Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PATENTS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81Linked to original sources

A guideline to the management of patent ductus arteriosus in infants and children.

Experience with multiple ligation of the patent ductus arteriosus (PDA) at the Hospital for Sick Children, Great Ormond Street, London, is presented. One hundred and sixty-one consecutive cases between January 1971 and December 1974 have been reviewed. Fifty-four children (33%) were less than one year of age. In the majority of cases the diagnosis was made on clinical grounds. Cardiac catheterization and angiography were carried out when associated intracardiac lesions were suspected. The overall mortality was 2.5%. All the deaths occurred in infants less than six months of age who had associated cardiac lesions. There were no deaths in patients who had an uncomplicated PDA or who were more than one year of age. Multiple ligation of the PDA is a simple and safe operation. The risk of operative treatment is affected more by the presence of associated cardiac lesions and the age of the patient than by the surgical technique employed.

Cardiac Catheterization↗

Patent ductus arteriosus in Malaysia.

Findings are reviewed of isolated Patent Ductus Arteriosus after infancy as seen in 181 patients studied at the University Hospital, Kuala Lumpur, during the period 1967 to 1975. The ages of patients ranged from nine months to 54 years. Eighty-two patients underwent cardiac catheterization. More than 50% of patients were above ten years of age; the sex ratio was 1 male: 2.93 females. Thirty-two per cent of the patients had significant effort dyspnoea or were in heart failure. The complications noted were elevated pulmonary vascular resistance, Eisenmenger syndrome, bacterial endocarditis and cardiac failure.

Adolescent↗

Patent ductus arteriosus and cerebral circulation in preterm infants.

The diagnosis of patent ductus arteriosus (PDA) was determined by Doppler examinations of the descending aorta and/or main trunk of the pulmonary artery in a cohort of 120 preterm infants. 55 per cent of the infants had Doppler echocardiographic evidence of ductal patency on the first day of life and this proportion fell to 30 per cent on the second day and 21 per cent on the third day. The incidence remained constant for the rest of the first week. Infants with PDA were significantly more likely to develop periventricular leukomalacia (PVL) than infants without PDA, but the incidence of periventricular haemorrhage was not increased. The cerebral haemodynamic effects of ductal patency were evaluated. Infants with PVL were found to have a significantly higher incidence of retrograde flow in the anterior cerebral artery during diastole, but the study was unable to demonstrate any significant difference in cerebral blood flow velocity between the infants with and without PDA.

Blood Flow Velocity↗

Efficacy and renal tolerability of ibuprofen vs. indomethacin in preterm infants with patent ductus arteriosus.

Indomethacin is commonly used for the treatment of patent ductus arteriosus (PDA) but has renal failure as a main side-effect. Ibuprofen seems to be efficient in closing the ductus with less side-effects, but few studies are available in literature as regards its use in preterm infants. This study is a retrospective analysis of clinical data in order to compare the efficacy and the renal tolerability of ibuprofen and indomethacin administered to preterm infants with gestational age (GA) < or = 30 weeks for the treatment of PDA. From our data, ibuprofen results pharmacologically as efficient as indomethacin and could be an alternative in prematures. About renal tolerability, our data confirm that non-steroidal anti-inflammatory drugs treatment could affect at least transiently renal function. Moreover, indomethacin could be more nephrotoxic compared with ibuprofen, as creatinine concentrations normalize more slowly in this group, although the mean difference between the two drugs was not significant as our population sample was small. Further studies are needed to assess whether ibuprofen is really less nephrotoxic than indomethacin, in particular by examining carefully the correlation between GA and ibuprofen administration.

Adult↗

Patent ductus arteriosus in old age.

