Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Torque”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8Linked to original sources

The relationship between torque and joint angle during knee extension in boys and men.

The length-tension relationship of muscle contraction is well documented in adults. However, research on this relationship in children has been limited. The aim of this study was to compare differences in the torque-joint angle relationship of the quadriceps muscle in children and adults. Eight boys aged 8-10 years and eight men aged 20-26 years performed two maximal voluntary isometric contractions at six knee joint angles (20 degrees, 40 degrees, 60 degrees, 80 degrees, 90 degrees, 100 degrees). The mean of the two trials was used as the performance measure. Both groups demonstrated an expected increase in relative torque as the joint angle increased (P< 0.05). The men produced significantly greater relative torque at 20 degrees, 40 degrees and 60 degrees knee flexion (P < 0.05). The percentage of maximal torque at these angles for the men and boys respectively were: 35.2+/-4.3 vs 15.2+/-12%, 63.6+/-9.1 vs 51.8+/-16.8% and 93.6+/-6.5 vs 84.4+/-14.4%. There were no group differences at 80 degrees or 90 degrees. Peak torque was attained at 80 degrees in men, but decreased significantly (P< 0.05) at 90 degrees and 100 degrees. For boys, peak torque was attained at joint angles of 80 degrees and 90 degrees. The reduction in peak torque at 100 degrees was not statistically significant, but the relative torque at this angle was lower in men than in boys (77.9+/-13.7 vs 87.1+/-10.4%; P< 0.05). In conclusion, the relationship between torque and joint angle appears to be affected by age.

Adult↗

Role of joint torques generated in an optimised Yurchenko layout vault.

The purpose of the study was to quantify the muscle torques required in the performance of an optimised Yurchenko layout vault based on a five-segment rigid link model and using input data from an elite female gymnast. At impact, the wrist torque trajectory indicated an extension-flexion action while the shoulder was characterised by extension. The approximate 100 Nm (wrist flexor) and 125 Nm (shoulder extensor) respective peak torque magnitudes indicated that the impact action is not passive in nature. The contribution of joint torques to the adjoining segments was apportioned to the relative components namely; centripetal, gravity and net joint torque components. Despite the presence of both large wrist and shoulder joint torques, the net turning effect on the upper limb and hand segments about their centre of mass (CM) was small. The principal role of the upper limb joint torques was therefore to effect the appropriate joint motions and to support the weight of the gymnast. The performance of the optimum vault was primarily the result of the interplay between the centripetal and the net joint torque components at the wrist, hip and shoulder joints. This has implications to the performer in that successful execution of the vault is principally concerned with the ability to create a high angular momentum for horse impact and to then apply an appropriate level of joint torques that will make optimal use of the initial kinetic condition.

Algorithms↗

Is eccentric exercise-induced torque decrease contraction type dependent?

PURPOSE: This study was designed to determine whether torque decrease following an acute eccentric exercise is contraction type dependent. METHODS: Ten active males performed an exercise session consisting of five sets of ten maximal eccentric muscle actions of the elbow flexors. Before and immediately after the exercise, maximal voluntary eccentric (-60 degrees.s-1; Ecc60), isometric (0 degrees.s-1; Iso) and concentric (60 degrees.s-1; Con60 and 240 degrees.s-1; Con240) torque were measured. In order to distinguish central from peripheral factors involved in torque decrement, activation level (twitch interpolation technique), myoelectrical activity (RMS) of biceps brachii, as well as electrically evoked M-wave and peak twitch torque (Pt) were recorded. RESULTS: The eccentric exercise induced a significant torque reduction (P < 0.01), whatever the muscular contraction type [mean (SD): -22.3 (8.1)% for Ecc60; -20.8 (11.2)% for Iso; -18.5 (6.1)% for Con60 and -12.5 (8.9)% for Con240]. Relative torque decrement was however significantly less for Con240 compared with Ecc60, Iso, and Con60 (P < 0.05). Torque decreases were associated with a reduction of both M-wave amplitude (P < 0.01) and Pt (P < 0.001), probably related to an impairment of the excitation-contraction coupling. Concurrently, activation level was reduced (P < 0.01), therefore indicating the occurrence of central fatigue, as also confirmed by RMS decreases for all the conditions (P < 0.05), except Con240. DISCUSSION: An acute eccentric exercise induced a significant voluntary maximal torque reduction during eccentric, isometric, and concentric muscle actions ascribed to both peripheral and central failure of force production capacity. It can be concluded that eccentric exercise-induced torque decrease is not contraction type dependent.

