Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “VENTILATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81Linked to original sources

Effect of low-bias flow oscillation with partial liquid ventilation on fluoroscopic image analysis, gas exchange, and lung injury.

OBJECTIVE: To evaluate the effect of low-bias flow oscillation (LBFO) with partial liquid ventilation (PLV) on perfluorochemical evaporation, histopathology, and oxidative tissue damage in an animal model of acute lung injury. DESIGN: Prospective, randomized animal study. SETTING: Research laboratory of a health sciences university. SUBJECTS: Twelve New Zealand White rabbits. INTERVENTIONS: Juvenile rabbits were anesthetized, paralyzed, and ventilated through a tracheostomy with either high-frequency oscillatory ventilation or LBFO. Lung injury was induced by repeated saline lavage, after which perflubron was instilled through a side port of the endotracheal tube. Lateral fluoroscopic images were performed at baseline and at various postfill intervals of animals in the high-frequency oscillatory ventilation-PLV and LBFO-PLV groups. The images were digitalized for computer analysis of the Lung Lucency Index, a surrogate marker of perflubron evaporation. Histopathologic evaluation was performed using a lung-injury scoring system. Malondialdehyde was measured in lung homogenates to assess oxidative damage. MEASUREMENTS AND MAIN RESULTS: There were no significant differences in gas exchange and ventilator settings between groups throughout the experiment. At 300 mins, the high-frequency oscillatory ventilation-PLV group had a significantly higher Lung Lucency Index compared with the LBFO-PLV group in both dependent and nondependent lung regions (a high Lung Lucency Index correlates with increased perflubron loss). Malondialdehyde measurements were not different between groups. Animals treated with LBFO-PLV had a lower histopathologic lung-injury score compared with high-frequency oscillatory ventilation-PLV. CONCLUSION: LBFO-PLV is a viable mode of ventilation in a model of acute lung injury and is associated with significant preservation of perflubron in comparison with high-frequency oscillatory ventilation-PLV. The lower evaporative losses during LBFO-PLV were associated with improved histology scores.

Animals↗

High frequency venturi jet ventilation. Adult respiratory distress syndrome--a case report.

A Penlon Nuffield Series 200 Ventilator, adapted for use as a high frequency jet ventilator, was used to treat a patient with adult respiratory distress syndrome. Adequate alveolar ventilation with this method was achieved with lower mean intrapulmonary pressure (5.4 cmH2O) than with conventional intermittent positive pressure ventilation (IPPV) (6 cmH2O). An improved cardiac output was also apparent, as judged by a better systemic blood pressure [105/50 mmHg for high frequency jet ventilation (HFJV) compared to 90/40 mmHg for IPPV] and a lower central venous pressure 6 cmH2O for HFJV as compared to 9.5 cmH2O with conventional IPPV. During HFJV, the patient's need for sedatives and narcotics was reduced. This allowed an assessment to be made of any potential neurological damage caused by the cervical fracture. An assessment had not been possible during conventional ventilation due to the heavy narcotic and sedative regime required to settle the patient. This case report provides further evidence that HFJV is a useful adjunct in the management of patients requiring mechanical ventilation and also that the Penlon Nuffield Series 200 Ventilator is capable of high frequency jet ventilation.

Aged↗

Efficacy of synchronized IMV on weaning neonates from the ventilator.

This study evaluated the efficacy of a new patient-triggered ventilator that triggered the patient's inspiratory effort by detecting the change in airflow by means of a 'hot wire' anemometer. This ventilator was used in both the conventional and the synchronized intermittent mandatory ventilation (SIMV) modes in seven neonates. Values for blood gas, spontaneous breathing rate, tidal volume of spontaneous breaths and minute volume were compared in all seven neonates. The resistive work of spontaneous breathing in five neonates, obtained with synchronized intermittent mandatory ventilation was compared with the values obtained using conventional mechanical ventilation on the previous day of weaning from the ventilator. At each the inflation time studied (0.4, 0.3, 0.24 s), all mechanical breath occurred synchronously with infants' inspiratory efforts. The median trigger delay was 80 ms. Oxygenation was improved on the new system compared with the conventional system. Tidal volume of spontaneous breathing and minute volume were increased with SIMV compared with conventional mechanical ventilation, although the resistive work of spontaneous breathing was decreased with SIMV. The tidal volume of spontaneous breaths was more constant with SIMV versus conventional mechanical ventilation. Thus, the airway flow-triggered SIMV may lessen inspiratory muscle fatigue during weaning process. We conclude that the SIMV is useful in weaning neonates from the ventilator.