An unusual case of patient ductus arteriosus (PDA) in a 78-year-old man is presented. The patient was known to have PDA since the age of 30, but it had remained well compensated until shortly before death. He had undergone some difficult operations successfully, and had no specific pulmonary complaints. Death at age 78 was caused by arteriosclerotic heart disease following myocardial infarction. Autopsy revealed a smooth patent ductus arteriosus with no perforation. The survival of a PDA patient to such advanced age is a comparatively rare occurrence.

Aged↗

Minimally invasive patent ductus arteriosus occlusion in 5 dogs.

OBJECTIVE: To report a technique for minimally invasive occlusion of patent ductus arteriosus (PDA) and outcome in 5 dogs. STUDY DESIGN: Clinical cases. ANIMALS: Five, 4-6-month-old, dogs with PDA. MATERIALS AND METHODS: Titanium ligating clips were used for PDA closure in all dogs. Three dogs had video-enhanced mini-thoracotomy PDA occlusion. Two other dogs had thoracoscopic PDA occlusion using a custom-designed thoracoscopy clip applicator. RESULTS: Thoracoscopic PDA occlusion was successful in both dogs in which it was attempted. Complete PDA closure was achieved in 4 dogs. Three months after surgery, the largest dog had residual ductal flow that hemodynamically was insignificant. CONCLUSIONS: Although technically demanding, minimally invasive PDA occlusion is a safe and reliable technique in dogs. Preoperative measurement of the diameter of the PDA is crucial to determine if complete closure with metal clips can be achieved. CLINICAL RELEVANCE: Minimally invasive PDA occlusion should be considered as an alternative to occlusion via conventional thoracotomy.

Animals↗

Coil occlusion of residual shunts after surgical closure of patent ductus arteriosus.

UNLABELLED: OBJECTIVE; To describe use of coil embolization to occlude residual flow through a patent ductus arteriosus (PDA) after incomplete surgical ligation. STUDY DESIGN: Clinical study. ANIMALS: Dogs (n=4) with continuous murmur after surgical ligation of PDA. METHODS: After PDA ligation, residual ductal flow through the PDA was visible on color-flow Doppler examination and left ventricular end-diastolic diameter remained increased. Coil embolization by an arterial approach was performed to achieve complete occlusion of the PDA. RESULTS: Embolization coils were delivered without complications and hemodynamically successful occlusion was achieved. Doppler-visible flow resolved in 2 dogs within 3 months after embolization. Left ventricular end-diastolic diameter indexed to body weight decreased in all dogs. CONCLUSIONS: Transcatheter coil embolization appears to be a safe and minimally invasive procedure for complete occlusion of residual PDA flow after incomplete surgical ligation. CLINICAL RELEVANCE: Transcatheter coil embolization should be considered for correction of hemodynamically significant residual shunts in dogs that have incomplete PDA occlusion after open surgical ligation.

Animals↗

Retrospective comparison of surgical ligation and transarterial catheter occlusion for treatment of patent ductus arteriosus in two hundred and four dogs (1993-2003).

OBJECTIVE: To compare procedure time, complications, mortality, and short-term outcome in dogs with patent ductus arteriosus (PDA) treated by surgical ligation (SL) or transarterial coil occlusion (TCO). STUDY DESIGN: Retrospective study. ANIMALS: Dogs with PDA (n=204). METHODS: Medical records of dogs treated for PDA were reviewed. Dogs treated by SL when it was the primary method used for PDA treatment (1993-1998) were compared with dogs treated by TCO when it was the primary method used for PDA treatment (1999-2003). Dogs treated during the transition between techniques, dogs treated with SL (1999-2003) and dogs treated with TCO before 1999, as well as dogs with pulmonary hypertension, or bidirectional or reversed (right-to-left) flow through the PDA were excluded from analysis. RESULTS: Age, weight, gender distribution, and procedure times (P=.43) were similar for both groups. Major complications were more common with SL (12% versus 4.3%; P=.035) whereas minor complications were more common with TCO (12% versus 26%; P=.015). Initial success rate was higher for SL (94%) compared with TCO (84%; P=.027). There was no significant difference in mortality between SL (5.6%) and TCO (2.6%; P=.27). CONCLUSIONS: Both SL and TCO are acceptable PDA treatments with comparable mortality; however, SL was associated with a higher risk of major complications and TCO was associated with a lower initial success rate.

