Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “data reproducibility”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8Linked to original sources

Feasibility of the use of a novel soft tissue stiffness meter.

Simple but objective measurement of soft tissue consistency would be advantageous in the assessment of many neurological, lymphostatic and venous disorders. The aim of the present study was to evaluate the feasibility of using a novel hand-held computerized soft tissue stiffness meter (STSM). The STSM describes the soft tissue stiffness (STS) in the form of the instantaneous force (N) by which the tissue resists the constant deformation produced by a cylindrical intender. Firstly, the STSM was used to test elastomer samples with known mechanical properties. In the in vivo assessment, 12 healthy, nondisabled adults (age range, 24-57 years) and 16 subjects with chronic myofascial neck pain syndrome (age range, 27-55 years) were studied. To study the reproducibility (coefficient of variation (CV(%))) of the method, the measurement sites were either marked with a marker pen (marked points) or localized anatomically (unmarked points). Measurements were made from the dorsal forearm (Arm), trapezius (Tra), levator scapulae (Lev), infraspinatus (Inf) and deltoideus (Del) muscle areas. STS in the forearm was studied during different types of short-term relative isometric loading of the muscle as well as during venous occlusion. STS values of the myofascial trigger points in the Lev muscles were evaluated bilaterally. A linear, positive relationship was found between the indenter force (N) and the dynamic compressive modulus (MPa) of elastomer stiffness (r(2) = 0.90, n = 9). Intra- and interrater CVs of marked and unmarked sites varied between 4.31% and 12.06%. STS increased linearly along the relative muscle load (r(2) = 0.96) and nonlinearly during the venous occlusion (r(2) = 0.97). Statistically significant regional variation of STS was found between the different measurement sites (p < 0.05). In conclusion, STSM can evaluate tissue stiffness quantitatively and yield reproducible data.

Adult↗

Comparison of the oxidizability of various glycerophospholipids in bilayers by the oxygen uptake method.

The aims of this study were twofold: develop a convenient and rapid procedure for assessing the oxidizability of small quantities of glycerophospholipids in bilayers by the oxygen uptake method, and determine and compare the oxidizability of various glycerophospholipids in bilayers. Our purpose was to elucidate phospholipid oxidation characteristics in membranes. The quantitative autoxidation kinetics of dilinoleoyl phosphatidylcholine (DLPC) (18:2/18:2) was studied in large unilamellar vesicles (LUV) in aqueous dispersions with water-soluble initiator--2,2'-azobis(2-amidinopropane) dihydrochloride--and inhibitor 2-carboxy-2,5,7,8-tetramethyl-6-chromanol. The kinetic data indicated a high efficiency of free radical production, resulting in shortening of measuring time; the very low kinetic chain length, particularly in the induction period, suggested the possibility of including large errors in the kinetics data. Nevertheless, the autoxidation of DLPC obeyed the classic rate law: Rp = kp[LH]Ri(1/2)/(2kt)(1/2) (where Rp = rate of oxygen consumption, kp = rate constant for chain propagation, [LH] = substrate concentration; Ri(1/2) = square root of rate of chain initiation, and 2kt = rate constant for chain termination) in a mixed bilayer system with saturated dimyristoyl PC (14:0/14:0), which provided precise and reproducible data. Therefore, the system was used to assess the relative oxidizability of each glycerophospholipid DLPC (18:2/18:2), dilinolenoyl PC (18:3/18:3),1-palmitoyl-2-linoleoyl PC (16:0/18:2), 1-palmitoyl-2-arachidonoyl PC (16:0/20:4), 1-palmitoyl-2-docosahexaenoyl PC (16:0/22:6), and dilinoleoyl PE (18:2/18:2) in bilayers. The results suggested that the oxidizability of glycerophospholipid in bilayers is substantially influenced by the number of intramolecular oxidizable acyl chains and the content of bis-allylic hydrogen in a structured environment, and showed deviation of the rate law for autoxidation in PC and PE mixed LUV, which possibly was due to non-homogeneous phospholipid distribution in vesicles.

Chromatography, Thin Layer↗

[Facial anthropometry and aesthetic perception in young italian subjects: their use for orthognatic surgery].

