Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MONITORING SYSTEMS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80Linked to original sources

Highly sensitive cell-based assay system to monitor the sialyl Lewis X biosynthesis mediated by alpha1-3 fucosyltransferase-VII.

The sialyl Lewis X (sLe(x)) determinant on leukocytes serves as a ligand for selectin family cell adhesion molecules, and selectin-carbohydrate interaction is considered to play an important role in the process of leukocyte extravasation during inflammation. Among several alpha1-3 fucosyltransferases (FucTs), FucT-VII plays a critical role in the biosynthesis of sLe(x)-epitopes. Therefore, small molecules specifically designed to inhibit the FucT-VII enzyme may have potential as anti-inflammatory agents. Here, we have developed a versatile cell-based assay system to monitor sLe(x) biosynthesis using the GeneSwitch System. This system is a mifepristone (MFP)-inducible mammalian expression system, and human transfectant T lymphoblasts expressed the mRNA of FucT-VII and the sLe(x)-epitopes on the cell surface in a time-dependent manner in the presence of MFP, with very low background transcription. Furthermore, when the transfectants were treated with the FucT-VII inhibitor panosialin, sLe(x) expression on the induced cells was inhibited dose dependently without alteration at the mRNA level of FucT-VII. These results suggest that the FucT-VII may be a major regulator of the biosynthesis of the sLe(x)-epitopes on T lymphoblasts, and this cell-based assay may be utilized for a screening system of FucT-VII inhibitors.

Animals↗

Initial experience of using a knowledge based system for monitoring immunization services in Papua New Guinea.

A knowledge based system (KBS) which helps health service managers to interpret immunization coverage rates was installed in two provinces of Papua New Guinea. It was assessed over a period of 4 months to determine whether it was a potentially useful management tool. One province used the system but did not adjust its activities significantly because it was meeting its targets for immunization. In the other province the KBS helped provincial managers to detect problems and respond to them. Consequently, improvements in performance indicators were detected. It is difficult to attribute the improvements entirely to the KBS but several actions were taken to strengthen immunization services and the KBS appeared to support these. It appears that interventions which make routinely collected data more understandable and readily usable by health service managers can lead to improvements in the delivery of health services.

Follow-Up Studies↗

Viability of interceptor trenches for monitoring groundwater quality near landfills.

Computer models were used to quantify the detection capability of four alternative groundwater monitoring systems in a shallow aquifer near a 50-m by 75-m landfill oriented oblique to groundwater flow. The monitoring systems included a network of five wells, and 1-m, 3-m, and 5-m wide gravel interceptor trenches. Each trench was 42-m long. Wells and trenches were positioned on a monitoring locus located 15-m, in the direction parallel to groundwater flow, from the landfill's downgradient boundary. There was an equal spacing, in the direction perpendicular to groundwater flow, between monitoring wells, and the trenches were positioned near the middle of the monitoring transect. The five-well network detected 81% of contaminant plumes originating within the landfill's footprint before they reached a buffer zone boundary located 50-m from the landfill's downgradient corner. By comparison, the 1-m, 3-m, and 5-m wide trenches detected 77, 84, and 88% of the contaminant plumes, respectively. Convergent flow induced by wider trenches yielded slightly higher detection efficiencies. Although the well and trench monitoring systems registered similar detection capability, estimated costs for installing the trench systems were more than 10 times those of constructing the wells. Overall, results of this study suggest that, even for shallow aquifers, gravel interceptor trenches are not a cost effective method for detecting leaks from landfills.

Computer Simulation↗

Patient data system for monitoring shunts.

Rapidly locating accurate data on a patient's shunt system is often extremely difficult. We have developed a simple system to fill a perceived need for recording current data on a patients shunt. This system employs an easily updated record in the patient's hospital or clinic chart as well as a wallet-sized data card for the patient or his family to carry. The data in the chart include the configuration of the patient's current shunt system and a graphic record of previous shunt problems. The small patient data card describes the age of the shunt system and its current configuration. We have found that this system provides assistance in the routine follow-up of patients with shunts and plays an extremely necessary role in the emergency evaluation of these patients, particularly when an emergency evaluation is undertaken in facilities distant from the location of regular treatment.

Adolescent↗

Building data systems for monitoring and responding to violence against women. Recommendations from a workshop.

This report provides recommendations regarding public health surveillance and research on violence against women developed during a workshop, "Building Data Systems for Monitoring and Responding to Violence Against Women." The Workshop, which was convened October 29-30, 1998, was co-sponsored by the U.S. Department of Health and Human Services and the U.S. Department of Justice.

