Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CHROMATOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80Linked to original sources

[Analysis of plasminogen activator in human plasma using the method of fibrin/celite column chromatography--with special reference to the determination of fibrin adsorbable tissue-plasminogen activator by ELISA].

To clarify the clinical importance of tissue-plasminogen activator (t-PA) on the thrombosis, it is essential to be measured t-PA level in human plasma. Taking advantage of strong affinity of t-PA to fibrin, t-PA was isolated with Fibrin/Celite column chromatography. Immunological activities of t-PA of plasma samples determined by ELISA and the elution pattern of it on Fibrin/Celite column chromatography were studied. The results are as follows: The t-PA in human plasma was consisted of fibrin adsorbable t-PA and fibrin nonadsorbable t-PA. Both types of t-PA could be measured separately by using of Fibrin/Celite column chromatography. The fibrin adsorbable t-PA fraction showed two types of molecular size (major peak was Mr congruent to 70,000, minor peak was Mr congruent to 100,000) on Sephadex G-200 chromatography. The level of t-PA in plasma samples taken from 20 healthy subjects at rest was 2.4 +/- 1. 9 ng/ml, and concentration of t-PA increased to 10.4 +/- 3.2 ng/ml after venous stasis. But the t-PA level of plasma samples from patients with cerebral thrombosis did not increase after venous stasis. The changes of immunologically determined t-PA in plasma samples induced by venous stasis were not reflected in the fibrinolytic activities of the euglobulin fractions, but well reflected in the fibrinolytic activities of the elution fractions on Fibrin/Celite column chromatography. The level of fibrin nonadsorbable t-PA did not change by venous stasis, but the level of fibrin adsorbable t-PA increased from 5.1 +/- 1.9 ng/ml to 9.7 +/- 2.7 ng/ml in the case of 6 healthy subjects. It is concluded that, the plasma t-PA increased by venous stasis was the fibrin adsorbable t-PA, and it may play a very important role in physiological fibrinolysis.

Adsorption↗

Lipoprotein separation and low density lipoprotein molecular weight determination using high performance gel-filtration chromatography.

Plasma lipoproteins were isolated at d less than 1.225 g/ml from nonhuman primates of three species, cynomolgus, rhesus, and African green (vervet) monkeys. Individual lipoprotein classes were separated by high performance gelfiltration chromatography and low density lipoprotein (LDL) molecular weight was determined. A comparison was made using column configurations including TSK 3000 SW, 4000 SW, and 5000 PW columns. Due to its relative simplicity, stability, and economy, a single 5000 PW column was selected for most of the work. The recovery of lipoprotein cholesterol from the column averaged 91 +/- 2.5%. A comparison of the immunologic, chemical, and electrophoretic properties of high density lipoproteins (HDL) and LDL isolated by this technique with those of HDL and LDL isolated by conventional agarose column chromatography indicated that lipoproteins isolated by high performance gel-filtration chromatography were intact and reasonably free of cross contamination. A standard preparation of 125I-labeled LDL was added to the d less than 1.225 g/ml lipoprotein fraction just prior to separation and a relative size index, r1, was determined. When r1 values for a large number of samples were compared with the log of the LDL molecular weight (determined by agarose column chromatography) a linear relationship was found with a correlation coefficient, r = 0.85. The regression equation for this relationship could be used to calculate LDL molecular weights from the r1 value. These values agreed with LDL molecular weight determined by flotation equilibrium analysis in the analytical ultracentrifuge. We conclude that high performance gel-filtration chromatography using the TSK 5000 PW column provides an analytical and preparative technique for simultaneous separation of individual lipoproteins and determination of LDL molecular weight.

Animals↗

Affinity chromatography of Streptomyces erythreus trypsin-like enzyme on Japanese quail ovomucoid.

For simple, rapid purification of Streptomyces erythreus trypsin-like enzyme (TLE), we examined affinity chromatography with quail ovomucoid (QO) as a ligand of an affinity matrix. We prepared two affinity matrices by the cyanogen bromide method and the oxirane coupling method, and compared their binding efficiencies for TLE using frontal affinity chromatography. The affinity matrix in which QO was immobilized by the cyanogen bromide method showed 30% binding efficiency. However, another matrix, in which QO was immobilized by the oxirane coupling method with the lysine residue of the reactive site blocked by citraconylation, showed 92% binding efficiency. The results suggest that some biologically inactive QO was formed during the coupling reaction by the cyanogen bromide method. When we purified TLE from S. erythreus culture broth by affinity chromatography on QO-Sepharose, TLE was purified about 1,100-fold by affinity chromatography, and was further purified by DEAE-Sephadex A-25 column chromatography to homogeneity. The overall yield of TLE activity was higher than 90%. Thus, we were able to greatly improve previous purification procedures.