BACKGROUND: Aesthetic requests of patients undergoing orthognatic surgery have increased over time and represent nowadays the leading subjective motivation for the patient and a major aim of the treatment for the surgeon. In this regard, anthropometric evaluation has considerably improved the diagnostic capacity of the orthodontist and of the surgeon. Aim of the study is to provide the orthognatic surgeon with anthropometric normal values based on a sample of aesthetically pleasant Italian subjects and to discuss the use of a simplified aesthetical analysis in the set-up of the surgical plan and in the evaluation of treatment outcome. METHODS: The present study analyses 94 Italian subjects, by means of anthropometric measurements on photographic images, considering 28 facial proportions and 33 angular values. These figures were compared with the aesthetic judgement provided by 3 common observers and 3 orthodontists. The aesthetic score was attributed on a subjective discrete scale (common observer: above average/average/below average; orthodontist: eumorphic/ dismorphic). Data were also compared with similar evaluations on North-American and African subjects reported in the international literature. RESULTS: This study confirms the sexual dismorphism and the ethnic variability already reported by other Authors and documents specific morphological characters in the Italian population. CONCLUSIONS: The described method appears acceptably simple and consistent for clinical application. Its use in orthognatic surgery may provide objective and reproducible data for evaluating the aesthetic outcome of treatment.

Adolescent↗

Validation of a new intraoperative technique to evaluate load-independent indices of right ventricular performance in patients undergoing cardiac operations.

BACKGROUND: Assessment of right ventricular performance in the perioperative period is difficult because there is no generally accepted method of measuring right ventricular volume. We set out to determine whether conductance technology could provide a valuable technique for the investigation of intraoperative right ventricular function. METHODS AND RESULTS: Three validating studies were performed in 25 patients undergoing routine coronary revascularization. Study 1: The influence of conductance catheter position in the right ventricle was examined in 10 patients. Insertion of the conductance catheter through the outflow tract was associated with a larger gain constant and a smaller parallel conductance compared with insertion through the tricuspid valve. Study 2: The reproducibility of contractility measurements with the use of a conductance catheter was examined in 7 additional patients. Removal and reinsertion of the conductance catheter was not associated with any significant difference in right ventricular volume or contractile function. Study 3: Right ventricular performance before and after cardiopulmonary bypass was compared in 8 additional patients. There was a fall in the slope of the right ventricular preload recruitable stroke work from 15.6 (3.8) to 11.0 (5.1) mm Hg (P=.01) and an increase in the slope of the end-diastolic pressure-volume relations from 0.05 (0.02) to 0.11 (0.05) mm Hg/mL (P=.001). CONCLUSIONS: The conductance technique can be used to study perioperative changes in right ventricular performance. Insertion of the conductance catheter through the outflow tract provides stable and reproducible data. There is significant impairment of right ventricular contractility in the early postoperative period.

Cardiac Catheterization↗

Isolation of highly infectious and pure adeno-associated virus type 2 vectors with a single-step gravity-flow column.

One of the most promising gene transfer vectors in human clinical trials is AAV2. The quality of the vector preparations is a key element in obtaining reliable and reproducible data in preclinical studies. However, established protocols either result in impure, low infectious virus (CsCl2 gradient centrifugation) or demand a high level of manual and technical skills (CsCl2 gradient centrifugation, iodixanol/heparin or HPLC purification). In this study, we present an easy-to-do single-step column purification (SSCP) of AAV2 by gravity flow based on its affinity to heparin, without ultracentrifugation. Various vector preparations generated by our method reproducibly showed high titers, infectivity, and purity. In vivo, our single-step column-purified AAV2 vectors mediate significantly higher transduction efficiency compared with conventional protocols. Investigators still unsatisfied with previously published techniques or new to the field of AAV production may find in our method an interesting alternative.

Animals↗

Inter- and intra-study reproducibility of contrast echocardiography for assessment of interventricular septal wall perfusion rate in humans.

AIMS: To assess inter- and intra-study reproducibility of myocardial contrast echocardiography (MCE) imaging for quantitative measurement of myocardial perfusion rate in humans in ambulatory setting. METHODS AND RESULTS: In 20 subjects, we performed 2 MCE tests 20-40 min apart on the same day under the same standardized protocol, and evaluated single-reader between-study and between-reading reproducibility of assessment of indicators of myocardial perfusion rate, such as the slope of video-intensity change k, and the factors A (peak video-intensity) and B (background video-intensity after bubble destruction) and the product k X A. The region of interest was placed at the mid-posterior interventricular septal wall visualized in apical 4-chamber view. In a sub-analysis, we evaluated indicators of myocardial perfusion rate comparing subjects with normal vs. those with subnormal ejection fraction (EF). Inter-study reproducibility of assessment of k was relatively low (intraclass correlation coefficient = 0.36), whereas intra-study reproducibility was fair (intraclass correlation coefficient = 0.61). The parameters k X A and B showed higher reproducibility than the k (inter- and intra-study intraclass correlation coefficients 0.64 and 0.75, 0.74 and 0.91, respectively). For reference, reproducibility data of the depth of the region of interest, of EF and CO were excellent. k and k X A were lower in subjects with low vs. those with normal EF. Only k and k X A were lower in subjects with subnormal than in those with normal EF. CONCLUSIONS: The MCE-derived indicator of myocardial perfusion rate k X A showed fairly good between-study and between-reading reproducibility.

