Two-step navigatorless correction algorithm for radial k-space MRI acquisitions.

A new way to correct magnetic resonance image artifacts resulting from view-dependent phase variations and view-dependent variations in rigid body object translation is presented by exploiting basic properties of the trajectory of radial k-space acquisitions. Simulations, phantom studies, and in vivo experiments are used to demonstrate the feasibility and the utility of this method. While somewhat analogous to navigator echo correction, in which special gradients are interleaved into the imaging sequence so echoes at the center of k-space can be acquired prior to or after collection of the image data, the current method does not require additional new gradient structures within the pulse sequence or increases in scan time. The new method uses the phase information from all collected radial k-space data points rather than only the navigator echo, which permits correction of multiple sources of view-dependent phase variation in the image data. The resultant effect is improved image quality in radial MRI acquisitions. Magn Reson Med 45:277-288, 2001.

Algorithms↗

Dead-time free measurement of dipole-dipole interactions between electron spins.

A four-pulse version of the pulse double electron-electron resonance (DEER) experiment is presented, which is designed for the determination of interradical distances on a nanoscopic length-scale. With the new pulse sequence electron-electron couplings can be studied without dead-time artifacts, so that even broad distributions of electron-electron distances can be characterized. A version of the experiment that uses a pulse train in the detection period exhibits improved signal-to-noise ratio. Tests on two nitroxide biradicals with known length indicate that the accessible range of distances extends from about 1.5 to 8 nm. The four-pulse DEER spectra of an ionic spin probe in an ionomer exhibit features due to probe molecules situated both on the same and on different ion clusters. The former feature provides information on the cluster size and is inaccessible with previous methods.

Electron Spin Resonance Spectroscopy↗

Lesion load quantification on fast-FLAIR, rapid acquisition relaxation-enhanced, and gradient spin echo brain MRI scans from multiple sclerosis patients.

Previous studies have addressed the issue of the usefullness of fast fluid-attenuated (fast-FLAIR), rapid acquisition relaxation-enhanced (RARE), and gradient spin echo (GRASE) sequences in small groups of patients with multiple sclerosis (MS). The aim of this study was to assess and compare the lesion volumes and the intra-rater reproducibility of such measurements using fast-FLAIR, dual echo RARE, and dual echo GRASE brain scans from a large sample of MS patients. Using a 1.5 Tesla scanner, fast-FLAIR, dual echo RARE, and dual echo GRASE scans (24 axial, 5-mm thick contiguous interleaved slices) of the brain were obtained from 50 MS patients. Total lesion loads (TLL) were assessed twice using a semi-automated local thresholding segmentation technique by the same rater from the scans obtained with the three techniques. Mean TLL were 20.3 mL for fast-FLAIR, 16.6 mL for RARE, and 17.6 mL for GRASE sequences. Mean TLL detected by the three techniques were significantly heterogeneous (p < 0.001); at post-hoc analysis, the mean lesion volume detected on fast-FLAIR images was significantly higher than that on both RARE and GRASE images (p < 0.001) and the mean TLL on GRASE scans was significantly higher than that on RARE scans (p = 0.001). The mean values of intra-observer coefficient of variation for TLL measurements were similar for the three techniques (2.69% for fast-FLAIR, 2.33% for RARE, and 2.65% for GRASE). Our results confirm that fast-FLAIR sequences detect higher lesion volumes than those detected by other magnetic resonance imaging (MRI) sequences with shorter acquisition times. However, the reproducibility of TLL measurements is comparable among fast-FLAIR, RARE, and GRASE. This suggests that when assessing MS disease burden with MRI, the choice of the pulse sequence to be used should be dictated by the clinical setting.

Adult↗

Functional magnetic resonance imaging of schizophrenic patients and comparison subjects during word production.

