Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CATHODE”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81Linked to original sources

Enrichment of bovine X and Y spermatozoa by free-flow electrophoresis.

Conditions of separation of bovine spermatozoa according to their differences in electrophoretic mobility were studied using free-flow electrophoresis. Distribution of spermatozoa in the electric field depends on composition of buffer system, field intensities and temperature. Conditions are described for reproducible separation of anodically migrating spermatozoa into two distinct peaks both for cold-immobilized (10-13 degrees C) and for motile cells (25 degrees C). Electrophoresis with the buffer used at 25 degrees C and field intensities of 70-100 V/cm provided high percentages of motile spermatozoa (50-90%) in all fractions. However, the sperm distribution across the fractions was the result of superimposed passive electrophoretic motion towards the anode and the active galvanotactic migration towards the cathode. Separation of X- and Y-spermatozoa was verified by quantification of Y-spermatozoa by means of both in situ hybridization, using Y-specific DNA fragments, and the Y-specific fluorescence staining (f-body test). Y-spermatozoa could be enriched in anodic fractions (112 and 144% relative to control). X-spermatozoa were enriched in cathodic fractions (80 and 68% Y-spermatozoa, as compared to control).

Animals↗

Facilitation of visuo-motor learning by transcranial direct current stimulation of the motor and extrastriate visual areas in humans.

Performance of visuo-motor tasks requires the transfer of visual data to motor performance and depends highly on visual perception and cognitive processing, mainly during the learning phase. The primary aim of this study was to determine if the human middle temporal (MT)+/V5, an extrastriate visual area that is known to mediate motion processing, and the primary motor cortex are involved in learning of visuo-motor coordination tasks. To pursue this, we increased or decreased MT+/V5, primary contralateral motor (M1) and primary visual cortex excitability by 10 min of anodal or cathodal transcranial direct current stimulation in healthy human subjects during the learning phase of a visually guided tracking task. The percentage of correct tracking movements increased significantly in the early learning phase during anodal stimulation, but only when the left V5 or M1 was stimulated. Cathodal stimulation had no significant effect. Also, stimulation of the primary visual cortex was not effective for this kind of task. Our data suggest that the areas V5 and M1 are involved in the early phase of learning of visuo-motor coordination.

Adult↗

Kinetic characterization of two classes of dog liver alcohol dehydrogenase isoenzymes.

In order to relate the catalytic properties of alcohol dehydrogenase (ADH), the rate-limiting enzyme for alcohol metabolism, with the pharmacokinetics of ethanol elimination in vivo, the multiple molecular forms of dog liver ADH were purified and their steady state kinetics investigated. Two different classes of ADH forms were identified by starch gel electrophoresis: the class I isoenzymes migrate to the cathode and the class II forms migrate to the anode. Three different patterns of the cathodic class I isoenzymes were identified in different liver specimens. Three molecular forms were observed for patterns A and C, and five for B. The two classes of isoenzymes were separated by affinity chromatography and purified by column chromatography. The three predominant class I isoenzymes, A1, B2, and C1, in type A, B, and C livers, respectively, were isolated by high performance cation-exchange chromatography. The steady state kinetic constants of the A1, B2, and C1 isoenzymes are similar, but differ substantially from those of the class II enzyme. The class II enzyme is much less sensitive to pyrazole inhibition, Ki = 2 mM, than the class I forms, Ki = 0.6 microM. Methanol is not a substrate for the class II enzyme, whereas it is oxidized by the class I isoenzymes. The class I isoenzymes exhibit a lower Km and substrate inhibition Ki for ethanol, 0.4 and 160 mM, respectively, than values for the class II enzyme, 10 and 610 mM, respectively. The properties of class I and II dog liver ADH are similar to those of the respective isoenzymes purified from human and monkey liver.(ABSTRACT TRUNCATED AT 250 WORDS)

Alcohol Oxidoreductases↗

Internal cardiac defibrillation threshold: effects of acute ischemia.

