Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “software tools”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80Linked to original sources

US tissue characterization workstation: applications and design.

This article discusses the purpose, design, and uses of an ultrasonographic tissue characterization workstation. The distinguishing characteristic of a tissue characterization workstation is its ability to analyze and classify image textures. Texture is defined as regularly or randomly repeating patterns. Small texture differences in an image are difficult to observe in the presence of noise. Therefore, it is necessary to analyze the image quantitatively. Quantitative measurements include run-length statistics, fractal dimension, and correlation statistics. The workstation is designed so that a radiologist can analyze the patient's images through an easy-to-use graphical user interface. The workstation software is based on standards, so that it can be run on a variety of different hardware platforms. The workstation can be used in a research environment to distinguish between images of malignant and benign breast lesions, which are difficult to diagnose visually. Further work is being done to make the workstation software into a useful clinical tool.

Image Processing, Computer-Assisted↗

EMG biofeedback in the treatment of dysarthria.

An EMG biofeedback technique was developed for the treatment of dysarthria. It aims at increasing the quantity of information about the myofacial system which can be used by the patients to improve the control of their musculature and speech production. This therapy tool consisting of an application software module (copyright INSERM/CNRS 92) is adaptable for a lot of muscles and speech realizations.

Biofeedback, Psychology↗

iMPACT3: Internet-based development and administration of utility elicitation protocols.

iMPACT3 (Internet Multimedia Preference Assessment Instrument Construction Tool, version 3) is a software development environment that helps researchers build Internet-capable multimedia utility elicitation software programs. The program is a free, openly accessible Web site (http.// preferences.ucsd.edu/impact3/asp). To develop a utility elicitation software program using iMPACT3, a researcher selects modular protocol components from a library and custom tailors the components to the details of his or her research protocol. iMPACT3 builds a Web site implementing the protocol and downloads it to the researcher's computer. In a study of 75 HIV-infected patients, an iMPACT3-generated protocol showed substantial evidence of construct validity and good internal consistency (logic error rates of 4% to 10% and procedural invariance error rates of 10% to 28%, depending on the elicitation method) but only fair 3- to 6-week test-retest reliability (intraclass correlation coefficient= 0.42 to 0.55). Further work may be needed on specific utility assessment procedures, but this study's results confirm iMPACT3's feasibility in facilitating the collection of health state utility data.

Adult↗

Retinal thickness in healthy and diabetic subjects measured using optical coherence tomography mapping software.

PURPOSE: To define the normal retinal thickness in healthy subjects using optical coherence tomography (OCT) mapping software and to assess the ability of OCT to detect early macular thickening in diabetic patients. METHODS: Six radial scans centered on the fixation point were done on 60 healthy eyes and 70 eyes of 35 diabetic patients without macular edema on biomicroscopy. Retinal thickness was measured automatically with OCT mapping software. Mean retinal thickness was compared in subgroups of healthy patients based on age, sex, and eye, and in the eyes of diabetic patients and healthy subjects. Thickening was diagnosed if mean retinal thickness of an area was greater than the mean thickness + 2SD in the corresponding area in healthy subjects; or if the difference between right and left eye exceeded the mean difference + 2 SD in a given area in healthy subjects. RESULTS: In healthy subjects, mean retinal thickness in the central macular area 1000 microm in diameter was 170+/-18 microm. There was no significant difference according to age, or left or right eye, but central macular thickness was significantly greater in men than women (p=0.0139). No difference was observed between the eyes of healthy subjects and diabetic patients without macular edema on biomicroscopy, but OCT detected early macular thickening in 12 diabetic eyes. CONCLUSIONS: In this study average retinal thickness and mean local variations in a normal population were defined using a commercially available mapping software. OCT seems a sensitive tool for detecting early retinal thickening.

Adult↗

A synthetic bioactive resorbable graft for predictable implant reconstruction: part one.

