Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Solid Phase Extraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81Linked to original sources

MIP-based solid phase extraction cartridges combined with MIP-based sensors for the detection of microcystin-LR.

Microsystin-LR is one of the most widespread and dangerous toxins produced by the freshwater Cyanobacteria. The contamination of water supplies with microcystin-LR has been reported in several areas around the world and the development of an easy-to-use, rapid, robust and inexpensive sensor for this toxin is urgently required. In this work an artificial receptor for microcystin-LR was synthesised using the technique of molecular imprinting. The composition of the molecularly imprinted polymer (MIP) was optimised using computer modelling. The synthesised polymer was used both as a material for solid-phase extraction (SPE) and as a sensing element in a piezoelectric sensor. Using the combination of SPE followed by detection with a piezoelectric sensor the minimum detectable amount of toxin was 0.35 nM. The use of MIP-SPE provided up to 1000 fold pre-concentration, which was more than sufficient for achieving the required detection limit for microcystin-LR in drinking water (1 nM). This work is the first example where the same MIP receptor has been used successfully for both SPE and the corresponding sensor.

Adsorption↗

Solid-phase extraction combined with high-performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry analysis of pesticides in water: method performance and application in a reconnaissance survey of residues in drinking water in Greater Cairo, Egypt.

Monitoring of water resources for pesticide residues is often needed to ensure that pesticide use does not adversely impact the quality of public water supplies or the environment. In many rural areas and throughout much of the developing world, monitoring is often constrained by lack of testing facilities; thus, collection of samples and shipment to centralized laboratories for analysis is required. The portability, ease of use, and potential to enhance analyte stability make solid-phase extraction (SPE) an attractive technique for handling water samples prior to their shipment. We describe performance of an SPE method targeting a structurally diverse mixture of 25 current-use pesticides and two common degradates in samples of raw and filtered drinking water collected in Greater Cairo, Egypt. SPE was completed in a field laboratory in Egypt, and cartridges were shipped to the United States for elution and high-performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry analysis. Quantitative and reproducible recovery of 23 of 27 compounds (average = 96%; percent relative standard deviation = 21%) from matrix spikes (1 microg L-1 per component) prepared in the field and from deionized water fortified similarly in the analytical laboratory was obtained. Concurrent analysis of unspiked samples identified four parent compounds and one degradate in drinking water samples. No significant differences were observed between raw and filtered samples. Residue levels in all cases were below drinking water and "harm to aquatic-life" thresholds, indicating that human and ecological risks of pesticide contamination were relatively small; however, the study was limited in scale and scope. Further monitoring is needed to define spatial and temporal variation in residue concentrations. The study has demonstrated the feasibility of performing studies of this type using SPE to extract and preserve samples in the field. The approach should be broadly applicable in many settings.

Chromatography, High Pressure Liquid↗

Tris(2,2'-bipyridine)ruthenium(II) electrogenerated chemiluminescence of alkaloid type drugs with solid phase extraction sample preparation.

An electrogenerated chemiluminescence (ECL) method for the determination of pethidine, atropine, homatropine and cocaine is described. The optimum conditions were found to be similar for all of these compounds although the ECL emission intensity for cocaine was an order of magnitude lower than for pethidine due to their different chemical structures. Linear calibrations were obtained for all the compounds at pH 10 in borate buffer (0.05 mol l-1) at 1.3 V. Limits of detection of 6.8 x 10(-8), 2.2 x 10(-7), 3.2 x 10(-7) and 6.5 x 10(-7) mol l-1, respectively, were achieved for pethidine, atropine, homatropine and cocaine in standard solutions. Solid-phase extraction was used to separate the drugs from their matrix and the method was applied to the determination of spiked urine samples. The limits of quantitation for pethidine, atropine, homatropine and cocaine in urine were 1.0 x 10(-6), 2.0 x 10(-6), 2.0 x 10(-6) and 4.0 x 10(-6) mol l-1, respectively, with recoveries of between 90 and 110%.