The influence of myocardial ischemia on defibrillation success was studied using two different lead orientations in halothane-anesthetized pigs. Ischemia was induced by ligating the left anterior descending artery in its distal third. Controls had loosely tied ligatures placed around the artery at the same site. Ventricular fibrillation was induced by electrical stimulation 30 minutes after coronary artery ligation. Defibrillation used a single truncated pulse of approximately 6 ms duration passed to either: a transvenous electrode catheter (Medtronic, 6880) with the cathode in the apex of the right ventricle and the anode in the superior vena cava-atrial junction region, or the cathode in the apex of the right ventricle and a mesh plaque on the epicardium of the basal lateral left ventricle as anode. Ten seconds after the onset of ventricular fibrillation, defibrillation was attempted with increasing incremental energies until defibrillation was achieved. Fibrillation episodes were repeated at 15-minute intervals until the minimum first shock was successful in defibrillating the animal (i.e., defibrillation threshold). The number of animals successfully defibrillated with a minimum energy above or below 30 J was not different between normal and ischemic animals for either electrode configuration (i.e., 3 out of 20 vs 1 out of 13 for the catheter and 5 out of 6 vs 6 out of 7 for the epicardial plaque, respectively). Also, the cumulative percent success as a function of defibrillation energy was similar in both the normal and ischemic groups. There was a significant reduction in the minimum energy necessary for defibrillation when passing current between the right ventricular apex and the left ventricular epicardial plaque. The present results indicate that, despite differences in lead orientations, acute ischemia in the anesthetized pig does not appear to influence defibrillation success.

Animals↗

Cardioversion and defibrillation using a catheter electrode: myocardial damage assessed at autopsy.

A technique has been described for countershock in an intensive care setting using a catheter electrode in patients with recurrent ventricular tachyarrhythmias. During defibrillation or cardioversion an electrode in the superior vena cava acts as an anode and an electrode in the right ventricular apex is the cathode. This report describes the resultant changes in the hearts of four men who died with recent, large myocardial infarcts and who had received eight to 55 countershocks of 2.5-50 joules through the catheter. Mural thrombus and/or focal endothelial hemorrhage was found in three hearts at the anode site. Thrombus was seen at the cathode site in two hearts. Myocardial necrosis, secondary to the catheter, was present in only one heart which had a 2 mm rim of granulation tissue around the distal electrode. It is unlikely that this focal area of right ventricular damage would be clinically important. We conclude, therefore, that repeated countershocks delivered through the catheter system produce little myocardial damage.

Aged↗

A prospective evaluation of single and dual current pathways for transvenous cardioversion in rapid ventricular tachycardia.

By using a prospective randomized study design, we compared the clinical efficacy and safety of single unidirectional and bidirectional transvenous cardioversion shocks for termination of rapid ventricular tachycardia (VT) having cycle lengths less than 300 ms. A Medtronic 6880 catheter was placed in the right ventricular apex and an R2 skin patch electrode was placed over the left scapula. Patients were randomized into two groups. Group A patients received unidirectional transvenous shocks using the two catheter electrodes (right ventricular apical cathode and superior vena caval anode) which resulted in a single current pathway. Group B patients received bidirectional transvenous shocks using a common cathode (right ventricular apex) and two separate anodes (superior vena caval and R2 patch) resulting in two current pathways. Identical shocks with total energies of 2.7, 5.0 and 10.0 J and waveform tilt of 27% were delivered to Groups A and B. In selected Group B patients, delivered shock currents through the right ventricular apex/superior vena caval and right ventricular apex/R2 patch electrode pairs were measured. We analyzed the initial episode of VT with a cycle length less than 300 ms in 33 patients with organic heart disease (mean age, 64 +/- 9 years; mean VT cycle length, 248 +/- 37 ms) who underwent programmed electrical stimulation. Transvenous cardioversion shocks terminated 31% of 16 VT episodes in Group A and 41% of 17 VT episodes in Group B (p greater than .2). The mean successful shock energy was 6.1 +/- 3.7 J in Group A and 3.0 +/- 0.9 J in Group B (p less than .05). Forty percent of all successfully cardioverted episodes in Group A and 86% of all successfully cardioverted VT episodes in Group B were terminated at an energy of 2.7 J (p = .09). Analysis of shock waveforms in Group B revealed 47 to 74% of the total current was transmitted through the right ventricular apex/superior vena caval electrodes and 26 to 53% through the right ventricular apex/R2 electrodes. We conclude that single bidirectional transvenous shocks are effective for rapid VT termination in selected patients. Dual current pathways decrease energies needed for successful transvenous cardioversion in this patient population.

Aged↗

Electrophysiological studies on cardiac catheter ablation.