Animal studies were conducted to evaluate the cell response and chemical potentiality of a synthetic bioactive resorbable graft (SBRG) made of nonceramic cluster particulate of low-temperature HA material. The study evaluated bone-bridging of the SBRG particulates in 1-mm wide implant channels of 5 x 8 mm long roughened titanium interface in 6 dogs and compared results to the same implant channels left empty as controls at 6- and 12-week intervals. Resorption rate capacity and cell response were evaluated with an assessment of the chemical characterization of the synthetic nonceramic material next to the titanium implant interfaces. Results of the animal studies were compared with human histologic biopsies of the SBRG for bone quality, density, and bone growth into defect sites concurrent with resorption time of the graft. One human biopsy consisted of a graft mixture of the SBRG and dense bovine-derived HA, compared under the electron microscope, including histology by H and E staining. Part 1 of this paper presents evidence of the predictability and efficacy of the SBRG osteoconductive, particulate chemical potentiality to aid in the regeneration of lost bone anatomy next to titanium implant interfaces. Recent technological innovations in computer hardware and software have given clinicians the tools to determine 3-dimensional quality and density of bone, including anatomical discrepancies, which can aid in the diagnosis and treatment planning for grafting procedures. When teeth are extracted, the surrounding bone and soft tissue are challenged as a result of the natural resorptive process. The diminished structural foundation for prosthetic reconstruction, with or without implants, can be compromised. A synthetic bioactive resorbable graft material having osteoconductive biochemical and biomechanical qualities similar to the host bone provides the means to improve compromised bone topography for ridge preservation, ridge augmentation, or to enhance the bony site for implant placement and subsequent prosthetic rehabilitation. Part two of this paper will demonstrate clinical applications of the SBRG material for purposes of implant placement and prosthetic reconstruction.

Absorbable Implants↗

Predictable synthetic bone grafting procedures for implant reconstruction: part two.

When teeth are missing, the surrounding bone and soft tissue is challenged as a result of the natural resorptive process or from traumatic destruction subsequent to extraction. The diminished structural foundation for prosthetic reconstruction with or without implants can therefore be compromised. Recent technological innovations in computer hardware and software have given clinicians the tools to determine 3-dimensional anatomy, quality, and density of bone, which can aid in the diagnosis and treatment planning for reparative or augmentative grafting procedures. Advanced synthetic bioactive resorbable bone graft (SBRG) materials and innovative surgical techniques have made it possible to predictably alter the defective site to create favorable osseous conditions for implant placement. The synthetically derived, resorbable, cluster-like, hydrophilic, particulate, bone-grafting material, having similar mechanical and chemical properties as the host bone, can provide the means to modify existing bone topography by aggressively overpacking the material for ridge preservation, ridge augmentation, or to enhance the bony site and subsequent prosthetic rehabilitation. Since bone does not bridge in empty spaces, the aggressive overfill, commonly referred to as force mineralization, controls excessive bleeding and eliminates voids. Part 1 of this 2-part series presented evidence of safety and effectiveness of the SBRG materials, crystal morphology, chemical properties, and characterization through animal and clinical studies. The osteoconductive cluster particulate assists in the bridging of lost bone anatomy by chemotactic response and resorption concurrent with regeneration of new bone formations. Part 2 demonstrates specific clinical handling characteristics and use of this material to facilitate implant placement and/or prosthetic reconstruction through clinical case applications. Additionally, in a unique clinical presentation, a composite graft mixture consisting of the SBRG and dense, ceramic, bovine-derived HA (sintered at 1,150 degrees C) was compared using electron microscopy.

Absorbable Implants↗

Dose-escalated 3D conformal radiotherapy in prostate cancer.

3D conformal radiotherapy involves the delivery of radiation to a defined 3D tumor volume while minimizing doses to adjacent critical tissues. The use of sophisticated imaging tools and advanced treatment planning software have allowed for better target definition enabling the oncologist to conform or shape radiation volume more closely around the target while minimizing dose to the rectum and bladder. 3D conformal radiotherapy has resulted in dramatic reductions in acute and late toxicity of radiation treatment in prostate cancer. It has also allowed for safe escalation of radiation dose with improved tumor control compared with conventional dose radiotherapy. Long-term tumor control rates with 3D conformal radiotherapy are comparable with results using radical prostatectomy.

