Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Prosthesis Failure”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80Linked to original sources

Mechanical failure of the femoral component in cemented total hip replacement--a finite element evaluation.

The quality of cementation is of paramount importance for the long-term clinical outcome in cemented total hip replacement. Four "modes of failure" have been differentiated by various authors and correlated with the clinical findings. A finite element analysis was performed to simulate an ideally cemented femoral stem-type prosthesis as well as failure modes III (proximal anchorage of implant only) and IV (Distal anchorage of implant only). While failure mode III produces a stress distribution at the bone/acrylic cement interface, which is similar to the ideally cemented prosthesis, failure mode type IV leads to a hazardous rise of the interface stresses. This correlates well with the clinical findings given in the literature, thus validating the computer simulation used. Distal cementation only of a stem-type femoral component in total hip replacement should definitely be avoided.

Bone Cements↗

Analogue femurs for laboratory investigations of prosthesis stress distributions and fixation failures.

A polymeric analogue femur in combination with a brittle-coating stress-analysis technique was used to compare the relative femoral surface-strain distributions for various hip prostheses. The influence of prosthesis design factors, such as the geometry and material, the effect of a collar, and surface texturing, were readily ascertained and in agreement with previous investigations using other techniques. The fixation failures observed with this laboratory test model were similar to those of published clinical findings.

Bone Cements↗

Fracture of titanium plates used for mandibular reconstruction following ablative tumor surgery.

PURPOSE: The purpose of this study was to identify reasons for fracture of titanium mandibular reconstruction plates, when used to bridge lateral mandibular defects after ablative tumor surgery. MATERIALS AND METHODS: Sixteen titanium reconstruction plates from sheep mandibles were examined to identify reasons for the plate fractures. The broken plates and the seemingly unbroken plates were examined separately. The plates were removed from the mandibular bone and inspected by dye penetrant examination, metallography, optical microscope, scanning electron microscope, and energy dispersive X-ray spectrometer. Furthermore, axial load fatigue tests were performed in two different environments, air and physiologic salt solution, 0.9% NaCl, to compare titanium behavior in air and the human body. RESULTS: The site of crack initiation was the inner curvature of the reconstruction plate, and the cracks initiated as a result of stress concentration in the shoulder fillet of the plate. The cracks grew in a cyclic manner under masticatory loading of the mandible and the plate. The plate fracture occurred by means of fatigue. The corrosive environment did not affect the failure of the titanium plate, and the fracture was not caused by hydrogen embrittlement. The results revealed that the fatigue properties of the plates may have been impaired by the residual stresses generated in plate bending. CONCLUSIONS: Adjustive bending of the plates, in the surgical operation, may thus be an important cause of fracture of the reconstruction plates, because of generated residual stresses, which affect the mean stress in fatigue loading. To make the plates function without failure the plates should match closely with the three-dimensional shape of the mandible, to avoid any bending in the operative phase.

Animals↗

High migration rate of two types of threaded acetabular cups.

INTRODUCTION: Survivorship analysis was performed on 479 Link V-type threaded cups and on 110 modified V-type Bad Bramstedt cups (a modification of the Link V-type cup since 1993 with a smaller primary coil) to evaluate the effect of the modifications. MATERIALS AND METHODS: Indication for hip arthroplasty with a Link V-type cup was an inflammatory arthritis in 310 patients, osteoarthritis in 138 patients and dysplastic hip joints in 31 patients. The average follow-up was 8.6+/-3.2 (range 3.0-15.2) years. The 110 modified V-type Bad Bramstedt cups had a mean follow-up period of 4.5+/-0.7 (range 3.0-5.9) years, including 49 with inflammatory arthritis, 49 with osteoarthritis and 12 with dysplastic hip joints. To evaluate the migration rate and radiolucent lines, radiographical examination according to the method of Nunn et al. and Delee and Charnley was performed on 264 Link V-type cups with a mean follow-up period of 8.2+/-2.7 years and 59 modified V-type Bad Bramstedt cups with a mean follow-up period of 4.6+/-0.7 years. Relevant parameters influencing cup migration were analysed. RESULTS: The cumulative survival rate of the former Link V-type acetabular cup was 94.5% after 5 years, 88.1% after 10 years and 70.2% after 15 years. The Bad Bramstedt cup showed a 5-year survivorship rate of 97.9%. Migration of more than 3 mm or tilting of the cup greater than 5 degrees was found in 73% of the former type and in 39% of the modified cup. Radiolucent lines greater than 2 mm and detectable in two zones appeared in 6.4% of the former Link V-type and in 1.7% of the Bad Bramstedt cup design. Among the influencing factors analysed, length of follow-up and primary cup positioning showed a significant correlation to cup migration. CONCLUSION: The modification of the Link V-type cup showed no satisfactory improvement in cup migration. Therefore, both threaded cups were abandoned in favour of cementless press-fit cups.