Clinical and animal investigations have pointed out that high energy electrical shocks are associated with the development of cardiac arrhythmias and with variable success in permanent ablation. The effects of electrode configuration and location on the size of the recorded electrogram was investigated to help explain variable catheter ablation results. We analyzed the cellular effects of catheter ablation shocks and found depression of resting potential, action potential amplitude, dV/dt and action potential duration. The most severe effects were noted with high current densities in tissues located between the cathode and anode. Damage was worse nearest the cathode. Similar cellular studies were completed using argon laser photoablation. Again, there was a decrease in resting potential, action potential amplitude and dV/dt. Laser energy led to a more focal region of myocardium void of action potentials and the border zone of injury was smaller. We also investigated the effects of lower energy shocks (1 to 10 joule) on cardiac tissues. Using microelectrodes, we observed that the membrane potential can "hang up" at the depolarized levels for varying periods of time and that conduction is altered during this membrane "hang-up" period. The duration and membrane hang-up level correlated with shock intensity and shock duration. Sequential shocks resulted in additive membrane "hang-up". We believe that membrane hang-up may be associated with brief arrhythmias observed following catheter ablation since conduction, refractoriness and excitability are all altered.

Action Potentials↗

The ventricular excitability-interval relationship in early diastole in humans: the influence of the electrode configuration during bipolar stimulation.

The purpose of this study was to determine the relationship between ventricular excitability and the extrastimulus (S2) coupling interval in early diastole in humans. The influence of the electrode configuration during bipolar stimulation was examined. Ventricular strength-interval curves were constructed using an eight beat drive train at a cycle length of 600 msec, 2-msec decrements in the S2 coupling interval, and 0.2-mA increments in the current intensity of S2 at each coupling interval. A transient dip in the excitation threshold was observed in early diastole during bipolar pacing when the distal electrode was the anode in six of 17 patients (35%). In contrast, this type of dip was not observed when the distal electrode was the cathode. The excitation threshold at the trough of the dip ranged from 1.0 to 2.2 mA. Unipolar strength-interval curves indicated that a dip occurred with anodal but not cathodal pacing. We postulated that the dip might interfere with the accurate determination of the ventricular effective refractory period by resulting in transient loss of ventricular capture during decremental scanning of diastole with S2. A gap in ventricular capture was produced in all six patients who demonstrated a dip in the bipolar strength-interval curve by selecting an S2 current intensity that fell within the dip. In conclusion, the bipolar strength-interval curve may display an early diastolic dip in the excitation threshold, depending on the electrode configuration.(ABSTRACT TRUNCATED AT 250 WORDS)

Cardiac Pacing, Artificial↗

A comparison of QRS complexes resulting from unipolar and bipolar pacing: implications for pace-mapping.

UNLABELLED: To examine differences in QRS configuration produced by bipolar versus unipolar pacing, 12-lead electrocardiograms recorded during bipolar (distal cathode) pacing with 5- and 10-mm interelectrode distances were compared to electrocardiograms recorded during unipolar cathodal pacing from the distal catheter pole. Pacing was performed at a cycle length of 500 msec using each of the two bipolar configurations at current strengths equal to late diastolic threshold, twice threshold and 10 mA. The pacing site was at the right ventricular apex in 15 patients and at various left ventricular locations in 14 patients. The electrocardiograms recorded during bipolar and unipolar pacing were compared by two independent observers for minor QRS configuration changes, major configuration changes and amplitude changes. Minor configuration differences between unipolar and bipolar pacing occurred occasionally when the interelectrode distance during bipolar pacing was 5 mm (mean +/- S.D. 0.5 +/- 1.2 leads per electrocardiogram). However, when the interelectrode distance was 10 mm, minor configuration differences were seen more commonly (1.3 +/- 2.0 leads per electrocardiogram; P less than 0.05 vs 5-mm distance). Major configuration differences were uncommon with either configuration at all current strengths. Pacing at 10 mA produced a larger number of configuration differences than pacing at either threshold or twice threshold (P less than 0.05). Amplitude differences were seen in a mean of 1.9 +/- 2.1 leads per electrocardiogram with the 5-mm interelectrode distance and a mean of 2.9 +/- 2.1 leads using the 10-mm interelectrode distance (P less than 0.05). IN CONCLUSION: (1) bipolar ventricular pacing can result in QRS complexes that are different from those obtained with unipolar pacing at the same catheter location, presumably due to an anodal contribution during bipolar pacing; (2) increasing the interelectrode distance and stimulus intensity increases these differences; and (3) because the proximal electrode's contribution to depolarization can alter the QRS configuration during pacing in a variable way, the use of bipolar pace-mapping to localize sites of origin of ventricular tachycardia may result in less spatial resolution than unipolar pace-mapping.