Adult↗

Insertion torque profile during pedicle screw insertion of the thoracic spine with and without violation of the pedicle wall: comparison between cylindrical and conical designs.

STUDY DESIGN: Biomechanical study in human cadaveric thoracic spines. OBJECTIVE: To compare the insertion torque profile of cylindrical and conical screws with normal insertion tract, and with violation of the pedicle. SUMMARY OF BACKGROUND DATA: Previous studies revealed higher insertion torque for conical screws. No study has investigated the torque profile of both screws when there is violation of the pedicle. METHODS: The pedicle screws were inserted intrapedicularly (Type 1), violating the lateral cortex of the pedicle (Type 2), and violating the medial cortex of the pedicle (Type 3). Type 2 screws were further subdivided into those having contact with the lateral vertebral body (2a) and those without (2b). Type 3 screws were subdivided into those having contact with the medial pedicle wall (3a) and without (3b). RESULTS.: During initial insertion, the torque increased as they penetrated into the pedicles. With violation of the lateral cortex of the pedicle, insertion torque for the cylindrical screw decreased as the screw advanced anteriorly out of the pedicle. The insertion torque for the conical screw continued to increase at a constant rate after violation of the lateral cortex. With medial breach of the pedicle wall, torque profile of the conical screws remained the same as those inserted in the normal trajectory. There was a decline in the insertion torque for the cylindrical screws when medial violation of the pedicle wall occurred, the decrease being greater for Type 3b as compared with Type 3a screws. CONCLUSIONS: Surgeons may be unable to perceive the occurrence of medial or lateral breach of the cortex when inserting a conical screw. Surgeons inserting cylindrical screws with Type 3a violation may not be able to perceive a significant decrease in torque.

Bone Screws↗

Experimental joint contracture correction with low torque--long duration repeated stretching.

Tension is necessary to maintain and restore the mechanical properties of soft connective tissues. Conversely, reduced tension states such as produced by immobilization weaken mechanical properties and facilitate joint contracture. We assessed the effect of low torque-long duration stretching to increase the range of motion (ROM) and to restore the mechanical properties of contracted joints in 66 rat knees immobilized for 40 days. After remobilization, we randomly divided the contracted knees into four treatment groups treated with repeated stretches of diverse torques and duration: stretching with low-torque and long-duration, high-torque and short-duration, high-torque and long-duration, low-torque and short duration. We included control and natural recovery groups. Phase lag in all treatment groups recovered to the same range as in the normal controls. Dynamic stiffness, which was not altered by joint immobilization, increased in all treatment groups. Deformation and load to failure improved substantially only in the low-torque and long-duration stretching group. Low-torque and long-duration repeated stretching leads to a greater restoration of ROM with more normal mechanical properties compared to high-torque and short duration stretching.

Animals↗

On cutting torque measurements during implant placement: a 3-year clinical prospective study.

BACKGROUND: Evaluation of jaw bone quality at implant placement is mainly based on preoperative radiographic assessments and subjective hand registrations during implant site preparation. An objective technique with cutting torque measurements has been introduced, presenting an objective bone quality or bone hardness value of individual implant sites. PURPOSE: The purpose of this study was to evaluate cutting torque measurements during implant placement and to compare these values in different regions in mandibles and maxillae. The objective was to identify implants at risk for failing at implant placement. MATERIAL AND METHODS: Cutting torque measurements were performed during placement of Mk II self-tapping implants (Brånemark System) in 105 patients, comprising 72 edentulous (40 maxillae) and 34 partially edentulous (22 maxillae) jaws. A total of 523 implants were inserted, of which 420 were of the Mk II design and of which 412 were subjected to cutting torque measurements. Statistical analyses were performed by comparing cutting torque values of maxillae and mandibles and of different jaw regions. Cutting torque values were also correlated with radiographically and clinically assessed bone quality scores. Patients were followed clinically for a minimum of 3 years. RESULTS: A statistically significant difference in cutting torque values of maxillae and mandibles was seen, although not when comparing anterior and posterior regions within the same jaws or of different jaws. Significant correlations were found between values of cutting torque and bone quality. The majority of failures were seen in bone of medium to high density, whereas implants inserted in bone of poor density presented a better outcome, perhaps due to an adapted surgical protocol and an extended healing period. The overall implant survival rate at 3 years was 95%, and when analyzing different jaw categories, survival rates of 92.0% and 99.4% were seen for edentulous maxillae and mandibles, respectively. The corresponding figures for partially edentulous jaws were 95.4% and 97.6%. CONCLUSION: It was not possible to identify sites at risk for future implant losses or to determine a lower limit value of cutting torque in order to achieve successful implant integration.

