This cocultured construct significantly (p < 0.05) enhanced albumin secretion by hepatocytes compared with that in homotypic cultures of hepatocytes or heterotypic cocultures of hepatocytes and HAECs without magnets. These results suggest that this novel use of magnetite nanoparticles and magnetic force, which we refer to as "magnetic force-based tissue engineering" (Mag-TE), offers a major advancement in tissue engineering.

Animals↗

Tissue engineering of cartilage using a hybrid scaffold of synthetic polymer and collagen.

A biodegradable hybrid scaffold of synthetic polymer, poly (DL-lactic-co-glycolic acid) (PLGA), and naturally derived polymer, collagen, was prepared by forming collagen microsponges in the pores of PLGA sponge. This was then used as the three-dimensional scaffold for tissue engineering of bovine articular cartilage, both in vitro and in vivo. In vitro studies show that hybridization with collagen facilitated cell seeding in the sponge and raised seeding efficiency. Chondrocytes adhered to the collagen microsponges, where they proliferated and secreted extracellular matrices with time, filling the space within the sponge. Hematoxylin and eosin staining revealed that most of the chondrocytes after 4 weeks of culture, and almost all cell types after 6 weeks of culture, maintained their phenotypically rounded morphology. While new tissue formed, the scaffold degraded and lost almost 36.9% of its original weight after 10 weeks. Subcutaneous implantation studies in nude mice demonstrated more homogeneous tissue formation in hybrid sponge than in PLGA sponge. The new tissue formed maintained the original shape of the hybrid sponge. The synthetic PLGA sponge, serving as a skeleton, facilitated easy formation into desired shapes and provided appropriate mechanical strength to define the ultimate shape of engineered tissue. Incorporation of collagen microsponges facilitated cell seeding and homogeneous cell distribution and created a favorable environment for cellular differentiation. The hybrid sponge could therefore represent a promising candidate as a three-dimensional scaffold for articular cartilage tissue engineering.

Animals↗

New multi-cue bioreactor for tissue engineering of tubular cardiovascular samples under physiological conditions.

In the present study we have developed a multi-cue bioreactor (MCB) that is capable of delivering a range of stimuli to assist the development of a tissue-engineered construct. The MCB provides an accurate and utilizable computer-controlled pulsatile pump and strain induction mechanism and it has the capability of applying physiological conditions to samples. The device described here emulates the pressure and straining environment found at the aortic root. This function, along with an integral perfusion and sterile containment system, allows for long-term culture and whole-tissue testing capability. Aortic and pulmonary arteries were obtained from freshly isolated porcine hearts and subjected to various loading regimens (Deltapressure/flow/force). Through analyzing data acquired by the MCB transducer array it was possible to differentiate the dynamic mechanical properties of the tissue types tested. In addition, the MCB illustrates a novel concept in cardiovascular tissue engineering: being able to support long-term tissue culture of cell-seeded substrates while they are under the influence of mechanical cues. After 7 days of pulsation in the MCB cell alignment was observed. The MCB represents a versatile model that will enable the development of tissue engineering not only for cardiovascular tissue, but for all tubular tissues such as esophageal, tracheal, and bronchial systems.

Bioreactors↗

Aspects of human factors engineering in home telemedicine and telerehabilitation systems.

Human factors engineering and system design are critical elements in the newly developing field of telerehabilitation. Telerehabilitation is the remote delivery of rehabilitative services such as monitoring, training, and long-term care of persons with disabilities using telecommunications technology. This paper describes projects at the Rehabilitation Engineering Research Center (RERC) on Telerehabilitation in the context of three conceptual models: telecounseling and training, telemonitoring and assessment, and teletherapy. Issues pertaining to human factors engineering design are identified, and ongoing challenges are discussed.

Biomedical Engineering↗

Engineered fusion hybrid vaccine of IL-18 gene-modified tumor cells and dendritic cells induces enhanced antitumor immunity.