Cardiac Catheterization↗

Failure of one conductor in a nonthoracotomy implantable defibrillator lead causing inappropriate sensing and potentially ineffective shock delivery.

We describe how a single defect in a new model transvenous lead for an implantable cardioverter defibrillator can result in malfunction of the sensing and defibrillation circuits. The patient had received shocks during atrial fibrillation without premonitory symptoms. At least one shock was delivered and not felt by the patient. In addition, late in the course, a shock was delivered during atrial fibrillation documented to be with a slow ventricular response. In the transvenous lead, a distal spring functions as the anode for rate sensing and the cathode for defibrillation. The wire from this spring bifurcates near the proximal end of the catheter. One wire from the bifurcation leads to the positive (anode) rate-sensing socket of the pulse generator, and the other wire leads to the negative (cathode) high voltage output socket of the defibrillator for defibrillation and cardioversion. After the inappropriate and unperceived shocks were documented, intraoperative and postoperative electrical testing indicated that intermittent discontinuity of the distal spring system within the proximal yoke of the catheter caused faulty sensing and potentially unreliable defibrillation. This dual malfunction was possible because the distal spring of the lead functions in the high-voltage output and the rate-sensing low-voltage input circuits of the implantable defibrillator.

Defibrillators, Implantable↗

TiN: a suitable coating for defibrillator electrodes?

The electrochemical behavior of porous TiN coating for defibrillator electrodes was investigated by in vitro studies. A commercially available Ti patch was compared with a Ti patch coated with a layer of porous TiN. Similarly, the influence of the TiN coating on a Pt/Ir intracardial electrode was tested. Porous TiN coatings were made by reactive sputtering on the plain electrodes. Electrode potential measurements were performed during monophasic anodic and cathodic defibrillator shocks delivering energies between 1 J and 49 J. Porous TiN coating of Pt/Ir coils was found suitable to deliver cathodal pulses, while a plain coil remains recommended for anodic shocks. TiN coating was of benefit for conventional Ti patches. Particularly, in the case of anodic shocks, the TiN layer protected the Ti-mesh from immediate oxidation. However, above 70 anodic shocks of 49 J, the TiN coating underwent oxidation to an oxynitride. An estimated 180 anodic shocks of 10 J could be delivered before TiN oxidation became measurable by increased polarization.

Biocompatible Materials↗

Effects of initial polarity on defibrillation threshold with biphasic pulses.

BACKGROUND: Previous studies have shown that the polarity of epicardial patches significantly affects the defibrillation efficacy of monophasic shocks. However, whether this improvement can be extended to different pulsing methods and lead systems, such as biphasic shocks using endocardial defibrillating electrodes, is unknown. METHODS: Twenty consecutive patients undergoing testing and permanent implant using an Endotak lead system with a biphasic device were included in the study. In each patient the defibrillation threshold was determined delivering biphasic pulses with the distal coil as the cathode and the proximal coil as the anode during the positive phase and with the polarity reversed. The initial electrode polarity tested was chosen randomly. The defibrillation threshold was defined as the lowest pulse amplitude that effectively terminated ventricular fibrillation induced with 60-Hz alternating current. For each biphasic pulse peak voltage, pulse duration, resistance, and stored energy were recorded. RESULTS: Of the 20 patients, 12 (60%) had lower defibrillation threshold when the proximal coil was negative, whereas only 2 patients had a lower defibrillation threshold when the distal coil was negative. In four patients a subcutaneous patch would have been required if only the biphasic pulse with the distal coil as negative had been tested. The mean stored defibrillation threshold energy was lower with the configuration using the proximal coil as cathode (16.3 +/- 8.8 J vs 21.5 +/- 11 J; P < 0.01). CONCLUSION: Change in the initial polarity of biphasic shocks may influence defibrillation efficacy and should, therefore, be assessed in each patient to achieve a more satisfactory safety margin and minimize the use of more invasive lead configurations.

Defibrillators, Implantable↗

Effects of polarity on defibrillation thresholds using a biphasic waveform in a hot can electrode system.