Adolescent↗

Spike-triggered average torque and muscle fiber conduction velocity of low-threshold motor units following submaximal endurance contractions.

The motor unit twitch torque is modified by sustained contraction, but the association to changes in muscle fiber electrophysiological properties is not fully known. Thus twitch torque, muscle fiber conduction velocity, and action potential properties of single motor units were assessed in 11 subjects following an isometric submaximal contraction of the tibialis anterior muscle until endurance. The volunteers activated a target motor unit at the minimum discharge rate in eight 3-min-long contractions, three before and five after an isometric contraction at 40% of the maximal torque, sustained until endurance. Multichannel surface electromyogram signals and joint torque were averaged with the target motor unit potential as trigger. Discharge rate (mean +/- SE, 6.6 +/- 0.2 pulses/s) and interpulse interval variability (33.3 +/- 7.0%) were not different in the eight contractions. Peak twitch torque and recruitment threshold increased significantly (93 +/- 29 and 12 +/- 5%, P <0.05) in the contraction immediately after the endurance task with respect to the preendurance values (0.94 +/- 0.26 mN.m and 3.7 +/- 0.5% of the maximal torque), whereas time to peak of the twitch torque did not change (74.4 +/- 10.1 ms). Muscle fiber conduction velocity decreased and action potential duration increased in the contraction after the endurance (6.3 +/- 1.8 and 9.8 +/- 1.8%, respectively, P <0.05; preendurance values, 3.9 +/- 0.2 m/s and 11.1 +/- 0.8 ms), whereas the surface potential peak-to-peak amplitude did not change (27.1 +/- 3.1 microV). There was no significant correlation between the relative changes in muscle fiber conduction velocity or surface potential duration and in peak twitch torque (R2= 0.04 and 0.10, respectively). In conclusion, modifications in peak twitch torque of low-threshold motor units with sustained contraction are mainly determined by mechanisms not related to changes in action potential shape and in its propagation velocity.

Action Potentials↗

Influence of joint position on electromyographic and torque generation during maximal voluntary isometric contractions of the hamstrings and gluteus maximus muscles.