Dendritic cell (DC)-tumor fusion hybrid vaccines that facilitate antigen presentation represent a novel powerful strategy in cancer immunotherapy. In our study, we investigated the antitumor immunity derived from the vaccination of fusion hybrids between engineered J558/IL-18 myeloma cells secreting Th1 cytokine IL-18 and DCs. DC/J558/IL-18 could secret a higher level of IL-18 than DCs, efficiently expressed J558 tumor antigen P1A, and enhanced ability of allogeneic T cell stimulation when compared to J558/IL-18. Our data showed that the immunization of BALB/c mice with DC/J558/IL-18 hybrids induced the most potent protective immunity against 1 x 10(6) cells with a J558 tumor challenge, compared to those immunized with the mixture of DCs and J558/IL-18, J558/IL-18, or J558. Furthermore, the immunization of mice with engineered DC/J558/IL-18 hybrids elicited stronger NK activity and J558 tumor-specific cytotoxic T lymphocyte (CTL) responses in vitro. In addition, DC/J558/IL-18 tumor cells into syngeneic mice induced a Th1 dominant immune response to J558 and resulted in tumor regression, which indicated that the antitumor effect mediated by DC/J558/IL-18 appeared to be dependent on TH1 cytokine production. These results demonstrate that the engineered fusion hybrid vaccines that combine Th1 gene-modified tumor with DCs may be an attractive strategy for cancer immunotherapy.

Animals↗

Gene therapy and tissue engineering for urologic dysfunction: status and prospects.

This article reviews the recent advances in gene therapy and tissue engineering for urologic dysfunction. Although the number of gene therapy-based clinical trials has increased dramatically in the field of urologic oncology, such trials are still few within the neurourologic field. Recently, new biologic approaches employing growth factors have been utilized to treat various pathological conditions. Among them, transfer of genes such as those encoding growth factors represents a promising way to deliver therapeutic proteins to malfunctioning tissues, which leads to the improvement of organ function. Tissue engineering, which may eventually be combined with gene therapy, also offers the potential to create new functional genitourinary tissue for regeneration and replacement of tissue lost as a consequence of disease. Thus, both tissue engineering and gene therapy may hold promising new solutions in the urologic field.

Animals↗

What is morally distinctive about genetic engineering?

It sometimes seems that genetic engineering is suspect, both to its practitioners and to the general public, because it is perceived as being somehow unnatural. This essay argues, on the basis of an analysis of two senses of "natural," that there is nothing distinctively morally problematic about genetic engineering, at least on the grounds of its alleged unnaturalness. It does not follow that we cannot distinguish among morally legitimate and morally suspect uses of genetic engineering. But these distinctions can and should be drawn on the basis of the same considerations that enter into the evaluation of particular uses of any other medical procedure.

Ethical Analysis↗

Assessing porcine liver-derived biomatrix for hepatic tissue engineering.

Acellular, biologically derived matrices such as small intestinal submucosa have been extensively utilized to induce tissue regeneration and remodeling of connective tissue, vascular grafts, and urinary bladder; however, decellularized scaffolds have not been explored for their potential utility in hepatic tissue engineering. In the case of both extracorporeal hepatocyte-based devices and implantable hepatocyte-scaffold tissue-engineered constructs, maintenance of hepatocellular function is of prime importance. In this study, we specifically explored decellularized, porcine, liver-derived biomatrix (LBM) as a bioresorbable scaffold for primary hepatocytes. Primary rat hepatocytes were cultured on LBM and compared with well-characterized hepatocyte culture models--double-gel cultures that promote maintenance of liver-specific functions for many weeks, and adsorbed collagen monolayers that lead to the rapid decline of hepatocellular function and viability. Hepatocytes were maintained for up to 45 days on LBM and liver-specific functions such as albumin synthesis, urea production, and P-450 IA1 activity were found to be significantly improved over adsorbed collagen cultures. Our data indicate that LBM may be a favorable alternative to existing scaffolds for tissue engineering in that it is bioresorbable, can be easily manipulated, and supports long-term hepatocellular functions in vitro.

Animals↗