Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ENDODONTICS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81Linked to original sources

The restoration of endodontically treated, single-rooted teeth with cast or direct posts and cores: a systematic review.

Direct post-and-core restorations with prefabricated posts are becoming increasingly popular. A literature review was conducted to compare the clinical and in vitro performance of cast posts and cores to that of direct cores with prefabricated posts in single-rooted teeth. Research on the restoration of endodontically treated teeth was identified through a search of electronic databases. The search yielded a total of 1773 references. After these references were subjected to strict inclusion criteria, 10 in vitro and 6 in vivo studies remained and critically reviewed. A comparison of fracture loads in the in vitro studies revealed no significant difference between cast and direct posts and cores. Meta-analysis of the data suggested that there is no difference in fracture behavior associated with the 2 treatment modalities. An overall survival analysis was not possible for the in vivo studies. The survival for cast posts and cores in 2 studies ranged from 87.2% to 88.1% and in a third study reached 86.4% for direct cores after 72 months. Randomized clinical trials on this topic were not available but should be conducted to verify published findings.

Dental Prosthesis Design↗

Fracture strength after dynamic loading of endodontically treated teeth restored with different post-and-core systems.

STATEMENT OF PROBLEM: Prefabricated metal and ceramic posts can be used with direct or indirect cores as an alternative to the conventional cast post and core. It is unclear how the fracture strength of zirconia posts with composite or ceramic cores and titanium posts with composite cores compares to the fracture strength of gold posts and cores after dynamic loading. PURPOSE: This study compared the fracture strength of endodontically treated, crowned maxillary incisors with limited ferrule length and different post-and-core systems after fatigue loading. MATERIAL AND METHODS: Sixty-four caries-free, human maxillary central incisors were divided into 4 groups. After root canal treatment, Group 1 was restored with titanium posts and composite cores, Group 2 with zirconia posts and composite cores, and Group 3 with zirconia posts and heat-pressed ceramic cores. Teeth restored with cast-on gold posts and cores served as the controls (Group 4). Teeth were prepared with a circumferential shoulder including a 1 to 2 mm ferrule; all posts were cemented with an adhesive resin cement, restored with complete-coverage crowns, and exposed to 1.2 million load cycles (30 N) in a computer-controlled chewing simulator. Simultaneous thermocycling between 5 degrees C and 55 degrees C was applied for 60 seconds with an intermediate pause of 12 seconds. All specimens that did not fracture during dynamic loading were loaded until fracture in a universal testing machine at a crosshead speed of 1.5 mm/min; loads were applied at an angle of 130 degrees at the incisal edge. Fracture loads (N) and modes (repairable or catastrophic) were recorded. The Kruskal-Wallis test was used to compare fracture loads among the 4 test groups. Analyses were conducted both with and without the specimens that failed during the chewing simulation. A Fisher exact test was performed to detect group differences in fracture modes. A significance level of P<.05 was used for all comparisons. RESULTS: The following survival rates were recorded after the chewing simulation: 93.8% (Group 1), 93.8% (Group 2), 100% (Group 3), and 87.5% (Group 4). The median fracture strengths for Groups 1 to 4 were 450 N, 503 N, 521 N, and 408 N, respectively. No significant differences were detected among the groups. The use of zirconia posts resulted in a nonsignificant lower number of catastrophic root fractures. CONCLUSION: Within the limitations of this study, the results suggest that zirconia posts with ceramic cores can be recommended as an alternative to cast posts and cores. If a chairside procedure is preferred, zirconia or titanium posts with composite cores can be used. Clinical trials are required to verify these in vitro results.

Ceramics↗

Effect of core stiffness on the in vitro fracture of crowned, endodontically treated teeth.