Alkaloids↗

Molecularly imprinted solid-phase extraction of naphthalene sulfonates from water.

A new polymeric sorbent synthesised by exploiting molecular imprinting technology has been used to selectively extract naphthalene sulfonates (NSs) directly from aqueous samples. In the non-covalent molecular imprinting approach used to prepare this polymer, 1-naphthalene sulfonic acid (1-NS) and 4-vinylpyridine (4-VP) were used as a template molecule and functional monomer, respectively, and both dissolved in a mixture of methanol/water (4:1) as porogen together with the cross-linker ethylene glycol dimethacrylate. The new non-covalent molecularly imprinted polymer (MIP) prepared in aqueous environment was used as a sorbent in solid-phase extraction (SPE) to selectively extract a group of naphthalene mono- and disulfonates. When one litre of a standard aqueous solution, which contained a mixture of eight NSs, was percolated through the SPE cartridge, all the NSs were retained on the MIP because of the cross-reactivity of the polymer. Recoveries were higher than 80% for all the compounds even after a clean-up step with methanol (MeOH). The MIP was also used to analyse water from the Ebro river.

Naphthalenesulfonates↗

Polyoxymethylene solid phase extraction as a partitioning method for hydrophobic organic chemicals in sediment and soot.

During the past few years, the presence of soot in sediments has received growing interest. Soot is thought to serve as a strong partitioning medium for specific organic contaminants (PAHs). The precise extent of sorption to this material, however, is poorly known because soot/water distribution coefficients for native PAHs have not been determined yet. Measuring these coefficients using existing partitioning methods is problematic due to the nature of soot. Therefore, the objective of this study was to develop a method for the determination of distribution coefficients for organic contaminants in soot/water (but also sediment/water) systems. The method is based on solid phase extraction (SPE) of chemicals onto the plastic polyoxymethylene (POM). Sorption experiments with POM showed monophasic sorption kinetics, linear isotherms covering several orders of magnitude, and a linear relationship between distribution coefficients for POM and the octanol/water distribution coefficient. Therefore, the sorption process can be considered to be true partitioning. Application of POM for the determination of distribution coefficients for soot and sediment (POM-SPE method) resulted in highly reproducible values. The method was validated by comparing values for sediment with results for the same sediment determined using the cosolvent method. This comparison resulted in an almost 1:1 relationship, proving the method's validity.

Adsorption↗

Analysis of oxazepam in urine using solid-phase extraction and high-performance liquid chromatography with fluorescence detection by post-column derivatization.

A reversed-phase high-performance liquid chromatographic method for oxazepam in human urine samples has been developed. The sample preparation consists of an enzymatic hydrolysis with beta-glucuronidase, followed by a solid-phase extraction process using Bond-Elut C2 cartridges. The mobile phase used was a methanol-water (60:40, v/v) mixture at a flow-rate of 0.50 ml/min. The column was a 3.5 cm x 4.6 mm I.D. C18 reversed-phase column. The detection system was based on a fluorescence post-column derivatization of oxazepam in mixtures of methanol and acetic acid. A linear range from 0.01 to 1 micrograms/ml of urine and a limit of detection of 4 ng/ml of urine were attained. Within-day recoveries and reproducibilities from urine samples spiked with 0.2 and 0.02 microgram/ml oxazepam were 97.9 and 95.0 and 2.1 and 9.4%, respectively.

Chromatography, High Pressure Liquid↗

Determination of cocaine, its metabolites, pyrolysis products, and ethanol adducts in postmortem fluids and tissues using Zymark automated solid-phase extraction and gas chromatography-mass spectrometry.