Clinical Trials as Topic↗

GOAT: An R Tool for Analysing Gene Ontologytrade mark Term Enrichment.

UNLABELLED: Understanding the composition of gene lists that result from high-throughput experiments requires elaborate processing of gene annotation lists. In this article we present GOAT (Gene Ontology Analysis Tool), a tool based on the statistical software 'R' for analysing Gene Ontologytrade mark (GO) term enrichment in gene lists. Given a gene list, GOAT calculates the enrichment and statistical significance of every GO term and generates graphical presentations of significantly enriched terms. GOAT works for any organism with a genome-scale GO annotation and allows easy updates of ontologies and annotations. AVAILABILITY: GOAT is freely available from http://dictygenome.org/software/GOAT/ CONTACT: Gad Shaulsky (gadi@bcm.tmc.edu).

Journal Article↗

Using the open-source statistical language R to analyze the dichotomous Rasch model.

R, an open-source statistical language and data analysis tool, is gaining popularity among psychologists currently teaching statistics. R is especially suitable for teaching advanced topics, such as fitting the dichotomous Rasch model--a topic that involves transforming complicated mathematical formulas into statistical computations. This article describes R's use as a teaching tool and a data analysis software program in the analysis of the Rasch model in item response theory. It also explains thetheory behind, as well as an educator's goals for, fitting the Rasch model with joint maximum likelihood estimation. This article also summarizes the R syntax for parameter estimation and the calculation of fit statistics. The results produced by R is compared with the results obtained from MINISTEP and the output of a conditional logit model. The use of R is encouraged because it is free, supported by a network of peer researchers, and covers both basic and advanced topics in statistics frequently used by psychologists.

Algorithms↗

Identification of novel highly expressed genes in pancreatic ductal adenocarcinomas through a bioinformatics analysis of expressed sequence tags.

In most microarray experiments, a significant fraction of the differentially expressed mRNAs identified correspond to expressed sequence tags (ESTs) and are generally discarded from further analyses. We used careful bioinformatics analyses to characterize those ESTs that were found to be highly overexpressed in a series of pancreatic adenocarcinomas. cDNA was prepared from 60 non-neoplastic samples (normal pancreas [n = 20], normal colon [n = 10], or normal duodenal mucosal [n = 30]) and from 64 pancreatic cancers (resected cancers [n = 50] or cancer cell lines [n = 14]) and hybridized to the complete Affymetrix Human Genome U133 GeneChip(R) set (arrays U133A and B) for simultaneous analysis of 45,000 fragments corresponding to 33,000 known genes and 6,000 ESTs. The GeneExpress(R) software system Fold Change Analysis Tool was used and 60 ESTs were identified that were expressed at levels at least 3-fold greater in the pancreatic cancers as compared to normal tissues. Searches against the human genomic sequence and comparative genomic analysis of human and mouse genomes was carried out using basic local alignment search tools (BLAST), BLASTN, and BLASTX, for identifying protein coding genes corresponding to the ESTs. Subsequently, in order to pick the most relevant candidate genes for a more detailed analysis, we looked for domains/motifs in the open reading frames using SMART and Pfam programs. We were able to definitively map 43 of the 60 ESTs to known or novel genes, and 15 of the ESTs could be localized in close proximity to a gene in the human genome although we were unable to establish that the EST was indeed derived from those genes. The differential expression of a subset of genes was confirmed at the protein level by immunohistochemical labeling of tissue microarrays (inhibin beta A [INHBA] and CD29) and/or at the transcript level by RT-PCR (INHBA, AKAP12, ELK3, FOXQ1, EIF5A2, and EFNA5). We conclude that bioinformatics tools can be used to characterize differentially overexpressed ESTs, and that some of these ESTs may represent diagnostically and therapeutically useful targets that might be missed using data solely from currently annotated databases.

Adenocarcinoma↗

EDI streamlines reporting requirements for Medicare managed care.