STATEMENT OF PROBLEM: Dentin and core materials that substitute for missing dentin are dissimilar materials. A core material with a lower elastic modulus may deform more under applied stress and therefore result in reduced stress concentration at the core/dentin junction. PURPOSE: This in vitro study examined the effect of core stiffness on the fracture resistance and failure characteristics of a crowned, endodontically treated tooth under simulated occlusal load. MATERIAL AND METHODS: Forty extracted human mandibular premolars were divided equally into 4 groups and prepared for posts and cast crowns as follows: group 1 = cast post and core, cast crown; group 2 = preformed metal post, composite core, and cast crown; group 3 = preformed metal post, amalgam core, and cast crown; and group 4 (control) = preformed metal post, no core, and cast crown. All prepared teeth had 2 mm of sound dentin on which the cemented crown rested. A continuous load (kg) was applied to the buccal cusp at a 30-degree angle to the long axis of each tooth at a crosshead speed of 2 mm/min until failure. Collected data were subjected to 1-way analysis of variance with the Welch modification to compare groups (P<.05). RESULTS: Failure loads for the 4 test groups were as follows: 98.1 +/- 34.6 kg (group 1), 94.4 +/- 41.8 kg (group 2), 105.5 +/- 18.6 kg (group 3), and 101.1 +/- 55.3 kg (group 4). No significant difference in failure load values was found among the 4 groups. The primary mode of failure (80%) in all groups was an oblique radicular fracture, either apical to the post or at the post level. Horizontal fracture of the root and post was found in groups 1, 2, and 3 (20%). Loosening of the crown, post, and core was found only in group 2(20%). CONCLUSION: Within the limitations of this study, core stiffness did not affect the failure resistance of teeth restored with posts and cores and complete-coverage cast metal crowns. The dominant pattern of failure was unrepairable root fracture. Only the composite core exhibited repairable fractures.

Bicuspid↗

In vitro study of the effects of Nd:YAG laser irradiation on the apical sealing of endodontic fillings performed with and without dentin plugs.

OBJECTIVE: The aim of this study was to evaluate the effects of Nd:YAG laser irradiation on the apical sealing of root canal fillings with or without a dentin plug. BACKGROUND DATA: Previous studies have shown that Nd:YAG laser irradiation of root canal wall dentin promotes its melting, recrystallization, and therefore a less permeable surface. MATERIALS AND METHODS: Thirty extracted and endodontically treated teeth were divided into three groups. Eight specimens of each group were evaluated by means of quantitative analysis, measuring the marginal apical dye leakage. The remaining two specimens were evaluated by means of qualitative analysis, using the scanning electron microscopy (SEM). For the quantitative analysis, the samples of group I were obturated. In group II, the apical third of the samples were irradiated by the Nd:YAG laser at four exposures of 100 mJ/pulse, 1 W, 10 Hz, 3 sec, and obturated. In group III, an apical dentin plug was condensed and lased using the same parameters of group II, and the root canals were obturated. The samples evaluated by SEM were prepared as those analyzed quantitatively; however, their root canals were not filled. RESULTS: There were statistically significant differences among the groups regarding dye leakage. Group II showed the minor leakage average, followed, in order, by groups I and III. SEM analysis revealed open dentinal tubules in group I; melting and recrystallizing of the apical root dentin in group II; and melting and recrystallizing of a portion of the dentin plug in group III. CONCLUSION: The Nd:YAG laser irradiation of the root canal apical third without the presence of dentin plug significantly improved the quality of the apical sealing under the experimental conditions tested.

Dental Pulp Cavity↗

Three years of clinical evaluation of endodontically treated teeth by 15 F CO2 laser microprobe: in vivo study.