Animals↗

Reversed-phase high pressure liquid chromatography of globin chains: its application for the prenatal diagnosis of beta-thalassemia.

The separation of alpha, beta, G gamma and A gamma globin chains by reversed phase high pressure liquid chromatography has been studied using columns of octadecylsilyl-silica. All separations were performed in solvent mixtures of water and acetonitrile acidified with phosphoric acid or the hydrophobic ionpairing reagent trifluoroacetic acid. The addition of trifluoroacetic acid or the chaotropic agent NaClO4 to the mobile phase increased the resolution and the peak sharpness of the eluted globin chains. The use of decreasing gradients of TFA or NaClO4 and chromatography at 40 degree were useful steps for the separation of alpha and beta globin chains, a prerequisite for the successful application of this method for the prenatal diagnosis of beta-thalassemia. The beta/gamma synthetic ratio obtained from blood samples taken by fetoscopy from normal fetuses and fetuses with beta-thalassemia trait were measured simultaneously by CM-cellulose chromatography and high pressure liquid chromatography. The values obtained by HPLC were very similar but slightly lower than those obtained by CM-cellulose chromatography. The new method is fast and accurate and will prove to be useful for prenatal diagnosis involving globin chain separation.

Chromatography, High Pressure Liquid↗

Plasma elimination of indocyanine green in the intact pig after bolus injection and during constant infusion: comparison of spectrophotometry and high-pressure liquid chromatography for concentration analysis.

Indocyanine green is used to estimate liver blood flow rate and hepatic intrinsic clearance. However, its use as a test substance for studies of liver function has been limited by two puzzling kinetic observations: a biexponential plasma decay after bolus injection with an extremely slow late phase and an apparently steadily decreasing clearance value during constant infusion. These observations have been made with spectrophotometric concentration analysis. In anesthetized 30- to 40-kg pigs, we examined plasma concentration curves of indocyanine green after intravenous bolus injection and during long-term infusion. We compared spectrophotometry with high-pressure liquid chromatography for measurement of plasma indocyanine green concentration. In freshly prepared commercially available indocyanine green, high-pressure liquid chromatography could separately measure two fractions, the genuine indocyanine green (97% to 99% of total) and an in vitro degradation product (1% to 3%). Because their spectra were nearly identical, these fractions could not be distinguished by spectrophotometry. After intravenous administration both fractions were identified in the plasma by high-pressure liquid chromatography. In the first series (n = 6) 25 mg of indocyanine green was injected intravenously for 5 min. When analyzed by high-pressure liquid chromatography, the genuine indocyanine green plasma concentration decay was biexponential with rate constants 0.196 +/- 0.021 (mean +/- S.E.M., n = 6) and 0.0372 +/- 0.0064 min-1. The degradation product of indocyanine green decayed almost monoexponentially, with a rate constant of 0.0093 +/- 0.0002 min-1. With spectrophotometry a biexponential decay was observed with rate constants 0.130 +/- 0.012 and 0.0095 +/- 0.0001 min-1. The biexponential decay of indocyanine green after spectrophotometry was the result of codetermination of the two fractions: genuine indocyanine green was responsible for initial phase, and the degradation product of indocyanine green was responsible for the late phase. In the second series (n = 9), indocyanine green was administered as a constant intravenous infusion. From 90 to 240 min the intrinsic hepatic clearance of genuine indocyanine green did not change detectably with time. In contrast, the degradation product of indocyanine green never reached steady-state concentrations. Because of code-termination of these two indocyanine green fractions, the apparent intrinsic hepatic clearance of indocyanine green estimated from spectrophotometry was steadily decreasing by 8.9% +/- 1% per hour of its initial value. At the same time estimation of liver plasma flow rate based on Fick's principle was not affected by the choice of analytical methodology. These observations indicate that high-pressure liquid chromatography is superior to spectrophotometry for kinetic analysis of indocyanine green elimination.