Demonstrating the presence or absence of cocaine (COC) and COC-related molecules in postmortem fluids and/or tissues can have serious legal consequences and may help determine the cause of impairment and/or death. We have developed a simple method for the simultaneous determination of COC and the COC metabolites benzoylecgonine (BE), norbenzoylecgonine (NBE), ecgonine methyl ester (EME), ecgonine (E), and norcocaine (NCOC), as well as anhydroecgonine methyl ester (AEME) (a unique byproduct of COC smoking), cocaethylene (a molecule formed by the concurrent use of COC and ethanol) and their related metabolites, anhydroecgonine (AE), norcocaethylene (NCE), and ecgonine ethyl ester (EEE). This method incorporates a Zymark RapidTrace automated solid-phase extraction (SPE) system, gas chromatography/mass spectrometry (GC/MS) and 2,2,3,3,3-pentafluoro-1-propanol (PFP)/pentafluoropropionic anhydride (PFPA) derivatives. The lower limits of detection ranged from 0.78 to 12.5 ng/mL and the linear dynamic range for most analytes was 0.78-3200 ng/mL. The extraction efficiencies were from 26 to 84% with the exception of anhydroecgonine and ecgonine, which were from 1 to 4%. We applied this method to five aviation fatalities. This method has proven to be simple, robust and accurate for the simultaneous determination of COC and 11 COC metabolites in postmortem fluids and tissues.

Automation↗

Simultaneous estimation of nicotine and cotinine levels in biological fluids using high-resolution capillary-column gas chromatography combined with solid phase extraction work-up.

A rapid and sensitive capillary gas-chromatographic method with nitrogen-sensitive detection is reported for the simultaneous analysis of nicotine and cotinine levels occurring in the plasma, saliva, and urine of regular tobacco smokers. The proposed assay has a linear output, has satisfactory accuracy over the range of concentrations of both amines encountered in active smokers, and has also been successful in the analysis of the urine samples of passive smokers. Its lower limit of sensitivity is 0.2 ng of nicotine and 0.5 ng of cotinine per ml of plasma or saliva or per 100 microliters of urine. The beneficial characteristics of the presented method were achieved by the combination of solid phase extraction of 0.1-1.0 ml of fluid specimens, capillary column gas chromatography with splitless injection and nitrogen sensitive detection, and the use of separate, structurally analogous compounds as internal standards for nicotine. The suitability of the assay is shown by plasma concentration-time curves of nicotine and cotinine in a steady smoker during a 24 hours period.

Chromatography, Gas↗

Determination of naringin and naringenin in human urine by high-performance liquid chromatography utilizing solid-phase extraction.

An HPLC method for determining a flavonoid naringin and its metabolite, naringenin, in human urine is presented for application to the pharmacokinetic study of naringin. Isocratic reversed-phase HPLC was employed for the quantitative analysis by using hesperidin for naringin or hesperetin for naringenin as internal standard and solid-phase extraction using a strong anion exchanger, Sep-Pak Accell QMA cartridge. The HPLC assay was carried out using an Inertsil ODS-2 column (250 x 4.6 mm I.D., 5 microm particle size). The mobile phases were acetonitrile-0.1 M ammonium acetate-acetic acid (18:81:1, v/v; pH 4.7) for naringin and acetonitrile-0.1 M ammonium acetate-triethylamine (25:75:0.05; v/v; pH 8.0) for naringenin. The flow-rate was 1.0 ml min(-1). The analyses were performed by monitoring the wavelength of maximum UV absorbance at 282 nm for naringin and at 324 nm for naringenin. The lower limits of quantification were ca. 25 ng/ml for naringin and naringenin with R.S.D. less than 10%. The lower limits of detection (defined as a signal-to-noise ratio of about 3) were approximately 5 ng for naringin and 1 ng for naringenin. A preliminary experiment to investigate the urinary excretion of naringin, naringenin and naringenin glucuronides after oral administration of 500 mg of naringin to a healthy volunteer demonstrated that the present method was suitable for determining naringin and naringenin in human urine.

Acetates↗

Data-dependent modulation of solid-phase extraction capillary electrophoresis for the analysis of complex peptide and phosphopeptide mixtures by tandem mass spectrometry: application to endothelial nitric oxide synthase.

