The study of elements in organisms by neutron activation analysis. III. The distribution of trace elements in various organs of normal rat and in cell fractions of rat liver.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Iron-deficiency anemia (IDA) is the most common nutritional deficiency in childhood throughout the world. Although it has been shown that IRA is associated with elevated plasma copper and depleted zinc levels in children, there are conflicting results on the effect of iron supplementation on the absorption of these elements. The aim of this study was to investigate the effects of ferrous and ferric iron supplementation on the trace element status in children (n=25, aged 8-168 mo) with IDA. Fourteen of them were treated with ferric hydroxide-polymaltose complex (Ferrum, Vifor, Switzerland) (6 mg/d in the first 3 mo for initial therapy and 3 mg/kg for 3 mo as maintenance); the others were treated with a ferrous sulfate complex (FerroSanol, Schwarz, Germany) (6 mg/d in the first 3 mo for initial therapy and 3 mg/kg for 3 mo as maintenance). Plasma copper, zinc, and ceruloplasmin levels as well as hematological parameters were determined at baseline and the first, third, and sixth month of the treatment period. The hemoglobin and iron levels of patients in both groups were higher in the first and sixth months compared to baseline. Although the ceruloplasmin levels were depleted (48.9 mg/dL vs 41.4 mg/dL, p=0.035) during ferrous iron treatment, the copper and zinc levels remained unchanged. On the other hand, ferric iron supplementation led to an increase in zinc levels in the sixth month of treatment (0.77 mg/L vs 1.0 mg/L, p=0.021). The plasma copper levels were lower in the ferrous iron-treated group at the end of the first month of treatment than in the ferric irontreated group (1.06 mg/L vs 1.29 mg/L, p=0.008). In conclusion, our data showed that copper and ceruloplasmin metabolisms were affected by ferrous iron supplementation, whereas ferric iron kept them to normal levels of zinc, possibly by affecting their absorption. We conclude that the copper and zinc status of patients with IDA should be taken into consideration before and after iron therapy.
The application of a fast program combined with the advantages of the iridium permanent modifier is proposed for trace element analysis of plant samples by electrothermal atomic absorption spectrometry (ETAAS). For two volatile elements (Cd, Pb) and two mid-refractory elements (Cr, Ni) it was demonstrated that coating of the platform or of the tube atomization area with Ir is an efficient means of improving the accuracy and precision of results. A detailed study of interference from individual main matrix components and from composite plant matrices has confirmed the usefulness of the whole approach. The validity of the method has been confirmed by analysis of eight reference plant materials.
The rate of hydrolysis of the synthetic trypsin substrate N alpha-benzoyl-L-arginine-p-nitroanilide was determined from turnover rate curves, when the trace elements zinc, iron, cobalt, and nickel were added in the concentration range from 0.9 . 10(-7) to 0.9 . 10(-3) mol Men+/l. The enzyme substrate ratio was 1:50. An influence on the activity of trypsin, depending on the element used and on its concentration could be determined. Cobalt and iron accelerated the enzyme's capacity of hydrolysis at all concentrations used, whereas addition of higher but not toxic amounts of zinc or nickel resulted in an inhibition.
Instrumental neutron activation analysis has been used to determine the concentrations of 16 elements in selected brain regions and separated gray- and white-matter specimens from histologically verified Alzheimer's disease (AD) and age-matched control patients. Significantly different (p less than 0.05) mean concentrations of Br, Cl, Cs, Hg, N, Na, P, and Rb were observed in AD bulk brain samples compared to controls, while no significant differences were observed for Ag, Co, Cr, Fe, K, Sb, Sc, and Se. The differences that are most persistent and largest in magnitude for the pooled bulk samples, males and females, left and right hemispheres, and separated gray and white matter are the elevation of Br and Hg and the depletion of Rb in AD compared to controls. Significant interelement correlations for the latter elements in both AD and control brains are also documented. Based on these studies, the possibility of an etiological role for trace elements in AD clearly deserves further investigation.