OBJECTIVE: This study was undertaken to test the feasibility of using functional magnetic resonance imaging (MRI) to examine changes in cortical activation in response to verbal tasks in two brain regions. METHOD: Twelve schizophrenic patients and 11 comparison subjects underwent functional MRI of the frontal and temporal lobes. Stimulus sequences were divided into five 30-second segments by using a task-activation paradigm that alternated between resting and stimulated states. Functional images were collected every 30 seconds by using a gradient echo pulse sequence. RESULTS: Schizophrenic subjects demonstrated significantly less left frontal activation and greater left temporal activation than comparison subjects during a word fluency task. CONCLUSIONS: These preliminary data suggest that functional MRI has the sensitivity to detect differences in activation between comparison subjects and schizophrenic patients during higher cortical functions. These findings are in agreement with PET studies that reported reduced left frontal activation during challenge paradigms for the schizophrenic patients.

Adult↗

MR cholangiopancreatography of pancreaticobiliary diseases: comparing single-shot RARE and multislice HASTE sequences.

OBJECTIVE: In this study, we compared the single-shot rapid acquisition with relaxation enhancement (RARE) sequence with the multislice half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence to assess the ability of each technique to show various pancreaticobiliary diseases using MR cholangiopancreatography. SUBJECTS AND METHODS: MR cholangiopancreatography was performed using both the single-shot RARE and the multislice HASTE pulse sequences in 80 consecutive subjects in whom we had proof of a range of diagnoses. The study population included healthy subjects (n = 9), patients with benign lesions (n = 41), and patients with malignant lesions (n = 30). We analyzed each image using the following criteria: the cause of the lesions, the image quality (i.e., the amount of artifact and the sharpness of anatomic structures such as the right and left hepatic ducts, the extrahepatic bile duct, and the main pancreatic duct), and the reviewers' preference of images. The images were evaluated independently by two radiologists who were unaware of the results of the other cholangiopancreatographic sequence and of the diagnosis. RESULTS: Artifacts were less prominent in images that were obtained using the single-shot RARE sequence (p = .0192); however, the sharpness of anatomic structures was the same using either sequence (p = .1673). For images that were obtained using the single-shot RARE technique, the sensitivity, specificity, and accuracy in distinguishing malignant from other abnormalities were 83%, 78%, and 80%, respectively; for the multislice HASTE technique, these values were 77%, 72%, and 74%, respectively (p > .05). Disease-specific accuracy in determining the correct diagnosis was 54% and 59%, respectively (p > .05). In patients in whom all the ducts needed to be defined, the single-shot RARE technique was preferred to the multislice HASTE technique (p < .01). CONCLUSION: The single-shot RARE technique shows fewer artifacts and is preferred to the multislice HASTE technique. However, both techniques show the same degree of sharpness of anatomic structures, both are able to reveal malignant diseases, and both provide enough information to determine a specific diagnosis.

Adult↗

MR imaging of focal lung lesions: elimination of flow and motion artifact by breath-hold ECG-gated and black-blood techniques on T2-weighted turbo SE and STIR sequences.

Respiratory and cardiac motion correction may result in better turbo spin-echo (SE) imaging of the lung. To compare breath-hold cardiac-gated black-blood T2-weighted turbo SE and turbo short-inversion-time inversion-recovery (STIR) magnetic resonance (MR) imaging pulse sequences with conventional breath-hold turbo SE and half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences for lesion conspicuity of focal lung lesions, 42 patients with focal lung lesions were prospectively studied with MR imaging at 1.5 T. Helical computed tomography was used as a reference. In comparison with the conventional breath-hold turbo SE sequence, all black-blood sequences had fewer image artifacts arising from the heart and blood flow. The overall image quality for the black-blood turbo SE and turbo STIR sequences was superior to that for the breath-hold turbo SE and HASTE sequence (P < 0.01). Not only focal lung lesions but also surrounding inflammatory changes were clearly visualized with these two sequences. With the HASTE sequence, although several slices could be obtained in one breath-hold, both the tumor and vessels appeared blurred. We conclude that T2-weighted turbo SE and turbo STIR imaging of the lung with effective suppression of flow and motion artifacts provide high-quality images in patients with focal lung lesions.

Artifacts↗

Dynamic nuclear polarization in pulsed ENDOR experiments.