Animals↗

Polymer-shielded dye-ligand chromatography of lactate dehydrogenase from porcine muscle in an expanded bed system.

Dye-affinity chromatography is a widely used technique in protein purification. It has recently been shown that the efficiency of the chromatography process can be significantly improved by pretreatment of the affinity matrix with certain water soluble polymers such as poly(vinyl pyrrolidone). This technique termed as polymer-shielded, dye-affinity chromatography has been successfully used in packed bed mode at a lab scale for the purification of a number of enzymes. The present work deals with the application of polymer-shielded dye-affinity chromatography in an expanded bed system of Streamline-Cibacron Blue 3GA for the isolation of lactate dehydrogenase from a crude porcine muscle extract. The elution conditions were optimised to obtain an efficient process. A higher recovery of the target enzyme (78%) was obtained from the polymer shielded column as compared to the unshielded column (17%), after low ionic strength elution. The purification factor obtained after chromatography on the polymer shielded column was higher (4.1) than that from unshielded column (1.8).

Animals↗

Location by paper chromatography of compensatory ovarian hypertrophy (COH) inhibiting activity in isobutanol extracts of bovine pineals.

Bovine pineal glands were extracted according to the methods reported by Bensinger et al. (1973) and Cheesman and Fariss (1970). Isobutanol soluble COH-inhibiting activity was further separated by chromatography on Sephadex G-15 and paper chromatography. With the Bensinger method, different active pineal fractions were obtained from Sephadex G-15 columns. Certain of those fractions were further separated by paper chromatography in butanol : acetic acid : water (4 : 1 : 1) and the COH-inhibitor was localized. The pineal COH-inhibitor could also be localized by high pressure, reverse phase liquid chromatography. More COH-inhibiting activity was extracted with the Bensinger method than with aqueous and acetic acid extraction methods used earlier by us. The Cheesman extraction method for arginine vasotocin gave less regular results in our hands than the Bensinger extraction method.

Animals↗

Quantitation of histamine and some of its basic methylated metabolites in biological materials by gas-liquid chromatography.

A method which measures histamine, its basic metabolites, and some analogs in biological materials is described. The procedure consists of ion-exchange chromatography and chromatography on silicic acid for isolation and purification, and gas chromatography for identification and quantitation. The isolated compounds are prepared for gas chromatography by double derivatization with heptafluorobutyric anhydride and acetic anhydride. One of the synthetic histamine analogs, 2-methylhistamine, is used as an internal standard. The metabolites can be quantitated at a level as low as 1.5 nmol/100 microliters final concentration. The method is adaptable to a variety of applications, with good reproducibility and sensitivity. A number of different biological samples have been analyzed.

Acetylation↗

Superoxide chemical transformation of diolepoxide polyaromatic hydrocarbon DNA adducts. Determination of benzo[a]pyrene-r-7,t-8,9,c-10-tetrahydrotetrol by gas chromatography.

Benzo[a]pyrene-r-7,t-8,9,c-10-tetrahydrotetrol (100 pg, 342 fmol) was measured using the following sequence of steps: (1) chemical transformation with potassium superoxide to 2,3-pyrenedicarboxylic acid; (2) electrophore derivatization with pentafluorobenzyl bromide; (3) sample clean-up by high-performance liquid chromatography and (4) measurement by gas chromatography with electron-capture detection and by gas chromatography with electron-capture negative-ion mass spectrometry. The overall, absolute yields obtained by the two procedures were 69% and 60%, respectively. This work completes the first stage towards the establishment of a general method for detecting diolepoxide polyaromatic hydrocarbon DNA adducts by gas chromatography.

Benzo(a)pyrene↗

Purification of the coenzyme B12-containing 2-methyleneglutarate mutase from Clostridium barkeri by high-performance liquid chromatography.