Acetabulum↗

Computational wear prediction of a total knee replacement from in vivo kinematics.

Wear of ultra-high molecular weight polyethylene bearings in total knee replacements remains a major limitation to the longevity of these clinically successful devices. Few design tools are currently available to predict mild wear in implants based on varying kinematics, loads, and material properties. This paper reports the implementation of a computer modeling approach that uses fluoroscopically measured motions as inputs and predicts patient-specific implant damage using computationally efficient dynamic contact and tribological analyses. Multibody dynamic simulations of two activities (gait and stair) with two loading conditions (70-30 and 50-50 medial-lateral load splits) were generated from fluoroscopic data to predict contact pressure and slip velocity time histories for individual elements on the tibial insert surface. These time histories were used in a computational wear analysis to predict the depth of damage due to wear and creep experienced by each element. Predicted damage areas, volumes, and maximum depths were evaluated against a tibial insert retrieved from the same patient who provided the in vivo motions. Overall, the predicted damage was in close agreement with damage observed on the retrieval. The gait and stair simulations separately predicted the correct location of maximum damage on the lateral side, whereas a combination of gait and stair was required to predict the correct location on the medial side. Predicted maximum damage depths were consistent with the retrieval as well. Total computation time for each damage prediction was less than 30 min. Continuing refinement of this approach will provide a robust tool for accurately predicting clinically relevant wear in total knee replacements.

Aged↗

Design factors influencing performance of constrained acetabular liners: finite element characterization.

Constrained acetabular liners are utilized to deal with the infrequent but devastating problem of recurrent dislocation. While an encouraging treatment of last resort, the clinical performance of contemporary constrained liners has been somewhat mixed. There are multiple factors contributing to this variability, one of which is the limited understanding of the intrinsic mechanical characteristics of these specialty devices. To address this issue, a three-dimensional, materially nonlinear, multi-surface contact finite element model of a representative constrained liner was created. The model was physically validated, and then used for parametric testing to explore the effects of individual design features. The model was exercised for both intra-operative assembly and lever-out dislocation. It was found that the coefficient of friction between the femoral head and the liner substantially affected both the force required to seat the femoral head into the liner during assembly, and the peak moment resisting dislocation (226% increase in assembly force for friction coefficients of 0.2 versus 0.0; 49% reduction in dislocation moment for friction coefficients of 0.013 versus 0.135). As expected, the cup opening radius also had a dominant effect on both maneuvers: decreasing the opening radius from 13.9 to 13.6 mm increased assembly force by 506 N and increased the dislocation moment by over 3.5 N-m, whereas the influence of other design parameters was much more modest.

Acetabulum↗

The primary stability of a cementless stem varies between subjects as much as between activities.