Properly prepared pulse sequences of microwave and radio frequency have been employed to investigate the effect of polarization transfer from the polarized photo excited triplet state of pentacene in p-terphenyl crystals to the surrounding protons in pulsed ENDOR experiments. The ENDOR signal, measured as the change of electron spin echo (ESE) amplitude, is affected by the mode of RF pulses. When B0 parallelx (the long molecular axis), the ESE amplitude of the high-field transition of the triplet state changes from the maximum positive to zero with a pi RF pulse, and to the maximum negative with a 2pi pulse, while that of the low-field transition changes from nearly zero to the maximum negative as the RF pulse width increases. The effect is attributed to the strong electron spin polarization produced in the creation of the photoexcited triplet state and the subsequent efficient electron- nuclear polarization transfer process.

Magnetic Resonance Spectroscopy↗

A modified PGSE for measuring diffusion in the presence of static magnetic field gradients.

With a proper timing of pi pulses, it is possible to reduce the effect of the static internal magnetic field gradient on the measurement of diffusion with the pulsed gradient spin echo (PGSE). A pulse sequence that in the first order eliminates the effect of weak internal static gradients in a standard PGSE experiment is introduced. The method should be applied in the cases, where strong and short magnetic gradient pulses are used to investigate the motion of liquid in heterogeneous samples with large susceptibility differences such as porous media.

Journal Article↗

[Rationale and limits of echo planar magnetic resonance imaging].

INTRODUCTION: The use of Echo Planar Imaging (EPI) techniques has extensively increased in the last few years. The technical improvements in new Magnetic Resonance Imaging (MRI) systems satisfy the instrumental requirements for these complex high-speed methods. The latest commercial systems are provided with standard EPI sequences. The increased data acquisition speed which characterizes EPI opens new and interesting perspectives, although the resolution is lower than the one typically achieved with conventional imaging. MATERIALS AND METHODS: The description of the data sampling process in terms of the k-space is a powerful tool for planning or understanding complex sequence diagrams like EPI. The basic concepts of the method are reported and discussed, pointing out the most noteworthy feature of the k-space, i.e., its Fourier inverse yield to the image. A generic pulse sequence has been considered to explain the sampling of k-space trajectories. Examples of ultrafast imaging techniques are subsequently considered and discussed. CONCLUSIONS: EPI improves the resolution time of MRI, which is an intrinsically slow imaging procedure. Images can be obtained in few tenth of a second so that MRI suits the short temporal range of many interesting physiological processes. Recently the main goal of functional Magnetic Resonance Imaging (fMRI) has been the study of brain activity related to local changes in brain hemodynamics. These changes cause MR signal intensity variations. In the last years, several brain activity studies have been performed by means of Positron Emission Tomography (PET) which involves the administration of radioactive substances; fMRI has the advantage that it is a noninvasive technique, although peripheral nerve stimulation effects should be considered.

Humans↗

Coronary MR angiography.

The principles underlying coronary MR angiographic pulse sequences are reviewed, including basic coronary anatomy, motion, and flow physiology. Coronary MR angiographic techniques can be subdivided into breath-hold (single or repeated) and nonbreath-hold techniques. The recent introduction of navigator pulses for real-time respiratory gating or triggering allows nonbreath-hold or repeated breath-hold 3-D coronary MR angiography, and will allow a more widespread use of this technique.

Coronary Circulation↗

Effect of Gd-DTPA-BMA on magnetization transfer: application to rapid imaging of cardiac ischemia.

The addition of a paramagnetic contrast agent reduces the magnetization transfer effect between the free and restricted proton pools in both agar phantoms and cardiac muscle tissue. This reduction is due to the reduction in the intrinsic T1 of the free proton pool and increases the signal observed after a given magnetization transfer sequence. Images of ex vivo piglet hearts were obtained with a segmented snapshot FLASH (fast low-angle shot) sequence with a 128 x 128 matrix, four segments, and two signals averaged, resulting in an imaging time of 7 seconds. Magnetization transfer was induced by applying a DANTE (delays alternating with nutations for tailored excitations) pulse sequence in the intersegment interval. This was an efficient method of inducing magnetization transfer because it excites the restricted proton pool across the full frequency spectrum. Ischemia due to occlusion of the left anterior descending branch of the coronary artery could be visualized after infusion of gadolinium diethylenetriaminepentaacetic acid-bis(methylamide) (DTPA-BMA). Although the ischemia could be seen with the basic sequence, the contrast between ischemic and non-ischemic tissue improved when the magnetization transfer sequence was included. The most marked improvements in magnetization transfer were achieved with low doses of Gd-DTPA-BMA.