OBJECTIVE: Evaluation of the efficiency of 15 F CO2 laser microprobe, in cases of periapical lesions. The elimination of the pathological reaction caused by certain species of bacteria by reduction of reinfection and stimulation of osteogenesis. SUMMARY BACKGROUND DATA: Until now, no suitable delivery fiber existed for CO2 laser endodontic radiation in the apical region where it is most difficult to eliminate the pulp tissue using conventional methods. To overcome this problem, Sharplan Lasers designed a microprobe that reaches closer to the apex, distributing the energy density to a smaller area of the root canal, thus favorably increasing the thermal effects. METHODS: The study was conducted on 900 teeth, corresponding to 1512 root canals, divided in two groups. Four hundred sixty-eight were new cases, carefully selected according to strict parameters such as wide periapical translucency over 1 mm, supported by digital x-ray, with a lesion of 3 mm and more. All root canals were mechanically prepared in the conventional method up to size 35, Physiological saline solution served as rinsing solution and the root canals were treated by 15 F CO2 laser microprobe for 60 pulses repeatedly. The temperature at the surrounding tissue of the root did not exceed 38 degrees C. RESULTS: Filling of the canal was possible at the same appointment, without antibiotic treatment. Four hundred thirty-two of the cases, which were referred to us by other dentists after an unsuccessful treatment according to the classic therapy, were treated by the same laser therapy. Follow-up was performed by clinical examination, and a digital x-ray was taken, during and after treatment as well as after 3, 6, 9, and 12 months. CONCLUSIONS: There is a 98% success rate in both study groups, according to objective criteria for successful treatment including reduction of apical translucency after 2-6 months, freedom from clinical complaints, and no need for periapical surgery.

Humans↗

A T.E.M. stereological analysis of blood vessels and nerves in marmoset periodontal ligament following endodontics and magnetic incisor extrusion.

Maxillary incisor fracture is a common dental injury. It is frequently treated by endodontic therapy, orthodontic extrusion, and a retention period. The aim of the study was to mimic this regime and stereologically quantify the vascular and neural reconstitution of the periodontal ligament (PDL). Ten marmosets (Callithrix jacchus) had the right maxillary incisor crown removed, root canal treatment, and magnetic incisor root extrusion of 1.2 mm. After incisor retention for 9 weeks, the animals were perfusion fixed for electron microscopy. The incisor PDL was sectioned at 250 micron intervals from the cervical to apical region and recorded for stereological evaluation. Further evaluations were conducted with a two-way analysis of covariance using program 3V of the BMDP-81 statistical software package. The total luminal PDL vascular volume was statistically unchanged. An increased occurred in the mean number of venous capillaries from 0.07 +/- 0.3 to 0.17 +/- 0.3 per 560 microns 2 of PDL (P < 0.05). Vessel wall and luminal volume of post-capillary-sized venules decreased from 1.64 to 1.03 per cent, and 5.32 to 3.04 per cent (P < 0.05), respectively. Mean luminal and abluminal diameters for post-capillary-sized venules were reduced (P < 0.05). Myelinated and unmyelinated axons showed no significant change in volume (Vv), length (Lv), or surface (Sv) densities. Axon number/unit, PDL area, and mean diameters demonstrated no statistical differences. Since the PDL demonstrated almost complete morphological re-establishment of the microvascular and axon systems, it is considered that this clinical treatment is a justifiable rationale.

Analysis of Variance↗

Comparison of digital dental X-ray systems with self-developing film and manual processing for endodontic file length determination.

Human skulls were sectioned into 15 sextants. Teeth were then removed and 45 canals were instrumented to their apical foramina. Endodontic files were glued in place at random distances from the apical foramina. Image geometry was maintained by a custom mounting jig. Images were captured with self-developing film, manually processed D-speed film, and a digital radiographic system (Dexis). Digital images were read on a conventional color monitor (cathode ray tube) and a laptop screen (active-matrix liquid crystal display). Fifteen dentists measured the distance from the file tip to the apical foramen of the tooth. Results showed that the measurement error was significantly less for the digital images than for the film-based images. It is likely that these statistical differences may not be of great clinical significance because the digital images could be measured in increments < 0.25 mm.

Analysis of Variance↗

Effect of using electronic apex locators on selected endodontic treatment parameters.