The rehabilitation program adopted immediately after a cementless total hip replacement is a very important factor, because of the known relationship between osseointegration and implant micromotion. The present study was aimed to evaluate which type of task is the most critical in terms of bone-implant relative micromotion. Both inter-task and inter-subject variability were taken into account to verify if the movement strategy could be determinant on this assessment. A previously validated finite element model was used to predict the peak total micromovements over the entire bone-implant contact surface in four different patients, performing nine different tasks, using published data on joint forces recorded by instrumented hip prostheses. The results predicted by the various simulations suggest that while stair climbing is surely a critical task for primary stability, for some subjects other tasks may be as critical as stair climbing. From a variance analysis for simple crossover design on the predicted peak micromotion, the inter-subject variability had much more influence on the primary stability of cementless implant than the inter-task variability. Even if the results of Patient IBL, who was reported to have difficulties to perform any activities in a normal way, were excluded from the statistical analysis, the inter-subject variability remained still higher than the inter-task variability. The results obtained from simulations suggest that the strategy the hip replacement patient adopts to perform a given motor task, may be, for the implant stability, equally or even more critical than the type of motor task performed.

Cementation↗

Left ventricular assist devices: current status and future applications.

Despite the advances in the medical management of heart failure over the last 20 years it remains a major cause of morbidity and mortality. While cardiac transplantation has evolved into an established mode of therapy, the number of patients with severe heart failure who could benefit from cardiac transplantation far exceeds the supply of donor organs. The development of an implantable left ventricular assist device (LVAD) began in the early 1970s in centres such as the Texas Heart Institute and was funded by the National Heart, Lung, and Blood Institute. Clinical trials of these devices began in the mid 1980s and several hundred patients have now been supported with one or other of these devices. Most patients have had an LVAD implanted as a bridge to cardiac transplantation. Recently there has also been interest in the use of an LVAD for (a) permanent ventricular support and (b) as a bridge to recovery in patients with potentially reversible causes of heart failure.

Heart Failure↗

Bridge to transplantation with the Jarvik-7 (CardioWest) total artificial heart: a single-center 15-year experience.

BACKGROUND: At our institution, the total artificial heart (TAH) Jarvik-7 (CardioWest) has been used since 1986 as a bridge to transplantation for the most severely ill patients with terminal congestive heart failure. METHODS: Between 1986 and 2001, 127 patients (108 males, mean age 38 +/- 13) were bridged to transplantation with the Jarvik-7 TAH. All were in terminal biventricular failure despite high-dose inotropic support. Nine patients had a body surface area (BSA) of <1.6 m(2). In Group I patients (78%), the etiology of cardiac failure was dilated cardiomyopathy, either idiopathic (n = 60) or ischemic (n = 38). The other 29 patients (Group II) had disease of miscellaneous origin. We analyzed our experience with regard to 3 time periods: 1986 to 1992 (n = 63); 1993 to 1997 (n = 36); and 1998 to 2001 (n = 33). RESULTS: Although Group II patients represented 30% of indications before 1992, they comprised only 15% during the 2 subsequent periods. Duration of support for transplant patients increased dramatically after 1997, reaching 2 months for the most recent period (5 to 271 days). In Group I, the percentage of transplanted patients increased from 43% before 1993 to 55% between 1993 and 1997, and reached 74% thereafter. The major cause of death was multiorgan failure (67%). The clinical thromboembolic event rate was particularly low with no instance of cerebrovascular accident and 2 transient ischemic attacks. Total bleeding complication rate was 26%, including 2 deaths related to intractable hemorrhage and 2 others related to atrial tamponade. The cumulative experience was 3,606 total implant days with only 1 instance of mechanical dysfunction. CONCLUSIONS: TAH is a safe and efficient bridge for patients with terminal congestive heart failure awaiting cardiac transplantation.

Adolescent↗

Failed cementless total knee arthroplasty presenting as osteolysis of the fibular head.

Large osteolytic lesions can occur adjacent to cementless total knee arthroplasty components. This occurrence frequently is related to suboptimal design features leading to the generation of metal or polyethylene wear debris. Occasionally, such lesions can mimic a bone tumor. A case of a lytic lesion of the fibular head adjacent to a failed cementless knee arthroplasty is described along with a description of the damaged retrieved component that led to the failure.

Fibula↗

The effects of hydroxyapatite coating and bone allograft on fixation of loaded experimental primary and revision implants.