STUDY DESIGN: Repeated measures analysis of joint angle effects on hip and knee muscle electromyographic (EMG) activity. OBJECTIVES: To simultaneously determine angle-dependent changes in maximal voluntary isometric contraction (MVIC) torque and EMG activity during hip extension and knee flexion. BACKGROUND: Procedures for normalizing EMG data and for determining torque-angle relationships for various joint motions both entail asking subjects to exert an MVIC. The implicit assumption in these paradigms is that magnitude of the EMG response is at a constant, maximum level so that observed angle-dependent variations in torque are due to mechanical factors, such as muscle length and muscle moment arm. METHODS AND MEASURES: Fifty subjects (25 men and 25 women) participated in this study (age, 23.5 +/- 4.6 y; range, 18-38 y). Subjects performed maximal isometric knee flexion at 4 knee angles and maximal isometric hip extension at 4 hip angles. The dependent variables were normalized root-mean-square EMG and torque. The process for normalizing EMG and torque data consisted of determining the largest mean value for each subject across testing positions for the muscle of interest. That value was designated as corresponding to 100% MVIC, and all other data for that muscle were expressed as a percentage of the MVIC value. Repeated measures was used to determine angle-dependent changes in normalized MVIC-torque and MVIC-EMG values for each muscle group. RESULTS: Mean torque-angle relationships were generally consistent with previous reports, though considerable intersubject variability was observed. There were significant angle-dependent differences in maximal EMG for both the hamstring and gluteus maximus muscles. Mean percentages of hamstring MVIC-EMG at knee angles of 30 degrees (81 +/- 19) and 60 degrees (82 +/- 22) were greater than at 0 degrees (68 +/- 20) or 90 degrees (74 +/- 20). The mean percentage of gluteus maximus MVIC-EMG at a hip angle of 0 degrees (94 +/- 10) was greater than at 30 degrees (84 +/- 13), 60 degrees (80 +/- 14), or 90 degrees (64 +/- 20), and gluteus maximus maximal voluntary isometric EMG at 90 degrees was less than at all other angles. These differences could not be explained solely by muscle length-dependent effects on EMG amplitude, suggesting that despite instructions for maximal effort, motor unit activation was not maintained at a constant, maximal level throughout the range of motion. The form of the EMG/angle relationships differed markedly from the torque-angle relationships. CONCLUSIONS: These findings have implications for the use of MVIC-EMG for reference values in EMG normalization procedures and for the interpretation of mechanisms underlying the torque-angle relationships observed in vivo.

Adult↗

The effect of hand-grip stabilization on isokinetic torque at the knee.

Isokinetic dynamometers commonly measure muscle strength during conditioning and rehabilitation. Previous studies have shown that stabilization can affect isokinetic torque production. However, the effect of stabilization with hand-grip use has not been examined, and there are inconsistencies in the literature regarding its use. Fifteen men (mean age +/- SD = 24 +/- 3 years, height = 187 +/- 6 cm, mass = 84 +/- 10 kg) and 15 women (age = 25 +/- 4 years, height = 167 +/- 8 cm, mass = 62 +/- 6 kg) were tested on a Cybex 6000 dynamometer. Torque and joint angle signals, as well as quadriceps and hamstrings electromyographic (EMG) signals, were recorded during maximal knee flexion/extension at speeds of 60, 180, and 300 degrees x s(-1). Subjects performed the testing both with (stabilized) and without (nonstabilized with arms folded across the chest) hand-grip use. Repeated-measures analysis of variance (ANOVA) revealed a significant-motion (flexion, extension), X-condition (stabilized, non-stabilized) interaction in the data from the men in which hand-grip stabilization resulted in an 8.4% increase in knee extensor torque vs. a 0.2% increase in knee flexor torque. Stabilization did not significantly affect torque in women. The EMG analyses did not indicate a significant change in either agonist drive or antagonist cocontraction that accounted for the enhanced torque output with hand-grip use. This study found that hand-grip use enhanced knee extension maximal torque in men, but did not affect torque in women. The EMG data did not account for the changes in the torque data. Differences between men and women may have been due to mechanical factors and grip strength. These results indicate that hand-grip use needs to be considered when examining gender differences in knee strength and when studying knee flexion-extension ratios.

Adult↗

The organization of torque and EMG activity during bilateral handle pulls by standing humans.

This study examined whether the torques and EMG activity that precede and accompany bilateral arm pulls made by standing humans demonstrate a pulse height form of organization. Nine adults made abrupt bilateral pulls in the sagittal plane against a handle, to force targets equal to 5, 10, 20, 40, 60, 80 and 95% of their maximal pulling force (%MPF). The force applied at the handle, ground reaction forces, the center of pressure (CP), and EMG activity in gastrocnemius (GS), biceps femoris (BF), tibialis anterior (TA) and quadriceps (QD) muscles were recorded. Our analysis divided the action into a pre-pull phase (events prior to the increase of handle force) and a pulling phase (while handle force was greater than zero). We evaluated the effects of %MPF on the durations and peak amplitudes of the pre-pull and pulling angular impulses about the ankle joint and on pre-pull EMG patterns. The results showed that the angular impulse associated with the pulling torque (due to the reactive force on the body during the pull) had a pulse height organization: peak torque increased linearly with %MPF, and the durations of the pulling torque were relatively constant. In contrast, a pulse height organization did not characterize the pre-pull period for either the angular impulse associated with ankle torque (due to net ground reaction force) or EMG activity in the leg muscles. Rather, peak ankle torque typically increased up to some submaximal %MPF and then plateaued, perhaps due to a constraining effect on foot length on CP. The durations of pre-pull ankle torques increased over the whole range of %MPF, thereby compensating for the limit on ankle torque. Depending on the subject, the muscles were recruited in two different orders: GS-BF-TA-QD, or GS-TA-BF-QD. As the %MPF increased, the EMG onset times of all four muscles occurred earlier, and there was a greater likelihood that the BF, TA and QD muscles would be recruited on a given trial. The changes in the ankle torque and EMG patterns were gradual, suggesting that the pre-pull phase could have one underlying form of organization, with parameters that are tuned to task goals and anatomical constraints.

