Non-union of the epiphysis of the lateral condyle of the humerus.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
From 1982 to 1987 we treated 85 extra-articular comminuted distal third humeral fractures in adults with prefabricated plastic braces. Of these, 15% were open fractures and 18% had initial peripheral nerve injury. On average, the sleeve was applied 12 days after injury and used for 10 weeks. There was 96% union, with no infections. All nerve injuries resolved or were improving at the latest examination. At union there was varus deformity averaging 9 degrees in 81% of patients, but loss of range of movement was minimal and functional results were good.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND: Recreation of normal anatomical relationships may be important to optimize the outcome of proximal humeral arthroplasty. With use of computerized tomographic data and three-dimensional computer modeling, we concurrently studied both extramedullary and intramedullary humeral morphology, including canal shape, and related these findings to the design of proximal humeral prostheses. METHODS: Sixty cadaveric humeri (thirty pairs: fifteen from male donors and fifteen from female donors) were studied. Three-dimensional computer models were built from canal and periosteal contours extracted from computerized tomographic data and multiple measured anatomical parameters, including humeral canal axis, humeral head center, and hinge point offset; greater tuberosity and bicipital groove offset; humeral head center, radius, thickness, retroversion, and inclination; and size and torsion of sections of the canal. RESULTS: On the average, the humeral head center was offset both medially (seven millimeters) and posteriorly (two millimeters) from the humeral axis. The humeral head hinge point did not line up with the axis but instead was laterally offset by an average of seven millimeters. The average humeral head thickness was nineteen millimeters. The humeral head thickness and length were proportionately linked. There was marked variability in all of these parameters. Humeral head inclination averaged 41 degrees but was less variable than previously described, with 95 percent of our sample within the range of 35 to 46 degrees. The proximal section of the humeral canal was retroverted, and the retroversion was found to be similar to that of the humeral head on statistical analysis. Version of the middle and distal sections of the canal, however, was dissimilar to that of the proximal section of the canal. Proximal humeral retroversion was found to be extremely variable and averaged 19 degrees. The accuracy, reliability, and repeatability of the computer-based-model measurements were found to be excellent. CONCLUSIONS: Measurements of external proximal humeral morphology made with three-dimensional computer models of cadaveric specimens derived from the Midwestern United States agreed, in general, with those described for different populations evaluated with different measuring techniques. Proximal humeral morphology was extremely variable as highlighted by the large ranges of measurements seen for all variables. Examination of the intramedullary morphology showed that there is an internal version, with measurements dependent on the canal distance distal to the anatomical neck. CLINICAL RELEVANCE: Because of the marked variabilities seen in proximal humeral morphology, newer prosthetic designs are now allowing surgeons to control multiple prosthetic variables. An understanding of the normal values for proximal humeral morphology can serve as an important guideline for component selection, especially when the normal anatomy is distorted. Additionally, variations in intramedullary version may have important consequences for future designs of press-fit proximal humeral replacement.
