Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “biosensing”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8Linked to original sources

Template synthesis of highly ordered Prussian blue array and its application to the glucose biosensing.

In this paper, we propose a strategy to form nanoelectrode arrays by electrochemical deposition of the Prussian blue (PB) through highly ordered porous anodic alumina (PAA) membrane. The structure and morphology of the nanoarrays were characterized by scanning electron microscopy (SEM). As the highly ordered PB arrays can behave as an ensemble of closely spaced but isolated nanoelectrodes, the nanostructured PB arrays are successfully applied to improve the analytical performances of glucose by electrocatalytic reduction enzymatically liberated H(2)O(2). The resulting PB based nanoelectrode arrays show a wide linear calibration range over three orders of magnitude of glucose concentrations (5.0 x 10(-6) to 8.0 x 10(-3)M) and a low detection limit of 1 microM. Moreover, the biosensor exhibits other good characteristics, such as short response time, high selectivity, excellent operation stability. In addition, effects of the glucose oxidase (GOx) loading, applied potential and pH on the biosensor performance were also discussed.

Biosensing Techniques↗

Nanosized flower-like ZnO synthesized by a simple hydrothermal method and applied as matrix for horseradish peroxidase immobilization for electro-biosensing.

Nanosized flower-like ZnO was synthesized by a simple hydrothermal method which is a convenient, environment friendly, inexpensive and efficient process. Raman spectroscopy, X-ray diffraction (XRD) and scanning electron microscope (SEM) were used to confirm the material structure and the crystallite microstructure. Then ZnO was dispersed in the chitosan solution to form a ZnO/chitosan composite matrix for the fabrication of H2O2 biosensor. This composite combined the advantages of inorganic species (ZnO) and organic polymer (chitosan). The parameters affecting the fabrication and experimental conditions of biosensors were optimized. Using hydroquinone as the mediator, the biosensor showed a fast response of less than 5s with the linear range of 1.0x10(-5) to 1.8x10(-3) M H2O2 with a correlation coefficient of 0.995 (n=20). The detection limit of the sensor was found to be 2.0 microM, based on a signal-to-noise ratio of 3. The biosensor exhibited satisfactory reproducibility and stability and retained about 78% of its original response after 40 days storage in a phosphate buffer at 4 degrees C.

Biosensing Techniques↗

Multi-analyte surface plasmon resonance biosensing.

Surface plasmon resonance (SPR) biosensors are affinity sensing devices exploiting a special mode of electromagnetic field-surface plasmon-polariton-to detect the binding of analyte molecules from a liquid sample to biomolecular recognition elements immobilized on the surface of the sensor. In this paper, we review advances of SPR biosensor technology towards detection systems for the simultaneous detection of multiple analytes (multi-analyte detection). In addition, we report application of a recently developed multichannel SPR sensor based on spectroscopy of surface plasmons and wavelength division multiplexing of sensing channels to multi-analyte detection.

Biosensing Techniques↗

Investigation of interactions of a resorcin[4]arene receptor with bilayer lipid membranes (BLMs) for the electrochemical biosensing of mixtures of dopamine and ephedrine.

The present article investigates the interactions of a resorcin[4]arene receptor with planar bilayer lipid membranes (BLMs) that can be used for the electrochemical detection of dopamine and ephedrine. BLMs were composed of egg phosphatidylcholine and 35% (w/w) dipalmitoyl phosphatidic acid in which the receptor was incorporated. These BLMs modified with the resorcin[4]arene receptor can be used as one-shot sensors for the direct electrochemical sensing of these energizing-stimulating substances. The interactions of these compounds with the lipid membranes were found to be electrochemically transduced in the form of a transient current signal with a duration of seconds, which reproducibly appeared within 8 and 20 s after exposure of the membranes to dopamine and ephedrine, respectively. The response time for BLMs without the receptor for dopamine was about 3 min, whereas no signals were obtained for ephedrine in the absence of the receptor. The mechanism of signal generation was investigated by differential scanning calorimetric studies. These studies revealed that the adsorption of the receptor is through the hydrophobic tails of the receptor, whereas hydrophilic groups of the receptor were directed towards the electrolyte solution enhancing the ion transport through the lipid membranes. The magnitude of the transient current signal was related to the concentration of the stimulating agent in bulk solution in the micromolar range. No interferences from ascorbic acid were noticed because of the use of the negatively charged lipids in membranes. The present technique can be used as one-shot sensor for the detection of these pharmaceutical substances and future research is targeted to the determination of these chemicals in human biofluids such as urine of athletes.