Age Factors↗

The use of transesophageal echocardiography to evaluate the effectiveness of patent ductus arteriosus ligation.

The ligation of patent ductus arteriosus (PDA) is a comparatively easy operation, but some complications are possible. The most common complication is incomplete ligation of the PDA; others include inadvertent ligation of the descending aorta or left pulmonary artery, transient rise in systemic blood pressure and increased left ventricular afterload, and acute right heart failure due to pulmonary hypertension. The completeness of the PDA ligation is usually determined only by the operating physician's experience, including the use of an esophageal stethoscope or a finger on the lesion to feel for vibration. These methods sometimes fail to detect an incomplete ligation. With transesophageal echocardiography (TEE), we have monitored the entire course of the PDA ligation directly without interrupting the surgical procedure, and precisely determined the completeness of the ligation. We also expect that TEE will enable us to avoid other complications as well.

Adolescent↗

Double-umbrella device for transvenous closure of patent ductus arteriosus and atrial septal defect: first experience.

A new device for transcatheter closure of heart defects was constructed and used to close a patent ductus arteriosus (PDA) in seven adult patients and an atrial septal defect (ASD) in six adult patients. The device consisted of two self-opening umbrellas and a piece of Ivalon. A Dacron patch was sewn on the "male" umbrella for the ASD closure. The device required a 9 Fr introducing venous sheath for PDA and a 14 Fr sheath for the ASD. The venoarterial (right femoral vein-PDA or ASD-left femoral artery) long wire track was arranged. The "male" umbrella and the Ivalon were inserted transvenously one after another, advanced over the long wire across the PDA or ASD and extruded into the aorta or left atrium, respectively. The "female" umbrella was advanced transvenously over the long wire into the pulmonary artery (for PDA) or into the right atrium (for ASD). The metal conus on the long wire was used to pull the "male" umbrella while a special stiff pusher was used to bring the "female" umbrella to the "male" umbrella along the long wire. By these means the umbrellas interlocked at the defect level and closed it. The long wire was then removed through the left femoral artery. Protrusion of the interlocked device through the PDA occurred in one patient and through the ASD in two patients. In all three patients the device was kept on the wire until surgery and an early postrelease device embolization was avoided. In all other patients the defects were successfully closed. The follow-up of 3-27 months was uneventful in all patients. These results indicate that the described procedure is effective and safe, and warrants further clinical trial.

Adult↗

Transfemoral plug closure of patent ductus arteriosus: experiences at Osaka Prefectural Hospital.

Transfemoral plug closure of PDA (patent ductus arteriosus), which was originally introduced by Porstmann in 1968, was successful in 73 of 74 consecutive patients at Osaka Prefectural Hospital. Some instrumental and technical modifications were made. There has been no mortality, and no dislodgment of the plug occurred after the modified plug with a barbed head was used although a major complication during the procedure was the dislodgment of the plug into the aorta, which occurred early in three cases. There was no recurrence of shunting or any other complications in the long-term follow-up studies. For the patient with a simple isolated PDA over 3 years of age, the catheter technique is considered to be the method of choice to close the ductus.

Adolescent↗

Nonoperative closure of the patent ductus arteriosus: the Frankfurt experience.