The purpose of this study was to determine the effect of using electronic apex locators on the number of radiographs taken and the adequacy in length of the final obturation. Patients in an undergraduate student endodontics clinic participated in the study. The working length (WL) was estimated by the authors for all cases (36 teeth; 58 canals), using both a preoperative standardized radiograph and an electronic measurement. The students were then asked to place WL files to one of the estimates (electronic or radiographic; chosen by random assignment) and take a WL radiograph. Neither the students nor their instructors knew which method was chosen for the estimates. Once treatment was completed, the total number of working radiographs was counted. The number of cases with acceptable (0 to 2 mm short of the apex) or unacceptable obturation was also blindly registered. An electronic estimate of the WL improved length quality of the final obturation, compared with a radiographic estimate. The number of working radiographs taken was less in the electronic apex locator group in anterior and premolar teeth, but not in molars.

Adult↗

A successful nonsurgical treatment of an endodontic failure.

This study presents a relatively uncomplicated endodontic failure that responded to nonsurgical treatment. Speculation as to other interpretations of the failure with related treatment plans is offered to highlight how significant diagnosis can be in determining outcomes.

Child↗

Effects of the Nd:YAP laser on coronal restorative materials: implications for endodontic retreatment.

With new wavelengths that allow light transmission by optical fibers, the laser is now often used in endodontics either during treatment or retreatment. The aims of this study were to (i) specify the effects of laser irradiation on restorative materials in terms of topographic effects and (ii) describe different protocols for the first steps of retreatment. The laser used in this study was an optical fiber Nd:YAP (Lokki dt, Vienne, France) with a wavelength of 1.34 microns. Samples of the following restorative materials were prepared: amalgam, composite, permanent and temporary cements, and prosthodontic alloy. The handpiece of the Nd:YAP laser was fixed perpendicular to the surface of the different preparations. All trials were performed with the fiber tip either in contact with or at a distance of 2 mm from the material. The surface effects in all cases were (i) the creation of craters in the center of the lased areas, (ii) a border of fusion material at the edge of the craters, and (iii) cracks or fractures at a distance from the target areas. For the cements, amalgam and composite, the effects included a projection of material from the center to the edge of the lased area and/or the apparent photovolatization of light particles. For all materials the laser induced deeper absorption in the areas of direct contact than when it was held at a distance. This suggests that the fiber should be in contact with the restorative material for lasing in the straight part of the canal when the objective is either to pass through the material or alongside it between material and tooth. If the practitioner cannot determine the direction of the curve of the canal, lasing should be performed at a distance to weaken the material and thus permit more efficient use of an ultrasonic device. Lasing should in all cases be performed under close X-ray monitoring. Provided that sufficient caution is used, the laser may be helpful in removing restorative materials during retreatment.

Absorption↗

Effect of penicillin on postoperative endodontic pain and swelling in symptomatic necrotic teeth.

The purpose of this prospective, randomized, double-blind, placebo-controlled study was to determine the effect of penicillin on postoperative pain and swelling in symptomatic necrotic teeth. Forty-one emergency patients participated and each had a clinical diagnosis of a symptomatic necrotic tooth with associated periapical radiolucency. After endodontic treatment patients randomly received a 7-day oral dose (twenty-eight 500 mg capsules to be taken every 6 h) of either penicillin or a placebo control in a double-blind manner. Patients also received ibuprofen; acetaminophen with codeine (30 mg); and a 7-day diary to record pain, percussion pain, swelling, and number and type of pain medication taken. The majority of patients with symptomatic necrotic teeth had significant postoperative pain and require analgesic medication to manage this pain. The administration of penicillin postoperatively did not significantly (p > 0.05) reduce pain, percussion pain, swelling, or the number of analgesic medications taken for symptomatic necrotic teeth with periapical radiolucencies.

Acetaminophen↗

Radiographic evaluation of periradicular repair after endodontic treatment of dog's teeth with induced periradicular periodontitis.