Using automated eligibility verification tools for Medicare patients can help providers submit clean claims to managed care plans as well as file secondary claims efficiently to fiscal intermediaries. Automated eligibility verification systems combine EDI tools and data-processing software so providers can access databases to secure all the correct information before billing. In addition, an insurance eligibility system can automatically post benefit information to patient account files.

Centers for Medicare and Medicaid Services, U.S.↗

Electronic data management for the Hemochron Jr. Signature coagulation analyzer.

Point-of-care testing (POC, POCT) laboratory devices are being introduced into operating suites and critical care units in ever increasing numbers. The small, portable devices have gained in popularity because of their ease of use and the rapid availability of test results. POCT is an integral part of extracorporeal technology (ECT). A challenge associated with the growth of POC technology is related to management of the data generated by these devices. In the field of ECT, storing, retrieving, analyzing, viewing and charting quality control (QC) and patient test data generated with POC coagulation instruments is essential. We evaluated a premarket version of data management software developed for the Hemochron Jr. Signature coagulation analyzer, a PC-based software capable of fulfilling our objective. A database comprised of greater than 50 plasma and electronic QC results and greater than 140 patient sample results for ACT, PT, and aPTT tests was transferred from a Hemochron Jr. Signature device to two different PCs, each equipped with Hemochron ReportMaker software supplied by the manufacturer. Data files were transferred directly from the coagulation test unit to the PCs via an RS-232 cable. A variety of charts, reports, and file listings were created from the datasets using the software menus. Transfer of the complete database required less than 5 min. The relative speed and simplicity of the data interface promotes frequent charting of QC data, permitting real-time monitoring and early identification of data trends or values requiring intervention. If a subset of QC data is found to be incomplete, altered, or unacceptable, all patient samples tested during that period can be promptly identified. The software also includes data query tools useful for sorting and selecting specific subsets of patient and QC data. Electronic data management can facilitate compliance with quality control requirements and assist clinicians and laboratory personnel in the collection, storage, and review of quality control and patient test data. In addition, the patient and QC data are readily accessible when necessary for use in risk management assessment, accreditation, or litigation proceedings.

Blood Coagulation Tests↗

[OSCAR (one-stop clinic for assessment of fetal risk): our experience with first trimester screening for chromosomal abnormalities].

OBJECTIVES: In recent years has been intensified an effort to develop early more exact non-invasive methods for prenatal diagnosis. We report our experience to screen trisomy 21 and other chromosomal abnormalities in the first trimester in so-called OSCAR (One-Stop Clinic for Assessment of Fetal Risk). DESIGN AND SETTING: It is a retrospective study held at the Department of Medical Genetic and Fetal Medicine, Teaching Hospital, Olomouc. METHODS: A group of 2110 pregnant women has been screened by maternal age as a background risk, fetal nuchal translucency, nasal bone as ultrasound markers as well as maternal serum level of free beta-subunit human chorionic gonadotropin (beta-hCG) and pregnancy-associated plasma protein-A (PAPP-A) as a biochemical markers between 11 - 13+6 weeks of pregnancy from January 2004 to December 2005. The Fetal Medicine Foundation Guidelines and software were the methods and tools used for screening. Karyotyping by chorionic villous sampling or amniocentesis was offered to women with risks > or = 1 in 300. RESULTS: We reported 100% sensitivity for this method for a 4, 6% false positive. There was detected 21 chromosomal abnormalities in which 10 were trisomy 21. This is the first result to be published for this screening method in the Czech Republic. CONCLUSION: In our experience first trimester screening for trisomy 21 and other aneuploidies has a high sensitivity with a low false positive rate and can be delivered in an efficient manner in a one-stop multidisciplinary clinic.

Adolescent↗

Quality assurance.

Modern health care is changing--we have more chronic disease, increasing demands for documentation from government and legal bodies, and greater emphasis on disease screening and prevention. Quality assurance is important in developing health care services to meet these changing needs because it provides standards by which we can measure the activities involved in the delivery of health care, and quality assurance programmes are more likely to ensure that the predefined standards of health care are being met. This paper provides: (i) an acceptable definition of quality assurance (QA); (ii) an explanation of why we need it; (iii) evidence that the medical decision-making process is failing under the modern technological advances; and (iv) guidelines for meeting future health care standards by using the modern technological tools of computers and computer software to support the beleaguered clinical decision-making process.