Aged↗

Pulmonary parenchymal tissue volume and pulmonary capillary blood flow in normal subjects.

We measured pulmonary parenchymal tissue volume (Vt) and pulmonary capillary blood flow (Qc) in 11 normal subjects by a rebreathing technique and end-tidal, dead-space correction (ETDS) method, using two soluble gases, acetylene (C2H2) and dimethyl ether (DME). We assessed the results using different intervals of measurement, inspired volumes and rebreathing frequencies. The mean values +/- SD of Vt were 559 +/- 58 and 511 +/- 52 ml, with C2H2 and DME, and of Qc were 3.67 +/- 0.44 and 4.18 +/- 0.54 liter/min/m2, respectively. Measurements with the interval between the 1st and the 6th end-tidal points and within the first 15 s yielded the best reproducibility. Data obtained from two satisfactory recordings from the same subject are sufficient to calculate Vt and Qc. Inspired volume shows a significant correlation with Vt values measured with both tracer gases, especially with DME. Rebreathing frequency also affects this latter gas. Despite some problems which are not easily explainable (dependence upon the inspired volume, rebreathing frequency and test gas species), we conclude that the methods allow measurements of Vt and Qc with acceptable reproducibility but that different variables may affect the results.

Adult↗

The role of nitric oxide synthase inhibition in the adverse effects of etomidate in the setting of focal cerebral ischemia in rats.

We evaluated the effect of N(G)-nitro-L-arginine-methyl-ester (l-NAME, a nitric oxide synthase [NOS] inhibitor) and L-arginine (nitric oxide substrate) on cerebral mitochondrial dysfunction (hereafter referred to as "injury") after temporary middle cerebral artery occlusion (MCAo) during halothane or etomidate anesthesia in spontaneously hypertensive rats. Sixty minutes before MCAo, rats were randomized to 1 of 5 regimens (n = 8 per group): h/control, 1.2 minimum alveolar anesthetic concentration of halothane; h/L-NAME, 1.2 minimum alveolar anesthetic concentration of halothane and L-NAME (30 mg/kg); etomidate, an electroencephalographic (EEG) burst suppression dose of etomidate; e/L-NAME, an EEG burst suppression dose of etomidate and L-NAME (30 mg/kg); or e/L-NAME/arg, an EEG burst suppression dose of etomidate, L-NAME (30 mg/kg), and L-arginine (bolus of 300 mg/kg with an infusion at 35 mg x kg(-1) x min(-1)). After 180 min of MCAo and 120 min of reperfusion, volume of injury was determined using 2,3,5-triphenytetrazolium stain. Injury volume (mm(3), mean +/- sd) was larger in the etomidate group (153 +/- 17) than the halothane anesthetized h/control group (93 +/- 16) (P < 0.05) but did not differ between the e/L-NAME (162 +/- 17) and h/L-NAME groups (155 +/- 26). Injury volume in the e/L-NAME/arg group (88 +/- 15) was not different from the h/control group (93 +/- 16) and was less than that in either the etomidate or the e/L-NAME groups (P < 0.05). The data reproduce our previous observation that, relative to a halothane-anesthetized control state, etomidate has an adverse effect on ischemic injury in the setting of temporary focal cerebral ischemia. Prior inhibition of NOS with L-NAME resulted in no difference in the volume of injury between groups receiving etomidate or halothane (162 +/- 17 versus 155 +/- 26). Administration of a large dose of L-arginine prevented the adverse effect of etomidate. The data were obtained after only 2 h of reperfusion and therefore cannot be construed as representative of final neurologic outcome. They nonetheless suggest that etomidate produces an adverse effect on mitochondrial function early in the course of focal cerebral ischemia, in part, by inhibition of NOS.

Animals↗

Comparison of two different software systems for electron-beam CT-derived quantification of coronary calcification.