Equipment Design↗

Reduction of mismatch of global ventilation and perfusion on exercise is related to exercise capacity in chronic heart failure.

BACKGROUND: The inability to match lung perfusion to ventilation because of a reduced cardiac output on exercise contributes to reduced exercise capacity in chronic heart failure. OBJECTIVE: To quantify ventilation to perfusion matching at rest and at peak exercise in patients with chronic heart failure and relate this to haemodynamic and ventilatory variables of exercise capacity. DESIGN: Eight men in New York Heart Association class II underwent maximal bicycle ergometry with expired gas analysis. MAIN OUTCOME MEASURES: On separate days, ventilation and perfusion gamma camera imaging was performed at rest, and at 80% of previous peak exercise heart rate during bicycle ergometry. The vertical distribution of mismatch between ventilation and perfusion (V/Q) was estimated from subtracted profiles of activity (ventilation and perfusion) to derive a numerical index of global mismatch. RESULTS: Maximal mean (SD) oxygen consumption on bicycle ergometry was 16.0 (4.5) ml min-1 kg-1. There was a reduction in the global V/Q mismatch index from 23.96 (5.90) to 14.88 (7.90) units (p < 0.01) at rest and at peak exercise. Global V/Q mismatch index at peak exercise correlated negatively with maximal minute ventilation (R = -0.90, p < 0.01) and with maximal mean arterial pressure (R = -0.79, p < 0.05), although no relation was seen with maximal oxygen consumption. The reduction in global V/Q mismatch index from rest to peak exercise correlated with maximal oxygen consumption (R = 0.88, p < 0.01), and with maximal minute ventilation (R = 0.87, p < 0.01). CONCLUSIONS: During exercise in patients with chronic heart failure, there is a reduction in the global V/Q mismatch index. A lower global V/Q mismatch index at peak exercise is associated with higher maximal ventilation. The reduction in global V/Q mismatch index on exercise correlates well with maximal exercise capacity. This may imply that the inability to perfuse adequately all regions of lung on exercise and match this to ventilation is a factor determining exercise capacity in chronic heart failure.

Aged↗

High-frequency partial liquid ventilation in respiratory distress syndrome: hemodynamics and gas exchange.

Partial liquid ventilation using conventional ventilatory schemes improves lung function in animal models of respiratory failure. We examined the feasibility of high-frequency partial liquid ventilation in the preterm lamb with respiratory distress syndrome and evaluated its effect on pulmonary and systemic hemodynamics. Seventeen lambs were studied in three groups: high-frequency gas ventilation (Gas group), high-frequency partial liquid ventilation (Liquid group), and high-frequency partial liquid ventilation with hypoxia-hypercarbia (Liquid-Hypoxia group). High-frequency partial liquid ventilation increased oxygenation compared with high-frequency gas ventilation over 5 h (arterial oxygen tension 253 +/- 21.3 vs. 17 +/- 1.8 Torr; P < 0.001). Pulmonary vascular resistance decreased 78% (P < 0.001), pulmonary blood flow increased fivefold (P < 0.001), and aortic pressure was maintained (P < 0.01) in the Liquid group, in contrast to progressive hypoxemia, hypercarbia, and shock in the Gas group. Central venous pressure did not change. The Liquid-Hypoxia group was similar to the Gas group. We conclude that high-frequency partial liquid ventilation improves gas exchange and stabilizes pulmonary and systemic hemodynamics compared with high-frequency gas ventilation. The stabilization appears to be due in large part to improvement in gas exchange.

Animals↗

Inspiratory oscillatory flow with a portable ventilator: a bench study.