Australia↗

Physiologic imaging of the lung with volumetric high-resolution CT.

The combination of high-resolution computed tomography (HRCT), rapid volumetric scanning, and advanced image display and analysis applications software is a powerful potential tool for the evaluation of physiologic and pharmacologic events in the lung. Currently employed in the experimental setting, this tool can provide verifiable and quantifiable information about regional responses in the lung, which were previously impossible to demonstrate. This is particularly true when physiologic or pharmacologic effects result in an anatomic change that can be directly imaged and measured within the limits of CT resolution. However, information about events occurring beyond resolution limits is potentially available indirectly from lung density and pulmonary blood flow measurements using CT techniques. The results of animal airway reactivity experiments making use of i.v. methacholine and CT imaging tools are presented as an example of "physiologic imaging."

Animals↗

Development of computer-generated phantoms for FMRI software evaluation.

Functional magnetic resonance imaging (FMRI) is a major tool for the evaluation of brain function and architecture. It is widely used by physicians, neuroscientists, psychologists and others. In order to process the data collected using FMRI, it is necessary to use post-acquisition processing software that employs motion correction and statistical modeling capabilities. These types of programs permit the user to extract the information about areas of brain activations that have occurred during a study. How well a particular motion-correction technique works and what effect it has on statistical processing are difficult to evaluate, since the level of activation present is not known a priori. This paper provides a description of the construction of a software phantom for use with FMRI post-acquisition processing tools with the properties that it is based on real subject data, has known locations and levels of activation, has known amounts of rigid body motion and noise added, and can be used to evaluate a processing system as if it were a real data set. Versions of the software phantom are available for downloading at the website: .

Humans↗

VIR: a computational tool for analysis of immunoglobulin sequences.

In this paper a microcomputer software named VIR (Variable domains of the Immune Receptors) is reported. This package can be used in sequence studies of immunoglobulin variable domains. The main features of the VIR software in the sequences management are: (1) ease of information recovery/extraction from amino acid sequences; and (2) its capability to obtain multiple sequence alignments with predefined characteristics (i.e. specie and/or specificity). As an analytical tool, the VIR package employs such multiple sequence alignments to compute: (1) tables showing amino acid frequencies; (2) three variability indexes; (3) identity matrices; (4) random samples; and (5) sequences with possible canonical structures. Thus the software reported here is proposed as a useful tool to carry out detailed studies of immunoglobulin variable domains.

Amino Acid Sequence↗

Wireless networking for the dental office: current wireless standards and security protocols.

Digital radiography has gained immense popularity in dentistry today in spite of the early difficulty for the profession to embrace the technology. The transition from film to digital has been happening at a faster pace in the fields of Orthodontics, Oral Surgery, Endodontics, Periodontics, and other specialties where the radiographic images (periapical, bitewing, panoramic, cephalometric, and skull radiographs) are being acquired digitally, stored within a server locally, and eventually accessed for diagnostic purposes, along with the rest of the patient data via the patient management software (PMS). A review of the literature shows the diagnostic performance of digital radiography is at least comparable to or even better than that of conventional radiography. Similarly, other digital diagnostic tools like caries detectors, cephalometric analysis software, and digital scanners were used for many years for the diagnosis and treatment planning purposes. The introduction of wireless charged-coupled device (CCD) sensors in early 2004 (Schick Technologies, Long Island City, NY) has moved digital radiography a step further into the wireless era. As with any emerging technology, there are concerns that should be looked into before adapting to the wireless environment. Foremost is the network security involved in the installation and usage of these wireless networks. This article deals with the existing standards and choices in wireless technologies that are available for implementation within a contemporary dental office. The network security protocols that protect the patient data and boost the efficiency of modern day dental clinics are enumerated.

Computer Security↗