OBJECTIVE: The growing interest in coronary calcium quantification by electron-beam CT (EBCT) has led to the development of various software systems for the analysis of EBCT raw data, but it is unknown whether these software systems yield comparable results. METHODS: Two sets of EBCT scans were obtained in 73 asymptomatic patients less than 15 minutes apart. Both scans of each patient were analyzed using two different software systems, the Mayo Clinic software and the AccuImage Scoring System. The authors compared the calcium quantities yielded by the two different software systems, analyzed the interscan variability, and calculated the interobserver variability. Finally, they investigated the influence of the CT density factor inherent in the widely used Agatston score for the quantification of coronary calcium on reproducibility. RESULTS: The mean score determined by the Mayo Clinic software was 14% greater than that determined by the AccuImage system. The mean difference between the two systems was 14% +/- 25%, and the median difference was 3%. The relative mean and the median difference between the two scans of one patient were 15.3% and 6% determined by the AccuImage system and 17% and 6.5% determined by the Mayo Clinic software. The interobserver reliability calculated by the Mayo Clinic software was better than that of the AccuImage system. There was a trend for better reproducibility using calcium area rather than the Agatson score. CONCLUSIONS: Two different scoring systems do not necessarily yield the same result. Calcium quantities were systematically determined to be greater by one system than the other, and there were significant differences with regard to interobserver reliability. Hence, software should be tested with regard to reproducibility data, and the interpretation of calcium quantities should acknowledge which type of software was used.

Adult↗

Methods and devices for measuring arterial compliance in humans.

This review analyses methods and devices used worldwide to evaluate the arterial stiffness. Three main methodologies are based upon analysis of pulse transit time, of wave contour of the arterial pulse, and of direct measurement of arterial geometry and pressure, corresponding to regional, systemic and local determination of stiffness. They are used in clinical laboratory and/or in clinical departments. Particular attention is given to the reproducibility data in literature for each device. This article summarizes the discussion of the dedicated Task Force during the first Conference of Consensus on Arterial Stiffness held in June 2000 (Paris, France).

Arteries↗

Gated first pass radionuclide ventriculography. Methods, validation, and applications.

Electrocardiographic gating provides an alternative method of acquiring first pass radionuclide ventriculograms from both ventricles. This report details the methods of acquisition and analysis, provides validation and reproducibility data, and describes applications of gated first pass radionuclide ventriculography using a count-based method. Left ventricular ejection fractions measured by gated first pass were correlated quite closely with gated blood pool ventriculography (n = 43; r = 0.95) but less well with contrast angiography (n = 23; r = 0.72). The right ventricular ejection fractions measured by gated first pass compared favorably with gated blood pool ventriculography (n = 32; r = 0.93). When one observer processed the images two times, the reproducibilities of RVEF (n = 10; r = 0.99) and LVEF (n = 10; r = 0.88) were excellent. Similarly, when two observers processed the images independently, the reproducibilities of RVEF (n = 11; r = 0.99) and LVEF (n = 11; r = 0.98) were excellent. The first pass studies were obtained in a right anterior obliquity, which provided the best atrioventricular chamber separation and provided a different view of global ventricular function and segmental wall motion from that provided by the standard blood pool views.

Adolescent↗

In vitro testing of six inferior vena cava filters: filtering efficiency and pressure measurements.

UNLABELLED: The purpose of this study is to compare in standarddised ex vivo conditions the performances of six percutaneous vena cava filters available on the European Market. METHODS: We use a mock circulation with polyethylene beads simulating clots to objectively determine the filtering efficiency of the different devices. We measured pressure at contact points with the wall of the tube simulating vena cava, and also gradient of pressure induced by the empty and full filter. Statistical analysis of the data obtained (at least 100 measurements for each filter) showed great consistency in the response of a given filter to the different conditions of mock circulation. RESULTS: The Greenfield Filter, which served as the reference, was compared to the other models. Its filtering efficiency was acceptable as was that of the L.G. Filter. The Cardial Filter and Vascor Filter were the most efficient. The Antheor Filter and the Filcard Filter performed poorly. CONCLUSION: The mock circulation give reliable and reproducible data on the filtering efficiency for a device but ease of placement and clinical studies must be taken into account for the choice of the filter.

Blood Pressure↗

Comparison of the rates of exchange of lead in the blood of newly born infants and their mothers with lead from their current environment.