Biosensing Techniques↗

Surprisingly fast disappearance of beta-lactam selection pressure in cultivation as detected with novel biosensing approaches.

Tetracycline and beta-lactam resistances among others are used as selection markers in the production of recombinant proteins. The beta-lactam resistance is based on degradation, i.e. the selection pressure gradually disappears from the culture, whereas tetracycline resistance is based on active efflux. We have studied the kinetics of the stability of antibiotic selection pressure in culture using a simple model system (pBR322 in Escherichia coli). Concentrations of ampicillin, carbenicillin and tetracycline were measured with novel sensor cells developed in our lab. These cells are specifically induced to produce light in the presence of the drugs and here their performance was shown to be excellent in monitoring antibiotic concentrations in cell culture. The sensor cells are cheap to produce and use and a high number of samples can be analysed simultaneously. To our surprise, ampicillin and carbenicillin were completely degraded after 2.5-3.0 h of culture, although it has been widely claimed that especially carbenicillin is a good selective agent, whereas tetracycline was stable in culture. beta-lactamase activity in culture was found to correlate with the kinetics of ampicillin degradation.

Anti-Bacterial Agents↗

Surface plasmon resonance based pesticide assay on a renewable biosensing surface using the reversible concanavalin A monosaccharide interaction.

A competitive immunoassay based on surface plasmon resonance (SPR) for the detection of the pesticide 2,4-dichlorophenoxyacetic acid (2,4-D) is reported. The novelty of the assay is based on the regeneration of the chip surface by the reversible interaction between monosaccharide (D-glucose) and lectin (Concanavalin A). Concanavalin A-2,4-D conjugate was chemically synthesized, purified and used for binding to the SPR chip modified with covalently bound alpha-D-glucose. The interaction between anti-2,4-D antibody and the surface-bound concanavalin A-2,4-D conjugate was monitored by surface plasmon resonance and the response was used for the quantification of 2,4-D. The dynamic range of the calibration curve was between 3 and 100 ng/ml. The demonstrated principle of surface regeneration based on the reversible sugar-lectin interaction may be of more general applicability in immunoassays.

2,4-Dichlorophenoxyacetic Acid↗

On-line microbial biosensing and fingerprinting of water pollutants.

The potential for biosensors to contribute to on-line toxicity testing for monitoring of water quality is currently constrained both by the relevance of the biosensors available and the technology for biosensor delivery. This paper reports the use of novel slow release biosensor delivery for on-line monitoring instrumentation, with environmentally relevant bacteria for both simple toxicity testing and more complex toxicity fingerprinting of industrial effluents. The on-line toxicity test, using bioluminescence-based biosensors, proved to be as sensitive and reliable as the corresponding batch test, with comparable contaminant EC(50) values from both methods. Toxicity fingerprinting through the investigation of the kinetics (dose-response) and the dynamics (response with time) of the biosensor test response proved to be diagnostic of both effluent type and composition. Furthermore, the slow release of biosensors immobilised in a polyvinyl alcohol (PVA) matrix greatly improved biosensor delivery, did not affect the sensitivity of toxicity testing, and demonstrated great potential for inclusion in on-line monitoring instrumentation.

Biosensing Techniques↗

Highly sensitive biosensing using a supercritical angle fluorescence (SAF) instrument.

We present a new optical biosensor for probing molecular binding to a water/glass interface. The system is designed to measure the kinetics of surface reactions down to low analyte concentrations straightforwardly. The selective detection of surface bound fluorescence is achieved by collecting supercritical angle fluorescence (SAF) emission of surface bound molecules into the glass. Thereby the expansion of the detection volume into the aqueous probe is reduced to about one sixth of the fluorescence wavelength, consequently bulk fluorescence from the solution is rejected successfully. The SAF-signal is captured by a parabolic glass lens, which leads to high spatial collection efficiency and detection sensitivity. The sensor has an inverted optical design and is compatible with common glass cover slips, which strongly facilitates operation for the user working in the biological and biochemical fields. The performance of the system is demonstrated by real time measurements of antibody-antigen reactions. Rate constants of the reaction were extracted. Antigen concentrations were detected down to 10(-13) mol/l.

Antigen-Antibody Complex↗

Real time device for biosensing: design of a bacteriophage model using love acoustic waves.