INTRODUCTION: We observed an oscillatory flow while ventilating critically ill patients with the Dräger Oxylog 3000 transport ventilator during interhospital transfer. The phenomenon occurred in paediatric patients or in adult patients with severe airway obstruction ventilated in the pressure-regulated or pressure-controlled mode. As this had not been described previously, we conducted a bench study to investigate the phenomenon. METHODS: An Oxylog 3000 intensive care unit ventilator and a Dräger Medical Evita-4 NeoFlow intensive care unit ventilator were connected to a Dräger Medical LS800 lung simulator. Data were registered by a Datex-S5 Monitor with a D-fend flow and pressure sensor, and were analysed with a laptop using S5-Collect software. Clinical conditions were simulated using various ventilatory modes, using various ventilator settings, using different filters and endotracheal tubes, and by changing the resistance and compliance. Data were recorded for 258 combinations of patient factors and respirator settings to detect thresholds for the occurrence of the phenomenon and methods to overcome it. RESULTS: Under conditions with high resistance in pressure-regulated ventilation with the Oxylog 3000, an oscillatory flow during inspiration produced rapid changes of the airway pressure. The phenomenon resulted in a jerky inspiration with high peak airway pressures, higher than those set on the ventilator. Reducing the inspiratory flow velocity was effective to terminate the phenomenon, but resulted in reduced tidal volumes. CONCLUSION: Oscillatory flow with potentially harmful effects may occur during ventilation with the Dräger Oxylog 3000, especially in conditions with high resistance such as small airways in children (endotracheal tube internal diameter <6 mm) or severe obstructive lung diseases or airway diseases in adult patients.

Adult↗

Negative pressure ventilation vs external high-frequency oscillation during rigid bronchoscopy. A controlled randomized trial.

STUDY OBJECTIVES: To compare the effectiveness of two modalities of external ventilation during rigid bronchoscopy: intermittent negative pressure ventilation (INPV) and external high-frequency oscillation (EHFO). DESIGN: Prospective, controlled, randomized, nonblinded study. SETTING: University-affiliated hospital. PATIENTS: Seventy patients undergoing interventional rigid bronchoscopy for tracheobronchial lesions were enrolled into the study. INTERVENTIONS: Mechanical ventilation was performed by INPV or EHFO. When pulse oximetry was < 90%, manually assisted ventilation was delivered. MEASUREMENTS AND RESULTS: Arterial blood gases were sampled preoperatively and intraoperatively. Most patients in both groups had normal intraoperative PaCO(2) (mean, 43. 6 +/- 11.8 mm Hg under EHFO and 37.4 +/- 8.2 mm Hg under INPV; p = 0.012), and acidemia occurred in 9 of 35 patients of EHFO group and in 2 of 35 patients of INPV group (p = 0.049). Hypercapnia (PaCO(2) > 50 mm Hg) was observed in 10 patients under EHFO and in 2 with INPV (p = 0.026). Intraoperative mean PaO(2) was similar (101.4 +/- 52.9 mm Hg with EHFO and 124.2 +/- 50.3 mm Hg with INPV; p = 0.07), but O(2) supply was different (3.5 +/- 2.3 L/min during INPV and 8.5 +/- 6.2 L/min during EHFO; p < 0.001). Intraoperative hypoxemia (PaO(2) < 60 mm Hg) occurred in five patients with EHFO and two with INPV (p = 0.426). Three EHFO patients required manually assisted ventilation (mean, 0.2 +/- 0.9), but no INPV patient did (p = 0.142). CONCLUSIONS: External negative pressure ventilation appears to be a suitable choice during rigid bronchoscopy: both EHFO and INPV ensure effective ventilation and comfortable operating conditions in the majority of patients. Some patients may receive inadequate ventilation with EHFO, developing respiratory acidosis and requiring manually assisted ventilation. In comparison with INPV, EHFO requires a higher fraction of inspired oxygen.

Adult↗

[Evaluation of amplified spontaneous pattern ventilation in postoperative patients. Comparison with pressure support].