Newly born infants (n = 15) were monitored for 6 months after birth or for longer periods to evaluate the changes in isotopic composition and lead concentration in infants as compared with that in women from the same population groups and to determine the clearance rates of lead from blood in the infants. These data represent the first published results for serial blood sampling in a relatively large cohort of newly born infants. Blood lead concentrations decrease from the cord to samples taken at 60 to 90 days and then increase by amounts varying from negligible to 166%. In spite of concern about individual susceptibility to lead pharmacokinetics, changes in isotopic ratio followed a smooth decrease over time for 9 of the 11 infants born to migrant parents, and the patterns of variation were quite reproducible. Data for 2 of 4 infants born to multigenerational Australian parents exhibited little change in isotopic ratio over time, and in the other two cases, the changes were attributed to diet. The rate of exchange (t1/2) for the migrant infants of lead in blood derived from the mother during pregnancy and the lead from the current environment was calculated by using a linear function and ranged from 65 to 131 (91+/-19, mean+/-SD) days. The half-lives for the exchange of skeletal and environmental lead for 7 of the 8 women before significant mobilization of lead from the maternal skeleton ranged from 50 to 66 (59+/-6) days. One explanation for the longer half-lives for infants as compared with the mothers may be the proportionally higher contribution of current environmental (Australian) lead in the infants at parturition. Exchanges of lead in infants are more complex than for the adults, reflecting inputs from sources such as maternal skeletal lead during breast feeding.

Adolescent↗

A study to validate the method based on DIMOND quality criteria for cardiac angiographic images.

A method based on image quality criteria (QC) for cine-angiography was developed to measure the quality of cine-angiograms (CA). A series of 30 CA for left ventriculography (LV) and left and right coronary angiography (LCA, RCA) have been scored and 172 readings were obtained. Standard deviation of quality scores indicated the reproducibility of the method. Each part of CA was examined separately, giving scores for LV, LCA and RCA and a total score (TS), with clinical (C) and technical (T) criteria defined and examined separately. In 83% of the studies TS was >0.8 and with standard deviation from 0.02 to 0.21. In general, LV had a lower score and greater disagreement compared with RCA and LCA. Disagreement was greater in T, compared with C. In conclusion, these results indicate that QC, translated into a scoring system, yields reproducible data on the quality of cardiac images.

Cineangiography↗

Ground-level solar spectral irradiance in Glasgow: an inter-comparison of two sites.

BACKGROUND: Solar spectral radiometry presents significant challenges to produce accurate and reproducible data. To investigate the reliability of the measurements, several inter-comparisons have been set up. Although these are useful, their main drawback is that equipment must be dismantled and transported to a common site and re-calibrated. METHODS: In this study, an inter-comparison has been performed of two spectroradiometers that are located 3 miles apart some 30 m above sea level. These two systems have operated using different calibration techniques. Data were compared on clear days, to minimise actual differences in ultraviolet irradiation. RESULTS: There were substantial differences at some individual wavelength points, but overall the mean difference of results at 5 nm intervals on an individual scan from the two systems agreed to within 11%. If the data were used to compute the erythemal irradiance, the differences were reduced to 4%. CONCLUSION: This study demonstrates both the limitations and the level of reliability that might be expected from these systems operating under careful scientific supervision.

Geography↗

Monitoring of dual-energy X-ray absorptiometry measurement in clinical practice.

Bone densitometry has become the "gold standard" in osteoporosis diagnosis and treatment evaluation. It has also become more and more common to perform a second dual-energy X-ray absorptiometry (DXA) measurement to monitor bone mineral density (BMD) status or the effect of therapeutic intervention. When a second measurement is performed on a patient, the clinician needs to distinguish between a true change in BMD and a random fluctuation related to variability in the measurement procedure. The reproducibility of DXA measurements is claimed to be good. Such variability is due to multiple causes, such as device errors, technician variability, patients' movements, and variation due to other unpredictable sources. The precision error is usually expressed as the coefficient of variation (CV). However, several other statistics to express reproducibility exist such as the smallest detectable difference (SDD) or the least significant change (LSC). The SDD represents a cut-off that can be measured in an individual and is usually considered more useful than the CV in clinical practice. Indeed, the use of the SDD is preferable to the use of the CV and LSC because of its independence from BMD level and its expression in absolute units (g/cm2). At each measurement center, the SDD must be calculated from in vivo reproducibility data. The choice of the optimum time and site for performing follow-up scans depends on the ratio of the expected BMD treatment effect to the precision of the measurements.