Animals↗

31P spectroscopic localization using pinwheel NMR excitation pulses.

Spectroscopic imaging with a one-dimensional phase-encoding gradient and surface-coil reception relies on the restricted range of sensitivity of the surface coil to provide localization in the dimensions transverse to the coil axis and consequently suffers from relatively poor localization in these dimensions. A two-dimensional (2D) cylindrically selective excitation pulse with a large spectral bandwidth is presented here to remedy this problem. The gradient waveforms are derived from multiple spirals in k space which form an overall pinwheel pattern, resulting in a pulse which is much shorter than the equivalent single-spiral trajectory. Nonuniform traversal of the spirals further reduces the pulse width under conditions of gradient slew-rate limitations, yielding overall gains in bandwidth of up to about 30 compared with the equivalent single-spiral trajectory traversed at constant angular rate. The accompanying rf waveform is obtained by weighted 2D Fourier transformation of the desired sensitivity profile. A new weighting factor is introduced into the rf waveform to compensate for nonuniform sampling of k space by the pinwheel near the origin. This factor is independent of the weighting used to account for the rate of traversal of the trajectory and is applicable to 2D pulse design in general. Pulse sequences employing pinwheel excitation in conjunction with either phase-encoding or slice-selective inversion are used to produce multiple-voxel and single-voxel localization in a human heart and a phantom. Pinwheel pulses may be used to advantage on moieties with long spin-lattice relaxation times and short transverse relaxation times and are therefore ideal for applications in phosphorus (31P) NMR.

Heart↗

MR imaging of hemorrhagic adnexal masses.

Magnetic resonance (MR) imaging, performed on 31 women with 40 surgically proven adnexal masses, was reviewed to determine whether MR can distinguish hemorrhagic from nonhemorrhagic masses. Fourteen masses proved to be hemorrhagic at surgery including functional ovarian cysts (seven cases), cystadenoma (one case), endometriomas (three cases), hematosalpinx (one case), ectopic pregnancy (one case), and parametrial extension from cervical carcinoma (one case). A high signal intensity (compared with adjacent pelvic fat) on a T1-weighted spin echo sequence was found to be a reliable indicator of hemorrhage and was demonstrated in all 14 hemorrhagic masses. The "hematocrit" effect was seen as an area of high signal intensity layering in the dependent portion of six hemorrhagic cysts. Only four of 26 nonhemorrhagic masses demonstrated high signal intensity on T1-weighted sequences and, of these, three proved to be fat-containing dermoid cysts and one was a simple cyst with adherent mesenteric fat. We conclude that high signal intensity on a T1-weighted spin echo pulse sequence is evidence for a hemorrhagic mass and that a hematocrit effect appears to be a specific sign for a hemorrhagic cyst. The clinical significance of hemorrhagic adnexal masses is discussed.

Adnexal Diseases↗

Comprehensive encoding and decoupling solution to problems of decoherence and design in solid-state quantum computing.

Proposals for scalable quantum computing devices suffer not only from decoherence due to the interaction with their environment, but also from severe engineering constraints. Here we introduce a practical solution to these major concerns, addressing solid-state proposals in particular. Decoherence is first reduced by encoding a logical qubit into two qubits, then completely eliminated by an efficient set of decoupling pulse sequences. The same encoding removes the need for single-qubit operations, which pose a difficult design constraint. We further show how the dominant decoherence processes can be identified empirically, in order to optimize the decoupling pulses.

Journal Article↗

Accurate measurement of 15N-13C residual dipolar couplings in nucleic acids.