Nonoperative closure of patent ductus arteriosus (PDA) by means of Ivalon plugs (according to the technique of Porstmann) was performed in 101 patients. Sixty-five patients were symptomatic, the Q p/Q s ratio exceeded 1.5 in 56 patients, and pulmonary hypertension (mean pulmonary artery pressure greater than 20 mmHg) was present in 50 patients. In 100/101 patients the PDA could be closed successfully. Ninety-nine patients were without any evidence of residual left-to-right shunt. In one patient a hemodynamically insignificant left-to-right shunt was found with color Doppler echocardiography. Complications were pulmonary embolism due to plug dislocation in two patients (12th and 14th patient; 2 and 7 weeks after the procedure, respectively). One of these patients underwent elective surgery with patch closure of the ductus and removal of the embolized plug. In the other patient the ductus was successfully closed with a second larger plug while the first plug was left in a peripheral pulmonary artery. Surgical revision of the femoral artery was required in six and blood transfusion in two patients. Deep venous thrombosis developed in two patients. During follow-up (total follow-up time more than 200 patient years) no late complications were observed. In conclusion, transfemoral catheter closure of PDA by means of Ivalon plugs is an effective method. It is applicable to adolescents and adults with a low complication rate. The ductus can be closed without residual left-to-right shunt. Long-term results are excellent.

Adolescent↗

Transcatheter occlusion of patent ductus arteriosus.

This article reviews the current status of transcatheter technology, which has been applied to close the patent ductus arteriosus (PDA). Pioneering work in this field was performed by Porstmann in the 1960s and Rashkind in the 1970s. Devices which have been implanted in the PDA have basic designs as plugs, umbrellas, or coils. The experience reported with each type of device is detailed. Issues and controversies are examined. It appears that coils should be the preferred method for closing smaller PDAs (3-mm diameter or smaller), and Rashkind or similar devices, if available, should be reserved for larger PDAs (> 3-mm diameter). Surgery is necessary for neonatal and for rare large PDAs. Transcatheter technology is still evolving and may become more effective and cheaper.

Cardiac Catheterization↗

Early experience with the Amplatzer ductal occluder for closure of the persistently patent ductus arteriosus.

Using an Amplatzer duct occluder, 106 patients (weight 21 +/- 18 kg) underwent an attempt at catheter closure of a persistently patent ductus arteriosus (PDA). Their age ranged from 22 days to 48 years. The PDA measured between 1.2 to 8.1 mm at its narrowest diameter. The device was successfully implanted in 105 patients. The immediate closure rate was 70% and gradually increased to 100% at 1-month follow-up. There was no clinical evidence of hemolysis and no incidence of device embolization or bacterial arteritis. Doppler evaluation showed no evidence of aortic arch or pulmonary artery obstruction. The device, which is currently undergoing multicenter clinical trial in the United States, is proving to be a safe and effective device for closure of the persistently PDA.

Adolescent↗

Simultaneous double or triple coil technique for closure of moderate sized (> or = 3.0 mm) patent ductus arteriosus.

One important complication of coil occlusion of patent ductus arteriosus using the conventional Gianturco coil is migration of coils into peripheral vessels. Especially in patients having relatively larger size ductus, the risk for such complication could be increased. In this regard, a detachable coil may have some technical benefits in performing coil occlusion and reducing the incidence of complications such as migration of coil. Based on our clinical experiences, we describe the clinical efficacy of a simultaneous double or triple coil occlusion technique using the Cook detachable coil system to close the ductus arteriosus, especially in patients whose ductus diameter more than 3.0 mm.

Adolescent↗

Comparison between the safety profile and clinical results of the Cook detachable and Gianturco coils for transcatheter closure of patent ductus arteriosus in 272 patients.