Electrospray ionization (ESI) tandem mass spectrometry (MS/MS) of peptides in conjunction with automated sequence database searching of the resulting collision-induced dissociation (CID) spectra has become a powerful method for the identification of purified proteins or the components of protein mixtures. The success of the method is critically dependent on the manner by which the peptides are introduced into the mass spectrometer. In this report, we describe a capillary electrophoresis-based system for the automated, sensitive analysis of complex peptide mixtures. The system consists of an ESI-MS/MS instrument, a solid-phase extraction (SPE)-capillary zone electrophoresis (CZE) device for peptide concentration and separation, and an algorithm written in Instrument Control Language (ICL) which modulates the electrophoretic conditions in a data-dependent manner to optimize available time for the generation of high-quality CID spectra of peptides in complex samples. We demonstrate that the data-dependent modulation of the electric field significantly expands the analytical window for each peptide analyzed and that the sensitivity of the SPE-CZE technique is not noticeably altered by the procedure. By applying the technique to the analysis of in vivo phosphorylation sites of endothelial nitric oxide synthase (eNOS), we demonstrate the power of this system for the MS/MS analysis of minor peptide species in complex samples such as phosphopeptides generated by the proteolytic digestion of a large protein, eNOS, phosphorylated at low stoichiometry.

Amino Acid Sequence↗

Solid phase extraction and liquid chromatography-tandem mass spectrometry for the evaluation of 4-hydroxy-2-nonenal in pork products.

This research was aimed at setting up an analytical method for the determination in pork products of 4-hydroxy-2-nonenal (4-HNE), an aldehyde produced from the oxidation of omega-6-polyunsaturated fatty acids. Such a compound mediates various biological effects, but it is considered to be very toxic to mammalian cells at levels higher than physiological ones. The methods used for the determination of 4-HNE in biological fluids, such as blood, were found to be unsuitable for meat samples because both the repeatability and the recovery in spiked samples were unsatisfactory. A new method, based on solid phase extraction and HPLC-MS/MS, was therefore developed and validated. The limit of detection of 4-HNE in spiked samples was 0.043 mg/kg, and the recovery was approximately 60% depending on the concentration. Good linearity was observed in the range of 0.1-10 mg/kg, and repeatability and interday and intraday precision expressed as relative standard deviation were <10%. The method has been successfully applied to the determination of the aldehyde in samples of various pork products. 4-HNE was present in some products, especially the smoked and/or cooked ones, at levels that might not be a real risk for human health.

Aldehydes↗

Novel chromatographic separation and carbon solid-phase extraction of acetanilide herbicide degradation products.

One acetamide and 5 acetanilide herbicides are currently registered for use in the United States. Over the past several years, ethanesulfonic acid (ESA) and oxanilic acid (OA) degradation products of these acetanilide/acetamide herbicides have been found in U.S. ground waters and surface waters. Alachlor ESA and other acetanilide degradation products are listed on the U.S. Environmental Protection Agency's (EPA) 1998 Drinking Water Contaminant Candidate List. Consequently, EPA is interested in obtaining national occurrence data for these contaminants in drinking water. EPA currently does not have a method for determining these acetanilide degradation products in drinking water; therefore, a research method is being developed using liquid chromatography/negative ion electrospray/mass spectrometry with solid-phase extraction (SPE). A novel chromatographic separation of the acetochlor/alachlor ESA and OA structural isomers was developed which uses an ammonium acetate-methanol gradient combined with heating the analytical column to 70 degrees C. Twelve acetanilide degradates were extracted by SPE from 100 mL water samples using carbon cartridges with mean recoveries >90% and relative standard deviations < or =16%.

Acetanilides↗

Determination of phenolic derivatives of antipyrine in plasma with solid-phase extraction and high-performance liquid chromatography-atmospheric-pressure chemical ionization mass spectrometry.