Two methods are described by which the enzymes 2-methyleneglutarate mutase and 3-methylitaconate delta-isomerase from Clostridium barkeri have been separated by high-performance liquid chromatography on a much larger scale than reported previously. First, the mutase eluted before the delta-isomerase after incubation with the mild detergent 3-[(3-cholamidopropyl)dimethylammonio]-1-propanesulphonate (CHAPS) followed by high-performance anion-exchange chromatography on Mono Q in the presence of the same detergent. Second, an even better separation, although with a lower yield of mutase, was obtained by hydrophobic interaction chromatography on phenyl-Sepharose HiLoad, whereby the enzymes were eluted in the reverse order. Final high-performance anion-exchange chromatography of the latter preparation on Mono Q at pH 8 gave highly purified 2-methyleneglutarate mutase (greater than 95% purity) which had a pink-orange colour (lambda max 280, 375, 470 and 532 nm). The enzyme was active in the absence of coenzyme B12 (adenosylcobalamin) and contained 2.1 mol of this coenzyme per homotetramer (molecular mass, m = 300 kilodalton).

Amino Acid Sequence↗

Comparison of separation modes of high-performance liquid chromatography for the analysis of glycoprotein- and proteoglycan-derived oligosaccharides.

Porous graphitised carbon (PGC) has been explored for high-performance liquid chromatography (HPLC) of mono- and di-saccharides released from proteoglycans and of fluorescently labelled oligosaccharide derivatives for high-sensitivity detection. Sulphated oligosaccharides show good retention and separation behaviour on PGC-HPLC, and compared to anion-exchange or reversed-phase ion-pair chromatography the chromatography is carried out in the absence of salt. Due to their poor retention on PGC-HPLC the analysis of single uronic acids has been optimised with high pH anion-exchange chromatography. Fluorescent labelled derivatives formed by reductive amination of neutral oligosaccharides with 2-aminobenzamide have been chromatographed on PGC-HPLC and by BioGel P4 gel filtration.

Carbohydrate Conformation↗

Rapid and efficient purification of mouse monoclonal antibodies from ascites fluid using high performance liquid chromatography.

Techniques for the rapid and efficient purification of mouse monoclonal antibodies from murine ascites are described that utilize anion exchange and gel permeation chromatography using high performance liquid chromatography (HPLC). Anion exchange chromatography was performed at neutral pH using a hydrophilic resin conjugated with a substituted amine (Mono Q column, Pharmacia Fine Chemicals). Various subclasses of mouse IgG monoclonals were assessed for their binding to this matrix, with all of the antibodies tested eluting at relatively low concentrations of sodium chloride. In some instances, a protein tentatively identified as transferrin was co-purified using this anion exchange procedure. However, this protein was easily removed from the IgG using gel permeation chromatography (Bio-Sil TSK-250, Bio-Rad), also performed at neutral pH.

Animals↗

N-acetylmuramyl-L-alanyl-D-isoglutamine stimulates the immune response of B cells. Use of fast protein liquid chromatography to purify a novel monokine involved in this effect.

The immune response of murine B cells, which requires the presence of various cytokines, was stimulated by N-acetylmuramyl-L-alanyl-D-isoglutamine. A novel monokine involved in this effect has been partially purified from the conditioned medium of peritoneal macrophages by using affinity chromatography on Blue-Sepharose and high-performance liquid chromatography. Hydrophobic interaction chromatography was highly efficient in removing almost all protein contaminants. The resulting biologically active material exhibited heterogeneity in ion-exchange chromatography, and apparent isoelectric points between 5.2 and 5.5 on chromatofocusing. Its apparent molecular weight, as determined by size-exclusion filtration, was about 35,000. Preliminary results on the kinetics of appearance of intracellular biological activity suggested that the monokine could also be obtained from cytoplasmic extracts.

Acetylmuramyl-Alanyl-Isoglutamine↗

Fast protein liquid chromatography of lymphocyte blastogenesis inhibitory factor produced by the human macrophage-like cell line U937.

The human macrophage-like cell line U937 constitutively produces a lymphocyte blastogenesis inhibitory factor (LBIF). Using fast protein liquid chromatography (FPLC)-chromatofocusing, FPLC-anion-exchange chromatography and high-performance liquid chromatography-gel permeation chromatography, LBIF has been purified to homogeneity. It is a single polypeptide chain and has a molecular weight of 57,000 daltons according to sodium dodecyl sulphate polyacrylamide gel electrophoresis under reducing conditions. LBIF shows pI 4.28-4.56 upon chromatofocusing on Mono P.

Animals↗

Elucidation of the composition of bovine milk fat triacylglycerols using high-performance liquid chromatography-atmospheric pressure chemical ionisation mass spectrometry.