Absorptiometry, Photon↗

An alternative flow cytometry strategy for peripheral blood dendritic cell enumeration in the setting of repetitive GM-CSF dosing.

BACKGROUND: Enumeration of circulating peripheral blood dendritic cells (DCs) is complicated by the absence of a unique cell surface marker expressed on all DC subsets and by the use of various biological adjuvants to modulate the DC compartment, including granulocyte macrophage colony stimulating factor (GM-CSF). Common methods employ a cocktail of antibodies, typically including anti-CD14, to define a lineage negative, MHC class II positive, putative DC population. Reported flow cytometry protocols include highly variable gating strategies and DC identification criteria. Increasing appreciation of DC pleiomorphism, GM-CSF biology, and recognition of CD14 expression in some DC subsets led us to consider an alternative lineage cocktail to improve identification of the circulating DC pool. METHODS: Standard whole blood staining with appropriate fluorochrome conjugated antibodies to MHC class II and either standard CD14 containing, or an alternate CD66acde containing, lineage cocktail was performed on samples obtained from normal donors and breast cancer patients before and after administration of dose-dense, cytotoxic chemotherapy with daily GM-CSF hematopoetic growth factor support. Putative DCs were enumerated by standard flow cytometry. Data set differences were evaluated using two tailed Mann-Whitney or Wilcoxon signed rank tests. Cellular morphology was examined in cell-sorted populations from post GM-CSF samples. RESULTS: Use of either antibody cocktail defined comparably sized lineage negative, MHC class II positive populations in normal donors and at baseline in cancer patients. However, selection of lineage negative subsets with increasing MHC class II expression levels yielded larger putative DC populations identified with the alternate cocktail. Both cocktails yielded highly reproducible data. Use of the alternate cocktail: 1) yielded a putative DC population, post GM-CSF that was more homogenous and consistent with DCs, 2) resulted in less data variation across gating strategies, and 3) resulted in more uniform and concordant longitudinal data, consistent with established GM-CSF biological activity. CONCLUSION: An alternative lineage negative cocktail substituting anti-CD66 antibody for anti-CD14 is a viable option for enumerating the circulating DC population, potentially more accurately defining the circulating DC pool by including CD14 positive immature DCs, and thus, may give more reliable data, particularly in the setting of sustained GM-CSF administration.

Journal Article↗

Two- and three-dimensional assessments of myocardial perfusion and function by using technetium-99m sestamibi gated SPECT with a combination of count- and image-based techniques.

BACKGROUND: Although the myocardial gated single photon emission computed tomography (SPECT) technique makes it possible to assess concurrent myocardial perfusion and function, quantitative methods for analyzing and displaying gated SPECT data in 2- and 3-dimensional presentations for regional and global cardiac assessment have not been established. METHODS AND RESULTS: We have developed an automated quantitative method for assessing perfusion and function by means of technetium-99m sestamibi gated SPECT with a computerized technique combining count-based and image-based methods. We have examined its validity in 91 patients by comparing its results with those of conventional techniques: contrast left ventriculography and radionuclide angiocardiography. In addition to color-scale displays of regional function, simultaneous 3-dimensional presentations of regional wall motion and perfusion have been produced. High reproducibility of gated SPECT analysis with this algorithm was demonstrated; interoperator errors (%CV) were 2.6% to 5.5%, and good intraobserver reproducibility was confirmed by means of high correlation coefficients (0.954 to 0.989). Left ventricular volumes assessed by means of contrast left ventriculography and by means of the gated SPECT technique showed significant correlations (left ventricular end-diastolic volume, y = 1.01x - 9.7, r = 0.845, P<.001, standard errors of the estimate [SEE] = 14 mL; left ventricular end-systolic volume, y = 1.03x - 1.4, r = 0.902, P<.001, SEE = 6 mL). Left ventricular ejection fraction determined by means of gated SPECT with the new algorithm closely correlated with that determined by means of radionuclide ventriculography (y = 1.05x - 0.6, r = 0.891, P<.001, SEE = 3 %). These parameters quantified by means of the present method correlated closely with those derived from the QGS program (r = 0.926 to 0.987). CONCLUSION: In comparison with conventional techniques, myocardial gated SPECT with automated quantitative analysis provides accurate and reproducible data for global and regional function. Quantitative concurrent assessment of myocardial perfusion and function by using 2-and 3-dimensional representations appears to be superior to other modalities and to contribute to nuclear cardiology practice.

Adult↗