This manuscript describes a method to determine antipyrine and its phenolic derivatives in plasma by reversed-phase high-performance liquid chromatography-mass spectrometry (RP-HPLC-MS). The sample pretreatment consisted of a C18 solid-phase extraction (SPE), to remove the salts and proteins. The retention behavior of antipyrine and its phenolic derivatives in the SPE procedure was estimated by the k values determined on a C18 HPLC column at different pH values and with different buffer compositions. Recoveries of antipyrine and its phenolic products were 90% in water and 100% in plasma. Atmospheric pressure chemical ionization (APCI) was used to introduce the components into the mass spectrometer. The mass spectrometer was operated in the single ion monitoring mode (SIM mode) as well as in the selective reaction (SR) mode. The SR mode or tandem MS resulted in the best signal-to-noise ratio, with a detection limit for antipyrine of 6 pg in 20 microl. For the different phenolic antipyrines, different target ions were used and conditions were optimized for each.

Antipyrine↗

Determination of tramadol in hair using solid phase extraction and GC-MS.

Tramadol is a centrally acting synthetic analgesic with mu-opioid receptor agonist activity, it is a widely prescribed analgesic used in the treatment of moderate to severe pain and as an alternative to opiates. Tramadol causes less respiratory depression than morphine at recommended doses. Its efficacy and low incidence of side effects lead to its unnecessary prescribing in patients with mild pain. Tramadol was classified as a "controlled drug" long after its approval for use in Jordan. Analysis of drugs of abuse in hair has been used in routine forensic toxicology as an alternative to blood in studying addiction history of drug abusers. A method for the determination of tramadol in hair using solid phase extraction and gas chromatography-mass spectrometry (GC-MS) is presented, the method offers excellent precision (3.5-9.8%, (M)=6.77%), accuracy (6.9-12%, M=9.4%) and limit of detection 0.5 ng/mg. The recovery was in the range of 87-94.3% with an average of 90.75%. The calibration curve was linear over the concentration range 0.5-5.0 ng/mg hair with correlation coefficient of 0.998. The developed method was tested on 11 hair samples taken from patients using tramadol as prescribed by their physician along with other different drugs in treating chronic illnesses. Tramadol was detected in all hair samples at a concentration of 0.176-16.3 ng/mg with mean concentration of 4.41 ng/mg. The developed method has the potential of being applied in forensic drug hair testing. In Jordan, hair drug testing started to draw the attention of legal authorities which stimulated forensic toxicologists in recent years to develop methods of analysis of drugs known or have the potential to be abused.

Adult↗

Combination of cationic surfactant-assisted solid-phase extraction with field-amplified sample stacking for highly sensitive analysis of chlorinated acid herbicides by capillary zone electrophoresis.

This report describes a novel online field-amplified sample stacking (FASS) procedure to analyze 16 chlorinated acid herbicides. By using a poly(vinyl alcohol) (PVA)-coated capillary to reduce electroosmotic flow and introducing a methanol-water plug before sample loading, the sample injection time could be very long without loss of sample and separation efficiency. Under the optimized condition, the FASS procedure could provide great sensitivity enhancement (5000-10 000-fold) and satisfactory reproducibility (relative standard deviations of migration times less than 2.4%, relative standard deviations of peak areas less than 8.0%). Combined with cationic surfactant-assisted solid-phase extraction (CSA-SPE), the limit of detection of the herbicides ranged from 0.269 to 20.3 ppt, which are two orders lower than those of the US Environmental Protection Agency standard method 515.1. The CSA-SPE-FASS-CE method was successfully applied to the analysis of local pond water.

2-Hydroxypropyl-beta-cyclodextrin↗

Solid-phase extraction of room-temperature imidazolium ionic liquids from aqueous environmental samples.