HYPOTHESIS: Amplified spontaneous pattern (ASP) ventilation is a new method for giving partial support by reproducing, in an amplified manner, the patients' own spontaneous flow wave form, thereby optimizing patient adaptation to support. OBJECTIVES: To study clinical use of ASP ventilation for the first time in terms of flow wave form, patient synchronization, ventilation pattern, work of breathing (WOB), and inspiratory effort by transpulmonary pressure (TPP) and to compare ASP and pressure support ventilation applied in a similar clinical setting. PATIENTS AND METHOD: We studied 20 patients after heart surgery during weaning from controlled ventilation. Each patient was ventilated during 4 phases of 15 min each with two similar levels of support using ASP and PS applied successively and randomly. Maximum support (ASPmax and PSmax) was that which was set to give the same respiratory frequency (F) and tidal volume (VT) as that recorded during the earlier period of controlled ventilation. Half support (PEA1/2 and PS1/2) was set for half the aforementioned levels. At the end of each phase we obtained gas measurements and flow (V) curves and VT and pressure in airways and esophagus (Pes) to measure F, VT, the ratio of inspiratory to total time (TI/TTOT and TPP, as well as the VT/Pes loop with a mechanical ventilation monitor. The WOB was determined by measuring area under the curve (Campbell's method). RESULTS: We observed no significant differences between the two modes, with similar levels of support, with regard to ventilation (PaCO2) or ventilatory pattern (F, VT, TI/TTOT). De-adaptation occurred, however, eight times with PS (25%) but never with ASP. WOB and TPP decreased with PS when level of support increased, whereas with ASP these variables were constant regardless of level of amplification within the normal range. CONCLUSIONS: Adaptation to support is better with ASP than with PS during postoperative weaning and causes no significant respiratory work overload.

Adaptation, Physiological↗

The clinical characteristics at the onset of a severe asthma attack and the effects of high frequency jet ventilation for severe asthmatic patients.

To clarify the relationship between the clinical characteristics and the effects of high frequency jet ventilation based on the differences in the speed of deterioration in severe asthmatic patients who required intubation and mechanical ventilation, we classified 37 severe asthmatics into two groups (acute onset group: n = 20, intubated within 24 hours; slow onset group: n = 17, intubated over 3 days) and measured the arterial blood gas values, the duration of mechanical ventilation, and the peak inspiratory pressure during synchronized intermittent mechanical ventilation with or without high frequency jet ventilation. The acute onset group showed a significantly higher incidence of cyanosis (75% vs. 41%, p < 0.05), an acute loss of consciousness (90% vs. 53%, p < 0.05), severe mixed acidosis with extreme hypercapnoea (pH 7.11 +/- 0.19, PaCO2 94.1 +/- 10.7 mmHg, BE -8.3 +/- 1.7 mEq/l), and a more elevated peak inspiratory pressure (59.7 +/- 1.8 mmHg vs. 41.1 +/- 1.8 mmHg, p < 0.05) during synchronized intermittent mechanical ventilation at admission, compared with the slow onset group (p < 0.05). The slow onset group required a more prolonged mechanical ventilation than the acute onset group (5.4 +/- 4.0 vs. 3.0 +/- 2.4 days, p < 0.05), in spite of a lower peak inspiratory pressure than that observed in the acute onset group, because of either a large amount of secretion or an infection in the airway. Both the high peak inspiratory pressure and the severe mixed acidosis with markedly elevated hypercapnoea were significantly reduced by the application of high frequency jet ventilation between the intra- and the inter-groups. These findings thus indicated the existence of significant differences in the clinical features and pathogenesis of airway hyperreactivity between these two groups, and the application of high frequency jet ventilation to the status asthmaticus was thus found to be effective.

Acute Disease↗

High-frequency jet ventilation in neonatal pulmonary hypertension.

To determine if high-frequency jet ventilation is beneficial in neonates with persistent pulmonary hypertension, we compared the ventilator settings, blood gas concentrations, and outcome of infants who met established criteria for a high predictive mortality. During a six-year period, 14 neonates who had severe respiratory failure and hypoxemia while receiving conventional ventilation were treated with high-frequency jet ventilation. Twenty-three comparable infants meeting the same criteria were treated exclusively with conventional ventilation. After initiation of high-frequency jet ventilation there was a significant reduction in mean airway pressure and partial pressure of arterial carbon dioxide (PaCO2). In contrast, neonates treated exclusively with conventional ventilation continued to have higher airway pressures and PaCO2. However, there was no difference in the alveolar-to-arterial oxygen gradient, air leakage, incidence of bronchopulmonary dysplasia, or duration of assisted ventilation or oxygen supplementation. Furthermore, mortality was comparable in both groups of infants. These preliminary observations suggest that high-frequency jet ventilation can reduce airway pressure and PaCO2 in neonates with persistent pulmonary hypertension but does not appear to improve outcome.