Love wave sensors (ST-cut quartz substrate with interdigital transducers, SiO(2) guiding layer and sensitive coating) have been receiving a great deal of attention for a few years. Indeed, the wave coupled in a guiding layer confers a high gravimetric sensitivity and the shear horizontal (SH) polarization allows to work in liquid media. In this paper, an analytical method is proposed to calculate the Love wave phase velocity and the gravimetric sensitivity for a complete multilayer structure. This allows us to optimize the Love wave devices design in order to improve their gravimetric sensitivity in liquid media. As a model for virus or bacteria detection in liquids (drinking or bathing water, food em leader ) we design a model using M13 bacteriophage. The first step is the anti-M13 (AM13) monoclonal antibody grafting, on the device surface (SiO(2)). The second step is an immunoreaction in between the M13 bacteriophage and the AM13 antibody. The Love wave device allows to detect in real time the graft of the AM13 sensitive coating, as well as the immobilization of the M13 bacteriophages. With a pH change, the M13 bacteriophages can be removed from the sensor surface, in order to be numerated as plaque forming unit (pfu). Results on the sensitivity of Love waves are compared with similar immunological works with bulk acoustic wave devices, and demonstrate the high potentialities of Love waves sensors.

Acoustics↗

Microplate based biosensing with a computer screen aided technique.

Melanophores, dark pigment cells from the frog Xenopus laevis, have the ability to change light absorbance upon stimulation by different biological agents. Hormone exposure (e.g. melatonin or alpha-melanocyte stimulating hormone) has been used here as a reversible stimulus to test a new compact microplate reading platform. As an application, the detection of the asthma drug formoterol in blood plasma samples is demonstrated. The present system utilizes a computer screen as a (programmable) large area light source, and a standard web camera as recording media enabling even kinetic microplate reading with a versatile and broadly available platform, which suffices to evaluate numerous bioassays. Especially in the context of point of care testing or self testing applications these possibilities become advantageous compared with highly dedicated comparatively expensive commercial systems.

Animals↗

Reagentless biosensing using electrochemical impedance spectroscopy.

The use of electrochemical impedance spectroscopy (EIS) and the conducting polymer, poly (pyrrole), as an integrated recognition and transduction system for reagentless biosensor systems was demonstrated with two different systems. The first system being an immunoassay for detection of luteinising hormone (LH) with the antibody being entrapped with in the poly (pyrrole) matrix and the second, a construct for DNA hybridisation discrimination able to differentiate single- and double-stranded DNA based on the interaction of the DNA with poly (pyrrole).

Biosensing Techniques↗

Hydrogel network entrapping cholesterol oxidase and octadecylsilica for optical biosensing in hydrophobic organic or aqueous micelle solvents.

Two optical cholesterol biosensors have been fabricated by immobilizing cholesterol oxidase (ChOx) and octadecylsilica (ODS) particles in hydrogel network matrixes of copolymer of poly(vinyl alcohol) (PVA)/hydroxyethyl carboxymethyl cellulose (HECMC), and sol-gel, respectively. In conjunction with an optical oxygen transducer, the immobilized ChOx in the sol-gel/ODS matrix was assembled as an optical cholesterol biosensor to continuously detect free cholesterol in aqueous micelle solution, while the immobilized ChOx in the PVA/HECMC/ODS matrix was constructed as an organic-phase optical cholesterol biosensor for the continuous analysis of free cholesterol in hydrophobic organic solvent. The compositions and properties of the immobilization matrixes, the effects of solvents and the analytical features were studied in detail. Both biosensors showed stable and reliable responses toward free cholesterol. For the aqueous micelle cholesterol biosensor, the analytical working range was from 0.05 to 8.0 mM cholesterol, the response time was 7-12 min, the operation life was more than 35 assays, and the shelf life was approximately 4 months. For the organic-phase cholesterol biosensor, the analytical working range was from 0.07 to 18.0 mM cholesterol, the response time was 4-8 min, the operation life was more than 120 assays, and the shelf life was longer than 5 months. The organic-phase cholesterol biosensor has been successfully applied to determine the free cholesterol content in commercial butter samples.

Biosensing Techniques↗

A biosensing system based on extracellular potential recording of ligand-gated ion channel function overexpressed in insect cells.

We have used outer cell potential measurement to record agonist-dependent cellular responses in cells engineered to express ligand-gated ion channels and grown on a microelectrode surface. Application of glutamate, a natural agonist, induced a complex and robust potentiometric response in cells expressing homomeric GluR-D glutamate receptor, but not in nonexpressing control cells. The response consisted of an initial decrease in outer potential followed by a transient increase and was not obtained for other amino acids devoid of agonist activity at glutamate receptors. Furthermore, the pharmacological agonist of the GluR-D receptor, kainate, also produced the potentiometric response whereas 6-cyano-7-nitroquinoxaline-2,3-dione, a competitive antagonist, was not active in itself but attenuated the responses to glutamate. The time course of the measured changes was slow, which may be partially due to the ligand being applied by free diffusion but may also reflect a contribution by secondary changes in the behavior of the cells. This novel approach should be applicable to other ligand-gated ion channels and holds promise as a cell-based biosensor for high-throughput drug screening and other applications.