Adolescent↗

[Audiobase--a computer system for monitoring and analyzing audiometric data in clinical and ambulatory practice].

The amount of data in the field of otorhinolaryngology has rapidly increased in proportion to the growing number of patients. It is a very important issue to preserve their records and make them easily available. Authors present a computer-based system for monitoring audiometric data of hearing impaired persons named Audiobase. The main elements of this system as: the personal data, otoscopic and audiometric examination have been described. This system was created to be used by staff without computer skills and therefore is largely "icon-driven". The main functions include patient record creation, update, and retrieval, as well as the generating of reports and graphical presentations. The system has already provided useful research material and is now beginning to fulfill an even more important role in patient follow-up and in evaluation of alternative treatment protocols.

Ambulatory Care↗

Surveillance systems for monitoring the development of spatial patterns.

Statistical methods concerned with the identification of temporal patterns may be classified into those that examine retrospectively a set of observations, and those that constitute surveillance systems that monitor changes as new observations become available. A similar distinction applies to the identification of geographical patterns in spatial data. There has been a notable lack of attention given to the surveillance of spatial pattern. This paper concerns development of a cumulative sum statistic and procedure for the monitoring of spatial pattern, and its application to both simulated data and to data on Burkitt's lymphoma in Uganda.

Adolescent↗

A system for monitoring heart pulse, respiration and posture in bed.

A non-invasive system has been developed to monitor cardiac vibrations, respiration and posture of inbed hospitalized patients and elderly people who need constant care. These physiological variables are recorded by four 2 x 28 cm piezoelectric film acceleration sensors, eight 2 x 2 cm small pressure sensors and a 5 x 100 cm long pressure sensor. The piezoelectric sensors, attached to the chest over the heart during bed sleep or rest, detect the movements produced by the heartbeat and respiration. The eight small pressure sensors are attached at various positions on the upper and lower body. A longer pressure sensor, to detect the patient leaving the bed, is attached to the side of the bed. These sensor outputs are digitized at a sampling rate of 200 Hz using a 12-bit A/D converter and stored on a personal computer. The computer detects cardiac vibrations and respiration from upper chest movements and posture from the pressures recorded by small and long pressure sensors.

Bed Rest↗

Admissions monitoring and scheduling to improve work flow in hospitals.

As part of a five-year effort to evaluate alternative methods of improving nurse productivity, this study was undertaken to better understand work flow monitoring as a technique for stabilizing staffing patterns and to improve productivity in hospitals. Two admissions scheduling and monitoring systems were studied and compared with an admissions system without an explicit monitoring function in three medical-surgical units of a 641-bed community hospital. The admissions system based on monitoring case mix was found to be more effective than the system based on monitoring census. Both were significantly more effective than the admissions system without an explicit monitoring function.

Admitting Department, Hospital↗

Frequency response evaluation of radial artery catheter-manometer systems: sinusoidal frequency analysis versus flush method.

It is well recognized that catheter-manometer systems significantly distort direct radial artery pressure measurements. Sinusoidal frequency analysis and the flush method of assessing the degree of distortion caused by the monitoring system were compared to determine whether these two methods agree in the estimation of natural frequency and damping coefficient. The frequency response of 30 radial artery catheter-manometer systems used for intensive-care unit patients was measured by the flush method and sinusoidal frequency analysis. The monitoring system consisted of a 20-gauge cannula, 150-cm pressure tubing, two plastic stopcocks, a continuous infusion device with fast flush valve, an American Edwards dome, a Hewlett-Packard quartz transducer, and a Hewlett-Packard blood pressure amplifier. Sinusoidal frequency analysis demonstrated second-order underdamped response for all 30 catheter-manometer systems. No secondary resonance peaks were observed up to a frequency of 200 Hz. The measured frequency response demonstrated that the average catheter-manometer system in use in our intensive care unit would cause significant distortion of the radial artery pressure, with the mean natural frequency (fn) of 14.7 +/- 3.7 Hz and the mean damping coefficient (zeta) of 0.24 +/- 0.07. Although the 30 monitoring systems had identical configurations and visible bubbles were carefully removed, a wide range of frequency responses was found (fn = 10.2 to 25.3; zeta = 0.15 to 0.44).(ABSTRACT TRUNCATED AT 250 WORDS)

Arm↗

Optimized procedure of real-time systemic leakage monitoring during isolated limb perfusion using a hand held gamma probe and 99mTc-HSA.