Carbon Dioxide↗

Partial liquid ventilation for the prevention of mortality and morbidity in paediatric acute lung injury and acute respiratory distress syndrome.

BACKGROUND: Acute lung injury, and acute respiratory distress syndrome, are syndromes of severe respiratory failure. Children with acute lung injury or acute respiratory syndrome have high mortality and significant morbidity. Partial liquid ventilation is proposed as a less injurious form of respiratory support for these children. Uncontrolled studies in adults have shown improvement in gas exchange and lung compliance with partial liquid ventilation A single uncontrolled study in six children with acute respiratory syndrome showed some improvement in gas exchange during three hours of partial liquid ventilation. OBJECTIVES: To assess whether partial liquid ventilation reduces either mortality or morbidity, or both, in children with acute lung injury or acute respiratory syndrome. SEARCH STRATEGY: We searched The Cochrane Central Register of Controlled Trials (CENTRAL), The Cochrane Library issue 2, 2003; MEDLINE (1966 to April 2003); and CINAHL (1982 to April 2003); intensive care journals and conference proceedings; reference lists and 'grey literature'. SELECTION CRITERIA: Randomized controlled trials which compared partial liquid ventilation with other forms of ventilation, in children (28 days - 18 years) with acute lung injury or acute respiratory syndrome, reporting one or more of the following: mortality; duration of mechanical ventilation, respiratory support, oxygen therapy, stay in the intensive care unit, or stay in hospital; infection; or long term cognitive impairment or neurodevelopmental progress or other long term morbidities. DATA COLLECTION AND ANALYSIS: Two reviewers independently evaluated the quality of the relevant studies and extracted the data from the included studies. MAIN RESULTS: Only one study enrolling 182 patients (only reported as an abstract in conference proceedings) was identified and found eligible for inclusion: the authors report only limited results. The trial was stopped prematurely and therefore under-powered to detect any significant differences. The only outcome of clinical significance available was 28 day mortality: there was no statistically significant difference between groups with a relative risk for 28 day mortality in the partial liquid ventilation group of 1.54 (95% confidence intervals of 0.82 to 2.9). REVIEWERS' CONCLUSIONS: There is no evidence from randomized controlled trials to support or refute the use of partial liquid ventilation in children with acute lung injury or acute respiratory syndrome: adequately powered, high quality randomized controlled trials are still needed to assess its efficacy. Clinically relevant outcome measures should be assessed (mortality at discharge and later, duration of respiratory support and hospital stay, and long-term neurodevelopmental outcomes) and the studies should be published in full.

Adolescent↗

Anesthesia for microlaryngeal surgery: the case for subglottic jet ventilation.