We used our established experimental model of revision joint replacement to examine the roles of hydroxyapatite coating and bone graft in improving the fixation of revision implants. The revision protocol uses the Søballe micromotion device in a preliminary 8-week period of implant instability for the presence of particulate polyethylene. During this procedure, a sclerotic endosteal bone rim forms, and a dense fibrous membrane is engendered, having macrophages with ingested polyethylene and high levels of inflammatory cytokines. At the time of revision after 8 weeks, the cavity is revised with either a titanium alloy (Ti) or a hydroxyapatite (HA) 6.0 mm plasma-sprayed implant, in the presence or absence of allograft packed into the initial 0.75 mm peri-implant gap. The contralateral limb is subjected to primary surgery with the same implant configuration, and serves as control. 8 implants were included in each of the 8 treatment groups (total 64 implants in 32 dogs). The observation period was 4 weeks after revision. Outcome measures are based on histomorphometry and mechanical pushout properties. The revision setting was always inferior to its primary counterpart. Bone graft improved the revision fixation in all treatment groups, as also did the HA coating. The sole exception was revision-grafted HA implants, which reached the same fixation as primary Ti and HA grafted implants. The revision, which was less active in general, seems to need the dual stimulation of bone graft and HA implant surface, to obtain the same level of fixation associated with primary implants. Our findings suggest that the combination of HA implant and bone graft may be of benefit in the clinical revision implant setting.

Animals↗

Assessment of polyethylene wear in total hip replacement.

The three-dimensional technique is a method for the measurement of polyethylene wear in patients with total hip joint replacement. Application of image processing technology allows automation of point selection from digital images of radiographs scanned into the computer. Validation of image processing modifications reveals a three-fold increase in accuracy and a 40-fold increase in reproducibility compared with manual input of points from a digitizer during bench testing. A review of three-dimensional technique application to clinical patients gives information on the factors that influence polyethylene wear. Increasing age, activity level, femoral head size, decreasing polyethylene thickness, and insertion of total hip prostheses without cement all increase polyethylene wear. Restoration of femoral offset during total hip replacement seems to decreases polyethylene wear. No apparent difference in polyethylene wear rate could be found between two groups of patients, one group had a stainless steel-polyethylene articulation and the other had a ceramic-polyethylene articulation. Measurement of the serial polyethylene wear of individual patients reveals a high rate of femoral head penetration during the first 2 years after total hip replacement using metal-backed acetabular components inserted without cement. Interpretation of this femoral head penetration as true polyethylene wear may be erroneous, however, because creep of the polyethylene and acetabular liner movement within its metal shell cannot be measured.

Arthroplasty, Replacement, Hip↗

The causes of insert backside wear in total knee arthroplasty.

Wear of the insert backside occurs ostensibly because of micromotion at the undersurface articulation that occurs with loading. When a cyclic axial load was applied to contemporary knee implants, all inserts tested moved 2 to 25 microm in the shear plane relative to the metal backing suggesting that undersurface motion may be inevitable. Variables that increase the forces between the insert and metal backing can worsen relative micromotion and backside wear. Forces at the undersurface articulation, created during physiologic loading, are influenced by insert type, articular design, and surgical technique. Increasing articular insert constraint can cause forces at the main articulation to be resisted and transferred to this and the other interfaces. Designs with a cam post mechanism that force rollback at a certain flexion angle create a significant force in this shear plane. Inserts with highly conforming articular geometries can have a similar affect if used to inhibit anteroposterior or mediolateral motion of the femur on the tibial insert. Component alignment and position, and ligament balance also may influence backside wear as suggested by the great variability of wear patterns seen on like insert retrievals and by kinematic differences observed in fluoroscopic studies of the same implant design. Only by understanding these potential causes of backside motion and subsequent wear, can backside wear be mitigated.

Arthroplasty, Replacement, Knee↗

Femoral revision with impaction grafting and a collarless, polished, tapered stem.