Adult↗

Influence of gastrocnemius muscle length on triceps surae torque development and electromyographic activity in man.

The present study was designed to determine the relative contribution of the gastrocnemius muscle to isometric plantar flexor torque production at varying knee angles, while investigating the activation of the gastrocnemius muscle at standardised non-optimal lengths. Voluntary plantar flexor torque, supramaximally stimulated twitch torque and myoelectric activity (EMG) from the triceps surae were measured at different knee angles. Surface and intra-muscular EMG were recorded from the soleus muscle and the medial and lateral heads of the gastrocnemius muscle in 10 male subjects. With the ankle angle held constant, knee angle was changed in steps of 30 degrees ranging from 180 degrees (extended) to 60 degrees (extreme flexion), while voluntary torque from a 5-s contraction was determined at 10 different levels of voluntary effort, ranging from 10% of maximal effort to maximal effort. To assess effort, supramaximal twitches were superimposed on all voluntary contractions, and additionally during rest. Maximal plantar flexor torque and resting twitch torque decreased significantly in a sigmoidal fashion with increasing knee flexion to 60% of the maximum torque at 180 degrees knee angle. For similar levels of voluntary effort, the EMG root mean square (RMS) of gastrocnemius was less with increased knee flexion, whereas soleus RMS remained unchanged. From these data, it is concluded that the contribution of gastrocnemius to plantar flexor torque is at least 40% of the total torque in the straight leg position. The decrease of gastrocnemius EMG RMS with decreasing muscle length may be brought about by a decrease in the number of fibres within the EMG electrode recording volume and/or impaired neuromuscular transmission.

Adult↗

The effect of movement direction on joint torque covariation.

It has been proposed that unconstrained upper limb movements are coordinated via a kinetic constraint that produces dynamic muscle torques at each moving joint that are a linear function of a single torque command. This constraint has been termed linear synergy (Gottlieb et al. J Neurophysiol 75:1760-1764, 1996). The current study tested two hypotheses: (1) that the extent of covariation between dynamic muscle torques at the shoulder and elbow varied with the direction of movement and (2) that the extent to which muscle torques deviated from linear synergy would be reproduced by a simulation of pointing movements in which the path of the hand was constrained to be straight. Dynamic muscle torques were calculated from sagittal plane pointing movements performed by 12 participants to targets in eight different directions. The results of principal component analyses performed on the muscle torque data demonstrated direction-dependent variation in the extent to which dynamic muscle torques covaried at the shoulder and elbow. Linear synergy was deviated from substantially in movement directions for which the magnitude of muscle torque was low at one joint. A simulation of movements with straight hand paths was able to accurately estimate the amount of covariation between muscle torques at the two joints in many directions. These results support the idea that a kinematic constraint is imposed by the central nervous system during unconstrained pointing movements. Linear synergy may also be applied as a coordinating constraint in circumstances where its application allows the path of the moving endpoint to remain close to a straight line.

Adult↗

Effect of antagonist muscle fatigue on knee extension torque.