Although the techniques for surgery on the endolarynx using suspension and the operating microscope have been fully developed, the safest, and least obtrusive anesthetic technique has yet to be manifested, as evidenced by more than 200 references to anesthesia for microlaryngoscopy in the world literature. This study reviews the physiology, physics, and problems of each anesthetic technique. In light of this review, animal and human studies are reported demonstrating the utility and safety of subglottic ventilation when provided with proper monitoring using an automatic ventilator. A modified Ben-Jet tube is reported, which has a 1-mm ID channel to monitor PCO2 and tracheal pressure. This self-centering 3.0-mm tube, which extends 6 to 8 cm below the glottis, is unobtrusive for the surgeon. The subglottic tube, which is much less likely to be malaligned, is much more acceptable to the anesthesiologist. Anesthesia, by intravenous sedation, utilizes neuromuscular blockade while ventilating through the jet tube powered by an automatic ventilator with an automatic shutdown feature attached to the monitor tube to prevent inadvertent barotrauma. The third phase of this study compared fluoroplastic, used in a prototype jet ventilation tube, with 6-mm Silastic, Red Rubber, and polyvinyl chloride (PVC) tubes when struck by maximum power of CO2, Nd-YAG, and K-532 lasers. The test was performed in a closed chamber in which concentrations of oxygen and nitrogen were controlled. Although damaged by the CO2 laser beam, the fluoroplastic tubes did not continue burning when the laser was turned off in 100% oxygen, even when coated by blood. The other three tubes continued to burn in 23% oxygen. Neither the KTP nor Nd-YAG laser damaged the Teflon tube, while they ignited a sustained flame in 30% oxygen. This study supports the use of fluoroplastic for a laser safe jet ventilation tube. It also demonstrates the danger of tube fires, even in low oxygen concentrations, when using Silastic, rubber, and PVC tubes in laser laryngeal surgery. There was no difference in the flammability of Silastic, rubber or PVC when struck by these lasers in this study. For these reasons, subglottic ventilation using a fluoroplastic, monitored, self-centering, subglottic, jet ventilation tube driven by an automatic ventilator with a shutdown feature, in the event of excessive pressure buildup, is proposed for anesthetizing healthy patients undergoing suspension microlaryngoscopy, and who have no airway obstructing lesion. A large tube with inflatable cuff is indicated when a supraglottic lesion may obstruct the airway.

Anesthesia, General↗

A new application of an old method for respiratory mechanics measurements: the passive inflation method in newborn infants during pressure-controlled ventilation.

We have previously described a passive inflation method during constant inspiratory flow for measuring total respiratory elastance and resistance during mechanical ventilation in newborns. The simple method for measuring respiratory mechanics had been assessed during decelerating inspiratory flow obtained with pressure controlled ventilation (PCV). We report an application of this method to preterm and full-term mechanically ventilated newborn infants and a comparison with the occlusion method. Twenty-one newborn infants (birth weight 1,060 to 3,650 g; gestational age 26 to 41 weeks), between 1 to 55 days of postnatal age, were enrolled in the study. They were ventilated with a "Servo ventilator 900C," first set in the pressure-controlled mode and then in the volume-controlled mode without changing the tidal volume (VT), inspiratory time or ventilator rate. Flow was measured through a pneumotachograph inserted between the endotracheal tube (ETT) and the breathing circuit; VT was obtained by integration of flow and airway pressure measured directly at the airway opening. Flow, volume, and pressure were plotted on analog X/Y tables to obtain pressure-volume (P/V) and flow-volume (V/V) loops, as well as pressure-time curves. Occlusion was performed by using the end-inspiratory and the end-expiratory pause buttons of the ventilator. The passive inflation method during PCV was based on the analysis of P/V and V/V loops and provided compliance (Crs(PC)infl.), resistance Rrs(PC)infl.) of the respiratory system, and intrinsic positive end-expiratory pressure (PEEP(PC)i,infl.). These values were compared with (1) compliance (Crs(PC)occl.) and intrinsic positive end-expiratory pressure (PEEP(PC)i,occl.) measured by the occlusion method during PCV; (2) static (Crs(VC),occl.) and dynamic (Crs(VC),dyn.) compliance, airway (R(aw)(VC),), tissue (Rrs(VC),visc.) and total resistance (Rrs(VC),occl.), and intrinsic positive end-expiratory pressure (PEEP(VC)i,occl.) measured by the occlusion method during volume-controlled ventilation. Crs(PC),infl. correlated well with Crs(PC),occl., Crs(VC),occl., and Crs(VC),dyn.. Furthermore, Crs(PC),infl. and Crs(VC),dyn. did not differ significantly. Rrs(PC),infl. correlated well and did not differ significantly from total inspiratory resistance, i.e., the sum of R(aw)(VC) and Rrs(VC),vis. PEEPPC,i,infl. correlated well and did not differ significantly from PEEP(PC)i.occl. and from PEEP(VC),i,occl. The passive inflation method can be used during PCV with a decelerating flow waveform. It provides dynamic compliance, inspiratory resistance of the respiratory system, and intrinsic PEEP from the analysis of V/V and P/V loops recorded at the airway opening. This technique is simple to use and well tolerated by preterm and full-term ventilated newborn infants. It can be a good alternative to occlusion methods.