OBJECTIVES: We evaluated the occlusion rate and safety of Cook detachable coils versus Gianturco coils in transcatheter closure of patent ductus arteriosus (PDA). BACKGROUND: The Cook detachable coil recently was introduced in an attempt to improve the safety of transcatheter closure of PDA. METHODS: Between January 1994 and September 1998, 272 patients underwent transcatheter PDA closure. Cook detachable coils were used in 137 patients, with a mean age of 43.9 months and weight of 13.8 kg. In 135 patients, Gianturco coils were used, with a mean age of 56.8 months and weight of 17.8 kg. The mean narrowest diameter of the PDA in the Cook detachable coil group was 2.85 mm versus 2.32 mm for the Gianturco coil group. RESULTS: The Cook detachable coil group was younger and weighed less than the Gianturco group (P < 0.05 and 0.02, respectively). Their narrowest PDA diameter was larger (P < 0.01). Embolization rate was significantly lower in the Cook coil group (9[6.5%] of 137 vs 22 (16.3%) of 135; P = < 0.013). The mean follow-up for the Cook coil group was significantly shorter (0.55 years) than for the Gianturco coil group (1.18 years; P < 0.001). On an intention-to-treat basis, complete occlusion by echocardiography was achieved in 99 (72.3%) of 137 patients in the Cook detachable coil group, which was significantly less than the Gianturco coil group (114 [84.4%] of 135; P = 0.008). CONCLUSION: Cook detachable coils for transcatheter closures of the PDA are safer than Gianturco coils. Hence, children with large ductal can be treated earlier in life. Short-term complete occlusion rate was lower in the Cook detachable coil group. This rate can be explained by a shorter follow-up time, larger ductal diameter, and the different materials used for the detachable coils.

Adolescent↗

The Sideris buttoned devices for transcatheter closure of patent ductus arteriosus.

This article reviews the experience in the last decade with Sideris buttoned devices for occlusion of patent ductus arteriosus (PDA). The devices used were the regular buttoned device, the infant buttoned device, the device with the folding plug, and the wireless device. The buttoned devices were implanted transvenously and introduced through 7Fr-8Fr long sheaths for PDAs up to 12 mm; wireless devices required 9Fr-11Fr sheaths for PDAs up to 22 mm. All different shapes of ductus were occluded. The records of 356 patients in the international and Food and Drug Administration (FDA) supervised United States (US) clinical trials were reviewed. Despite excellent long-term full occlusion rates and the absence of significant complications with the regular buttoned device, modifications were necessary to improve the full occlusion rates in 24 hours. The 24-hour rates improved from 60% with the regular device to 85% with the folding plug device. Most residual shunts disappeared on long-term follow-up without significant complications. Wireless devices were developed for very large PDAs and have excellent occlusion rates. The buttoned device with the incorporated folding plug and the wireless devices are currently under clinical trial. The safety record of the new devices needs to be established with larger clinical trials.

Adolescent↗

Patent ductus arteriosus equipment and technique. Amplatzer duct occluder: intermediate-term follow-up and technical considerations.

Between May 1997 and June 2000, 69 patients, ages 0.1 to 34 years, underwent attempted anterograde transcatheter closure of a patent ductus arteriosus (PDA) using the Amplatzer Duct Occluder (ADO). The ADO is a cone-shaped, self-centering, and repositionable occluder made of nitinol wire mesh. A 5Fr to 7Fr sheath was used for the delivery of the device. The mean PDA diameter (at the pulmonary end) was 4.6 +/- 1.9 mm (range 1 mm-8.5 mm). Sixty-seven of the 69 patients had successful device placement. The mean ADO smallest diameter was 6.9 +/- 1.8 mm (range 4 mm-12 mm). Complete angiographic closure occurred in 62 (92.5%) of 67 patients (95% confidence interval, 88.22%-98.77%). In five patients, there was a trivial residual shunt immediately after the procedure. At 24 hours, color Doppler flow imaging revealed complete closure in all 67 (100%) patients. The unsuccessful attempts occurred in two patients with a small, 1-mm diameter native PDA and residual PDA after surgical occlusion. Fluoroscopy time was 7.6 +/- 1.8 minutes (4 min-18 min). No complications were observed. At a median follow-up of 1.5 years (range 0.25 to 3.2 years), all patients had complete closure without complications. We conclude that transcatheter closure using the ADO is a highly effective and safe treatment for most patients with PDA.

Adolescent↗