BACKGROUND: There are limited reconstructive options for the treatment of segmental bone defects of the upper extremity that are >6 cm in length, especially those that are associated with soft-tissue defects. The purpose of the present review was to report on our experience with fifteen patients who received an osteoseptocutaneous fibular transplant for reconstruction of a humeral defect. METHODS: The study cohort included eight male patients and seven female patients with an average age of forty-one years. The indications for the procedure included segmental nonunion (nine patients), a gunshot wound (three), a defect at the site of a tumor resection (two), and failure of an allograft-prosthesis reconstruction (one). The fibular graft was fixed by means of intramedullary impaction in eleven patients, was used as an onlay graft in three, and was used as a strut between the intact diaphysis and the humeral head in one. RESULTS: The average length of the segmental humeral defect was 9.3 cm. The average length of the fibular graft was 16.1 cm, and the average length and width of the skin paddle were 8.1 and 4.5 cm. The average duration of follow-up was twenty-four months. Three patients had venous thrombosis and underwent a successful revision of the anastomosis. Four patients had early failure of graft fixation. Three patients had a fracture of the fibular graft within the first year postoperatively. All but one of these latter seven patients were successfully treated with open reduction, internal fixation, and additional bone-grafting. One patient with an infection at the site of a nonunion and signs of graft resorption required a second fibular transplant. CONCLUSIONS: The osteoseptocutaneous fibular transplant is an effective treatment for combined segmental osseous and soft-tissue defects of the arm. However, the application of this technique to the arm is more complex than application to the forearm and is associated with a higher rate of complications.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The complex nature of the ossification centers makes elbow injuries in a child or adolescent difficult to evaluate. The medial epicondylar ossification center is involved in a significant proportion. Injuries vary from simple avulsions to wide displacement with entrapment in the elbow. When entrapment occurs, it may be mistaken for the trochlear ossification center and the true nature of the injury overlooked. Radiographic findings are presented. The anteroposterior view was found to be diagnostic in minimal or marked avulsions of the medial epicondyle because of the characteristic inferior displacement. The anteroposterior view may not always be diagnostic in cases of entrapment of the medial epicondyle; the lateral view is usually diagnostic. In elbow dislocation, the presence and position of the medial epicondyle must be ascertained. Comparison and oblique views are often of value.
Two patients are described who had areas of rarefaction in the humeral heads that were biopsied and found to be normal bone. Almost all humeral heads have an area of localized rarefaction laterally, and when very pronounced this can be confused with a lytic lesion. These pseudocysts are so radiographically characteristic that they should not be biopsied.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Meat retailers have reported bone marrow discoloration to be a problem, especially in modified atmosphere packages (MAP). Therefore, it is important to determine the prevalence and cause(s) of bone marrow discoloration in different beef bones and packaging systems. Thirty-six beef humeri, ribs, scapulas, and thoracic vertebrae from USDA Select and Choice carcasses were obtained from a commercial abattoir, cut into 2.54-cm-thick sections at 4 d postmortem, and packaged into 1 of 3 systems: 1) polyvinyl chloride film (PVC) overwrap; 2) high-oxygen (80% O2, 20% CO2) MAP; and 3) ultra-low-oxygen (70% N2, 30% CO2) MAP. Instrumental reflectance and visual color scores were taken on d 0, 2, and 4, and on d 0 to 4 of display, respectively. Bone marrow was extracted from humeri, ribs, and thoracic vertebrae for analysis but not from scapulas. Ribs, scapulas, and thoracic vertebrae packaged in PVC and high-oxygen MAP developed undesirable gray or black discoloration. In ultra-low-oxygen MAP, mean visual color scores were acceptable throughout the entire display period. Discoloration (darkening) was more extensive for ribs, scapulas, and thoracic vertebrae than for humeri, especially for bones packaged in PVC and high-oxygen MAP. Humeri had lower (P < 0.05) a* values (larger positive a* values indicate a redder color) than the other bones. The a* values for ribs, scapulas, and thoracic vertebrae decreased (P < 0.05) over time. Chroma showed that bone marrow discolored during display, but graying was dramatically less for all bones packaged in ultra-low-oxygen MAP and for humeri in PVC and high-oxygen MAP. Humeri marrow had lower (P < 0.05) 2-thiobarbituric acid reactive substances (TBARS) than did ribs and thoracic vertebrae marrow. Ultra-low-oxygen MAP resulted in the least amount of change in TBARS from d 0 to 4, whereas thoracic vertebrae marrow had greater (P < 0.05) TBARS values at d 4 of display than at d 0 in PVC and high-oxygen MAP. Humeri marrow had dramatically less total Fe and hemoglobin than did that of ribs and thoracic vertebrae for all packaging systems. Myoglobin was undetectable in humeri marrow. The much larger amounts of Fe and hemoglobin in ribs and thoracic vertebrae likely contribute to marrow discoloration. Bone marrow discoloration was distinct in ribs, scapulas, and thoracic vertebrae packaged in PVC or high-oxygen MAP. Bones packaged in ultra-low-oxygen MAP had minimal discoloration.
Explore the source record for details and available documents.