Isolated limb perfusion (ILP) therapy using a combination of tumour necrosis factor alpha (TNF) and cytostatic agents in hyperthermic conditions has proven to be effective in treating cancers limited to limbs or to a single organ such as the liver. A critical step for ILP is the accurate and real-time monitoring of that TNF toxic effects become relevant when overcoming the 10% limit of the 'effective' therapeutic dose administered during ILP. The most diffuse procedure for systemic leakage monitoring is based on the utilization of human soluble serum albumin (HSA) labelled with 131I and an external scintillation detector. In order to overcome some drawbacks connected with the properties of 131I, we developed a new procedure based on the utilization of HSA labelled with 99mTc in combination with a hand held gamma probe used as a detector. Our procedure consists of the following steps: (1) a 99mTc-HSA dose standardized as 0.5 MBq x kg(-1) body weight is injected into the ILP circuit before TNF administration; (2) a hand held gamma probe is placed over the pre-cordial area in a zone pre-marked on the patient's skin during a simulation test; (3) 48-72 h before ILP, a simulation test is obtained using a 99mTc-HSA dose corresponding to 10% of the dose calculated for ILP (i.e., 0.05 MBq x kg(-1) body weight); (4) during the simulation test the maximum count-rate zone detected on the pre-cordial area is marked on patient's skin; (5) a 60 min time-activity curve corresponding to the circulating 99mTc-HSA radioactivity effective decay is calculated and fitted; and (6) this time-activity curve is used to compensate for the leakage systemic counting observed during ILP. In order to compare the external, probe counting with the circulating radioactivity, in the first 10 patients from a total series of 43 treated patients, the results of external, probe monitoring were compared with the results of patient blood and perfusion circuit samples taken simultaneously every 5 min and measured by a laboratory gamma counter placed in the operating theatre. A good correlation was found between the two methods (R2 = 0.965, P < 0.01). It is concluded that the proposed procedure, based on the combination of 99mTc-HSA as the radiotracer and a hand held gamma probe as the detector, appears to be technically simple and accurate enough in the real-time monitoring of perfusion leakage in ILP cancer therapy. Moreover, using 99mTc-HSA as the radiotracer, the risk of radioactive contamination is significantly lower in comparison with 131I-HSA.

Antineoplastic Agents↗

Signal processing for damage detection using two different array transducers.

This work describes an investigation into the development of a new health monitoring system for aeronautical applications. The health monitoring system is based on the emission and reception of Lamb waves by multi-element piezoelectric transducers (i.e., arrays) bonded to the structure. The emitter array consists of three different elementary bar transducers. These transducers have the same thickness and length but different widths. The receiver array has 32 same elements. This system offers the possibility to understand the nature of the generated waves and to determine the sensitivity of each mode to possible damage. It presents two principal advantages: Firstly, by exciting all elements in phase, it is possible to generate several Lamb modes in the same time. Secondly, the two-dimensional fourier transform (2D-FT) of the received signal can be easily computed. Experimental results concerning an aluminum plate with different hole sizes will be shown. The A0-, S0-, A1-, S1- and S2-modes are generated at the same time. This study shows that the A0 mode seems particularly interesting to detect flaws of this geometrical type.

Journal Article↗

A mental health program report card: a multidimensional approach to performance monitoring in public sector programs.

This report presents a comprehensive, multi-dimensional mental health program performance monitoring system that has recently been implemented in the Department of Veterans Affairs. Principles underlying the development of the system are reviewed and 68 specific monitors are described addressing four major performance domains: access, inpatient care, outpatient care, and economic performance. Simple methods are presented for identifying outliers, for generating summary performance scores across series' of related monitors, and for adjusting results for differences in patient characteristics across locales. Although still technically imperfect, and therefore requiring continuous improvement, monitoring systems such as the one presented can be useful tools guiding and improving service delivery and mental health system performance, and providing a medium of accountability to consumers and other stakeholders.

Community Mental Health Centers↗

Evaluation of environmental monitoring strategies.

In environmental monitoring, it is important that the monitoring system should emit early warnings when undesired events occur. These events may be sudden or of a more subtle nature. In the design of such monitoring systems, a proper balance between cost and risk must be achieved. There are 2 classic types of risk connected with early warning systems, namely the risk of not detecting significant changes and the risk of false alarms. The purpose of this paper is to describe a method for comparing the performance of different monitoring systems, considering the classic types of risk and cost. The method is applied to the monitoring of the lichen cover as a test case. The expected utility has been used as a measure of performance. When estimating the probabilities of the events, spatial microsimulation and Monte-Carlo simulation techniques have been used. The monitoring programs studied are based on satellite images, aerial photos, field samples, and land-cover maps. The major conclusions of this study are that standardized quality measures are extremely useful for evaluating the usability of environmental monitoring methods. In addition, when estimating gains and costs, spatial microsimulation techniques are useful. To improve the method, however, macroconstraints should also be used for aligning the simulation model.