The demonstrated teratogenicity of maternal zinc deficiency in rats has led to burgeoning interest in zinc and other trace elements as important factors in embryonic development. Levels of zinc, copper, manganese, magnesium, folic acid, vitamin B12 and vitamin A were evaluated at the beginning of pregnancy in the plasma of pregnant women who later delivered a malformed newborn. Fetal chromosomal anomalies and recognizable nonchromosomal syndromes were excluded. The results were compared to control women who delivered normal babies. One hundred seventy mothers had malformed children. The more frequent congenital malformations were congenital heart diseases (72 cases including 24 VSD), musculoskeletal malformations (21 cases), urogenital malformations (23 cases), spina bifida (6 cases), hydrocephaly (6 cases), and labial cleft (14 cases). Maternal plasma concentrations of zinc, copper, magnesium, manganese, folate, vitamin B12, and vitamin A of malformed children did not differ from controls. Thus vitamin profiles do not form a suitable means for identifying women at risk for having a child with congenital malformations.
Instrumental neutron activation analysis has been used to determine quantitatively the content of certain trace elements forming the healthy tooth in a sample of 31 teeth extracted for orthodontic or periodontal reasons.
Flow injection-inductively coupled plasma mass spectrometry has been evaluated for determining the distribution profile of trace elements along a single strand of hair. Hair was cut into several mm long sections from follicle to the distal end. Each section was solubilized in a capped 1.5-mL polypropylene tube with small volume of nitric acid (typically 50 microL) at room temperature. After dilution an aliquot (50 microL) was introduced into the mass spectrometer by flow injection. The limit of determination was typically 5-50 pg with 5-10% precision (CV), depending on the element examined; this corresponds to sub-microgram/g concentrations of these elements in hair segments. Recent exposure and intake history of individuals to thallium or mercury could be reconstructed by this system.
This paper reports the contents of amino acids in donkey-hide gelatin made in different pharmaceutical factories before and after processing. An analytical comparison of trace elements in the gelatin is also presented.
Emission spectrum analysis was used for measuring the levels of such trace elements as copper, manganese, zinc, nickel and silver in blood serum and tissues of the diseased organs in female patients with certain precancerous and precursor lesions of genital tract. It was found that such changes as an increase in serum copper, a decrease in zinc concentration in blood cells and a rise in the levels of zinc and silver in the affected tissues were more pronounced in cases of precancerous lesions than in those of precursor pathology.
Experiments were conducted with dwarf goats to investigate effects of 160 days of oral application of high doses of bentonite on the trace element status (Fe, Cu, Zn, Mn). High levels of iron compounds in bentonite batches caused intensified incorporation of these elements into liver and kidney of dwarf goat. Copper and zinc incorporations were reduced but manganese incorporation was increased by oral application of bentonite.
The x-ray standing waves generated by dynamical Bragg diffraction were used to directly measure lattice locations of trace elements within and at the surface of a mineral single crystal. These high-precision measurements were made on natural Iceland spar calcite cleaved along the (1014) plane and reacted with a dilute aqueous lead solution. Within the bulk crystal, naturally occurring trace manganese was found within (1014) planes, consistent with its substitution for calcium. At the crystal surface, sorbed lead was found to be highly ordered and mostly within (1014) planes. This demonstrates a powerful application of synchrotron radiation in the earth and environmental sciences.
1. Environmental problems in areas of intensive animal production necessitate new constraints in food formulation concerning nitrogen and phosphorus and also concerning trace minerals, especially zinc and copper, which are found in excess in poultry manure in relation to nitrogen and might cause phytotoxicity in soil. 2. Whole body concentrations of zinc, iron, manganese and copper were measured in chickens in order to estimate the percentage of deposition and excretion. Body concentrations were determined on 390 chicks of both sexes at different ages in 2 commercial crosses. 3. Age affected the trace element body concentration. Higher concentrations were observed at earlier ages (4 to 11 d). Sex and cross had little influence on body Zn, Fe, Cu and Mn concentration and interactions were observed between these factors. 4. Body retention percentage (% of intake) was very low when birds were fed on commercial diets and decreased with age. For the period 0 to 40 d, the percentages of retention were 6%, 10%, 0.2% and 6% for Zn, Fe, Mn and Cu, respectively, and therefore 90% to 99% was excreted. 5. These findings make it possible to calculate trace mineral excretion for various feeding systems and confirm the excess of zinc and copper in poultry manure in relation to nitrogen. A nutritional approach such as reduction in dietary trace mineral supplementation may alleviate the risks of phytotoxicity in the soil resulting from Zn and Cu excesses.