The polarity of a monophasic and biphasic shocks have been reported to influence DFTs in some studies. The purpose of this study was to evaluate the effect of the first phase polarity on the DFT of a biphasic shock utilizing a nonthoracotomy "hot can" electrode configuration which had a 90-microF capacitance. We tested the hypothesis that anodal first phase was more effective than cathodal ones for defibrillation using biphasic shocks in ten anesthetized pigs weighing 38.9 +/- 3.9 kg. The lead system consisted of a right ventricular catheter electrode with a surface area of 2.7 cm2 and a left pectoral "hot can" electrode with 92.9 cm2 surface area. DFT was determined using a repeated "down-up" technique. A shock was tested 10 seconds after initiation of ventricular fibrillation. The mean delivered energy at DFT was 11.2 +/- 1.7 J when using the right ventricular apex electrode as the cathode and 11.3 +/- 1.2 J (P = NS) when using it as the anode. The peak voltage at DFT was also not significantly different (529.0 +/- 41.3 and 531.8 +/- 28.6 V, respectively). We concluded that the first phase polarity of a biphasic shock used with a nonthroracotomy "hot can" electrode configuration did not affect DFT.

Animals↗

Influence of polarity reversal on defibrillation success with biphasic shocks and a transvenous/subcutaneous defibrillator system in a porcine animal model.

Clinical studies show that polarity reversal affects defibrillation success in transvenous monophasic defibrillators. Current devices use biphasic shocks for defibrillation. We investigated in a porcine animal model whether polarity reversal influences defibrillation success with biphasic shocks. In nine anesthetized, ventilated pigs, the defibrillation efficacy of biphasic shocks (14.3 ms and 10.8 ms pulse duration) with "initial polarity" (IP, distal electrode = cathode) and "reversed polarity" (RP, distal electrode = anode) delivered via a transvenous/subcutaneous lead system was compared. Voltage and current of each defibrillating pulse were recorded on an oscilloscope and impedance calculated as voltage divided by current. Cumulative defibrillation success was significantly higher for RP than for IP for both pulse durations (55% vs 44%, P = 0.019) for 14.3 ms (57% vs 45%, P < 0.05) and insignificantly higher for 10.8 ms (52% vs 42%, P = ns). Impedance was significantly lower with RP at the trailing edge of pulse 1 (IP: 44 +/- 8.4 vs RP: 37 +/- 9.3 with 14.3 ms, P < 0.001 and IP: 44 +/- 6.2 vs RP: 41 +/- 7.6 omega with 10.8 ms, P < 0.001) and the leading edge of pulse 2 (IP: 37 +/- 5 vs RP: 35 +/- 4.2 omega with 14.3 ms, P = 0.05 and IP: 37.5 +/- 3.7 vs RP: 36 +/- 5 omega with 10.8 ms, P = 0.02). In conclusion, in this animal model, internal defibrillation using the distal coil as anode results in higher defibrillation efficacy than using the distal coil as cathode. Calculated impedances show different courses throughout the shock pulses suggesting differences in current flow during the shock.

Animals↗

Improved efficacy of anodal biphasic defibrillation shocks following a failed defibrillation attempt.

Although it is generally assumed that defibrillation becomes more difficult when the duration of VF is prolonged, after a failed defibrillation attempt, there is little information on the defibrillation efficacy of multiple shocks delivered at the same energy. The purpose of this study was to systematically examine the efficacy of a second shock delivered at the same or reversed polarity after a failed first shock. Defibrillation was attempted after 10 seconds of VF in 12 pigs (30-56 kg) using biphasic waveforms and a nonthoracotomy lead system. Shock energy was held constant for the first and second shocks at 50%-90% of the DFT. The second shock was delivered 10 seconds after a failed first shock. First and second shock polarity (first phase) was randomized to (+, +), (+, -), (-, -), (-, +). The incidence of successful defibrillation (for all polarities) was 12.3% for first and 49.1% for second shocks (P < 0.0001). Anodal first shocks had a 17.2% incidence of success as opposed to a 7.4% incidence of success with cathodal first shocks (P = 0.001). Anodal second shocks had a 55.5% incidence of success compared to a 42.7% incidence of success with cathodal second shocks (P = 0.008). There was no significant benefit from polarity reversal after a failed first shock (P = 0.29). In conclusion, less energy is required for successful defibrillation by a second shock after a failed first. The optimal configuration for first and second shocks is with the RV as anode. Polarity reversal of a second shock after a failed first does not affect the probability of second shock success.

Animals↗

Can early timed internal atrial defibrillation shocks reduce the atrial defibrillation threshold?