Environmental Monitoring↗

The measurement and monitoring of surgical adverse events.

BACKGROUND: Surgical adverse events contribute significantly to postoperative morbidity, yet the measurement and monitoring of events is often imprecise and of uncertain validity. Given the trend of decreasing length of hospital stay and the increase in use of innovative surgical techniques--particularly minimally invasive and endoscopic procedures--accurate measurement and monitoring of adverse events is crucial. OBJECTIVES: The aim of this methodological review was to identify a selection of common and potentially avoidable surgical adverse events and to assess whether they could be reliably and validly measured, to review methods for monitoring their occurrence and to identify examples of effective monitoring systems for selected events. This review is a comprehensive attempt to examine the quality of the definition, measurement, reporting and monitoring of selected events that are known to cause significant postoperative morbidity and mortality. METHODS - SELECTION OF SURGICAL ADVERSE EVENTS: Four adverse events were selected on the basis of their frequency of occurrence and likelihood of evidence of measurement and monitoring: (1) surgical wound infection; (2) anastomotic leak; (3) deep vein thrombosis (DVT); (4) surgical mortality. Surgical wound infection and DVT are common events that cause significant postoperative morbidity. Anastomotic leak is a less common event, but risk of fatality is associated with delay in recognition, detection and investigation. Surgical mortality was selected because of the effort known to have been invested in developing systems for monitoring surgical death, both in the UK and internationally. Systems for monitoring surgical wound infection were also included in the review. METHODS - LITERATURE SEARCH: Thirty separate, systematic literature searches of core health and biomedical bibliographic databases (MEDLINE, EMBASE, CINAHL, HealthSTAR and the Cochrane Library) were conducted. The reference lists of retrieved articles were reviewed to locate additional articles. A matrix was developed whereby different literature and study designs were reviewed for each of the surgical adverse events. Each article eligible for inclusion was independently reviewed by two assessors. METHODS - CRITICAL APPRAISAL: Studies were appraised according to predetermined assessment criteria. Definitions and grading scales were assessed for: content, criterion and construct validity; repeatability; reproducibility; and practicality (surgical wound infection and anastomotic leak). Monitoring systems for surgical wound infection and surgical mortality were assessed on the following criteria: (1) coverage of the system; (2) whether or not denominator data were collected; (3) whether standard and agreed definitions were used; (4) inclusion of risk adjustment; (5) issues related to data collection; (6) postdischarge surveillance; (7) output in terms of feedback and wider dissemination. RESULTS - SURGICAL WOUND INFECTION: A total of 41 different definitions and 13 grading scales of surgical wound infection were identified from 82 studies. Definitions of surgical wound infection varied from presence of pus to complex definitions such as those proposed by the Centres for Disease Control in the USA. A small body of literature has been published on the content, criterion and construct validity of different definitions, and comparisons have been made against wound assessment scales and multidimensional indices. There are examples of comprehensive hospital-based monitoring systems of surgical wound infection, mainly under the auspices of nosocomial surveillance. To date, however, there is little evidence of systematic measurement and monitoring of surgical wound infection after hospital discharge. RESULTS - ANASTOMOTIC LEAK: Over 40 definitions of anastomotic leak were extracted from 107 studies of upper gastrointestinal, hepatopancreaticobiliary and lower gastrointestinal surgery. No formal evaluations were found that assessed the validity or reliability of definitions or severity scales of anastomotic leak. One definition was proposed during a national consensus workshop, but no evidence of its use was found in the surgical literature. The lack of a single definition or gold standard hampers comparison of postoperative anastomotic leak rates between studies and institutions. RESULTS - DEEP VEIN THROMBOSIS: Although a critical review of the DVT literature could not be completed within the realms of this review, it was evident that a number of new techniques for the detection and diagnosis of DVT have emerged in the last 20 years. The group recommends a separate review be undertaken of the different diagnostic tests to detect DVT. RESULTS - SURGICAL MORTALITY MONITORING SYSTEMS: The definition of surgical mortality is relatively consistent between monitoring systems, but duration of follow-up of death postdischarge varies considerably. The majority of systems report in-hospital mortality rates; only some have the potential to link deaths to national death registers. Risk assessment is an important factor and there should be a distinction between recording pre-intervention factors and postoperative complications. A variety of risk scoring systems was identified in the review. Factors associated with accurate and complete data collection include the employment of local, dedicated personnel, simple and structured prompts to ensure that clinical input is complete, and accurate and automated data capture and transfer. CONCLUSIONS: The use of standardised, valid and reliable definitions is fundamental to the accurate measurement and monitoring of surgical adverse events. This review found inconsistency in the quality of reporting of postoperative adverse events, limiting accurate comparison of rates over time and between institutions. The duration of follow-up for individual events will vary according to their natural history and epidemiology. Although risk-adjusted aggregated rates can act as screening or warning systems for adverse events, attribution of whether events are avoidable or preventable will invariably require further investigation at the level of the individual, unit or department. CONCLUSIONS - RECOMMENDATIONS FOR RESEARCH: (1) A single, standard definition of surgical wound infection is needed so that comparisons over time and between departments and institutions are valid, accurate and useful. Surgeons and other healthcare professionals should consider adopting the 1992 Centers for Disease Control (CDC) definition for superficial incisional, deep incisional and organ/space surgical site infection for hospital monitoring programmes and surgical audits. There is a need for further methodological research into the performance of the CDC definition in the UK setting. (2) There is a need to formally assess the reliability of self-diagnosis of surgical wound infection by patients. (3) There is a need to assess formally the reliability of case ascertainment by infection control staff. (4) Work is needed to create and agree a standard, valid and reliable definition of anastomotic leak which is acceptable to surgeons. (5) A systematic review is needed of the different diagnostic tests for the diagnosis of DVT. (6) The following variables should be considered in any future DVT review: anatomical region (lower limb, upper limb, pelvis); patient presentation (symptomatic, asymptomatic); outcome of diagnostic test (successfully completed, inconclusive, technically inadequate, negative); length of follow-up; cost of test; whether or not serial screening was conducted; and recording of laboratory cut-off values for fibrinogen equivalent units. (7) A critical review is needed of the surgical risk scoring used in monitoring systems. (8) In the absence of automated linkage there is a need to explore the benefits and costs of monitoring in primary care. (9) The growing potential for automated linkage of data from different sources (including primary care, the private sector and death registers) needs to be explored as a means of improving the ascertainment of surgical complications, including death. This linkage needs to be within the terms of data protection, privacy and human rights legislation. (10) A review is needed of the extent of the use and efficiency of routine hospital data versus special collections or voluntary reporting.