The effect of hamstring fatigue on knee extension torque was examined at different knee angles for seven male subjects. Before and after a dynamic flexion fatigue protocol (180 degrees s(-1), until dynamic torque had declined by 50%), maximal voluntary contraction extension torque was measured at four knee flexion angles (90 degrees, 70 degrees, 50 degrees and 30 degrees ). Maximal torque generating capacity and voluntary activation of the quadriceps muscle were determined using electrical stimulation. Average rectified EMG of the biceps femoris was determined. Mean dynamic flexion torque declined by 48+/-11%. Extensor maximal voluntary contraction torque, maximal torque generating capacity, voluntary activation and average rectified EMG at the four knee angles were unaffected by the hamstring fatigue protocol. Only at 50 degrees knee angle was voluntary activation significantly lower (15.7%) after fatigue ( P<0.05). In addition, average rectified EMG before fatigue was not significantly influenced by knee angle. It was concluded that a fatigued hamstring muscle did not increase the maximal voluntary contraction extension torque and knee angle did not change coactivation. Three possible mechanisms may explain the results: a potential difference in recruited fibre populations in antagonist activity compared with the fibres which were fatigued in the protocol, a smaller loss in isometric torque generating capacity of the hamstring muscle than was expected from the dynamic measurements and/or a reduction in voluntary activation.

Adult↗

Pneumatic tool torque reaction: reaction forces, displacement, muscle activity and discomfort in the hand-arm system.

Reaction forces, hand-arm displacement, muscle activity and discomfort ratings were studied during the securing of threaded fasteners with three angle nutrunners with different shut-off mechanisms, but with the same spindle torque (72-74 Nm). The three tools were tested according to the method specified in ISO 6544. One of the tools had an almost instantaneous shut-off. Another had a more slowly declining torque curve. For the third tool the maximum torque was maintained for a while before shut-off. Twelve male subjects participated in the study. A force platform measured the reaction force between the subject and the floor. The option of the hand-arm system and the shoulder was measured with an optoelectronic measuring system. The muscle activity (EMG) in six muscles in the arm and shoulder was measured with surface electrodes. Significant differences in the arm movements and ground reaction forces were found between the three tools. The smallest values were found with the fast shut-off tool while the delayed shut-off tool caused the largest values. The EMG measures gave inconsistent response patterns. Discomfort ratings were highly correlated with the time for which the tool torque exceeded 90% of peak preset torque, but the time for which the tool torque exceeded 90% of peak calculated by the method specified in ISO 6544. Nutrunners with a shut-off mechanism that causes a slowly decreasing torque or a torque that is maintained for a while before shut-off should be avoided. If no substitutes are available, then a torque reaction bar should be mounted on the tool.

Journal Article↗

Analysis of seating and fracturing torque of bicortical screws.

The purpose of this study was to analyze and compare the seating and fracturing torque of 2.0-mm- versus 2.7-mm-diameter titanium screws. Six cadaver mandibles were sectioned at the symphysis and 20 drill hole locations were chosen on each half. Half the holes were designated for the 2.0-mm screws, tapped and nontapped, and the remaining half for 2.7-mm screws, tapped and nontapped. The maximum torque leading to the screw seating or fracturing was recorded using an electric torque tester (Artech Reliance, Chantilly, VA). The mean maximum seating torque for the 2.7-mm screws, tapped and nontapped, was 30% of that measured for the 2.0-mm screws. The mean maximum seating torque for all tapped screws was 35% less than for all nontapped screws. The region of the mandible requiring the greatest seating torque was the symphysis, followed by the body, condyle, ramus, and angle. None of the 2.7-mm screws fractured; however, 10% of the 2.0-mm screws fractured. Three were located in the symphysis and one in the ramus. With the 2.0-mm screws that did not fracture, the seating torque in the nontapped holes was 59% greater than in the tapped holes. With the 2.0-mm screws that fractured, the mean maximum fracturing torque was 64% greater than for those screws that did not fracture. This study shows that small screws placed in the mandible require greater seating torque, regardless of whether the holes are tapped, and that there is an increased chance of small screws fracturing in certain regions.

Bone Density↗

Isokinetic peak torque in women with unilateral cumulative trauma disorders and healthy control subjects.