The defibrillation threshold is markedly reduced very early following the initiation of ventricular fibrillation. The purpose of this study was to determine if the same finding holds true for atrial defibrillation. Sustained, reproducible AF was induced with programmed atrial pacing using acetyl-beta-methylcholine chloride (40-640 microL/min) in six adult sheep (heart weight 245-300 g). Seven timing intervals (125 ms, 200 ms, 1 s, 3 s, 10 s, 30 s, and 5 min after AF induction) and two lead configurations: (1) RA as cathode and CS as anode; and (2) RA as cathode and RV apex as anode were tested. Single capacitor biphasic waveforms (3/1 ms) were delivered and atrial defibrillation thresholds (ADFTs) were determined in random order. No significant differences in leading edge voltage and total energy were detected for the RA-CS configuration for the seven timing intervals. For the RA-RV configuration, a significant difference was detected comparing the voltage for 125 ms to the 5-minute timing interval. For all times except 125 ms, the RA-RV threshold was significantly higher than the RA-CS level. In contrast to ventricular defibrillation, the ADFT does not change significantly within the first 5 minutes after the initiation of AF for the RA-CS configuration. However, if the shock is given very early (125 ms after AF induction) with the RA-RV configuration, the ADFT is lowered almost to the RA-CS level.

Animals↗

Low voltage direct current delivered through unipolar transvenous leads: an alternate method for the induction of ventricular fibrillation.

The induction of VF during testing of an ICD may not always be possible using either burst pacing or high energy T wave shocks. The purpose of this study was to evaluate the effectiveness of low energy DC stimulation for inducing VF in a porcine model. The VFT was measured using constant voltage stimuli and a step-up method in ten anesthetized pigs (25-30 kg). Stimuli of different durations (0.5, 1.0, 2.0 s) were delivered (unsynchronized) between a right ventricular apical coil and a subcutaneous test can. Current was measured from the voltage drop across a series resistor (10 omega). With anodal stimulation, VF required 6.4 +/- 0.2 V compared to 13.8 +/- 0.6 V with cathodal stimulation (P < 0.001). The current required to induce VF (measured 10 ms after the stimulus onset) was 58.3 +/- 2.2 mA with anodal stimulation and 119.3 +/- 4.7 mA with cathodal stimulation (P < 0.001). Stimulus duration did not significantly influence the voltage or current required for VF induction. In 6 of the 10 pigs, synchronizing a 0.5-second stimulus to the R wave did not significantly alter the VFT compared to same stimulus synchronized to mid-upslope of the T wave. The results indicate that VF can be consistently induced through transvenous electrodes by passing unsynchronized DC for 0.5-2 seconds. The induction of VF required about 50% less current and voltage with anodal stimulation. It should be possible to induce VF with the DC voltage available from the internal battery source of an ICD.

Animals↗

Examination of a middle cardiac vein defibrillation coil as stand-alone anode, auxiliary anode, and bystander electrode in a transvenous defibrillation circuit.

In porcine studies anodes in the middle cardiac vein compare favorably with those in the RV. It has not been demonstrated whether the RV and middle cardiac vein or the middle cardiac vein alone anodes are superior when shocking to a conventional SVC and active housing cathode nor whether a bystander middle cardiac vein electrode exerts a passive electrode affect. Twelve pigs were anesthetized and had an active housing implanted in the left pectoral region and defibrillation coils placed at the RV apex and in the SVC. A custom-made defibrillation coil (Ela Medical) was advanced into the middle cardiac vein through a 9 Fr transvenous catheter. The DFT for three anodes (RV; RV and middle cardiac vein; middle cardiac vein) to the SVC and active housing was then assessed by a three reversal binary search, the order of testing was randomized. In seven animals DFT was assessed in the same way for the configuration of RV to SVC and active housing twice more, with and without a bystander middle cardiac vein coil electrode in place. The results were middle cardiac vein 7.5 +/- 1.7 J, RV and middle cardiac vein 7.3 +/- 1.7 J reduced DFT significantly compared to RV 13.8 +/- 4.2 J (both P < 0.000). There was no significant difference between the middle cardiac vein and the middle cardiac vein and RV (P = 0.67, 95% CI for difference -0.64-0.96). The DFT of RV to SVC and the active housing was the same with (13.2 +/- 4.0) and without (13.7 +/- 4.2) the middle cardiac vein bystander coil in place (P = 0.177, 95% CI for difference -0.33-1.33 J). Shocking to a SVC and active housing cathode, middle cardiac vein, and RV and middle cardiac vein anodes are equally effective in lowering DFT compared to the RV. The middle cardiac vein coil electrode does not exert a passive electrode affect on the RV to the SVC and active housing defibrillation.

Animals↗