Airway Resistance↗

The effect of inspired oxygen concentration on the ventilation-perfusion distribution in inhomogeneous lungs.

The coupled conservation of mass equations for oxygen, carbon dioxide and nitrogen are written down for a lung model consisting of two homogeneous alveolar compartments (with different ventilation-perfusion ratios) and a shunt compartment. As inspired oxygen concentration and oxygen consumption are varied, the flux of oxygen, carbon dioxide and nitrogen across the alveolar membrane in each compartment varies. The result of this is that the expired ventilation-perfusion ratio for each compartment becomes a function of inspired oxygen concentration and oxygen consumption as well as parameters such as inspired ventilation and alveolar perfusion. Another result is that the "inspired ventilation-perfusion ratio and the "expired ventilation-perfusion ratio differ significantly, under some conditions, for poorly ventilated lung compartments. As a consequence, we need to distinguish between the "inspired ventilation-perfusion distribution, which is independent of inspired oxygen concentration and oxygen consumption, and the "expired ventilation-perfusion distribution, which we now show to be strongly dependent on inspired oxygen concentration and less dependent oxygen consumption. Since the multiple inert gas elimination technique (MIGET) estimates the "expired ventilation-perfusion distribution, it follows that the distribution recovered by MIGET may be strongly dependent on inspired oxygen concentration.

Administration, Intranasal↗

Effect of surfactant on ventilation-induced mediator release in isolated perfused mouse lungs.

The human acute respiratory distress syndrome (ARDS) is a severe pulmonary complication with high mortality rates. To support their vital functions, patients suffering from ARDS are mechanically ventilated. Recently it was shown that low tidal volume ventilation reduces mortality and pro-inflammatory mediator release in these patients, suggesting biotrauma as a side effect of mechanical ventilation. Because the application of exogenous surfactant has been proposed as a treatment for ARDS, we investigated the effect of surfactant on ventilation-induced release of tumor necrosis factor (TNF), interleukin-6 (IL-6) and 6-keto-PGF(1 alpha) (the stable metabolite of prostacyclin) in isolated perfused mouse lungs ventilated with high end-inspiratory pressures. Instillation of 100mg/kg surfactant into the lungs was well tolerated and improved tidal volume, pulmonary compliance and alveolar expansion. Exogenous surfactant increased the ventilation-induced liberation of TNF and IL-6 into the perfusate, but had no effect on the release of 6-keto-PGF(1 alpha). The surfactant preparation used reduced baseline TNF production by murine alveolar macrophages, indicating that the exaggeration of ventilation-induced TNF release cannot be explained by a direct effect of surfactant on these cells. We hypothesize that ventilation-induced mediator release is explained by stretching of lung cells, which is reinforced by surfactant. The findings that in this model of ventilation-induced lung injury exogenous surfactant at the same time improved lung functions and enhanced mediator release suggest that surfactant treatment may prevent barotrauma and augment biotrauma.

6-Ketoprostaglandin F1 alpha↗

The AVL-mode: a safe closed loop algorithm for ventilation during total intravenous anesthesia.

The Adaptive Lung Ventilation Controller (ALV-Controller) represents a new approach to closed loop control of ventilation. It is based on a pressure controlled ventilation mode. Adaptive lung ventilation signifies automatic breath by breath adaptation of breathing patterns to the lung mechanics of an individual patient. The specific goals are to minimize work of breathing, to maintain a preset alveolar ventilation and to prevent the occurrence of intrinsic PEEP. We ventilated 5 patients undergoing major abdominal procedures using ALV. ALV was tolerated well in all patients. Alveolar ventilation was preset between 5500 and 6500 ml/min. Serial dead space (Vds) and respiratory time constant (resistance * compliance) of the patients ranged from 104 to 164 ml and 0.74 to 1.5 s, respectively. The resulting respiratory rates ranged from 8 to 15 breaths/min, the tidal volumes from 542 to 829 ml, and the applied maximum inspiratory pressures from 15.5 to 18.9 mbar. Expiratory time was sufficient in all cases to allow complete expiration and to avoid intrinsic PEEP. I: E-relations ranged from 0.36 to 0.76. After a step change in alveolar ventilation rise times of the breathing patterns were recorded at values from 7 to 67 s. Overshoot did not reach statistic significance compared to the variations in breathing patterns which occurred during stable measuring periods. Accuracy of the controller was high (27.8 ml difference between preset and applied alveolar ventilation in the mean) and stability was sufficient for clinical purposes. The results of this preliminary study show that the breathing patterns selected by the controller were well adapted to the lung mechanics of the patients. Respiratory rates, inspiratory pressures and tidal volumes were within the clinically acceptable range in all patients.