OBJECTIVES: To compare isokinetic peak torque in the symptomatic and asymptomatic limbs of women with lateral epicondyle or forearm pain due to cumulative trauma disorders (CTDs), and to compare peak torque in women with CTDs to peak torque in healthy women. DESIGN: Case control comparison. SETTING: Private occupational rehabilitation clinic and a sports science tertiary education center. SUBJECTS: Women with CTDs involving one arm (n=17) and a convenience sample of healthy women (n=7) INTERVENTION: Subjects performed isokinetic strength testing for wrist extension and flexion, wrist supination and pronation, and knee extension and flexion. MAIN OUTCOME MEASURES: Peak torque at 120 degrees/sec on a Biodex isokinetic dynamometer. RESULTS: Control subjects had significantly higher peak torque in wrist extension, flexion, supination, and pronation than CTD subjects on the symptomatic side. Control subjects also had significantly higher peak torque of wrist flexion, pronation, and supination than CTD subjects on the asymptomatic side; wrist extension was greater, but this did not reach significance. In addition, control subjects had significantly higher peak torque in knee extension and flexion than CTD subjects. CTD subjects had significantly greater left-right asymmetry in wrist extension torque than did control subjects. CONCLUSIONS: Isokinetic peak torque is diffusely reduced in women with unilateral CTDs compared with healthy control subjects, these differences occurring in symptomatic and asymptomatic limbs.

Adolescent↗

Human quadriceps cross-sectional area, torque and neural activation during 6 months strength training.

Quadriceps muscle and fibre cross-sectional areas (CSA), torque and neural activation were studied in seven healthy males during 6 months of weight training on alternate days with six series of eight unilateral leg extensions at 80% of one repetition maximum. After training, the quadriceps cross-sectional area increased by 18.8 +/- 7.2% (P < 0.001) and 19.3 +/- 6.7% (P < 0.001) in the distal and proximal regions respectively, and by 13.0 +/- 7.2% (P < 0.001) in the central region of the muscle. Hypertrophy was significantly different between and within the four constituents of the quadriceps. Biopsies of the vastus lateralis at mid-thigh did not show any increase in mean fibre cross-sectional area. Maximum isometric voluntary torque increased by 29.6 +/- 7.9%-21.1 +/- 8.6% (P < 0.01-0.05) between 100 degrees and 160 degrees of knee extension, but no change in the optimum angle (110 degrees-120 degrees) for torque generation was found. A 12.0 +/- 10.8% (P < 0.02) increase in torque per unit area together with a right shift in the IEMG-torque relation and no change in maximum IEMG were observed. Time to peak isometric torque decreased by 45.8% (P < 0.03) but no change in time to maximum IEMG was observed. In conclusion, strength training of the quadriceps results in a variable hypertrophy of its components without affecting its angle-torque relation. The increase in torque per unit area, in the absence of changes in IEMG, may indicate changes in muscle architecture. An increase in muscle-tendon stiffness may account for the decrease in time to peak torque.

Adult↗

Characterization of contralateral torques during static hip efforts in healthy subjects and subjects with hemiparesis.

Contralateral torques exerted at the hip were measured in healthy subjects and subjects with hemiparesis performing unilateral static hip efforts in abduction, adduction, flexion and extension, in a sitting position, at two torque levels. In general, the ipsilateral hip efforts were accompanied by mirrored contralateral torques in both groups of subjects. The directionality of these contralateral torques indicates that their action at the pelvis is mechanically opposite to the ipsilateral efforts, suggesting that they ensure the stabilization of the pelvis. In healthy subjects, analyses of variance showed no difference in the magnitude of the contralateral torques with regard to which limb was used to perform the task. However, a significant increase in magnitude was demonstrated in the contralateral torques concurrent with the increasing level of effort requested ipsilaterally. In hemiparetic subjects, when performing the tasks with their paretic limb, the magnitude of the contralateral torques was significantly increased in the non-paretic limb when compared with those measured in the paretic limb during non-paretic limb efforts. Based on the present results, a model of postural control is presented to explain the relationship between the ipsilateral and contralateral torques. Using this model, it is hypothesized that the increased contralateral torques observed in hemiparetic subjects when performing the tasks with their paretic limb is related to the weakness of the paretic muscles. The clinical importance of exercises used for the re-education of the paretic lower limb in this population, which consist of resisting the non-paretic hip movements in order to strengthen the paretic hip muscles, is discussed in light of these results.

Adult↗