Eighty-four root canals of premolars from six dogs were left open for 7 days, and then sealed and followed for 45 days until periradicular periodontitis developed. The root canals were then treated endodontically using 5.25% sodium hypochlorite as the irrigating solution. After instrumentation, all root canals were filled with a calcium hydroxide-based antibacterial dressing (Calen PMCC or Calasept) that was left in place for 30 days. After this period the root canals were filled with gutta-percha cones and a root canal sealer (Sealapex or AH Plus)--group I: Calen PMCC + Sealapex; group II: Calasept + Sealapex; group III: Calen PMCC + AH Plus; and group IV: Calasept + AH Plus. Periapical radiographs of the teeth were made after root canal filling and after 90, 180, 270, and 360 days. Radiographic images were digitalized by scanning, and the Mocha program was used to measure the periapical lesions. Analysis showed that the lesions of groups I to III were statistically similar reduction in size, whereas group IV had a smaller reduction in lesion size (p < 0.05).

Animals↗

In vitro longitudinal assessment of coronal discoloration from endodontic sealers.

A major cause of tooth discoloration may be sealer remnants in the chamber. The objective of this study was to evaluate, longitudinally, coronal discoloration from four sealers. Extracted premolars were sectioned in the coronal third of the root. The chamber contents were removed and instrumentation was via the canal. The following sealers were bulk introduced into the chamber: AH26, Kerr Pulp Canal Sealer, Roths 801 (nonstaining), and Sealapex. The apical access was sealed with white sticky wax. Teeth were maintained in a moist environment at 37 degrees C. Initial (immediate pretreatment) digital images of the teeth were made for base line comparison. Subsequent images were at 1-, 3-, 9-, and 12-month intervals. Then images were mixed and descriptively evaluated blindly by trained evaluators. Discoloration was induced by the four sealers, with slight to moderate visible changes that increased through 12 months. There was slightly more discoloration with AH26 and Kerr Pulp Canal Sealer. In conclusion discoloration induced by the endodontic sealers produced slight to moderate and generally progressive discoloration over 12 months.

Bicuspid↗

Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors.

This study investigated the cyclic fatigue resistance of used nickel-titanium rotary instruments, clinically operated by a traditional high-torque motor and a new low-torque electric motor. Fifty instruments (ProFile, Maillefer, Baillagues, Switzerland) for each of the following sizes were used: .06-25, .06-20, and .04-25. They were divided into three groups: A = 10 new instruments (control), B = 20 used instruments operated by a high-torque motor, and C = 20 used instruments operated by a low-torque motor. Each instrument was used in 10 clinical cases (at least six molars). Cyclic fatigue testing of new and used instruments was performed with a device that allowed the instruments to rotate freely inside a stainless-steel artificial canal at 350 rpm. Data were recorded and statistically analyzed. Mean (and SD) numbers of rotation-to-breakage cycles for .06-25, .06-20, and .04-25 instruments were, respectively: group A 463 (85), 535 (101), and 613 (105); group B 229 (64), 343 (92), and 233 (84); and group C 352 (77), 454 (89), and 466 (86). Results showed that group A instruments exhibited significantly higher values of rotation-to-breakage cycles (two-sample t test, p < 0.01), when compared with groups B and C, respectively. Statistically higher resistance to cyclic fatigue was noted for group C in all sizes compared with group B (two-sample t test, p < 0.01), showing that the use of endodontic motor with lower torque values reduced cyclic fatigue of nickel-titanium rotary instruments.

Dental High-Speed Technique↗

Measurement of endodontic file lengths: calibrated versus uncalibrated digital images.