A sensitive assay using inductively coupled plasma atomic emission spectroscopy (ICP-AES) has been applied to the measurement of trace elements in diaspirin cross-linked hemoglobin (DCLHb) solutions. Calcium, magnesium, zinc and iron were the only elements detected at greater than background levels. Ag, Al, As, B, Ba, Bi, Cd, Co, Cr, Cu, Mn, Mo, Pb, Sb, Se, Si, Sr, Ti, and V were present at concentrations either equal to the acid blanks or were not detected. Detection of non-heme iron (not incorporated into the hemoglobin porphyrin ring) in a 10 g/dL hemoglobin solution required the development of a special protocol. In this protocol a chelator, DTPA, was added to hemoglobin solutions to complex with both free and non-specifically bound non-heme iron. The resulting iron:DTPA complexes were separated from the hemoglobin molecules by ultrafiltration and the ultra-filtrate analyzed by ICP-AES. A modification of this assay in which the DTPA was omitted was used to measure the free non-heme iron in solution. Typical concentrations of chelatable (free and non-specifically bound) and solution (free) non-heme iron in DCLHb production lots at the completion of manufacture were 0.5-1.0 ppm and 0.1-0.3 ppm, respectively.
Analytical techniques used to examine the chemical speciation of multiple trace elements are important for the investigation of biological systems. Size exclusion chromatography (SEC) coupled to ICP-MS was used to investigate the speciation of Se, As, Cu, Cd and Zn in tissue extracts from a largemouth bass (Micropterus salmoides) collected from a coal fly ash basin and results were compared to a largemouth bass collected at a reference site. Using a Biosil SEC column, with an effective separation range of 100-7 KDa, Cu, Zn and Cd were shown to be bound to metallothionein (MT) in the liver, gill and, to a lesser extent, gonad tissue extract. In liver, muscle and gill of the ash basin bass, Se was predominantly present as low molecular weight species. Only in the gonad extract was the major fraction of Se associated with high molecular weight species. For the liver and gill extracts, further SEC-ICP-MS on a column with an effective separation range of 7000-500 Da was performed, but Se species still eluted near the total volume of the column suggesting a low molecular weight organic or inorganic species. Ion chromatography (IC)-ICP-MS using an AS7 column and HNO(3) gradient elution indicated that the Se and As species in the liver and gill extracts had similar retention times but these retention times did not correspond to retention times for As(III), As(V), dimethylarsenate, arsenobetaine, Se(IV), Se(VI), seleno-methionine, or seleno-cystine.
Analysis of the trace element composition of biologic samples obtained from workers engaged in the manufacture of Cu, Zn, and Pb articles helps understand the processes of the formation and development of dental diseases. Accumulation of mobile elements in dental deposits, teeth, saliva, and gingival biopsy specimens evidence oral cavity involvement.
The purpose of this study was analysis of forensic medical aspects of macro- and trace element composition of hairs of the head in the residents of Mexico, Ecuador, Bolivia, Brazil, Columbia and changes in this characteristic during adaptation to conditions of Central Russia. One of our tasks was to define expert criteria for differentiation between the hairs belonging to residents of these countries and Russia. A total of 136 hairs were examined by spectral approximated quantitative analysis using DFS-13 spectrographer. The detected regularity consisted in the following: adaptation of residents of Latin America to conditions of Central Russia was associated with disappearance of some elements and appearance of other ones characteristic of residents of Central Russia (Byelorussians, Russians, Ukrainians).
Effective utilisation of neutron activation analysis (NAA) for the elemental analysis of biomedical samples with or without a radiochemical separation, especially when optimal Ge(Li) well type detectors are employed for the acquisition of complex spectra, is demonstrated by determining normal values for 25 elements in bovine liver. Optimal conditions for the determination of Ag, Br, Cl, Co, Cs, Fe, I, K, Mn, Na, P, Rb, Sb, Sc, Se and Zn with the aid of instrumental thermal neutron activation analysis (INAA) by varying the irradiation and decay time are presented. Where INAA was inadequate, simple post irradiation separation based on ion-exchange has been used to determine such elements as Au, Ca, Cd, Ce, Cr, Cu, La, Mo and W. Results from the IAEA intercomparison run for animal muscle (H-4) are also given. The influence of sample size with respect to within-tissue variation of the bulk and trace elements in liver and the contamination of liver samples from the interfering components such as residual blood are also discussed.