Femoral impaction allografting has been done with and without variations of the original description. The purpose of this study was to review Harris hip scores, radiographs, and complications in patients in whom we used the original technique without significant modifications. Preoperative and postoperative hip scores and radiographic data were available at a mean of 4.7 years for 43 of 44 hips that had femoral component impaction allografting with a collarless, polished, tapered stem. Bone stock was classified according to the Endo-Klinik classification. Survivorship, using femoral reoperation for symptomatic aseptic loosening as the end point, was 97%. The mean Harris hip score improved from 45 to 90 with pain improved in all. Subsidence 4 mm and greater occurred in only two hips, but neither has been revised. One hip was revised for mechanical loosening after a fall on the surgically treated extremity 6 years after surgery. Complications included three intraoperative fractures, one femoral fracture recognized postoperatively, one trochanteric nonunion, and one dislocation. Femoral component revision with impaction allografting and a collarless, polished, tapered stem was reproducible and improved Harris hip scores in patients with aseptic femoral component loosening and bone loss at a mean of 4.7 years after surgery.

Adult↗

The effect of divergent screw placement on the initial strength of plate-to-bone fixation.

BACKGROUND: Numerous implants exist that allow screws to be placed at varying angles for lag fixation or to fix additional fragments. This study determined how placing screws at different angles affects fixation strength. METHODS: Using a bone model, we first investigated the pullout strength of screws inserted at varying angles; then, we studied the strength of plate-bone constructs with end screws placed at divergent angles. RESULTS: Varying the screw angle from 0 to 10 to 20 degrees progressively weakened the screw pullout resistance. No additional decrease was found in varying the angle further. In contrast, the strength of fixation of plate to bone was higher for constructs with screws placed at 20 or 30 degrees off of perpendicular when tested in gap-open bending and axial compression (all p < 0.05). No such differences were found in torsion. CONCLUSION: The pullout strength with angled screws is reduced, but this does not translate into reduced strength of the bone-to-plate interface.

Analysis of Variance↗

Long-term ventricular wall actuation: can and should it be systematically explored?

Hearts fail because myocardial power fails. Assist, support, or replacement devices fail, at least in part, because their blood-contacting surfaces fail. Mechanical repowering of a failing heart might circumvent these difficulties by preserving a largely healthy endocardium while correcting the basic deficit, power. Any serious consideration of doing this though must confront some difficult requirements. Effective indefinite support must be coupled with preservation or restoration of valve competence, coronary flow, rapid low-impedance refilling and independent left and right pressures; the avoidance of wall coaptation; hardware that fits in the available space; and unless muscle powered, adaptability to a deliverable form of power. Despite earlier intense interest in acute mechanical devices and later empiric study of muscle wraps, little systematic methodical work has been done on elucidating and meeting these practical requirements. Concerted efforts toward developing research tools and techniques for their study and then finding mechanisms to meet them could well yield one or more effective modalities that circumvent a major obstacle to the indefinite mechanical treatment of heart failure.

Animals↗

Simulation of fretting wear at orthopaedic implant interfaces.

Osteolysis due to wear debris is a primary cause of failure of total joint replacements. Although debris produced by the joint articulating surfaces has been studied and simulated extensively, fretting wear debris, produced at nonarticulating surfaces, has not received adequate attention. We developed a three-station fretting wear simulator to reproduce in vivo motion and stresses at the interfaces of total joint replacements. The simulator is based on the beam bending theory and is capable of producing cyclic displacement from 3 to 1000 microns, under varying magnitudes of contact stresses. The simulator offers three potential advantages over previous studies: The ability to control the displacement by load, the ability to produce very small displacements, and dynamic normal loads as opposed to static. A pilot study was designed to test the functionality of the simulator, and verify that calculated displacements and loads produced the predicted differences between two commonly used porous ingrowth titanium alloy surfaces fretting against cortical bone. After 1.5 million cycles, the simulator functioned as designed, producing greater wear of bone against the rougher plasma-sprayed surface compared to the fiber-mesh surface, as predicted. A novel pin-on-disk apparatus for simulating fretting wear at orthopaedic implant interfaces due to micromotion is introduced. The test parameters measured with the fretting wear simulator were as predicted by design calculations, and were sufficient to measure differences in the height and weight of cortical bone pins rubbing against two porous ingrowth surfaces, plasma-sprayed titanium and titanium fiber mesh.

Cadaver↗