Bovine milk fat triacylglycerols (TAGs) have been characterised using high-performance liquid chromatography-atmospheric pressure chemical ionisation mass spectrometry (HPLC-APCI-MS) and high-temperature gas chromatography-mass spectrometry (GC-MS). The complex nature of the fat meant that prefractionation was necessary to provide simpler fractions for more detailed molecular analyses. Silica thin-layer chromatography gave rise to two fractions, one of which contained predominantly butyric acid containing TAGs. Gel permeation chromatography (GPC) gave rise to 16 fractions, which were subsequently analysed using HPLC-APCI-MS. Twelve of the GPC fractions were also analysed by high-temperature GC-MS using a capillary column coated with a polarisable stationary phase. TAGs present in the fractions were correlated with those in the chromatogram of the whole milk fat through retention time comparison and the use of mass chromatograms. In total, 120 TAGs were identified.

Animals↗

Purification of lipoteichoic acid by chromatography in water-organic solvent systems.

Lipoteichoic acid (LTA), extracted from Streptococcus mutans 10449 by hot aqueous phenol, was partially purified by Sepharose 6B column chromatography in 0.01 M sodium acetate, pH 6.0, containing 0.25 M sodium chloride and 0.001 M EDTA. Nucleic acid and polysaccharide were precipitated from the LTA-containing column peak by the addition of 2 volumes of chloroform-methanol (1:5). The resulting single-phase chloroform-methanol-water (1:5:3) supernatant contained LTA and small amounts of several contaminating substances as indicated by reverse-phase high-pressure liquid chromatography and chemical analyses. LTA was purified further by DEAE-cellulose chromatography, using a concentration gradient of sodium chloride in chloroform-methanol-water (1:5:3). Two column peaks of LTA were found to contain phosphate, glycerol, glucose, and fatty acids at molar ratios of 1:1:0.11:0.10 and 1:1:0.09:0.04, respectively. The LTA polymers contained 18 and 22 repeating units of unsubstituted glycerophosphate and two glucose residues. The LTA in one column peak had two fatty acids per molecule, whereas that in the second peak contained only one. The yield of LTA was 1.68 mg per g of cell dry weight or 65 mg per g of phenol-water-extracted material. The specific activity of the LTA preparation was increased 128-fold by the purification scheme as determined by a erythrocyte-binding assay. Reverse-phase high-pressure liquid chromatography may be used for rapid separation of LTA molecules containing different numbers of acyl groups.

Chromatography, Agarose↗

Chromatography and computational chemical analysis for drug discovery.

Analytical chemists have increasingly turned their attention to drug discovery and drug analysis and to solve fundamental questions of biological significance in physiology and genetics. New technologies have been developed, and a variety of instruments have been redesigned for biomedical applications. The development of high-performance liquid chromatography (HPLC) opened a new era in biorelated fields and allowed faster separations of fragile macromolecules. Capillary column gas chromatography (GC)/mass spectrometry (MS) have been used to achieve more powerful separation and to perform structural analysis of molecules, and laboratory automation including robotics has become a powerful trend in both analysis and synthesis. Liquid chromatography (LC)/MS is more suitable for biomedical applications than GC/MS because almost all biomolecules are heat sensitive. Furthermore, a combination of various mass spectrometers has been used even for proteins directly. Improving the sensitivity of nuclear magnetic resonance spectrometry (NMR) has permitted a direct connection with LC. Purification of biomolecules on-line by LC has been performed since the development of chip-electrophoresis, On the other hand, computational chemical analysis is a promising technique given the advancing the hardware and software for use in chemical fields. In this review, a combination of chromatography and computational chemistry for use in drug discovery studies is described. Fast LC analysis using a column switching technique was introduced for aromatic amino acid metabolites and guanidino compounds. Recent developments in related technologies are also included from review papers.

Amino Acids, Aromatic↗

[Development and applications of high performance membrane chromatography].

Development and applications of high performance membrane chromatography (HPMC) are introduced. Base membranes, membrane geometries and separations of biomolecules using high performance affinity membrane chromatography (HPAMC), high performance ion-exchange membrane chromatography (HPIEMC) and high performance hydrophobic interaction membrane chromatography (HPHIMC) are reviewed. Enantiomeric separation using HPMC are prospected. Seventy-six references are cited.

Chromatography, Affinity↗