Owing to their favorable properties, ionic liquids have recently gained recognition as possibly environmentally benign solvents. Now among the most promising industrial chemicals, they have already been labeled "green", but this appellation seems due entirely to their very low vapor pressure. This growing interest in the various applications of ionic liquids will soon result in their presence in the environment. Therefore, reliable analytical tools for the environmental analysis of ionic liquids need to be developed urgently. This paper presents a newly developed analytical procedure for the enrichment of 1-alkyl- and 1-aryl-3-methylimidazolium ionic liquids from water samples. The method is based on cation exchange solid-phase extraction followed by selective elution. Pre-concentrated samples are subjected to high-performance liquid chromatography (HPLC) with an advanced methodology for qualitative and quantitative analysis. The overall procedure was verified by using standard spiked samples of tap water, seawater, and freshwater.

Journal Article↗

Comparison of ultrafiltration and solid phase extraction for the separation of free and protein-bound serum copper for the Wilson's disease diagnosis.

BACKGROUND: The determination of the ratio free/protein-bound serum copper along with urinary copper can be used as a preliminary test for the Wilson's Disease diagnosis. In this work, the determination of these copper fractions in serum samples was carried out in two different ways; after separation of the copper bound to proteins from the free fraction by a column for protein adsorption and by ultrafiltration. As proteins can be adsorbed onto plastic polymeric surfaces, polyethylene (PE) with different molecular weights in powder form was investigated for protein adsorption. A small column was adapted in a flow system to carry out a solid-phase extraction (SPE) on-line. Preliminary experiments defined conditions for protein retention and elution and column saturation. Good performance was achieved using Mg(NO3)2 solution as carrier and methanol as eluent. The presence of proteins in both fraction (column effluent and eluate) was checked by the Coomassie Brilliant Blue test. Copper was measured by graphite furnace atomic absorption spectrometry. The measurement in the column effluent furnished the free-fraction of copper while the copper measured in the eluate the bound-fraction. The method was compared with ultrafiltration (20 kDa), measuring the free-copper in the ultrafiltrate. For the determination of protein-bound copper, the copper found in the ultrafitrate was discounted from the total copper measured in the sample. RESULTS: Serum samples of 10 individuals were analyzed by both methods with good agreement of the results. The regression plots, obtained by analysing the samples by both methods, presented r2 and slope of 0.97 and 0.96 for free copper and 1.00 and 1.00 for bound copper, respectively. Protein-bound copper (PB) concentrations ranged from 74 to 2074 microg/l and free-copper (F) from 22 to 54 microg/l. The ratio F/PB, calculated from SPE data, was 29.7% for one individual, with Wilson Disease well-characterized, and ranged from 1.2% to 5.2% for the others. CONCLUSION: The SPE method performed well in terms of accuracy and precision, and showed good agreement with the UF. Advantages of SPE are small sample volume (50 microl), separation carried out in 10 min, and the use of the same column for several analyses.

Blood Proteins↗

Simple and selective spectrophotometric determination of ruthenium after solid phase extraction with some quinoxaline dyes into microcrystalline p-dichlorobenzene.

A simple selective and highly sensitive extraction method has been developed for the determination of ruthenium spectrophotometrically after extraction of its 2,3-dichloro-6-(3-carboxy-2-hydroxy-1-naphthylazo)quinoxaline (I), 2,3-dichloro-6-(2-hydroxy-3,5-dinitrophenylazo)quinoxaline (II) and 2,3-dichloro-6-(2,7-dihydroxy-naphthylazo)quinoxaline (III) complexes into microcrystalline p-dichlorobenzene. The optimization of experimental conditions for the procedure is studied. The solid p-dichlorobenzene containing the ruthenium-reagent (I-III) complexes is separated by filtration and dissolved in N,N-dimethylformamide. The absorbance is measured at lambda(max) 622, 518 and 542 nm against reagents I, II and III, respectively, as blank. Beer's law is obeyed upto 2.5 microg ml(-1) of ruthenium. The molar absorptivity, Sandell sensitivity, detection and quantification limits are calculated, when compared with those parameters without using solid phase extraction method. The interference of various ions has been studied in detail and the statistical evaluation of the experimental results is reported. The proposed methods have been successfully applied for the determination of trace amount of ruthenium in seawater, ore and metallurgy products.

Chlorobenzenes↗