This in vitro study compared the accuracy of file length measurements made on calibrated and uncalibrated direct digital images. Endodontic files of known lengths and ISO sizes were used in 10 single-rooted, relatively straight teeth within cadaver specimens. The crowns of the teeth were ground flat and an orthodontic wire of known length was secured to the coronal surface. This wire was placed mesiodistally and perpendicular to the root and served as the reference point for the file measurement and as a calibration reference length. A #20 file was hand-measured to a length that reached the apical third of each tooth. It was inserted and a radiographic image was secured. The instrument was remeasured three additional times at different lengths on the same tooth and reinserted before each image acquisition. Thus 40 digital images were acquired using a GE X-ray unit and a Schick Computed Dental Radiography (CDR) #2 sensor. These images were placed in random order, and an independent, blinded investigator determined the file lengths using on-screen calibrated and uncalibrated measurement of the CDR image with a straight-line and multiple-line measuring technique. The experimental measurements were compared with each other and with the known clinical measurements. A two-way analysis of variance indicated that there was a statistically significant difference showing that the calibrated measurements were more accurate than the uncalibrated measurements (p = 0.0001), and there was no significant difference between the straight-line and multiple-line measuring techniques (p = 0.14).

Analysis of Variance↗

Microbiota of periapical lesions refractory to endodontic therapy.

The periapical microbiota of 36 teeth with refractory apical periodontitis was investigated. None of the teeth had responded to conventional endodontic or long-term (> 6 months), calcium-hydroxide treatment. Eight patients had received antibiotics systemically. After anaerobic culture, a total of 148 microbial strains were detected among 67 microbial species. One of the 36 lesions was culture-negative. Approximately half (51.0%) of the bacterial strains were anaerobic. Gram-positive species constituted 79.5% of the flora. Facultative organisms, such as Staphylococcus, Enterococcus, Enterobacter, Pseudomonas, Stenotrophomonas, Sphingomonas, Bacillus, or Candida species were recovered from 27 of the lesions (75%). Sulfur granules were found in 9 lesions (25%). In these granules Actinomyces israelii, A. viscosus, A. naeslundii, and A. meyeri were identified. Other bacterial species, both gram-positive and gram-negative, were detected in the granules as well. Two sulfur granules did not contain Actinomyces. Scanning electron microscopy demonstrated rod- and spirochete-like cells in the granules, and transmission electron microscopy revealed organisms with copious amounts of extracellular material. Outer membrane vesicles were also seen. Some of the granules were calcified. This study demonstrated a wide variety of microorganisms, particularly gram-positive ones, in the periapical lesions of teeth with refractory apical periodontitis.

Actinomyces↗

Hemostatic efficacy and cardiovascular effects of agents used during endodontic surgery.

The hemostatic efficacy, as well as the cardiovascular effects, of two hemostatic agents currently used during endodontic surgery was examined. The hemostatic agents used were epinephrine pellets (Racellet pellets) or 20% ferric sulfate (Viscostat). Patients were assigned to one of two experimental groups. Blood pressure and pulse rate were recorded pre- and postoperatively and at three additional times during the surgery (root-end resection, root-end preparation, and filling). The adequacy of hemostasis was rated by the surgical operator. Results indicated that there is no significant change in cardiovascular effects when using either of these hemostatic agents. Except in one case where ferric sulfate was the agent, both agents produced surgical hemostasis that allowed for a dry field for root-end filling.

Administration, Topical↗

Clinical relevance of standardization of endodontic files dimensions according to the ISO 3630-1 specification.

The aim of this study was to examine the current status of standardization of endodontic instruments. Measurements of instrument dimensions were conducted on stainless steel H- and K-files (sizes 08-40), as well as on rotary-driven nickel titanium (NiTi) files (sizes 15-40), to determine the incidence and degree of deviation from ISO 3630-1, 1992 specification. In addition, the dimensions of sets of H- and K-files (sizes 08-25) were measured to identify discrepancies in dimensions among instruments within the same size per manufacturer. The percentage of difference in width were used to determine the graduation from each size to the next. None of the files tested complied with the ISO nominal size. All files were within the ISO tolerance limits. However, under such tolerance limits, there is a high possibility of either sizes overlapping or of great differences between two sequential sizes. These results may explain the clinical difficulty found in negotiating narrow and curved canals and may establish the need for a more comprehensive approach on the evaluation methods used in root-canal instrument dimension specifications.

Dental Instruments↗