Humans↗

A microcomputer controlled system for monitoring multiple voltammetric electrodes in vivo.

An inexpensive multielectrode voltammetry system designed for in vivo neurochemical studies of the awake, unanesthetized primate has been developed. Consisting of an Apple II Plus microcomputer, parallel operational amplifier circuitry for six working electrodes, and commercially available interface boards, the system has the flexibility to implement many standard voltammetric procedures under total software control. Multielectrode monitoring is accomplished essentially simultaneously, and all channels are equipped with independent gain controls allowing for rapid amplification adjustment. An interactive chronoamperometry program, capable of making rapid 12 bit analog to digital conversions for each working electrode over four software selectable ranges, is described and system performance is evaluated.

Animals↗

Novel system for monitoring autophagy in the yeast Saccharomyces cerevisiae.

The yeast S. cerevisiae imports cytosolic components into the vacuole non-selectively by autophagy and degrades them by vacuolar hydrolases under nutrient starvation conditions. We developed a novel system for monitoring autophagy by constructing cells in which modified vacuolar alkaline phosphatase is expressed as an inactive precursor form in the cytosol. Under starvation conditions, the processing of the precursor to the mature form and phosphatase activity appeared gradually, and the mature form was located in the vacuole. Disruption of APG1, an essential gene for autophagy, resulted in no processing or phosphatase activity. These results indicate that the precursor form in the cytosol is transferred to the vacuole by autophagy and converted to the active form by vacuolar proteinases. Thus, autophagy could be determined easily and accurately by measuring the phosphatase activity.

Alkaline Phosphatase↗

A system for monitoring arterial oxygen tension in sick newborn babies.

The measurement of arterial oxygen tension (PaO2) has for some time now been regarded as an essential part of the management of newborn babies receiving oxygen therapy. A system for monitoring arterial oxygen tension by means of a catheter-tip transducer is described. Comparisons of the transducer output with PO2 obtained by blood sample analysis are discussed. Up to the present time the PaO2 of more than sixty sick newborn babies have been monitored using these transducers in the Neonatal Unit at University College Hospital. The results obtained with these transducers in the first eighteen babies are reported in detail and demonstrate the possibility of continuous, reliable measurement of PaO2 under routine clinical conditions.

Catheterization↗