New 3D HCN quantitative J (QJ) pulse schemes are presented for the precise and accurate measurement of one-bond 15N1/9-13C1', 15N1/9-13C6/8, and 15N1/9-13C2/4 residual dipolar couplings (RDCs) in weakly aligned nucleic acids. The methods employ 1H-13C multiple quantum (MQ) coherence or TROSY-type pulse sequences for optimal resolution and sensitivity. RDCs are obtained from the intensity ratio of H1'-C1'-N1/9 (MQ-HCN-QJ) or H6/8-C6/8-N1/9 (TROSY-HCN-QJ) correlations in two interleaved 3D NMR spectra, with dephasing intervals of zero (reference spectrum) and approximately 1/(2J(NC)) (attenuated spectrum). The different types of 15N-13C couplings can be obtained by using either the 3D MQ-HCN-QJ or TROSY-HCN-QJ pulse scheme, with the appropriate setting of the duration of the constant-time 15N evolution period and the offset of two frequency-selective 13C pulses. The methods are demonstrated for a uniformly 13C, 15N-enriched 24-nucleotide stem-loop RNA sequence, helix-35psi, aligned in the magnetic field using phage Pf1. For measurements of RDCs systematic errors are found to be negligible, and experiments performed on a 1.5 mM helix-35psi sample result in an estimated precision of ca. 0.07 Hz for 1D(NC), indicating the utility of the measured RDCs in structure validation and refinement. Indeed, for a complete set of 15N1/9-13C1', 15N1/9-13C6/8, and 15N1/9-13C2/4 dipolar couplings obtained for the stem nucleotides, the measured RDCs are in excellent agreement with those predicted for an NMR structure of helix-35psi, refined using independently measured observables, including 13C-1H, 13C-13C and 1H-1H dipolar couplings.

Adenine↗

Application of amplitude-modulated radiofrequency fields to the magic-angle spinning NMR of spin-7/2 nuclei.

We report pulse sequences for the sensitivity enhancement of magic-angle spinning and multiple-quantum magic-angle spinning spectra of spin-72 systems. Sensitivity enhancement is obtained with the use of fast amplitude-modulated (FAM) radiofrequency pulses. In one-dimensional magic-angle spinning experiments, signal enhancement of 3 is obtained by a FAM pulse followed by a soft 90 degrees pulse. In two-dimensional multiple-quantum magic-angle spinning experiments, FAM pulses are used for both the excitation of multiple-quantum coherences and for their conversion into observable single-quantum coherences. The observed signal enhancements are 2.2 in 3Q experiments, 3.1 in 5Q experiments, and 4.1 in 7Q experiments, compared to the conventional two-pulse scheme. The pulse schemes are demonstrated on the 45Sc NMR of Sc2(SO4)3 x 5H2O and the 139La NMR of LaAlO3. We also demonstrate the generation of FAM pulses by double-frequency irradiation.

Journal Article↗

Selective measurement of white matter and gray matter diffusion trace values in normal human brain.

The trace of the diffusion tensor (or simply the trace) is diagnostically valuable for detecting acute ischemic lesions. A number of studies indicate that the trace of human gray matter (GM) and white matter (WM) are quite similar. This is somewhat surprising considering the different cellular environments of GM and WM. It is possible that partial volume averaging (PVA) effects between GM and WM, inherent in many of the ultrafast imaging sequences used for diffusion measurements, are responsible for this observation. In order to minimize PVA effects, the trace values of GM and WM have been selectively measured by implementing double inversion recovery (DIR) echo planar imaging (EPI) pulse sequences. Results on six normal volunteers indicate that the trace values of WM and GM are not statistically different.

Adult↗

Numerical simulation of PRESS localized MR spectroscopy.

Numerical simulations of NMR spectra can provide a rapid and convenient method for optimizing acquisition sequence parameters and generating prior spectral information required for parametric spectral analysis. For spatially resolved spectroscopy, spatially dependent variables affect the resultant spectral amplitudes and phases, which must therefore be taken into account in any spectral simulation model. In this study, methods for numerical simulation of spectra obtained using the PRESS localization pulse sequence are examined. A comparison is made between three different simulation models that include different levels of detail regarding the spatial distributions of the excitation functions, and spin evolution during application of the pulses. These methods were evaluated for measurement of spectra from J-coupled spin systems that are of interest for in vivo proton spectroscopy and results compared with experimental data. It is demonstrated that for optimized refocusing pulses it is sufficient to account for chemical shift effects only, although there is some advantage to implementing a more general numerical simulation approach that includes information on RF pulse excitation profiles, which provides sufficient accuracy while maintaining moderate computational requirements and flexibility to handle different spin systems.

Aspartic Acid↗