Adult↗

High fat, low carbohydrate, enteral feeding in patients weaning from the ventilator.

OBJECTIVE: To study whether high fat, low carbohydrate enteral nutrition could reduce VCO2 in patients during ventilator support and weaning from the ventilator in order to facilitate the weaning process. DESIGN: prospective, randomized controlled study. SETTING: Medical ICU of a university hospital. PATIENTS: 32 ventilator-dependent patients with a prospect of weaning from mechanical ventilation. INTERVENTIONS: high fat feeding administered to 15 patients and standard isocaloric feeding administered to 17 patients, both in a dosage of 1.5 times basal metabolic rate. MEASUREMENTS AND RESULTS: Respiratory and metabolic measurements were obtained both during mechanical ventilation and weaning procedures. High fat feeding was associated with significantly lower RQ values compared with standard feeding; the mean (+/- SEM) RQ values during mechanical ventilation amounted to 0.91 +/- 0.01 and 1.00 +/- 0.02 and during weaning to 0.72 +/- 0.02 and 0.86 +/- 0.02 for high fat and standard nutrition respectively (both p-values < 0.001). High fat feeding reduced the CO2-excretion both during mechanical ventilation and weaning, but only the decrease during weaning proved to be significant; the mean (+/- SEM) CO2-excretion amounted to 0.177 +/- 0.010 and 0.231 +/- 0.011 1/min STPD for the high fat and standard feeding respectively (p < 0.01). No significant differences were found in the PaCO2 during weaning between the two feeding groups. CONCLUSION: High fat, low carbohydrate enteral feeding significantly reduced the RQ values in ventilated patients with decreases in VCO2, but in this study failed to reduce PaCO2 during weaning from the ventilator.

Analysis of Variance↗

Inspiratory effort and measurement of dynamic intrinsic PEEP in COPD patients: effects of ventilator triggering systems.

OBJECTIVE: To investigate effects of ventilator triggering systems (pressure and flow triggering: PT and FT) on measurement of dynamic intrinsic PEEP (PEEPidyn) and patient-ventilator interaction in patients with chronic obstructive pulmonary disease during weaning from mechanical ventilation. DESIGN: Prospective study. SETTING: Medical/surgical intensive care unit of an academic hospital. PATIENTS AND PARTICIPANTS: 6 COPD patients with acute respiratory failure ready to wean. MEASUREMENTS: We measured flow, airway opening, esophageal and gastric pressures. Minute ventilation, breathing pattern and pressure time product (PTP) of the respiratory muscles and of the diaphragm were obtained during spontaneous ventilation through a mechanical ventilator (Puritan-Bennett 7200ae). Two triggering systems, namely PT and FT, were evaluated. RESULTS: The inspiratory muscles effort necessary to overcome the triggering system overestimated PEEPidyn measurement of an amount equal to 49 +/- 2 and 58 +/- 3% during respectively pressure and flow triggering. FT increased tidal volume and minute ventilation and decrease PTP/b and PTP/min of the respiratory muscles and diaphragm. CONCLUSIONS: To correctly measure PEEPidyn, the inspiratory effort produced to overcome PEEPi and to trigger the ventilator must be discriminated. Application of flow triggering requires less effort to initiate inspiration and provide a positive end-expiratory pressure level that is able to unload the respiratory muscles by reducing PEEPi. With flow triggering higher minute ventilation are obtained in COPD patients during the weaning phase.

Acute Disease↗