Animals↗

Electrochemical biosensing platforms using platinum nanoparticles and carbon nanotubes.

Platinum nanoparticles with a diameter of 2-3 nm were prepared and used in combination with single-wall carbon nanotubes (SWCNTs) for fabricating electrochemical sensors with remarkably improved sensitivity toward hydrogen peroxide. Nafion, a perfluorosulfonated polymer, was used to solubilize SWCNTs and also displayed strong interactions with Pt nanoparticles to form a network that connected Pt nanoparticles to the electrode surface. TEM and AFM micrographs illustrated the deposition of Pt nanoparticles on carbon nanotubes whereas cyclic voltammetry confirmed an electrical contact through SWCNTs between Pt nanoparticles and the glassy carbon (GC) or carbon fiber backing. With glucose oxidase (GOx) as an enzyme model, we constructed a GC or carbon fiber microelectrode-based biosensor that responds even more sensitively to glucose than the GC/GOx electrode modified by Pt nanoparticles or CNTs alone. The response time and detection limit (S/N = 3) of this biosensor was determined to be 3 s and 0.5 microM, respectively.

Aspergillus niger↗

Surface plasmon enhanced diffraction for label-free biosensing.

Surface plasmon enhanced evanescent field at a (noble) metal/dielectric interface can be employed to enhance the diffraction efficiency of surface grating structure composed of biomolecules. Based on a Kretschmann configuration, we realized a diffraction biosensor to monitor the dynamic interaction of biological molecules in a label-free way. It was demonstrated by the binding of an anti-biotin antibody to the biotin-functionalized region of a periodically patterned surface, which generated significant optical contrast to diffract the surface plasmon field. With the aid of the synchronic surface plasmon resonance signal, a quadratic dependence of diffraction signal on the amount of bound antibody was found, which coincides with the theoretical expectation. Time-dependent measurements were conducted to estimate the density of biotin thiols on the functional region.

Antibodies, Monoclonal↗

Determination of picomolar concentrations of metal ions using fluorescence anisotropy: biosensing with a "reagentless" enzyme transducer.

Because of their high affinity and selectivity, metalloproteins can be used as transducers in novel sensors, i.e., biosensors, for the determination of trace levels of metal ions in solution. Here, we exploit carbonic anhydrase to determine picomolar to nanomolar concentrations of free transition metal ions by fluorescence anisotropy (polarization) in a reagentless format. Carbonic anhydrase variants engineered with a cysteine replacing a residue chosen near the active site (F131C and H64C) were covalently labeled with derivatives of benzoxadiazole sulfonamide. These labeled variants exhibited changes in anisotropy up to 0.07 upon binding free Cu(II), Co(II), and Zn(II) with apparent Kd's close to the values observed with wild-type apocarbonic anhydrase. The covalent attachment of the label has significant advantages over noncovalent labels we have described previously. Furthermore, the metal ion-dependent anisotropy changes were predictable using simple theory. The results demonstrate that free transition metal ions can be determined at trace levels in aqueous solution using inexpensive instruments.

Anisotropy↗

Green fluorescent protein in the design of a living biosensing system for L-arabinose.

Analysis of monosaccharides is typically performed using analytical systems that involve a separation step followed by a detection step. The separation step is usually necessary because of the high degree of structural similarity between different monosaccharides. A novel sensing system for monosaccharides is described here in which living bacteria were designed to detect a model monosaccharide, L-arabinose, without the need for a separation step. In such sensing systems, analytes are detected by employing the selective recognition properties found in certain bacterial proteins. These systems are designed so that a reporter protein is expressed by the bacteria in response to the analyte. The concentration of the analyte can be related to the signal generated by the reporter protein. In the sensing system described here, the green fluorescent protein (GFP) was used as the reporter protein. L-Arabinose concentrations can be determined by monitoring the fluorescence emitted by the bacteria at 509 nm after excitation of GFP at 395 nm. The system can detect L-arabinose at concentrations as low as 5 x 10(-7) M and is selective over D-arabinose, the stereoisomer of the analyte, as well as over a variety of pentose and hexose sugars.

AraC Transcription Factor↗